• Title/Summary/Keyword: Feed-Through Voltage

Search Result 64, Processing Time 0.025 seconds

A Study on the High-Efficiency. High-Power-Factor AC/DC Boost Converter Using Energy Recovery (에너지 회생 스너버를 적용한 고효률, 고역률 AC/DC Boost 컨버터에 관한 연구)

  • Ryu, Chang-Gyu;Kim, Yong;Bae, Jin-Yong;Baek, Soo-Hyun;Choi, Geun-Soo;Gye, Sang-Bum
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.160-163
    • /
    • 2004
  • A passive lossless turn-on/turn-off snubber network is proposed for the boost PWM converter. Previous AC/DC PFC Boost Converter perceives feed forward signal of output for average current-mode control. Previous Boost Convertor, the Quantity of input current will be decreased by the decrease of output current in light load, and also Power factor comes to be decreased. Also the efficiency of converter will be decreased by the decrease of power factor. The proposed converter presents the good PFC, low line current harmonic distortions and tight output voltage regulations using energy recovery circuit. All of the semiconductor devices in the converter are turned on under exact or near zero voltage switching(ZVS). No additional voltage and current stresses on the main switch and main diode occur. To show the superiority of this converter is verified through the experiment with a 640W, 100kHz prototype converter.

  • PDF

Studies of Performance and Enlarged Capacity through Multi-stages Stacked Module in Membrane Capacitive Deionization Process (막 축전식 탈염 공정의 다단 적층 모듈을 통한 처리 용량 증대 및 이의 성능 연구)

  • Song, Yye jin;Yun, Won Seob;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.27 no.5
    • /
    • pp.449-457
    • /
    • 2017
  • In this study, the 10 stages stacked module was designed by increasing the number of unit cells in the membrane capacitive deionization(MCDI) process. The aminated polysulfone and sulfonated poly(ether ether ketone) were synthesized and coated on porous carbon electrode by casting method. The salt removal efficiency was measured for the 10 stage stacked module under the operation conditions of adsorption voltage and time, desorption voltage and time, flow rate and concentration of feed water, and di-valent solutions including $CaSO_4$, $MgCl_2$ and tap water. Typically, when 100 mg/L of NaCl as the feed was used, the salt removal efficiency was 98.3% at a flow rate of 100 mL/min, the adsorption condition of 1.2 V/3 min and desorption condition of -0.5 V/5 min.

Simulations of Gate Driving Schemes for Large Size, High Quality TFT-LCD (대면적 고화질 TFT-LCD용 게이트 Driving에 관한 Simulation)

  • Jung, Soon-Shin;Yun, Young-Jun;Kim, Tae-Hyung;Choi, Jong-Sun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1809-1811
    • /
    • 1999
  • In recent years, attempts have been made to greatly improve the display quality of active-matrix liquid crystal display devices, and many techniques have been proposed to solve such problems as gate delay, feed-through voltage and image sticking. Gate delay is one of the biggest limiting factors for large-screen-size, high-resolution thin-film transistor liquid crystal display (TFT/LCD) design. Many driving method proposed for TFT/LCD progress. Thus we developed gate driving signal generator. Since Pixel-Design Array Simulation Tool (PDAST) can simulate the gate, data and pixel voltages of a certain pixel on TFT array at any time and at any location on an array, the effect of the driving signals of gate lines on the pixel operations can be effectively analyzed.

  • PDF

Decoupled Control of Doubly Fed Induction Machine Fed by SVM Matrix Converter

  • Dendouga, Abdelhakim;Abdessemed, Rachid;Bendaas, Mohamed Lokmane
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.4
    • /
    • pp.491-498
    • /
    • 2008
  • In this paper a decoupled control of a doubly-fed induction machine(DFIM) feed by a matrix converter is presented. It provides a robust regulation of the stator side active and reactive powers by the direct and quadratic components of the stator current vector, presented in a line-voltage-oriented reference frame. In this case, the stator windings are directly connected to the line grid, while the rotor windings are supplied by this later through a matrix converter controlled by a space vector modulation technique. The proposed solution is suitable for both energy generation and electrical drive applications with restricted speed variation range.

A Study on the High-Power-Factor, High-Efficiency AC/DC Boost Converter with Non-Dissipative Snubber (무손실 스너버를 적용한 고역률, 고효률 AC/DC Boost 컨버터에 관한 연구)

  • Bae, Jin-Yong;Kim, Yong;Baek, Soo-Hyun;Kwon, Soon-Do
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.112-115
    • /
    • 2002
  • Previous AC/DC PFC Boost Converter perceives feed forward signal of input and feedback signal of output for average current-mode control. Previous Boost Converter, the quantity of input current will be decreased by the decrease of output current in light load, and also power factor comes to be decreased. Also the efficiency of converter will be decreased by the decrease of power factor. The proposed converter presents the good PFC(Power Factor Correction), low line current hormonic distortions and tight output voltage regulations using non-dissipative snubber. The proposed converter also has a high efficiency by non-dissipative snubber circuit. To show the superiority of this converter is verified through the experiment with a 640W, 100kHz prototype converter.

  • PDF

Real-Time Estimation of the Boost Inductance in a Single-phase AC/DC parallel PWM converter for High-speed EMU (동력분산형 고속철도의 단상 병렬 AC/DC PWM 컨버터를 위한 승압형 인덕턴스의 실시간 추정)

  • Jung, Hwan-Jin;Park, Byoung-Gun;Hyun, Dong-Seok
    • Proceedings of the KSR Conference
    • /
    • 2009.05b
    • /
    • pp.259-264
    • /
    • 2009
  • This paper proposes a real-time estimation of the boost inductance in a single-phase AC/DC parallel PWM converter for high-speed EMU. The estimation procedure of the boost inductance is only based on the variation of input current and the input AC voltage measurement. The estimated boost inductance is optimized by the least square method. This estimation technique can improve the performance of current controller and reduce the harmonics of the input current in the feed-forward controller. The validity of proposed technique is verified through the MATLAB SIMULINK simulation results.

  • PDF

A Fully Digital Controlled Fly-back Single Stage Power Supply Unit for the Wireless Dimming System of LED Lightings

  • Oh, Yongseung;In, Chigak;Cho, Kyumin
    • Journal of Advanced Information Technology and Convergence
    • /
    • v.9 no.2
    • /
    • pp.75-87
    • /
    • 2019
  • This paper presents a fully digital controlled power supply unit for the wireless controlled dimmable LED lighting system. The proposed power supply designed using a fly-back converter, which is directly controlled by a microprocessor. Although the proposed circuit does not sense the AC input current and has not AC input voltage feed-forward, it can achieve a high power factor. The proposed power supply directly regulates the output power for LED loads using the PWM and PFM control of the fly-back converter without additional regulator. For a wireless remote control function, the Zigbee modem is equipped in the proposed power supply. A prototype set-up has been built and tested. Through the experiment with a prototype set-up, the usefulness of the proposed power supply is verified.

Development of a frequency-to-voltage transducer in a motor (모터의 회전수-전압 변환장치 개발)

  • 김강철
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.3
    • /
    • pp.563-572
    • /
    • 2001
  • A conventional motor in a crane has a taco generator to feed back the number of turns to a main controller. The taco generator is contacted to a motor shaft through the coupling. Errors in a crane have often occurred because the coupling has worn out while the motor is turning. In this paper, we design the device of the frequency to voltage transducer in a motor. The device is composed of a rotary encoder, a speed measurement using PIC16F84 controller, a display, and a direction-decision block. The rotation of a motor is recognized by the rotary encoder and microcontroller counts the number of turns of a motor. The emergency signal is generated if the frequency goes over or below the speed limit of a motor. And the device can acknowledge the rotation direction of the motor after 6。 rotation. The simulation results and the test for a implemented device have shown that the transducer of a frequency to a voltage can replace a taco generator in a crane.

  • PDF

Linear Tapered Slot Rectifying Antenna for Portable UHF-Band RFID System (휴대용 UHF대역 RFID 시스템을 위한 선형 테이퍼드 슬롯 정류 안테나)

  • Pyo, Seongmin
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.368-371
    • /
    • 2020
  • In this paper, we propose a linear tapered slot rectifying antenna for a portable UHF-band RFID system. Since the proposed rectifying antenna does not use a dielectric substrate, the planar antenna is implemented with a thin metal thickness. The rectifier circuit converts input RF power into output DC voltage using a voltage doubler circuit based on two anti-parallel schottky diodes. The rectifying antenna is integrated by the voltage doubler circuit into a linear tapered slot antenna. For conjugate impedance matching of the rectifying circuit and the linear tapered slot antenna, the source-pull method was utilized by adjusting the angle of the tapered slot and the length of the antenna feed line. The proposed antenna prototype has been verified with the electrical and radiation characteristics through RF-DC conversion and far-field radiation test in open space measurement environment. Finally, the proposed antenna is realized to 0.23-wavelength (75 mm) and 0.18-wavelength (60 mm) at 915 MHz center frequency.

Inspection about Influences on the Weld Parts through the Change of the Position of Welding Torch and the Voltage During CO2 Welding (CO2용접에서 용접 토치의 위치변화와 전압이 용접부에 미치는 영향고찰)

  • Kim, Bub-Hun;Kim, Won-Il;Lee, Chil-Soon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.14 no.2
    • /
    • pp.59-65
    • /
    • 2011
  • $CO_2$ Welding which uses $CO_2$ instead of inert gas is most widely used in industrial sites. Welding rod for $CO_2$ Welding is roughly divided into solid wire and flux cored wire. $CO_2$ Welding has higher efficiency than any other welding methods, and also economic and speedy to handle, that's why is used frequently for welding general structures. As most of studies about $CO_2$ Welding are focused on metallurgical changes of successful joints, they developed theories about the change of configuration on weld parts. This study is especially focused on not only the change of configuration on weld parts, but also the change of the penetrating depth through changing the position of welding torch. For inspection, applied AWS A5.20 E70-1 among welding wires and fixed moving angles of torch, but controled the values of voltage and the position of welding. Also Automatic Feed Mechanism is used for exact movement of material, specimen is a piece of steel for general structures. By measuring and analyzing the configuration of sliced section and the values of welding leg length and welding throat after welding, the outcome about the changes turned out.