• 제목/요약/키워드: Feed-forward method

검색결과 218건 처리시간 0.026초

GA-based Feed-forward Self-organizing Neural Network Architecture and Its Applications for Multi-variable Nonlinear Process Systems

  • Oh, Sung-Kwun;Park, Ho-Sung;Jeong, Chang-Won;Joo, Su-Chong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제3권3호
    • /
    • pp.309-330
    • /
    • 2009
  • In this paper, we introduce the architecture of Genetic Algorithm(GA) based Feed-forward Polynomial Neural Networks(PNNs) and discuss a comprehensive design methodology. A conventional PNN consists of Polynomial Neurons, or nodes, located in several layers through a network growth process. In order to generate structurally optimized PNNs, a GA-based design procedure for each layer of the PNN leads to the selection of preferred nodes(PNs) with optimal parameters available within the PNN. To evaluate the performance of the GA-based PNN, experiments are done on a model by applying Medical Imaging System(MIS) data to a multi-variable software process. A comparative analysis shows that the proposed GA-based PNN is modeled with higher accuracy and more superb predictive capability than previously presented intelligent models.

철도차량용 보조전원장치의 전향제어를 이용한 Flicker 제어 (The Flicker Control by Feed-forward for Stabilization of CVCF Inverter)

  • 박채운;신형진;조국춘;원충연
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 추계학술대회 논문집
    • /
    • pp.267-272
    • /
    • 1999
  • The auxiliary power supply system fur passenger service of railway car has been developed from MA(Motor-Alternator) to CVCF Inverter (Static Inverter). Generally, a customer wants to apply tile new control method and device for auxiliary power supply of railcar However, if the auxiliary power supply is supplied to extended existing line, the maintenance cost of the old system is less expensive than new developed system, so, the customer specifies that the auxiliary power supply has compatibility with existing one completely. At that time, the hardware is nearly same as existing system except small changes of accessories for better performance. This paper describes the flicker control using feed-forward method of auxiliary power supply system for new 50 electric railcars, which are delivered to Korean National Railroad (KNR) Kwa-chon Line. The existing power supply system has damping resistor box to stabilize the DC input (1.5 ㎸). At this time, for better system efficiency the new system has not include resistor box but new control method including feed-forward control is applied. This control algorithm realizes the better stabilization of input power compared to the result of the existing system, which includes resistor box

  • PDF

Advanced RMS Calculation Method for the ITER CS, VS1, CC AC/DC Converter

  • 김승민;서재학;박형진;오종석;유민호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.301-302
    • /
    • 2019
  • ITER CS, VS, CC AC/DC Converter는 4상한 동작을 하며, PCS(Plasma Control System)에서 명령하는 출력 전압 제어를 컨버터 교류 입력 전압 변동을 보상하는 Feed-forward 방식을 사용한다. Feed-forward 제어를 위하여 교류 입력 전압에 대한 실시간 정밀 측정이 가능한 RMS 계산이 필요하다. 본 논문은 RMS 연산에 대한 개선된 방법을 제안하면서 시뮬레이션과 실험을 통해 해당 알고리즘을 검증하였고 이에 대한 내용을 논의하고자 한다.

  • PDF

부하전류 전향보상기를 이용한 강압쵸퍼의 동특성 항상 (Dynamic Characteristics Improvement of a Step-Down Chopper Using Load Current Feed-Forward Compensator)

  • 전지용;전기영;정춘병;한경희
    • 조명전기설비학회논문지
    • /
    • 제22권12호
    • /
    • pp.29-35
    • /
    • 2008
  • 본 논문에서는 부하전류의 급격한 변화에도 안정적인 출력진압을 얻기 위하여 강압쵸퍼의 전압제어 기를 개선하는 방법으로 부하전류 전향보상기를 제시하였다. 제시된 부하전류 전향보상기의 특성을 확인하기 위해 메이슨(Mason)의 이득공식을 이용하여 기존의 전압제어기가 포함된 전체 시스템의 전달함수와 부하전류 전향보상기가 추가된 전체 시스템의 전달함수를 각각 근궤적선도와 보드선도 상에서 비교하였다. 그 결과 시스템의 극점이 개선되고, 공진주파수에서의 첨두값의 크기 및 절점주파수의 위상여유가 양호한 것을 확인하였다. 따라서, 제시된 제어기법이 강압쵸퍼의 정상상태 및 동특성을 향상시키고 출력에 나타나는 외란에 의한 영향을 감소시킨 것을 확인할 수 있었다.

외란관측기를 이용한 영구자석 동기전동기에 대한 참조모델 견실적응 제어기의 성능개선 (Performance Enhancement of RMRAC Controller for Permanent Magnet Synchronous Motor using Disturbance Observer)

  • 김홍철;임훈;이장명
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.67-69
    • /
    • 2007
  • PMSM (Permanent Magnet Synchronous Motor) current control is a most inner loop of electromechanical driving systems and it plays a foundation role in the hierarchy's control loop of several mechanical machine systems. In this paper, a simple RMRAC control scheme for the PMSM is proposed in the synchronous frame. In the synchronous current model, the input signal is composed of as a calculated voltage by adaptive laws and system disturbances. The gains of feed-forward and feed-back controller are estimated by the proposed e-modification methods respectively, where the disturbances are assumed as filtered current tracking errors. After the estimation of the disturbances from the tracking errors, the corresponding voltage is fed forward to control input to compensate for the disturbances. The proposed method is robust to high frequency disturbances and has a fast dynamic response to time varying reference current trajectory. It also shows a good real-time performance duo to it's simplicity of control structure. Through the simulations considering several cases of external disturbances and experimental results, efficiency of the proposed method is verified

  • PDF

Precise Modeling and Adaptive Feed-Forward Decoupling of Unified Power Quality Conditioners

  • Wang, Yingpin;Obwoya, Rubangakene Thomas;Li, Zhibo;Li, Gongjie;Qu, Yi;Shi, Zeyu;Zhang, Feng;Xie, Yunxiang
    • Journal of Power Electronics
    • /
    • 제19권2호
    • /
    • pp.519-528
    • /
    • 2019
  • The unified power quality conditioner (UPQC) is an effective custom power device that is used at the point of common coupling to protect loads from voltage and current-related PQ issues. Currently, most researchers have studied series unit and parallel unit models and an idealized transformer model. However, the interactions of the series and parallel converters in AC-link are difficult to analyze. This study utilizes an equivalent transformer model to accomplish an electric connection of series and parallel converters in the AC-link and to establishes a precise unified mathematical model of the UPQC. The strong coupling interactions of series and parallel units are analyzed, and they show a remarkable dependence on the excitation impedance of transformers. Afterward, a feed-forward decoupling method based on a unified model that contains the uncertainty components of the load impedance is applied. Thus, this study presents an adaptive method to estimate load impedance. Furthermore, simulation and experimental results verify the accuracy of the proposed modeling and decoupling algorithm.

단상 PVPCS 출력 전류의 리플 개선을 위한 노치 필터 및 피드 포워드 제어기 설계 (The Feed-forward Controller and Notch Filter Design of Single-Phase Photovoltaic Power Conditioning System for Current Ripple Mitigation)

  • 김승민;양승대;최주엽;최익;이영권
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.325-330
    • /
    • 2012
  • A single-phase PVPCS(photovoltaic power conditioning system) that contains a single phase dc-ac inverter tends to draw an ac ripple current at twice the out frequency. Such a ripple current may shorten passive elements life span and worsen output current THD. As a result, it may reduce the efficiency of the whole PVPCS system. In this paper, the ripple current propagation is analyzed, and two methods to reduce the ripple current are proposed. Firslyt, this paper presents notch filter with IP voltage controller to reject specific current ripple in single-phase PVPCS. The notch filter can be designed that suppress just only specific frequency component and no phase delay. The proposed notch filter can suppress output command signal in the ripple bandwidth for reducing output current THD. Secondly, for reducing specific current ripple, the other method is feed-forward compensation to incorporate a current control loop in the dc-dc converter. The proposed notch filter and feed-forward compensation method have been verified with computer simulation and simulation results obtained demonstrate the validity of the proposed control scheme.

  • PDF

신호 제거 궤환부의 전류 제어 적응형 알고리즘을 이용한 IMT-2000용 선형화 증폭기 제작 (Fabrication of IMT-2000 Linear Power Amplifier using Current Control Adaptation Method in Signal Cancelling Loop)

  • 오인열;이창희;정기혁;조진용;라극한
    • 대한전자공학회논문지TC
    • /
    • 제40권1호
    • /
    • pp.24-36
    • /
    • 2003
  • IMT-2000 서비스의 전송제한은 3GPP에 규정하고 있다. IS-95A 서비스보다 IMT-2000 서비스는 3배의 대역폭을 가짐으로 해서 Peak to Average가 높아졌고, 이 때문에 인접채널에 대한 영향을 줄이는 쪽으로 더 주위 깊게 설계하여야 하는 어려움이 발생하였다. 이러한 요소에 가장 민감하게 동작하는 모듈이 이동통신 시스템에 최종단에 위치하여 멀리까지 서비스를 가능케 하는 HPA(High Power Amplifier)이다. HPA는 Pl㏈ 근처에 동작시킴으로 인해 3차 5차 신호로 인해 인접채널에 영향을 미치며, 신호가 포화됨으로 인해 왜곡이 발생한다. 이에 HPA를 어떻게 선형화 시킬 수 있을 것이냐가 중요한 요소로써 작용하는데, 본 논문에서는 가장 복잡한 구조로 이루어져 있지만 선형화 방법에 있어 탁월한 개선 능력을 갖는 Feed-forward 방식을 설계 제작하였다. 본 논문은 Feed-forward의 1차 궤환부인 신호 제거 궤환부에서 얻어진 전류를 검출하여 알고리즘을 수행케 함으로써 환경변화에서도 무리 없이 동작하는 적응형 40Watt Feed-forward 선형화 증폭기가 되도록 하였다. 일반적인 RF 출력 신호를 검출하는 방식은 회로가 복잡하며, 합성기 출력에서 검출을 하기 때문에 신호검출의 정확성에서도 떨어지는 단점이 있다. 또한 선형화 증폭기의 최종 출력에서의 에러 신호를 감지하여 최적화시키는 알고리즘 역시 기존 방식인 Pilot 신호를 이용하지 않고 에러량 검출 방식을 적용하셔 W-CDMA용 선형화 증폭기가 되도록 하였다. 결과적으로 54㏈의 이득특성을 얻으면서 IW에서 40W 출력시까지 어느 동작에서도 30㎑ 대역폭 내에서 -26㏈m Max@3.515㎒ ACPR(Adjacent Channel Power Ratio) 특성, 48㏈c Max@±5㎒ ACLR (Adjacent Channel Leakage Power Ratio) 특성을 모두 만족하여 3GPP의 국제규격을 만족하는 선형화 증폭기가 되도록 하였다.

보정된 전류동역학에 기반한 영구자석 전동기의 참조모델 강인적응제어기 (An RMRAC Controller for Permanent Magnet Synchronous Motor Based On Modified Current Dynamics)

  • 김홍철;이장명
    • 제어로봇시스템학회논문지
    • /
    • 제14권10호
    • /
    • pp.991-997
    • /
    • 2008
  • A new RMRAC scheme far the PMSM current regulation is proposed in a synchronous frame, which is completely free from the parameter's uncertainty. A current regulator of PMSM is the inner most loop of electromechanical driving systems and plays a foundation role in the control hierarchy. When the PMSM runs in high speed, the cross-coupling terms must be compensated precisely for large system BW. In the proposed RMRAC, the input signal is composed of a calculated voltage defined by MRAC law and an output of the disturbance compensator. The gains of feed forward and feedback controller are estimated by the proposed modified gradient method, where the system disturbances are assumed as filtered current regulation errors. After the compensation of the system disturbance from error information, the corresponding voltage is fed forward to control input to compensate for real disturbances. The proposed method robustly compensates the system disturbance and cross-coupling terms. It also shows a good realtime performance due to the simplicity of control structure. Through real experiments, the efficiency of the proposed method is verified.

하수방류수의 전처리 조건별 FO막의 운전성능평가 (Evaluation of FO membrane performance for each type of pre-treatment from WWTP secondary effluents)

  • 정준원;김지훈;김건엽;박준영;김형수;김형숙
    • 상하수도학회지
    • /
    • 제30권2호
    • /
    • pp.131-137
    • /
    • 2016
  • The development of alternative water resources has emerged as an effective method for solving drought of water resources due to extreme weather and increase in water consumption. Recently, in Korea, there has been active research on reverse osmosis desalination technology, wastewater reuse using forward osmosis membranes, and the forward osmosis(FO)-reverse osmosis(RO) hybrid process combining these two technologies. In this study, the basic performance of FO membranes manufactured by three domestic and international manufactures such as Microfilter Co., Ltd., Toray Chemical Korea Inc., and Hydration Technologies Inc., were investigated for wastewater reuse. In addition, as an experiment to select feed solution, the selected membranes were operated 48 consecutive hours using three secondary effluents pretreated by the UF membrane with a pore size of $0.1{\mu}m$ and auto strainer with pore sizes of $1{\mu}m$ and $100{\mu}m$ as feed solution. Although there was not much difference in the operating performance. Thus, the treated water using the $100{\mu}m$ auto strainer was selected as feed solution applied to the assessment.