• Title/Summary/Keyword: Feedforward Compensation

Search Result 123, Processing Time 0.023 seconds

CPSN (complex Pi-sigma network) equalizer for the compensation of nonlinearities in satellite communication channels (위성 통신 채널의 비선형성 보상을 위한 CPSN (Complex Pi-sigma Network) 신경회로망 등화기)

  • 진근식;윤병문;신요안
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.6
    • /
    • pp.1231-1243
    • /
    • 1997
  • Digital satellite communication channels have nonlinearities with memory due to saturation characteristics of traveling wave tube amplifier in the satellite and transmitter/receiver linear filters. In this paper, we propose a network structure and a learning algorithm for complex pi-sigma network (CPSK) and exploit CPSN in the problem of equalization of nonlinear satellite channels. The proposed CPSN is a complex-valued extension of real-valued pi-sigma network that is a higher-order feedforward network with fast learning while greatly reducing network complexity by utilizing efficient form of polynomials for many input variables. The performance of the proposed CPSN is demonstrated by computer simulations on the equalization of complex-valued QPSK input symbols distorted by a nonlinear channel modeled as a Volterra series and additive noise. The results indicate that the CPSN shows good equalization performance, fast convergence, and less computations as compared to conventional higher-order models such as Volterra filters.

  • PDF

Dynamic Analysis and Control Loop Design of ZVS-FB PWM DC/DC Converter (ZVS-FB PWM DC/DC 변환기의 동특성 해석 및 제어기 설계)

  • 이득기;윤길문;차영길;김흥근
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.3
    • /
    • pp.231-239
    • /
    • 1998
  • This paper presents the dynamic analysis and control loop design of a zero voltage switching full bridge (ZVS-FB) PWM DC/DC converter. The small-signal model is derived incorporating the effects of phase shift control and the utilization of transformer leakage inductance and power FET junction capacitance to achieve zero voltage resonant switching. These effects are modeled by introducing additional feedforward and feedback terms for duty cycle modulation. Based on the results of the small-signal analysis, the control loop is designed using a simple two-pole one-zero compensation circuit. To show the validity of the design procedures, the small signal analysis of the closed loop system is carried out and the potential of the zero voltage switching and the superiority of the dynamic characteristics are verified through the experiment with a 2 kW prototype converter.

  • PDF

Active Damping of LCL Filter for Three-phase PWM Inverter without Additional Hardware Sensors (추가적인 센서가 필요 없는 3상 PWM 인버터의 LCL 필터 능동댐핑)

  • An, Byoung-Woong;Shin, Hee-Keun;Kim, Hag-Wone;Cho, Kwan-Yuhl;Han, Byoung-Moon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.10-17
    • /
    • 2013
  • In this paper, a new active damping method of LCL filter without capacitor voltage sensors is proposed for 3 phase PWM Inverter. Normally, L filter or LCL filter is used as an output filter of grid connected PWM inverter. An LCL filter has more excellent performance than L filter to reduce harmonic current, so the small inductance value can be used. However, the resonance problem in LCL filter is happen due to the zero impedance by the addition of LC branch. To solve the resonance problem, the various active damping method has been proposed so far. Generally, the virtual resistor active damping methods is required to additional hardware sensors for measurement of capacitor voltage and current. In this paper, the new active damping method is proposed without any capacitor voltage or current sensors. In the proposed method, the resonance component of the capacitor voltage of LCL filter can be observed by a simple MRAS(Model Reference Adaptive System) observer without additional hardware sensors, and this component is suppressed by feedforward compensation. The validity of the proposed method is proven by simulation and experiment on the 3-phase PWM inverter system.