• Title/Summary/Keyword: Feeder cost

Search Result 68, Processing Time 0.025 seconds

A Study on the Activation Plan of Busan Port (Focused on northeast feeder network service cost, From LA to China and Japan)

  • Han, Yu-Nam;Yoon, Mi-Sun;Kang, Dal-Won;Kim, Hyun;Kwak, Kyu-Seok;Nam, Ki-Chan
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2006.10a
    • /
    • pp.203-212
    • /
    • 2006
  • The purpose of this research is to suggest the activation plan of Busan port. In the past years, Busan port enjoyed the golden days because of the China's rapid economic growth. But China's continuous development of ports, the trend of increasing container ship size and increasing direct call to China are coming threats to Busan port. So Korea needs to revise the 'Northeast Logistics Hub' strategy because it is considered that Korea ports continuously will handle China's transshipment cargoes. But now China's transshipment cargo share has decreased by direct call to China ports. It means that China has a lot of its local cargoes, so many ship companies change liner service route to handle China cargoes except Bussan ports although Busan port is included in the main trunk route. In the future, Bussan port will not be able to compete again about throughput with China ports if Busan port's transshipment cargo share decreases. So we must find out and develop Busan port's strength which is the competitive edge. By good luck, Busan port has a few opportunities such as the developed feeder network service and geographical advantages. Busan port has many feeder network service like spider's web in any northeast countries so we can suggest that if Japanese shippers use Busan port to distribute their cargoes to Japanese local areas, its transport costs are cheaper than when they use Japan's main ports. In this paper analyzed side of cost when they use Bussan port like hub to distribute their cargo to their local areas. Because most companies tried to reduce the total cost about logistics. Finally, this paper suggests when northeast shippers(China, Japan) use Bussan port which is more economical than their local main ports.

  • PDF

Study of Drawing Optimum Switch Automation Rate to Minimize Reliability Cost (신뢰도 비용 최소화를 위한 개폐기의 최적 자동화율 도출에 관한 연구)

  • Chai, Hui-seok;Kang, Byoung-wook;Kim, Jin-seok;Moon, Jong-fil;Kim, Jae-chul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.4
    • /
    • pp.297-302
    • /
    • 2015
  • Replacing a manual switch installed in a feeder for a distribution system with an automatic one increases the reliability of the electric power system. This is because the automatic switch can shorten the duration of a fault the customer experiences by splitting the faulty section faster than the manual one does. However, improving the reliability of the distribution system may increase investment costs. Here, the investment costs include automatic switch cost, replacement work cost and labor cost. For this reason, importance should be attached to the proper balance between the increase of the investment costs and the improvement of the reliability of the distribution system. This article analyzed reliability index and economics when manual switches installed in a feeder (RBTS Bus2 model) was replaced by automatic ones. In addition, it attempted to draw the optimum rate of automation of manual switches by automatic ones using the GRG optimization method, considering the current economic requirements.

A Study on the Economical Efficiency of Mega Container Ship's Operation by Empirical Analysis : Primarily on Container Ship (실증분석을 통한 대형선의 운항 경제성에 관한 연구 -컨테이너선을 중심으로-)

  • Song Yong-Seok;Kim Hyun;Jung Seung-Ho;Nam Ki-Chan
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.11a
    • /
    • pp.253-260
    • /
    • 2004
  • In these days, 8000TEU container ship service launches in shipping service at latest based on the economy of scale, unit cast related with ship operation on ocean decreases in proportion to increase of ship scale and mega ship over 10,000TEU is on planning. This paper is analyzed the economic efficiency for reduction qf calling port in the operation cost, port chnrge, feeder cost, etc by an empirical analysis.

  • PDF

Feeder Loop Line Control for the Voltage Stabilization of Distribution Network with Distributed Generators

  • Jeong, Bong-Sang;Chun, Yeong-Han
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.1-5
    • /
    • 2014
  • When renewable sources are connected to the distribution network in the form of a distributed generators(DGs), the effect of intermittent output appears as voltage fluctuation. The surplus power at the consumer ends results in the reverse power flow to the distribution network. This reverse power flow causes several problems to the distribution network such as overvoltage. Application of the reactive power control equipment and power flow control by means of BTB inverter have been suggested as the general solutions to overcome the overvoltage, but they are not economically feasible since they require high cost devices. Herein, we suggest the feeder loop line switch control method to solve the problem.

An Adaptive Genetic Algorithm Based Optimal Feeder Routing for Distribution System Planning (적응 유전알고리즘을 이용한 배전계통 계획의 급전선 최적경로 선정)

  • Kim, Byung-Seop;Kim, Min-Soo;Shin, Joong-rin
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.2
    • /
    • pp.58-66
    • /
    • 2001
  • This paper presents an application of a newly designed Adaptive Genetic Algorithm (AGA) to solve the Optimal Feeder Routing (OFR) problem for distribution system planning. The main objective of the OFR problem usually is to minimize the total cost that is the sum of investment costs and system operation costs. We propose a properly designed AGA, in this paper, which can handle the horizon-year expansion planning problem of power distribution network in which the location of substation candidates, the location and amount of forecasted demands are given. In the proposed AGA, we applied adaptive operators using specially designed adaptive probabilities. we also a Simplified Load Flow (SLF) technique for radial networks to improve a searching efficiency of AGA. The proposed algorithm has been evaluated with the practical 32, 69 bus test system to show favorable performance. It is also shown that the proposed method for the OFR can also be used for the network reconfiguration problem in distribution system.

  • PDF

Leadframe Feeder Heat Rail Design and Verification (Leadframe Feeder Heat Rail의 설계와 검증)

  • Kim, Won-Jong;Hwang, Eun-Ha
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.15 no.1
    • /
    • pp.37-42
    • /
    • 2012
  • Trends in semiconductor equipment industry are to reduce the cost of producing semiconductor, semiconductor process development, facility development, and the minimum investment in terms of cost and quality. Semiconductor equipments are being considered to review and development is proceeding at the same time. In the first part of the semiconductor assembly process, in which the importance of die bonding process is emerging, a wide leadframe type die bonding machine is demanded for productivity. Die bonding machine was designed through experiments and by trial and error. It costs a lot of time and financial burden. The purpose of this study is to solve these problems by using the CAE tool 3G. By using finite element method, thermal analysis of die bonding machine to the various widths leadframe die bonder machine rail is performed for design.

A Case Study on a Way of Improving the Grand Alliance Container Service Route by Incorporating Dedicated Feeders - Focusing on 'Far East-West Coast of North America' Route - (전용 피더 서비스 연계를 통한 Grand Alliance 컨테이너 서비스 항로의 운영 개선에 관한 사례 연구: '극동-북미서안' 컨테이너 서비스 항로를 중심으로)

  • Kim, Woo-Jin;Shin, Jeong-Hoon;Chang, Myung-Hee
    • Journal of Navigation and Port Research
    • /
    • v.36 no.5
    • /
    • pp.409-418
    • /
    • 2012
  • Amid global economic crisis and skyrocketing oil prices, container shipping companies have raised a sustained series of efforts to reduce vessel operating costs. Under these circumstances, the Grand Alliance has decided to install the dedicated feeder instead of additional vessels in the CCX(Central China Express) and the NCE(North China Express) route. In other words, a vessel in a trunk route is transshiped by a dedicated feeder vessel in Busan port that is a transshipment port, rather than calling at Northen China port. In this study, the actual operating data of Grand Alliance container services were analyzed to determine the economic effect of transshipment through a dedicated feeder service. In this way, the Grand Alliance are saving vessel operating expenses in 'NCE' and 'CCX' routes, making the slow steaming of vessels possible in these trunk routes.

A Study on Total Mixed Ration Feeding System for Feeding Pigs (1) - Development of Monorail Traveling TMR Feeder for Grow-Finish Pigs -

  • Kim, Hyuck Joo;Yu, Byeong Kee;Hong, Jong Tae;Choi, Kyu Hong;Yu, Ji Su;Hong, Youngsin;Ha, Yu Shin
    • Journal of Biosystems Engineering
    • /
    • v.38 no.4
    • /
    • pp.295-305
    • /
    • 2013
  • Purpose: Recent research showed that total mixed ration (TMR) feeding for pigs improved the productivity and reduced feed cost and manure odor. An automatic TMR feeding system was developed for this study because the conventional feeder cannot deliver the TMR containing roughage. Methods: Conventional feeding systems and physical properties of TMR were surveyed, and performance tests of the conventional feeder were conducted to develop a TMR feeder. Based on the TMR feeder was developed and installed, driving, measuring weight, radio frequency identification (RFID) reading, and discharging test for feeding were conducted to ensure the performance. Results: Moisture content, density, and angle of repose of the TMR 1 (mixture of 30% cut IRG silage and 70% concentrates) were 31.6%, 387 $kg/m^3$, and $51^{\circ}$, respectively. Moisture content, density, and angle of repose of the TMR 2 (mixture of 45% concentrates, 30% cut IRG silage and by-products, 10% bean curd refuse, 10% others, and 5% fermenter) were 22.2%, 544 $kg/m^3$, and $50^{\circ}$, respectively. The coefficient of variation (C.V.) of conventional concentrate feeding were 1.9~4.1%, and C.V. of TMR containing 1~3% cut IRG roughage feeding by conventional feeder were 9~42%. The conventional disc type feeder was not suitable for TMR feeding because the supply unit was clogged. The C.V. of TMR 1 was 0.6~7.9% when 0.5~10 kg of the TMR supplied, and it was suitable for feeding grow-finish pigs and sows. On the contrary, the C.V. with TMR 2 was 28% when 0.5 kg of the TMR supplied, and it was not suitable for feeding sows. Conclusions: The TMR feeder developed in this study was suitable for feeding grow-finish pigs because the feeder performed stably with over 5.0 kg feed. However, the feeder showed a lack of accuracy for feeding sows because the amount of each feed was more than 0.5 kg per a feeding. Therefore, the improvement of outlet structure for accurate feeding is needed for sow feeding.

Study on the algorithm for the Reasonable Switch Automation Rate with Customer Interruption Cost and Reliability Evaluation (정전비용과 신뢰도 분석을 통한 분할 개폐기의 적정 자동화율 도출 알고리즘에 관한 연구)

  • Chai, Hui-Seok;Shin, Hee-Sang;Cho, Sung-Min;Moon, Jong-Fil;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.4
    • /
    • pp.467-473
    • /
    • 2013
  • The addition of disconnect switches to a distribution feeder or the replacement of the manual switches with the automatic switches do, in general, increase reliability by decreasing the duration of the outage of many to the customers on the feeder and reducing the outage section. However, the improvement of reliability in power distribution system causes an increase of the investment cost, for example, replacement costs, labor costs, and so on. For this reason - the balance between investment and reliability improvement - many studies about the appropriate level of investment have been conducted. In this paper, we suggest the algorithm for determining the reasonable switch automation rate in the power distribution system. We evaluate the customer interruption cost and reliability for several cases - these cases relate with the switch automation rate - in the domestic metropolitan power distribution system, estimate the effectiveness of changing the manual switch to automatic switch quantitatively. These results can help the determining on the disconnect switch's automation rate.