• 제목/요약/키워드: Fenton oxidation process

검색결과 87건 처리시간 0.029초

EFFECTS OF REACTION TIME AND pH ON FENTON'S BATCH PROCESS FOR THE TREATMENT OF LEACHATE

  • Choi, Heung-Jin;Kim, Il-Kyu
    • 한국물환경학회지
    • /
    • 제18권2호
    • /
    • pp.169-187
    • /
    • 2002
  • The effects of important parameters such as reaction time and pH on the Fenton's process were evaluated using a batch reactor. It was proven that organic materials and heavy metals in leachate could be successfully removed by Fenton's reagent. Favorable operation conditions were investigated. It was observed that the reaction between ferrous iron and hydrogen peroxide with the production of hydroxyl radical was almost complete in 10 minutes. That is, the oxidation of organic materials by Fenton's reagent was so fast that it was complete in 30 minutes with batch experiments. With the formation of carbonic acid, pH of the batch reactor decreased to favorable acidic conditions without acid addition. The oxidation of organic materials in the leachate showed a pH dependence and was most efficient in the pH range of 2-3.

펜톤산화에 따른 복합폐수의 처리효율연구 (Treatment Efficiency of Complex Wastewater by Fenton's Oxidation Condition)

  • 성일화
    • 한국환경보건학회지
    • /
    • 제32권5호
    • /
    • pp.446-450
    • /
    • 2006
  • In order to treat the wastewater containing organic compound, pre-treatment system connected with MSP(molecular separation process) was investigated. With the aim of selecting an optimum process of Fenton's oxidation, removal efficiency of each process in the optimum reaction condition was recommended. The $Fe/H_{2}O_{2}$(ferric sulfate to hydrogen peroxide)reagent is referred to as the Fenton's regent, which produces hydroxyl radicals by the interaction of Fe with $H_{2}O_{2}$. The powerful oxidizing ability and extreme kinetic reactively of the hydroxyl radical was well established. Increasing dosage of $Fe/H_{2}O_{2}$ increased removal efficiency as molar ratio of $Fe/H_{2}O_{2}$ between 0.2 and 2.5. Optimum dosage of molar ratio was 1. The removal efficiency for reaction condition was increased as pH decreased when the molar ratio of $Fe/H_{2}O_{2}$ was 1.7. Fenton's oxidation was most efficient in the reaction time 35 min for complex wastewater. Also, coagulation aid experiments using kaolin resulted in 3% of kaolin dosage.

전응집 및 Fenton 산화공정을 이용한 축산폐수의 난분해성물질 제거특성에 관한 연구 (Degradation Characteristics of Non-biodegradable Matters using Pre-Coagulation and Fenton Oxidation Process in Livestock Wastewater)

  • 조창우;김병용;채수천;김선애;정팔진
    • 한국물환경학회지
    • /
    • 제22권1호
    • /
    • pp.66-73
    • /
    • 2006
  • The purpose of this study was done to evaluate degradation characteristics of non-biodegradable organic matters including aromatic compounds in livestock wastewater using CFZ process. The CFZ process is consisted of coagulation/sedimentation, Fenton oxidation and zeolite adsoption process. degradation charateristics of each treatment water including livestock wastewater were analyzed by UV scanning, FT-IR and GC/MS. After coagulation/sedimentation process as 1st treatment, non-biodegradable matters remained after 1st treatment were removed by using OH radical produced in Fenton oxidation process. As a result of treatment using these processes, NBDCOD removal efficiency was over 90%. Increase of $E_2/E_3$ ratio (absorbance at 250 and 365 nm) in each treatment water means that aromaticity of livestock wastewater decreased. In case of GC/MS, most aromatics or polynuclear aromatics like benzene, phenol and scatol in livestock wastewater almost wasn't detected after oxidation using OH radical.

펜톤산화 공정에서 발생하는 슬러지의 재활용 방안 (Methodology Development for the Reuse of Sludge Generated from Fenton's Oxidation Process)

  • 구태완;조순행;최영수
    • 대한환경공학회지
    • /
    • 제22권6호
    • /
    • pp.1083-1091
    • /
    • 2000
  • 본 연구는 펜톤산화 공정에서 발생되는 펜톤슬러지를 응집제와 펜톤산화 공정에서의 촉매로 재이용할 수 있는지 여부를 검토하여 고농도의 난분해성 유기물질을 함유한 침출수를 효과적이고 경제적으로 처리할 수 있는 기술을 개발하는데 그 목적을 두었다. Batch-Scale 연구 결과 펜톤슬러지를 응집제와 펜톤산화 공정의 촉매제로 혼합사용하여 응집 공정과 펜톤산화 공정에 적용할 경우 약품만을 사용하는 경우보다 응집제의 사용량을 50%, 펜톤산화 공정의 촉매제 사용량을 50% 감소시킬 수 있었으며, 응집 공정과 펜톤산화 공정에서 발생되는 슬러지의 발생량도 감소시킬 수 있는 것으로 조사되었다. 실험실 규모의 연속식 처리 실험을 수행한 결과 펜톤슬러지를 응집제로 재이용함으로써 평균 8.5% 정도 유기물 제거효율이 증가하였으며, 슬러지의 발생량은 35% 감소하는 것으로 조사되었다. 또한 펜톤슬러지를 펜통촉매제로 재이용함으로써 유기물 제거면에서 평균 5.3% 정도 효율이 증가하였으며, 슬러지의 발생량은 14% 정도 감소하는 것으로 조사되었다. 이상의 결과로 펜톤산화 공정에서 발생하는 슬러지의 재이용은 약품 비용이나 슬러지 처리 비용을 절감시킬수 있을 것으로 결론지을 수 있다.

  • PDF

광펜톤 반응에 의한 수중 2-클로로페놀 분해특성연구 (Degradation of 2-Chlorophenol in the Aqueous Phase by a Photo-Fenton Process)

  • 김일규
    • 상하수도학회지
    • /
    • 제26권6호
    • /
    • pp.779-786
    • /
    • 2012
  • The degradation of 2-chlorophenol(2-CP) by various AOPs(Advanced Oxidation Processes) including the photo-Fenton process has been examined. In sole $Fe^{2+}$, UV or $H_2O_2$ process without combination, low removal efficiencies have been achieved. But the photo-Fenton process showed higher removal efficiency for degradation of 2-chlorophenol than those of other AOPs including the Fenton process and the UV processes. In the photo-Fenton process, the optimal experimental conditions of 2-chlorophenol degradation were obtained at pH 3 and the $Fe^{2+}/H_2O_2$molar ratio of 1. Also the 2-chlorophenol removal efficiency increased with decreasing of the initial 2-chlorophenol concentration. 3-chlorocatechol and chlorohydroquinone were identified as photo-Fenton reaction intermediates, and a degradation pathway of 2-chlorophenol in the aqueous phase during the photo-Fenton reaction was proposed.

과산화수소 연속주입식 광펜톤산화공정에 의한 4-염화페놀 분해연구 (Degradation of 4-Chlorophenol by a Photo-Fenton Process with Continuous Feeding of Hydrogen Peroxide)

  • 김일규
    • 상하수도학회지
    • /
    • 제27권1호
    • /
    • pp.31-38
    • /
    • 2013
  • The degradation of 4-chlorophenol(4-CP) by various AOPs(Advanced Oxidation Processes) with continuous feeding of $H_2O_2$, including the ultraviolet/hydrogen peroxide, the Fenton and the photo-Fenton process has been investigated. The photo-Fenton process showed the highest removal efficiency for degradation of 4-chlorophenol than those of other AOPs including the Fenton process and the combined UV process with continuous feeding of $H_2O_2$. In the photo-Fenton process, the optimal experimental condition for 4-CP degradation was obtained at pH 3. Also the 4-CP removal efficiency increased with decreasing of the initial 4-CP concentration. 4-chlorocatechol and 4-chlororesorcinol were identified as photo-Fenton reaction intermediates, and the degradation pathways of 4-CP in the aqueous phase during the photo-Fenton reaction were proposed.

A comparative study on applicability of nano-sized iron(II, III) oxide in ultrasonicated Fenton process

  • Sahinkaya, Serkan;Yakut, Sennur Merve
    • Environmental Engineering Research
    • /
    • 제25권1호
    • /
    • pp.36-42
    • /
    • 2020
  • Fenton process is one of the most effective advanced oxidation processes for the removal of pollutants from wastewater. In this study, while ferrous iron was used in conventional Fenton process (CFP); nano-sized iron(II, III) oxide was experienced in modified Fenton process (MFP) as a new catalyst alternative. In order to enhance their oxidation efficiencies, both CFP and MFP were combined with ultrasonication at 53 kHz fixed frequency. Thus, the influences of both catalyst iron species and ultrasonication on color and chemical oxygen demand (COD) removals from synthetic textile wastewater including Maxilon Red GRL 200% dyestuff were investigated experimentally. While the COD and color removal rates were found as 72.5% and 69.7% via CFP; they were 87% and 75.8% by ultrasonicated CFP, respectively. The color and COD removals were 40.6% and 64.8% via MFP, and 49.9 and 73.1% by ultrasonicated MFP, respectively. Therefore, it was found that the simultaneously usage of ultrasonication with CFP and MFP was improved the COD and color removal efficiencies and oxidation rates even at lower H2O2 dosages, compared to individual CFP and MFP. Moreover, the color and COD removal kinetics were also modelled mathematically and compared in the study.

산 완충능력과 토양 성분이 동전기-펜톤 공정에 의한 phenanthrene 오염토양 정화에 미치는 영향 (Effect of Acid Buffering Capacity and Soil Component Remediation of Soil Contaminated with Phenanthrene using Electrokinetic-Fenton Process)

  • 김정환;나소정;박주양;변영덕
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제18권1호
    • /
    • pp.129-136
    • /
    • 2013
  • This research was conducted to investigate effects of acid buffering capacity and soil component in treatment of phenanthrene using electrokinetic-Fenton process. In Hadong clay of high acid buffering and low iron oxide content, it was difficult to oxidize phenanthrene due to shortage of iron catalyst and scavenger effect of carbonate minerals. The desorbed phenanthrene conductive to Fenton oxidation was transported toward cathode by electroosmotic flow. However, in Youngdong illitic clay, oxidation of phenanthrene near anode readily occurred compared to Hadong clay due to high iron content and low acid buffering capacity.

Degradation of energetic compounds using an integrated zero-valent iron-Fenton process

  • Oh Seok-Young;Kim Byung J.;Chiu Pei C.;Cha Daniel K.
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2003년도 Proceedings of the international symposium on the fusion technology
    • /
    • pp.493-500
    • /
    • 2003
  • The effect of reductive treatment with elemental iron on the extent of mineralization by Fenton oxidation was studied for the explosive 2,4,6-trinitrotoluene (TNT) and hexahydro-l,3,5-trinitro-l,3,5-triazine (RDX) using a completely-stirred tank reactor (CSTR). The results support the hypothesis that TNT and RDX are reduced with elemental iron to products that are oxidized more rapidly and completely by Fenton's reagent. Iron pretreatment enhanced the extent of TOC removal by approximately $20\%\;and\;60\%$ for TNT and RDX, respectively. Complete TOC removal was achieved for TNT and RDX solutions with iron pretreatment under optimal conditions. On the other hand, without iron pretreatment, complete mineralization of TNT and RDX solutions were not achieved even with much higher $H_2O_2$ and $Fe^{2+}$ concentrations. The bench-scale iron treatment-Fenton oxidation integrated system showed more than $95\%$ TOC removal for TNT and RDX solutions under optimal conditions. The proposed zero-valent iron-Fenton process was evaluated with pink water from the Iowa Army ammunition plant. Results from batch and column experiments show that TNT, RDX, and octahydro-l,3,5,7-tetranitro-l,3,5,7-tetrazocine (HMX) were completely removed from the pink water and that triaminotoluene (TAT) and ${NH_4}^+$ were recovered as products in reduction with zero-valent iron. By using an integrated system, $83.3\pm4.2\%$ of TOC was removed in a CSTR with 10 mM of $Fe^{2+}$ and 50 mM of $H_2O_2$. These results suggest that the reduction products of TNT and RDX are more rapidly and completely mineralized by Fenton oxidation and that a sequential iron treatment-Fenton oxidation process may be a viable technology for pink water treatment.

  • PDF

광-펜톤 산화반응을 이용한 Rhodamine B의 탈색 (Decolorization of Rhodamine B by Photo-Fenton Oxidation)

  • 박영식
    • 한국물환경학회지
    • /
    • 제23권2호
    • /
    • pp.274-280
    • /
    • 2007
  • The photochemical decolorization of Rhodamine B (RhB) in water has been carried out by photo-Fenton process. The effect of applied $H_2O_2$, $Fe^{2+}$ dose, solution pH and UV dose have been studied. The influence of constituent processes of photo-Fenton such as UV, $H_2O_2$ and Fenton has been investigated. Comparison of RhB removal was made between the photo-Fenton and $UV/H_2O_2$ process. The results obtained showed that the optimum dosage of $Fe^{2+}$ and $H_2O_2$ were 0.0031 mmol and 0.625 mol, respectively. pH 3 is found to be the optimum pH of for photo-Fenton process. pH and UV dose strongly influenced the decolorization of RhB in photo-Fenton process. The photo-Fenton and $UV/H_2O_2$ processes showed similar decolorization and seem to be appropriate for the decolorization of dye wastewater.