• Title/Summary/Keyword: Femoral bone model

Search Result 59, Processing Time 0.027 seconds

Development of Femoral Bone Model of Human Body for Simulation of Side Falls (측면낙상 시뮬레이션용 대퇴골 모델 개발에 관한 연구)

  • Park, Ji Su;Koo, Sang-Mo;Kim, Choong Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.7
    • /
    • pp.956-961
    • /
    • 2014
  • Due to the increasing needs of anti-fall device for elderly, it is required to develop the test rigs for fall simulation. The femoral bone model consists of silicone and steel is used as an effective device to simulate falls. In this work, we propose five different femoral bone models and analyse them by using a commercial FEA tool. It has been shown that two kinds of simplified models exhibit the simulated side falls with an error range of ~1% in the impact load of femoral neck compared with full model. Especially, the upper tissue model is found to provide us with the best efficient test environment, attributable to its simple structure.

Oblique Single-Cut Rotation Osteotomy for Correction of Femoral Varus-Torsional Deformities in 3D-Reconstructed Canine Bone Models

  • Kim, Hyeon-Ho;Roh, Yoon-Ho;Lee, Je-Hun;Jeong, Jae-Min;Jeong, Seong Mok;Lee, Hae Beom
    • Journal of Veterinary Clinics
    • /
    • v.37 no.4
    • /
    • pp.180-184
    • /
    • 2020
  • The purpose of this study was to report the reliability and validity of oblique single-cut rotation osteotomy (OSCRO) in 3D-reconstructed canine bone models with femoral varus and torsional deformities. A healthy adult male beagle was recruited to create a 3D bone model, and this bone model was modified by using a 3D program. Fifteen bone models were constructed for this study. OSCRO simulation was performed in accordance with the plan after printing using a 3D printing machine. The anatomical lateral distal femoral angle (aLDFA), anteversion angle (AA), anatomical caudo-distal femoral angle (aCdDFA), mechanical caudo-distal femoral angle (mCdDFA) and pre- and postoperative bone length were calculated. There were no significant differences between the target values and postoperative values. In addition, the difference between pre- and postoperative bone length was small (p = 0.001). Our findings suggest that OSCRO could be an effective surgical option for MPL with bone deformities in small-breed dogs that often undergo conventional distal femoral osteotomy.

Approximated 3D non-homogeneous model for the buckling and vibration analysis of femur bone with femoral defects

  • Mobasseri, Saleh;Sadeghi, Mehdi;Janghorban, Maziar;Tounsi, Abdelouahed
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.5 no.1
    • /
    • pp.25-35
    • /
    • 2020
  • We carry the knowledge that the skeleton bones of the human body are not always without defects and some various defects could occur in them. In the present paper, as the first endeavor, free vibration and buckling analysis of femur bones with femoral defects are investigated. A major strength of this study is the modeling of defects in femur bones. Materialise Mimics software is adopted to model the bone geometry and the SOLIDWORKS software is used to generate the defects in bones. Next, the ABAQUS software is employed to study the behaviors of bones with defects.

Effects of Electrical Stimulation on Femoral Fracture Healing in a Dog Model (전기자극이 개의 대퇴골절 치유에 미치는 영향)

  • 박경철;이주명;윤영민;강태영;김희석;이경갑;강윤호;정종태
    • Journal of Veterinary Clinics
    • /
    • v.20 no.3
    • /
    • pp.328-333
    • /
    • 2003
  • This study was performed to investigate the effects of electrical stimulation on femoral fracture healing in dogs. Eight healthy dogs from 4 to 5 $\beta^3$ were used in this experiment. In the treatment group, anode and cathode were connected to proximal and distal site apart from the fracture line by 2 cm and electrical stimulation was applied to the fracture site for l5minutes by 2 V, 25 Hz and for a month. The control group was connected to electrostimulator as the treatment group, but no electrical stimulation was applied. Various parameters were evaluated including radiograph and serum levels of total-ALP(TALP), bone-ALP(BALP) and osteocalcin. The radiography revealed more rapid callus formation in the treatment group than in the control by about a week. The total-ALP levels of the treatment group were higher than those of the control group from the 2nd to the 24th day(p< 0.05). The bone-ALP levels of the treatment group were significantly higher than those of the control from the 2nd to the 24th day(p< 0.05). The bone-ALP/ total-ALP ratios of the treatment group were higher than those of control throughout this experiment but there were no significance. There were no significance in the osteocalcin levels between two groups. In conclusion, the electrical stimulation on femoral fracture site was effective for bone healing in dogs.

Bone Changes in Femoral Bone of Mice Using Calcein Labeling (Mice에서 Calcein 표지를 이용한 골 변화 관찰)

  • Shim, Moon-Jung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.2
    • /
    • pp.114-117
    • /
    • 2016
  • In vivo labeling of bone with fluorochromes is a widely used method for assessment of bone formation and remodeling processes. In particular, calcein is used as a marker for identification of bone growth, which is indicated by a green color. Calcein green is a calcium chelator that adheres to regions of mineralizing bone thereby allowing localization of new bone. Bone formation and remodeling in vivo can be assessed by calcium-binding calcein labeling. In this study, changes in the femoral bone of a normal mouse model at both 4 and 8 weeks were evaluated using calcein labeling. Intense deposition of calcium in the bone was observed after application for 8 weeks. A mouse model is suitable for application in in vivo experiments using genetically modified mice, such as knock-out mice, however data regarding femoral cross sectional bone in young mice are limited. The current study confirmed calcein as a useful marker for identification of bone growth, which was indicated by a green color on photomicrographs. This methodological process may provide basic information for interpreting bone formation and regeneration to pharmacologic or genetic manipulation in mice.

An Analysis of Stress Transfer Behaviors within the Necrotic Cancellous Bone following Surgical Procedures or the Management of the Osteonecrosis of the Femoral Head (대퇴골두 무혈성 괴사증의 수술적 기법 적용 후 괴사 망상골 내에서의 응력 변화 해석)

  • Kim, J.S.;Lee, S.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.245-248
    • /
    • 1997
  • Operative interventions for the management of osteonecrosis of the femoral head (ONFH) include core drilling, with or without vascularized fibular bone grafting. Nevertheless, their clinical results have not been consistently satisfactory. Recently, a new surgical procedure that incorporates cementation with polymethylmethacrylate (PMMA) after core drilling has been tried clinically. In this study, a biomechanical analysis using a finite element method(FEM) was undertaken to evaluate surgical methods and their underlying surgical parameter. Our finite element models included five types. They were (1) normal model (Type I), (2) necrotic model (Type II), (3) core decompressed model (Type III). (4) fibular bone grafted model (Type IV), and (5) cemented with PMMA model (Type V). The geometric dimensions of the femur were based on digitized CT-scan data of a normal person. Various physiological loading conditions and surgical penetration depths by the core were used as mechanical variables to study their biomechanical contributions in stress transfer within the femoral head region. In addition. the peak von Mises stress(PVMS) within the necrotic cancellous bone of the femoral head was obtained. The fibular bone grafted method and cementation method provided optimal stress transfer behaviors. Here. substantial increase in the low stress level was observed when the penetration depth was extended to 0mm and 5mm from the subchondral region. Moreover, significant decrease in PVMS due to surgery was observed in the fibular bone grafted method and the cementation method when the penetration depths were extended up to 0 and 5mm from the subchondral region. The drop in PVMS was greater during toe-off than during heel-strike (57% vs. 28% in Type IV and 49% vs. 22% in Type V). Both the vascularized fibular bone grafting method (Type IV) and the new PMMA technique (Type V) appear to be very effective in providing good stress transfer and reducing the peak Von-Mises stress within the necrotic region. Overall results show that fibular bone grafting and cementation methods are quite similar. In light of above results, the new cementation method appears to be a promising surgical alternative or the treatment of ONFH. The use of PMMA for the core can be less prone to surgical complication as opposed to preparation of fibular bone graft and can achieve more immediate fixation between the core and the surrounding region.

  • PDF

Analysis of the Micro-Structural and Mechanical Properties in Human Femoral Head Trabecular Bone with and without Osteoporosis (대퇴골두 해면골의 미세구조 특성과 기계적 특성의 분석)

  • Won Ye-Yeon;Baek Myong-Hyun;Cui WenQuan;Chun KeyoungJin;Kim Man Kyung
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.519-523
    • /
    • 2004
  • This study investigates micro-structural and mechanical properties of trabecular bone in human femoral head with and without osteoporosis using Micro-CT and finite element-model. 15 cored trabecular bone specimens with 20min of diameter were obtained from femoral heads with osteoporosis (T-score > -2.5 ) resected for total hip arthroplasty, and 5 specimens were removed from femoral head of cadavers, which has no history of musculoskeletal diseases. A high-resolution micro-CT system was used to scan each specimen to obtain histomorphometry indices. Based on obtained micro-images(pixel size=21.31㎛), a FE-model was created to determine mechanical property indices. While non-osteoporosis group had increases trabecular thickness, bone volume, bone volume fraction, degree of anisotropy and trabecular number compared with those of non-osteoporotic group, the non-osteoporotic group showed decreases in trabecular separation and structure model index. Regarding the mechanical property indices, reaction force, apparent stress and young's modulus were 1ower in osteoporotic group than in non-osteoporotic group. Our data shows salient deteriorations in trabecular micro-structural and mechanical properties in human femoral head with osteoporosis.

Fermented soybeans by Rhizopus oligosporus reduce femoral bone loss in ovariectomized rats

  • Yoo, Hyun-Wook;Chang, Moon-Jeong;Kim, Sun-Hee
    • Nutrition Research and Practice
    • /
    • v.8 no.5
    • /
    • pp.539-543
    • /
    • 2014
  • BACKGROUND/OBJECTIVES: Soy isoflavones are structurally similar to estrogen and bind to estrogen receptors, suggesting that they exhibit estrogenic activities; therefore, they are referred to as phytoestrogens. Fermentation may affect the bioavailability of isoflavones altering soy isoflavone glycosides in the form of aglycones. Thus, this study investigated the effects of fermented soybeans by Rhizopus oligosporus on bone metabolism in both young rats as a pilot test and in ovariectomized (ovx) old rats as a model of menopause. MATERIALS/METHODS: In the pilot test, a total of 24 seven-week-old female Sprague-Dawley (SD) rats were fed one of three diets for a period of four weeks: casein, unfermented soybean product, or fermented soybean product by R. oligosporus. In the ovx rat model, 20-week-old SD rats weighing 260-290 g underwent either sham-operation (n = 10) or bilateral ovariectomy (n = 30) and were then fed the AIN-93M diet for one week. Thereafter, rats were fed sham-casein, ovx-casein, ovx-soybean, or ovx-fermented soybean diet for five weeks. After decapitation, femoral bones were isolated and preserved in 9% formalin for assessment of bone mineral density (BMD), bone mineral content (BMC), and bone-breaking strength (BBS). RESULTS: Ovx rats showed significantly increased weight gain and decreased uterine wet weight. Of particular interest, ovx rats fed fermented soybeans showed increased uterine wet weights compared to control rats. Fermented soybean diet caused a significant increase in plasma 17-${\beta}$ estradiol concentrations in young rats, and 17-${\beta}$ estradiol levels were enhanced in ovx rats to match those of sham-operated ones. Significantly lower femoral BMD and BMC were observed in ovx rats compared to sham-operated controls, whereas bone areas did not differ statistically among the groups. In addition, BBS tended to be increased in ovx rats fed soybeans and fermented soybeans. CONCLUSIONS: Supplementation of fermented soybeans could have preventive and therapeutic effects against osteoporosis in postmenopausal women.

Two-Dimensional Finite Element Analysis of Bone Resorption from the Artificial Hip Replacement (인공고관절 골흡수로 인한 응력분포 변화의 2차원 유한요소 해석)

  • Choi, Hyung-Yeon;Chae, Soo-Won;Kim, Sung-Kon
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.1
    • /
    • pp.25-32
    • /
    • 1995
  • Clinically, proximal bone resorption in the femur is frequently seen postoperatively on the follow up XI-rays after total hip replacement (THR). We developed the finite element model of cementless THR. The model is two dimensional side plate model, whereby the three dimensional structural integrity of the bone can be accounted for by a separate two dimensional mesh, a side plate. The subject of this article is the development and application of this two dimensional side plate FEM to study the reverse effect of the various degree of bone resorption of femur after THR. The results of this study indicates that 1) two dimensional side plate model is good and simple alternative to complex three dimensional model and 2) the severity of the proximal bone resorption has the effect of more increasing stress on the cortex at the level of femoral stem tip.

  • PDF

A Study on the Interface Micromotions of Cementless Artificial Hip Replacement by Three-Dimensional FEM (무시멘트형 인공고관절 대치술후 초기의 경계면 미세운동의 3차원 FEM 연구)

  • Kim, S.K.;Chae, S.W.;Choi, H.Y.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.12
    • /
    • pp.71-74
    • /
    • 1994
  • In cementless total hip arthroplasty(THA), an initial stability of the femoral component is mandatory to achieve bony ingrowth and secondary long term fixation. Bone ingrowth depends strongly on relative micromotion and stress distributions at the interface. Primary stability of the femoral component can be obtained by minimizing the magnitude of relative micromotions at bone-prosthesis interface, Hence an accurate evaluation of interface behavior and stress/strain fields in the bone implant system may be relevant for better understanding of clinical situations and improving THA design. However, complete evaluation of load transfer in the bone remains difficult to assess experimentally, Hence, recently finite element method (FEM) was introduced in orthopaedic research field to fill the gap due to its unique capacity to evaluate stress in structure of complex shape, loading and material behavior. The authors developed the 3-dimensional numerical finite element model which is composed of totally 1179 elements off and 8 node blick. We also analyzed the micromotions at the bone-stem interface and mechanical behavior of existing bone prosthesis for a loading condition simulating the single leg stance. The result indicates that the values of relative motion for this well fit Multilock stem were $150{\mu}m$ in maximum, $82{\mu}m$ in minimum, and the largest relative motion developed in medial region of proximal femur with anterior-posterior direction. The proximal region of the bone was much larger in motion than the distal region and the stress pattern shows high stress concentration on the cortex near the tip of the stem. These findings indicates that the loading in the proximal femoral bone in the early postoperative situation can produce micromotions on the interface and clinically cementless TEA patient should not be allowed weight bearing strictly early in the postoperative period.

  • PDF