• Title/Summary/Keyword: Feeder Charge

Search Result 9, Processing Time 0.021 seconds

Modal Analysis of Bowl Parts Feeder Activated by Piezoactuators (압전작동기로 구동되는 원통형 Parts Feeder의 모드 해석)

  • 최승복;이동호;김재환;정재천
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.432-437
    • /
    • 1998
  • This paper presents modal characteristics of bowl parts feeder featuring piezoelectric actuators. As wellknown, the piezoelectric materials develop an electric charge proportional to a mechanical stress and vice versa. This generic phenomenon allows us to use the piezoelectric materials as sensors and actuators. Using the actuating property, we can device effective bowl parts feeder. The parts feeder activated by the piezoceramic actuators provides a large degree of freedom of controlling excitation magnitude and frequency, and thus accurate and fast feeding of various parts. As a first phase to demonstrate these advantages, a finite clement model of the bowl parts feeder is constructed and analyzed using commercial software packages. In addition, the simulated modal characteristics are compared with the measured ones to validate the proposed model.

  • PDF

Economic Evaluation far the Application of the Distribution Automation System (배전자동화시스템 적용을 위한 경제성 평가)

  • Hong, Soon-Hak;Ha, Bok-Nam;Kim, Ho-Yong;Jung, Kyung-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.36-38
    • /
    • 1993
  • This study considers the economic aspect of the distribution automation system, which is the decision-making criteria of the electric utilities for the investment. The feeder automation candidate region is divided into two types of the urban and the rural. The total investment cost of the feeder automation for each type is estimated. The annual cost, is also estimated, by finding the fixed charge rate. To compare the annual cost and the economic effect cost, for the investment decision-making, the costs are quantitatively estimated on the following effects : the manpower replacement, the outage cost saving, the main transformer utilization improvement, the feeder utilization improvement, and the line loss reduction.

  • PDF

Economic analysis by reduction of calling port and mega containership (선박 대형화 및 기항지 축소에 따른 경제성 분석)

  • 남기찬;곽규석;송용석;김태원;오효진
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.04a
    • /
    • pp.413-419
    • /
    • 2004
  • In these days, 8,000TEU container ship service launches in shipping service at latest based on the economy of scale, unit cost related with ship operation on ocean decreases in proportion to increase of ship scale and mega ship over 10,000TEU is on planning. Most of the exiting researches have performed from the perspective of total operation cost from mega port to mega port. However, the purpose of this paper is to estimate economic efficiency by ports selected Hub port from total cost point of view, operation cost, port charge, feeder cost, etc.

  • PDF

A Study on the Economical Efficiency of Mega Container Ship's Operation by Empirical Analysis : Primarily on Container Ship (실증분석을 통한 대형선의 운항 경제성에 관한 연구 -컨테이너선을 중심으로-)

  • Song Yong-Seok;Kim Hyun;Jung Seung-Ho;Nam Ki-Chan
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.11a
    • /
    • pp.253-260
    • /
    • 2004
  • In these days, 8000TEU container ship service launches in shipping service at latest based on the economy of scale, unit cast related with ship operation on ocean decreases in proportion to increase of ship scale and mega ship over 10,000TEU is on planning. This paper is analyzed the economic efficiency for reduction qf calling port in the operation cost, port chnrge, feeder cost, etc by an empirical analysis.

  • PDF

Performance Analysis for Regenerative Energy Storage System in Kyoung-bu High Speed Railway (경부고속철도 회생 에너지 저장시스템 성능 분석)

  • Jang, Min-Ju;Jeon, Yong-Joo;Lho, Young Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.9
    • /
    • pp.1391-1397
    • /
    • 2015
  • Recently, various researches are conducted in the application of regenerative energy produced during the operation of an electric locomotive. Regenerative energy is produced by a generator in the brake procedure. The generator is operated by kinetic energy of an electric railroad using an electric motor. The process of producing regenerative energy varies with the current type of a railroad and its running condition. The quality of electric power can be improved and electric energy can be utilized effectively, especially in the use of an energy storage system (ESS). Thus, it is necessary to apply ESS into AC section and high speed railway. This study analyses the composition of the regenerative ESS equipment installed in Yong-Jeong sectioning post, operational principle, charge and discharge algorithm and energy efficiency. The analysis shows that CO2 emissions can be reduced about 0.5 ton per a day. In addition, ESS helps saving the energy and the compensation of the voltage drop caused by the operation of high speed train when it is installed at the end of the feeder section. The number of high speed train will be increased continuously related to the electrification rate. Therefore, applying the ESS to high speed railway is expected to solve the instability of the feeder voltage and the equipment capacity problem caused by the high speed trains.

Total Cost Analysis by Calling Port Reduction of Mega Containership - The Case of Domestic Shipping Company - (초대형 컨테이너선의 기항지 축소에 따른 총 비용 분석 - 국내 선사 사례를 중심으로 -)

  • Nam Ki-Chan;Song Yong-Seok;Kim Tae-Won
    • Journal of Navigation and Port Research
    • /
    • v.30 no.1 s.107
    • /
    • pp.53-59
    • /
    • 2006
  • Recently, 8,000TEU class containerships has started operating the shipping service and the mega-containership of over 10,000TEU is on planning. A unit cost in relation to shipping service is decreased by the bigger ship based on the economy of scale. Most of the previous studies have been performed and focused on the total operation cost from mega port to mega port. However, the purpose of this paper is to estimate economic efficiency of selected hub ports from point of view of total cost such as service cost(or operation cost), port charge and feeder cost, etc. First, the service-network of mega containerships is based on data of a domestic shipping company operated main line and economic analysis of individual scenarios on the cost and traffic when 10,000TEU mega containerships offer the services. The three scenarios presented in this paper set up the hub ports which are the port of Busan, Shanghai and Yokohama The results show that port of Busan is economically the most efficient one among others.

An Analysis of Container Terminal Facilities Leasing Fee by Assessing Total Sea-Transportation Costs (총 해상운송비용 평가를 통한 컨테이너터미널 전대사용료 분석)

  • Kim, Hyun
    • Journal of Navigation and Port Research
    • /
    • v.28 no.8
    • /
    • pp.709-714
    • /
    • 2004
  • This paper first tries to analyze total sea transport costs for the transshipment in Busan Port in comparison with direct transport to 4 Chinese Ports, Dalian, Tinajin, Qingdao and Shanghai, based on vessel operation scenarios. The results found that the transshipment in Busan port for the 4 Chinese ports are more expensive than the direct calling to the 4 ports, which implies that Busan port needs to make compensation as an incentive to the carriers providing transshipment service to it in order to keep their royalty. For the compensation, it suggested a method of calculating the Container Terminal Facilities Leasing Fee to levy additional revenue by port authority.

A Study on Economical efficiency Analysis by Handling Capacity and the Size of Container Terminal (컨테이너 터미널의 하역능력과 규모에 따른 경제성 분석에 관한 연구)

  • Woo Seung-Hwa;Song Yong-Seok;Nam Ki-Chan;Kwak Kyu-Seok
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.11a
    • /
    • pp.127-132
    • /
    • 2004
  • Most q the domestic container terminals are inferior to throughput q container. The reason why they have the difference between the handling capacity q planed quay and its real. By putting into quay handling equipment, the productivity of quay can be improved, waiting rate q the ship can be lowed. This paper suggests more resonable terminal construction, throughout comparing with previous construction way, improved handling capacity and the economical efficiency of equipment costs, labor costs, construction costs, operation costs on change of terminal size by adding the equipment.

  • PDF

DC Traction Regenerative Energy Storage Devices using Super-capacitor (슈퍼 커패시터를 이용한 직류철도 회생에너지 저장장치)

  • Kim, Jong-Yoon;Jung, Doo-Yong;Jang, Su-Jin;Lee, Byoung-Kuk;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.247-256
    • /
    • 2008
  • Regenerative energy generated by regenerative braking of DC traction can cause the system malfunction or damage to the rectifier, or malfunction of the power conversion device in power supply system by DC Line voltage rise in feeder line. Regenerative energy storage system using super capacitor is one of the ways to stabilize DC line voltage. In this paper, energy storage system of DC traction system using super-capacitor bank is implemented and using the field measurement data of the station N and the station S on the Line 2, the operation characteristics of line voltage caused by regenerative energy of electric trains are verified. Also, charge/discharge characteristics of super capacitor are verified as well. Thus, we can verify the operation characteristics of super-capacitor bank for regenerative energy storage system installed in DC Traction. And if we can use field measurement data of DC line voltage, we have obtained cost reduction. The stabilization of the system will be improved by measuring the operation characteristics of regenerative energy storage system in certain section operated by DC traction and predicting the capacity and lifetime of super-capacitor.