• Title/Summary/Keyword: Feed Water

Search Result 1,722, Processing Time 0.028 seconds

Effect of Spirulina platensis and Probiotics as Feed Additives on Growth of Shrimp Fenneropenaeus chinensis

  • Kim Choong-Jae;Yoon Sook-Kyung;Kim Hong-Ik;Park Yong-Ha;Oh Hee-Mock
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.8
    • /
    • pp.1248-1254
    • /
    • 2006
  • The effect of Spirulina platens is and probiotics as feed additives on the growth of the shrimp Fenneropenaeus chinensis was investigated in comparison with a control. The shrimp were cultured in rearing tanks in a seawater pond for 35 days from September 1, 2004. As regards the water quality, the probiotic treatment (T2, commercial diet and 3% probiotics) produced a lower TDN (total dissolved nitrogen) and TDP (total dissolved phosphorus), making it effective in water quality improvement. Nonetheless, the phytoplankton flora succeeded from diatoms to cyanobacteria, regardless of the feed additives. Treatment T3, including 3% S. platensis, produced the highest mean body weight, which was 39% higher than that for all the other treatments (P<0.05). Accordingly, it was found that the use of Spirulina and probiotics as feed additives increased the shrimp body weight and improved the water quality, respectively.

Effect of Feed concentration (S0) and F/M ratio (S0/X0) on Anaerobic Digestion of Thickened Sewage Sludge (기질 농도 (S0)와 F/M 비 (S0/X0)가 농축 하수 슬러지 혐기성 소화에 미치는 영향)

  • Kim, Sang-Hyoun;Ju, Hyun Jun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.825-831
    • /
    • 2012
  • The retrofitting of a thickening unit process is widely considered in municipal wastewater treatment plants in Korea to enhance the anaerobic digestion efficiency. The authors examined the effect of feed concentration (2-34.1 g VS/L) and feed to microorganism (F/M) ratio (0.50-1.35 g VS/g VS) on anaerobic batch digestion of sewage sludge. Methane yield over 90 mL $CH_4/g$ $VS_{feed}$ was found at a feed concentration in the range of 12-26 g VS/L and a F/M ratio below 0.6 g VS/g VS. A high F/M ratio decreased methane yield and rate with oragnic acid accumulation. As sudden increase of sewage sludge concentration prior to anaerobic digestion would jeopardize the digester performance due to the rasied F/M ratio, gradual increase of the sludge feed concentration or an additional biomass retention in the digester is recommended.

Feed supply system for Fish farm in Ocean Sea (외해 가두리 양식장용 먹이공급시스템)

  • Oh, Jin-Seok
    • Journal of Navigation and Port Research
    • /
    • v.34 no.10
    • /
    • pp.793-797
    • /
    • 2010
  • The depleting fishes resource and water pollution in coast has a decisive effect on the fish farm and fisheries. For solving these problems the fish farms are moving to the offshore. The fish farms in offshore have to design the strong mechanism as compared with cost's fish farm, and operate by the remote feeding system and monitoring system for safety and management.. This paper describes a remote feeding system for fish farms in offshore. The amount of feed is depending on temperature and fish weight. The fish farm temperature is changed extremely in offshore than on land side. This paper described that the feed amount is calculated automatically according to temperature and fish weight, and the remote feed system. The performance of remote feed system is tested with model.

Characteristics of Reverse Flux by using Direct Omosis in RO Membrane Process (역삼투막 공정에서 Direct Osmosis의 역방향 Flux 기초특성)

  • Kang, Il-Mo;Dock-Ko, Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.3
    • /
    • pp.399-405
    • /
    • 2011
  • In a desalination technology using RO membranes, chemical cleaning makes damage for membrane surface and membrane life be shortened. In this research cleaning technology using direct osmosis (DO) was introduced to apply it under the condition of high pH and high concentration of feed. When the high concentration of feed is injected to the concentrate side after release of operating pressure, then backward flow occurred from treated water toward concentrated for osmotic pressure. This flow reduces fouling on the membrane surface. Namely, flux of DO was monitored under pH 3, 5, 10 and 12 conditions at feed concentrations of NaCl 40,000 mg/L, 120,000 mg/L and 160,000 mg/L. As a result, DO flux in pH 12 increased about 21% than pH 3. DO cleaning was performed under the concentrate NaCl 160,000 mg/L of pH 12 during 20 minutes. Three kinds of synthetic feed water were used as concentrates. They consisted of organic, inorganic and seawater; chemicals of SiO2 (200 mg/L), humic acid (50 mg/L) sodium alginate (50 mg/L) and seawater. As a result, fluxes were recovered to 17% in organic fouling, 15% in inorganic fouling and 14% of seawater fouling after cleaning using DO under the condition of concentrate NaCl 160,000 mg/L of pH 12.

Development of superconducting high gradient magnetic separation system for scale removal from feed-water in thermal power plant

  • Shibatani, Saori;Nakanishi, Motohiro;Mizuno, Nobumi;Mishima, Fumihito;Akiyama, Yoko;Okada, Hidehiko;Hirota, Noriyuki;Matsuura, Hideki;Maeda, Tatsumi;Shigemoto, Naoya;Nishijima, Shigehiro
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.1
    • /
    • pp.19-22
    • /
    • 2016
  • A Superconducting High Gradient Magnetic Separation (HGMS) system is proposed for treatment of feed-water in thermal power plant [1]. This is a method to remove the iron scale from feed-water utilizing magnetic force. One of the issues for practical use of HGMS system is to extend continuous operation period. In this study, we designed the magnetic filters by particle trajectory simulation and HGMS experiments in order to solve this problem. As a result, the quantity of magnetite captured by each filter was equalized and filter blockage was prevented. A design method of the magnetic filter was proposed which is suitable for the long-term continuous scale removal in the feed-water system of the thermal power plant.

Application of nanofiltration membrane for the River Nile water treatment in Egypt: Case study

  • Jamil, Tarek S.;Shaban, Ahmad M.;Mansor, Eman S.;Karim, Ahmed A.;El-Aty, Azza M. Abd
    • Membrane and Water Treatment
    • /
    • v.9 no.4
    • /
    • pp.233-243
    • /
    • 2018
  • In this manuscript, $35m^3/d$ NF unit was designed and applied for surface water treatment of the River Nile water. Intake of Embaba drinking water treatment plant was selected to install that unit at since; it has the lowest water quality index value through the examined 6 sites in greater Cairo area. The optimized operating conditions were feed and permeate flow, 40 and $7m^3/d$, feed pressure 2.68 bar and flux rate $37.7l/m^2h$. The permeate water was drinkable according to Egyptian Ministerial decree 458/2007 for the tested parameters (physic-chemical, heavy metals, organic, algal, bacteriological and parasitological). Single and double sand filters were used as pretreatment for NF membranes but continuous clogging for sand filters moved us to use UF membrane as pretreatment for NF membrane.

Mixed matrix membranes of poly(vinyl alcohol) loaded with phosphomolybdic heteropolyacid for the pervaporation separation of water-isopropanol mixtures (Water-IsopropanoI 혼합물의 투과증발 분리를 위한 poly(vinyl alcohol)-phosphomoIybdic heteropolyacid 혼합막)

  • Teli, Shivanand;Choi, Hyoung-Woo;Moon, Jung-Me;Park, Ji-Hye;Hong, Sung-Pyo;Tak, Tae-Moon
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2008.05a
    • /
    • pp.51-57
    • /
    • 2008
  • Mixed matrix membranes of poly(vinyl alcohol) (PVA), loaded with phosphomolybdic heteropolyacid (HPA) and crosslinked with glutaraldehyde have been prepared by the solution casting technique. Pervaporation (PV) experiments have been performed at $30^{\circ}C$ to separate water-isopropanol feed mixtures containing 10 to 40 wt.% of water. The membranes were characterized by DSC and DMTA to understand their thermal behavior and mechanical strength properties. At high content (i.e. 7 wt.% with respect to weight of PVA) of HPA, the mixed matrix membranes could extract water efficiently on the permeate side with a selectivity of 90,000 and a flux of 0.032 $kg/m^2h$ for 10 wt.% of water containing feed mixture (the lowest feed composition of water studied). Flux of the mixed matrix membranes decreased with increasing concentrations of HPA.

  • PDF

Cost Reduction for Small-Scale Desalination Plants (소규모 해수담수화 시설의 생산비용 절감 방안)

  • Park, Nam-Sik;Park, Jun-Yeong;Mun, Yu-Ri;Kim, Ja-Kyum
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.10
    • /
    • pp.809-817
    • /
    • 2011
  • We analyzed various cost components for approximately 40 small-scale island desalination plants operated by K-water. A significant factor affecting desalination cost was found, and we proposed a way to reduce desalination costs. All plants considered were reverse osmosis (RO) facilities. TDS concentrations of feed water varied from less than 1,000 mg/L (practically considered freshwater) to over 30,000 mg/L (nearly seawater). Analysis of desalination costs from 2005 to 2009 indicated that maintenance, labor, and energy were the three biggest components that accounted for 50.6%, 36.9% and 7.8%, respectively. It was well known that TDS of feed water directly affected energy needed for RO process. In this study we found that maintenance cost was also directly related to feed water TDS. This finding indicated that lowering feed water TDS might result in significant desalination cost reduction.

The effect of intermittent feeding and cold water on performance and carcass traits of broilers reared under daily heat stress

  • Erensoy, Kadir;Noubandiguim, Moise;Sarica, Musa;Aslan, Resul
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.33 no.12
    • /
    • pp.2031-2038
    • /
    • 2020
  • Objective: This study aimed to determine the effect of intermittent feeding and cold water on performance and carcass traits in broiler chickens between 4 to 6 wk of age exposed to daily high temperature. Methods: Broilers were assigned to four treatment groups according to a 2×2 factorial design between 22 to 42 d of age (80 broilers per treatment, 4 replications). Broilers were divided into two main groups as feeding type (ad-libitum [AL] and intermittent [IF] for 6 h daily) and sub-groups as water temperature (normal [NW], 24.9℃ and cold [CW], 16.4℃). Heat treatment was applied between 11.00 to 17.00 h daily between 22 to 42 d of age. Results: Live weight at 6th wk was not affected by feeding type and water temperature, but the live weight was significantly higher in IF chickens at the 5th wk (p<0.05). Average weekly gain of IF broiler chickens were higher compared to AL group at 4, 5, and 6 wk of age (p< 0.05). Although feeding type did not affect feed intake in 4 and 5th wk, feed intake was higher in IF chickens at 6th wk (p<0.01). In addition, feeding type and water temperature did not affect feed conversion ratio and interactions were not significant (p>0.05). Water temperature had no significant effect on heart, liver, gizzard, and abdominal fat percentages (p>0.05). Conclusion: It is concluded that IF increased the average weekly gain in chickens reared under daily heat stress for 6 h between 22 to 42 d of age. IF in hot environmental conditions slightly increased performance without adversely affecting health, welfare, and physiological traits, whereas CW implementation had no significant effect on performance. It can also be said that IF suppresses a sudden increase in body temperature depending on age and live weight.

Fish Diseases and Their Control in High Density Culture of Eel (고밀도 뱀장어 양식수조의 질병대책)

  • CHUN Seh Kyu
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.16 no.2
    • /
    • pp.103-110
    • /
    • 1983
  • The main purpose of the present study is to evaluate a revolving plate type biofilter system for mass culture of eel(Anguilla japonica) based on the experimental rearing for 120 days (Oct. 1982-Feb. 1983). Water quality changes, growth efficiency of fish and fish disease treatment were critically evaluated. A revolving plate type biofilter system was designed(Fig. 1). The system consisted of a glass tank (150 l), a revolving plate biofilter and a settling tank(150 l). The biofilter consisted of 60 submerged quadriangular plates ($28{\times}37$ cm) and 30 revolving plates (32 cm diameter) for a total of 19.0 $m^2$ of surface area. The revolving plates were made to rotate 10 time per minute, The total water volume of the rearing system were 300 l, and everyday 1/3 of the total water volume were changed with freshly prepared water. In the rearing system a total of 2 kg of eel (1,500 individuals, mean weight:1.3 g) were reared fed on the pellet feed and the dough feed. The growth efficiency were much better for the pellet feed (FC: 1.79) compared to the dough feed (FC: 3.56). During the experimental rearing water quality control was satisfactory. Total ammonia concentrations were 0.38-0.59 ppm and nitrite concentration were 0.83-1.19 ppm. On the other hand alkalinity decreased from 176ppm just after the water change to 17ppm just before the water change. The low alkaline condition was compensated by the regular change of water. Epidemics of parasitic gill-flocks (Pseudodactvlogylus sp.) was observed, and they were easily eliminated by the treatment of DDVP (1.0 ppm). Trichodina sp. and Costia sp. were observed, and they were also controlled by the treatment of potassium permanganate (4.0 ppm).

  • PDF