• Title/Summary/Keyword: Feed distance

Search Result 144, Processing Time 0.034 seconds

Shorted Microstrip Patch Antenna Using Inductively Coupled Feed for UHF RFID Tag

  • Kim, Jeong-Seok;Choi, Won-Kyu;Choi, Gil-Young;Pyo, Cheol-Sig;Chae, Jong-Suk
    • ETRI Journal
    • /
    • v.30 no.4
    • /
    • pp.600-602
    • /
    • 2008
  • A very small patch-type RFID tag antenna (UHF band) using ceramic material mountable on metallic surfaces is presented. The size of the proposed tag is 25 mm${\times}$25 mm${\times}$3 mm. The impedance of the antenna can be easily matched to the tag chip impedance by adjusting the size of the shorting plate of the patch and the size of the feeding loop. The measured maximum reading distance of the tag at 910 MHz was 5 m when it was mounted on a 400 mm${\times}$400 mm metallic surface. The proposed design is verified by simulation and measurements which show good agreement.

  • PDF

Design Equations for the H-plane Power Divider with a Circular Post in a Rectangular Waveguide

  • Han Sang-Sin;Lee Sun-Young;Ko Han-Woong;Park Dong-Hee;Ahn Bierng-Chearl
    • Journal of electromagnetic engineering and science
    • /
    • v.4 no.4
    • /
    • pp.150-155
    • /
    • 2004
  • Universal design equations are presented for the H-plane T-junction power divider with a circular conducting post in a rectangular waveguide. For a given operating frequency and power split ratio, the post offset from the T-junction center line, the distance between the post and the waveguide wall, and the post diameter can be adjusted to obtain a minimum reflection at the input waveguide. Optimum values of the post offset are given in terms of the normalized frequency and the power split ratio. Corresponding values of the post diameter and the distance of the post from the waveguide wall are given in terms of the normalized frequency and the post offset.

A Phase-to-Phase Distance Relaying Algorithm Using Direct 3 Phase Calculation (직접계산을 이용한 상간단락 거리계전 알고리즘)

  • Hyun, Seung-Ho;Lee, Sung-O
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.333_335
    • /
    • 2009
  • It is expected, in the near future, that the use of distributed generation systems should be increased considerably. In this case, distance relay algorithm should be developed in the manner that it can reduce the error due to the in-feed effect. This paper presents a method to consider the fault current rushed from the remote end of a line. In the steady-state, the relays in both ends exchange the voltages of upper nodes. If a fault is perceived, the relay calculates fault location taking the fault current from the remote end by using voltage data of the remote ends obtained just before the fault. Even though this method has inevitable error, it can show more precise fault allocation. The suggested method is applied to a typical transmission system with two power sources in both ends to verify its effectiveness.

  • PDF

Mass Distribution and Spray Characteristics to Liquid-Gas Line Selection of Unlike Triplet Impinging Injector (비동질 3중 충돌형 인젝터의 기체-액체 라인 선택에 따른 분무특성)

  • Lee, I.C.;Lee, C.J.;Koo, J.Y.
    • Journal of ILASS-Korea
    • /
    • v.11 no.4
    • /
    • pp.205-211
    • /
    • 2006
  • Impinging angle, impinging distance, length eve. diameter and injection pressure of a triplet injector were tested to evaluate the spray characteristics injected by liquid/gas combinations. Two different kinds of unlike triplet sprays were produced by changing the gas and liquid feed lines. One was the G-L-G(Gas-Liquid-Gas) type, and the other was L-G-L(Liquid-Gas-Liquid) type. Spray angles were wider with the G-L-G type than with L-G-L type. Mass distributions in spray were obtained with a, mechanical patternator. Mass distributions were not circular but elliptical distributions. When the range of mechanical patternator to injector decreased, mass distributions were more concentrated in the center region.

  • PDF

The Characteristics of Surface Roughness when Micro Blasting of Titanium Alloy with Spiral Movement (티타늄합금의 나선운동 미세입자 분사가공 시 표면거칠기 특성)

  • Kim, Sang-Hyun;Wang, Duck-Hyun;Lee, Se-Han
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.4
    • /
    • pp.125-130
    • /
    • 2012
  • When conducting a powder blasting to a spinning cylindrical workpiece in the codition of 0.76~1.5(mm) in nozzle size, 1~5(atm) in working pressure, and 40~100(mm) in stand off distance, the value of surface roughness becomes under $0.283{\mu}m$, which is not enough to expand a bonding area. In the case of horizontal transfer blasting with 0.76mm of nozzle size, 100mm of stand off distance, and 2~5atm of working pressure, $0.5{\sim}0.7{\mu}m$ of surface roughness has achieved regardless of feed rate.

Design of Multistage Orifices for PIC System in Nuclear Reactor (원자로 압력 및 체적제어계통의 다단 오리피스 설계)

  • Shin, J.C.
    • Journal of Energy Engineering
    • /
    • v.24 no.2
    • /
    • pp.17-21
    • /
    • 2015
  • Restriction orifices in the feed and bleed circuit of nuclear power plant are designed using computer program capable of handling multiple hole cascade orifice assembly. Single hole stages of orifice assembly are alternated with multihole stages where necessary. The distance between stages is such that it allows full pressure recovery. The minimum static pressure is higher than vapor pressure at the operating temperature so that cavitation does not occur. Piping sizes are reviewed and increased if necessary to improve rigidity.

The influence of spraying conditions to the coating layer properties of Fe-Cr-Ni-Mo-Si-B alloy using the HVOF (HVOF를 이용한 Fe-Cr-Ni-Mo-Si-B계 고성능 합금 용사층의 특성에 미치는 용사조건의 영향)

  • 권기봉;조대형;장영권;백영남
    • Journal of the Korean institute of surface engineering
    • /
    • v.35 no.1
    • /
    • pp.5-10
    • /
    • 2002
  • This study was performed to investigate the influence of spraying condition to the coating layer properties of Fe-Cr-Ni-Mo-Si-B alloy using the HVOF. The investigations, such as thickness measurement, surface roughness, hardness, friction coefficient, resistance of corrosion were carried out. Matrix is prepared by gritting and coating layer is made of Fe-Cr-Ni-Mo-Si-B alloy powder using HVOF. Alumina gritting layers are superior to steel gritting layers. The less spaying distance, the more coating layer properties confirmed. The optimum spraying condition, in this study, was proved as 13inch spraying distance with feed rate 350rpm (78g/min).

Effects of Gas Flow Variables on the Crystal Growth of Diamond in Hot Filament-Assisted CVD (고온 필라멘트 다이아몬드 CVD에서 기체유동변수가 결정성장에 미치는 영향)

  • 서문규;이지화
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.1
    • /
    • pp.88-96
    • /
    • 1994
  • Hot filament-assisted CVD was carried out to deposit diamond films on Si(100) substrate at 90$0^{\circ}C$ using a 1% CH4-H2 mixture gas. Deposition was made at various conditions of mass flow rate of the feed gas (30~1000 sccm), pressure (2.5~300 Torr), and filament-substrate distance (4~15 mm), and the deposited films were characterized by SEM, XRD, and Raman spectroscopy. As the flow rate increases, the growth rate also increased but the crystallinity of the film was degraded. A longer filament-substrate distance simply caused both the growth rate and the crystallinity to become poorer. On the other hand, the pressure variation resulted in a maximum growth rate of 2.6 ${\mu}{\textrm}{m}$/hr at 10 Torr and the best film quality around 50 Torr, exhibiting an optimum condition. The observed trends were interpreted in terms of the flow velocity-dependent pyrolysis reaction efficiency and mass transport through the boundary layer.

  • PDF

Modeling and Simulation Reactive Power Compensator using Multi-port Network Algorithm in Electrified Railway (다단자망 알고리즘을 이용한 급전시스템의 무효전력 보상 모델링 및 시뮬레이션)

  • Kim, Joorak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.883-887
    • /
    • 2016
  • The power supply system in Korean electrified railway has adopted AT feeding. If a fault occurs in some substation for any reason, the vicinity substation must feed electric power on the outage substation through catenary. So, the feeding distance grows twice of the normal state at extended feeding condition. If substation's feeding distance is longer than normal condition, the catenary impedance and train to supply electric power from the substation. Therefore, the severe voltage drop can occur and power supply shall be not allowed. This paper presents the model of compensator against voltage drop using multi-port network algorithm. Whole traction power supply system can be analyzed with this model. Computer simulation including this model is performed based on real train schedule and increased schedule in case studies.

Development and Verification of the Automated Cow-Feeding System Driven by AGV (무인이송로봇기반 자동 소사료 공급 시스템 개발 및 검증)

  • Ahn, Sung-Su;Lee, Yong-Chan;Yoo, Ji-Hun;Lee, Yun-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.232-241
    • /
    • 2017
  • This paper presents an automated cow-feeding system based on an AGV and screw conveyor for domestic livestock farms, which are becoming larger and more commercialized. The system includes a hopper module for loading pellet-type mixed feed at the top of the system, a transfer module mounted with a screw conveyor to transfer feed from the hopper module to the outlet module, an outlet module composed of belt conveyors, and an electromagnetic guided driving-type AGV. The weight of the loaded feed is measured by a load cell located under the transfer module. The system reads the feed discharge information stored in RFID tags installed in each cowshed cell, and a predetermined amount of feed is discharged while the AGV is moving. A cow-feed test system was constructed to determine the design parameters of the screw conveyor in the transfer module that determine the feeding capacity. These parameters include the screw's outer diameter, the screw shaft outer diameter, and screw pitch. The parameters were applied to the finalized cow-feed system construction. A DSP-based main controller and cow-feeding algorithm for different scenarios were also developed to control the system. Experimental results confirmed that the system could supply a total of 21 kg of feed uniformly at 420 g/s for a cowshed cell which has 7 cows. The driving distance was 5 m and the speed was 0.1 m/s. Thus, the proposed system could be applied to standardized domestic livestock farms.