• Title/Summary/Keyword: Fetal heart rate estimation

Search Result 7, Processing Time 0.023 seconds

Development of a Fetal Heart Rate Detection Algorithm using Phonogram (포노그램을 이용한 태아 심박률 검출 알고리즘의 개발)

  • Kim, Dong-Jun;Kang, Dong-Kee
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.4
    • /
    • pp.167-174
    • /
    • 2002
  • This study describes a fetal heart rate(FHR) estimation algorithm using phonogram. Using a phonogram amplifier, various fetal heart sounds are collected in a university hospital. The FHR estimation algorithms consists of a lowpass filter, decimation, envelop detection, pitch detection, and post-processing. The post-processing is the FHR decision procedure using all informations of fetal heart rates. Using the algorithm and other parameters of fetal heart sound, a fetal monitoring software was developed. This can display the original signals, the FFT spectra, FHR and its trajectory. Even though the fetal phonogram amplifier detects the fetal heart sounds well, the sound quality is not so good as the ultrasonography. In case of very week fetal heart sound, autocorrelation of it showed clear periodicity. But two main peaks in one period is an obstacle in pitch detection and peaks are not so vivid. The proposed FHR estimation algorithm showed very accurate and stable results. Since the developed software displays multiple parameters in real time and has convenient functions, it will be useful for the phonogram-style fetal monitoring device.

A Study on The Davelopement of Electronic Fetal Heart Rate Monitoring System Using Personal Computer (개인용 컴퓨터를 이용한 전자 태아심음 감시장치의 개발에 관한 연구)

  • 정지환;김선일
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.3
    • /
    • pp.209-214
    • /
    • 1991
  • Digital fetal monitoring system based on the personal computer combined with the digital signal processing (DSP) board was implemented. The DSP board acquires and digitally processes ultra- sound fetal Doppler signal for digital signal conditioning, rectification, low -pass filtering, autocorrealtion function calculation and its peak detection. The personal computer interfaced with the DSP board is in charge of graphic display, hardcopy, data transmission and on -line analysis of fetal heart rate change including on - line warning system, base -line estmation, acceleration, deceleration and variability. It is one of the most suitable situation to apply the DSP chip for siganl conditioning, digital filtering of ultrasound fetal Dopier signal and fetal heart rate estimation using autocorrelation technique .

  • PDF

Fetal heart rate estimation algorithm for real-time processing (실시간처리를 위한 태아심음 추출 알고리듬)

  • Lee, Eung-Gu;Lee, Yong-Hui;Kim, Seon-Il;Lee, Du-Su
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.05
    • /
    • pp.96-99
    • /
    • 1994
  • Despite the simplicity of processing, a conventional autocorrelation function(ACF) method for the precise determination of fetal heart rate (FHR) has many problems. In case of weak or noise corrupted Doppler ultrasound signal. the ACF method is very sensitive to the threshold level and data window length. It is very troublesome to extract FHR when there is a data loss. To overcome these problems, the high resolution pitch detection algorithm was adopted to estimate the FHR. This method is more accurate, robust and reliable than the ACF method. With a lot of calculation, however, it is impossible to process real time FHR estimation. This paper is presented a new FHR estimation algorithm for real time processing.

  • PDF

Improvement of Fetal Heart Rate Extraction from Doppler Ultrasound Signal (도플러 초음파 신호에서의 태아 심박 검출 개선)

  • Kwon, Ja Young;Lee, Yu Bin;Cho, Ju Hyun;Lee, Yoo Jin;Choi, Young Deuk;Nam, Ki Chang
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.9
    • /
    • pp.328-334
    • /
    • 2012
  • Continuous fetal heart beat monitoring has assisted clinicians in assuring fetal well-being during antepartum and intrapartum. Fetal heart rate (FHR) is an important parameter of fetal health during pregnancy. The Doppler ultrasound is one of very useful methods that can non-invasively measure FHR. Although it has been commonly used in clinic, inaccurate heart rate reading has not been completely resolved.. The objective of this study is to improve detection algorithm of FHR from Doppler ultrasound signal with simple method. We modified autocorrelation function to enhance signal periodicity and adopted adaptive window size and shifted for data segment to be analysed. The proposed method was applied to real measured data, and it was verified that beat-to-beat FHR estimation result was comparable with the reference fetal ECG data. This simple and effective method is expected to be implemented in the embedded system.

Fetal heart rate estimation using high resolution pitch detection algorithm (피치 검출 방법을 이용한 태아심음주기의 추출에 관한 연구)

  • Lee, Eung-Goo;Lee, Yong-Hee;Kim, Sun-I.;Lee, Doo-Soo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.05
    • /
    • pp.81-85
    • /
    • 1993
  • Despite the simplicity of processing, conventional autocorrelation function (ACF) method for the precise determination of fetal heart rate (FHR) has many problems. In the case of weak or noise corrupted Doppler ultrasound singnals, the ACF method is very sensitive to the threshold level and data window length. It is real troublesome to extract FHR when there is a data loss. To overcome these problems, the high resolution pitch detection algorithm is adapted to estimate the FHR. The FHR is determined from the correlation of two interconnected segments by its maximum correlation value. FHR is compensated with a constant correlation threshold in a greatly smeared noise signal. This method yields more accurate, robust and reliable than the ACF method.

  • PDF

A study on the real time fetal heart rate monitoring system by high resolution pitch detection algorithm (고해상 피치 검출 알고리듬을 적용한 실시간 태아 심음 감시시스템에 관한 연구)

  • 이응구;이두수
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.175-182
    • /
    • 1995
  • Despite the simplicity of processing, a conventional autocorrelation function (ACF) method for the precise determination of fetal heart rate (FHR) has many problems. In case of weak or noise corrupted Doppler ultrasound signal, the ACF method is very sensitive to the threshold level and data window length. It is very troublesome to extract FHR when there is a data loss. To overcome these problems, the high resolution pitch detection algorithm was adopted to estimate the FHR. This method is more accurate, robust and reliable than the ACF method. With a lot of calculation, however, it is impossible to process real time FHR estimation. This paper is presented a new FHR estimation algorithm for real time processing and studied the real time FHR monitoring system by high resolution pitch detection algorithm.

  • PDF

Review of 2011 Major Medical Decisions (2011년 주요 의료 판결 분석)

  • Yoo, Hyun-Jung;Seo, Young-Hyun;Lee, Jung-Sun;Lee, Dong-Pil
    • The Korean Society of Law and Medicine
    • /
    • v.13 no.1
    • /
    • pp.199-247
    • /
    • 2012
  • According to the review and analysis of medical cases that are assigned to the Supreme Court and all local High Court in 2011 and that are presented in the media, it was found that the following categories were taken seriously, medical and pharmaceutical product liability, the third principle of trust between medical institutions, negligence and causation estimation, responsibility limit, the meaning of medical records and related judgment of disturbed substantiation, Oriental doctors' duties to explain the procedures, IMS events, whether one can claim for each medical care operated by non-physician health care institutions to the nonmedical domain in the National Health Insurance Corporation, and the basis of norms for each claim. In the cases related to medical pharmaceutical product liability, Supreme Court alleviated burden of proof for accidents with medical and pharmaceutical products prior to the practice of Product Liability Law and onset the point of negative prescription as the time of damage strikes to condition feasibility of the specific situation. In the cases related to the 3rd principle of trust between medical institutions, the Supreme Court refused to sentence the doctor who has trusted the judgment of the same third-party doctors the violations of the care duty. With respect to proof of a causal relationship and damages in a medical negligence case, the Supreme Court decided that it is unjust to deny negligence by the materials of causal relationship rejecting the original verdict and clarified that the causal relationship shall not deny the reasons to limit doctors' responsibilities. In order not put burden on patients with disadvantages in which medical records and the description of the practice or the most fundamental and important evidence to prove negligence and causation are being neglected, the Supreme Court admitted in the hospital's responsibility for the case of the neonate death of suffocation without properly listed fetal heart rate and uterine contraction monitor. On the other hand, the Seoul Western District Court has admitted alimony for altering and forging medical records. With respect to doctors' obligations to description, the Supreme Court decided that it is necessary to explain the foreseen risks by the combination of oriental and western medicines emphasizing the right of patient's self-determination. However, questions have arisen whether it is realistically feasible or not. In a case of an unlicensed doctor performing intramuscular stimulation treatment (IMS), the Supreme Court put off its decision if it was an unlicensed medical practice as to put limitation of eastern and western medical practices, but it declared that IMS practice was an acupuncture treatment therefore the plaintiff's conduct being an illegal act. In the future, clear judgment on this matter should be made. With respect to the claim of bills from non-physical health care institutions, the Supreme Court decided to void it for the implementation of the arrangement is contrary to the commitments made in the medical law and therefore, it is invalid to claim. In addition, contrast to the private healthcare professionals, who are subject to redemption according to the National Healthcare Insurance Law, the Seoul High Court explicitly confirmed that the non-professionals who receive the tort operating profit must return the unjust enrichment and have the liability for damages. As mentioned above, a relatively wide range of topics were discussed in medical field of 2011. In Korea's health care environment undergoing complex changes day by day, it is expected to see more diverse and in-depth discussions striding out to the development in the field of health care.

  • PDF