• 제목/요약/키워드: Ferrite transformer

검색결과 41건 처리시간 0.03초

Flat TR용 페라이트 코아의 고주파 동작 특성 (Study on operating characteristics of Ferrite cores for Flat TR in high frequency)

  • 한세원;조한구;류동욱;최광보
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1168-1171
    • /
    • 2003
  • In contrast to a conventional transformer, the flat transformer is made using a number of small ferrite cores. Two cores for transformer and one core for inductor, which composed one module. Many modules can be connected together to form a flat matrix transformer. This structural arrangement eliminates the single hot spot problem in conventional transformers and permits high current density pertains at high frequency. In this study, the ferrite magnetic cores of Mn-Zn system for the Flat transformer were manufactured and the electrical and magnetic characteristics of its tested. The power loss of sample FO2(Mn-Zn ferrite) sintered at $1350^{\circ}C$ was $350kW/m^3$ in test conditions of 250kHz, 200mT and $100^{\circ}C$, which showed the good power loss property in high frequency. The power loss of FO2 samples has been studied as a function of magnetic flux density and frequency. Steinmetz exponent was 2.82 at 250kHz and 2.73 at 500kHz. These results illustrated the switching of power loss mechanism in ferrite core from hysteresis losses to eddy current losses or others.

  • PDF

Performance Evaluations of a Novel Prototype of High Frequency Non-Contact Power Transformer

  • Gamage, Laknath;Ishitobi, Manabu;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제4권1호
    • /
    • pp.12-17
    • /
    • 2004
  • In this paper, a practical implementation to reduce leakage flux of a high-frequency inverter based non-contact type power transformer composed of EE-shape ferrite cores is presented for key technology of the next generation medical use X-ray CT scanner system. Design consideration for the unique structure of the non-contact power transformer with 900mm in diameter is also introduced. The complete non-contact transformer is actually arranged by several blocks of the magnetic circuit assembled by using 10 small EE shape cores with 120mm in length. It is experimentally and analytically discussed from a reduced leakage flux viewpoint related to its inductively coupling coefficient. A practical method to lower the leakage flux is described based on effective Copper-Sheet- Treatment placed on EE shape ferrite cores of magnetic circuit.

400 kHz 페라이트 유도 결합 플라즈마를 위한 임피던스 매칭 네트워크 (The Impedance Matching Network for a ferromagnetic Inductively Coupled Plasma driven at 400 kHz.)

  • 조성원;방진영;이영광;정진욱
    • 반도체디스플레이기술학회지
    • /
    • 제6권2호
    • /
    • pp.29-33
    • /
    • 2007
  • Low frequency (400 kHz) Ferrite ICP has been proposed for large area processing. Because the coupling coefficient is close to 1, the transformer matching can be adapted to Ferrite ICP. The transformer matching system is simple. In this paper the new matching system by controlling the turns of transformer using relays is proposed for impedance matching. We developed a simple matching system and characterized it when the turns were changed. It was observed that the 2-channel relay is available for transformer matching.

  • PDF

차동트랜스 코일을 이용한 Soft-Ferrite 분말의 초투자율측정에 관한 연구 (A Study for measuring the Intial Permeability of Soft-Ferrite Powder by Using Differential Transformer Coil)

  • 전홍배;허진;김철한;사공건
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 전자세라믹스 센서 및 박막재료 반도체재료 일렉트렛트 및 응용기술
    • /
    • pp.68-71
    • /
    • 2000
  • In this study, A set-up for measuring a initial permeability of soft-ferrite powder was developed with a differential transformer coil. To measure a initial permeability of magnetic powder is cumbersome since there are not any measuring equipment and method. A magnetic powder is currently used for a magnetic fluid and microwave absorber materials, and the initial permeability of the magnetic powders is very important to be evaluated a powder for some applications.

  • PDF

Design, Implementation and Testing of HF transformers for Satellite EPS Applications

  • Zahran, Mohamed
    • Journal of Power Electronics
    • /
    • 제8권3호
    • /
    • pp.217-227
    • /
    • 2008
  • The electric power subsystems (EPS) of most remote sensing satellites consist of a solar array as a source of energy, a storage battery, a power management and control (PMC) unit and a charge equalization unit (CEU) for the storage battery. The PMC and CEU use high frequency transformers in their power modules. This paper presents a design, implementation and testing results of a high frequency transformer for the EPS of satellite applications. Two approaches are used in the design process of the transformer based on the pre-determined transformer specifications. The transformer is designed based on an ETD 29 ferrite core. The implemented transformer consists of one center-tapped primary coil with eleven center-tapped secondary coils. The offline calculation results and measured values of R, L for transformer coils are convergence. A test circuit for measuring the transformer parameters like voltage, current and B-H hysteresis was implemented and applied. The test results confirm that the voltage waveforms of both primary and secondary coils were as desired. No overlapping occurred between the control signal and the transformer, which was not saturated during testing even during a short circuit test of the secondary channels. The dynamic B-H loop characteristics of the used transformer cores were measured. The sample test results are given in this paper.

V/UHF-대역 광대역 2분기 전력 분배기 (V/UHF-Band Broadband 2-Way Power Divider)

  • 박여일;고진현;박영주;박동철
    • 한국전자파학회논문지
    • /
    • 제18권4호
    • /
    • pp.416-422
    • /
    • 2007
  • 본 논문에서는 V/UHF 대역인 $20{\sim}500\;MHz$에서 동작하는 광대역 2분기 전력 분배기를 제안하고 페라이트를 이용하여 구현하였다. 4분기 전력 분배기에서 보편적으로 사용되는 4:1 임피던스 변환기 대신 본 논문의 2분기 전력 분배기에서는 2:1 임피던스 변환기를 사용하였다. 구현된 2분기 전력 분배기는 요구 대역 내에서 약 3.5 dB의 삽입 손실, -10 dB 이하의 격리도, -10 dB 이하의 반사 손실 특성을 갖는 것으로 측정되었다.

V/UHF-대역 광대역 4분기 전력 분배기 설계 (Design of a V/UHF-Band Broadband 4-Way Power Divider)

  • 박여일;고진현;하재권;박영주;박동철
    • 한국전자파학회논문지
    • /
    • 제18권8호
    • /
    • pp.904-912
    • /
    • 2007
  • 본 논문에서는 V/UHF 대역인 $20{\sim}500 MHz$에서 동작하는 광대역 4분기 전력 분배기를 전송선 변환기와 페라이트 토로이드를 이용하여 설계하였다. 4:1 임피던스 변환기를 구현하였고, 이 4:1 변환기는 4분기 전력 분배기를 구현하기 위해 브리지 구조를 이용한 2분기 전력 분배기와 연결되었다. 구현된 4분기 전력 분배기는 요구대역 내에서 약 6.8dB의 삽입 손실, -20dB 이하의 격리도, -15dB 이하의 반사 손실 특성을 갖는 것으로 측정되었다.

Electromotive Force Characteristics of Current Transformer According to the Magnetic Properties of Ferromagnetic Core

  • Kim, Young Sun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권1호
    • /
    • pp.37-41
    • /
    • 2015
  • The most common structure of the current transformer (CT) consists of a length of wire wrapped many times around a silicon steel ring passed over the circuit being measured. Therefore, the primary circuit of CT consists of a single turn of the conductor, with a secondary circuit of many tens or hundreds of turns. The primary winding may be a permanent part of the current transformer, with a heavy copper bar to carry the current through the magnetic core. However, when the large current flows into a wire, it is difficult to measure its magnitude of current because the core is saturated and the core shows magnetic nonlinear characteristics. Therefore, we proposed a newly designed CT which has an air gap in the core to decrease the generated magnetic flux. Adding the air gap in the magnetic path increases the total magnetic reluctance against the same magnetic motive force (MMF). Using a ferrite core instead of steel also causes the generation of low magnetic flux. These features can protect the magnetic saturation of the CT core compared with the steel core. This technique can help the design of the CT to obtain a special shape and size.

유한요소법과 상태방정식을 이용한 포워드 컨버터의 동작 특성 해석 (Characteristics Analysis of a Forward Converter by Finite Element Method and State Variables Equation)

  • 박성진;권병일;박승찬
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권9호
    • /
    • pp.467-475
    • /
    • 1999
  • This paper presents an analysis method of a forward converter, using both the finite element method considering the external circuit and a state variables equation. The converter operates at 50kHz and its one period is divided into two modes for the simplicity of the analysis. In the first mode, the switching transistor turns on and an input power is transferred into the load by the electromagnetic conversion action of a ferrite transformer. In the second mode, the switching transistor turns off and the stored energy in an inductor is delivered to the load, and the transformer core is demagnetized by the reset winding current. In this paper, time-stepping finite element method taking into account the on-state electrical circuit of the converter in used to analyze both the electrical circuit and electromagnetic field of the magnetic device during the first mode and the demagnetization period of the transformer core. Then a state variables equation for the circuit which the inductor current flows is constituted and solved during the second mode. As a result, the simulation results have been good agreement with the results obtained form experiment.

  • PDF

고주파 트랜스포머의 권선기법 따른 손실특성 (Power Loss Characteristics according to Winding Method of High Frequency Transformer)

  • 김일남;윤신용;이공희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.49-51
    • /
    • 2004
  • This paper researched the power loss characteristics according to winding method of high frequency transformer. Power loss was analyzed by PExprt using FEM software. The ferrite core model for analysis be used the EE type. Transformer model objected type applied to flyback converter. Therefore, analysis result was obtained the many parameter of DC, AC resistance, leakage inductance, copper loss, core loss, and temperature etc.

  • PDF