• Title/Summary/Keyword: Feed Pressure

Search Result 530, Processing Time 0.488 seconds

Effect of Flow Rates of Feed and Sweep Gas on Oxygen Permeation Properties of Ba0.5Sr0.5Co0.8Fe0.2O3-δ Membrane (공급가스 및 스윕가스 유량에 따른 Ba0.5Sr0.5Co0.8Fe0.2O3-δ 분리막의 산소투과특성)

  • Park, Se Hyung;Sonn, Jong Suk;Lee, Hong Joo;Park, Jung Hoon
    • Korean Chemical Engineering Research
    • /
    • v.53 no.4
    • /
    • pp.407-411
    • /
    • 2015
  • Dense ceramic membranes have been prepared using the commercial perovsikite $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$, powders synthesized by the solid state reaction method. The as-synthesized powders were compressed into disks with 1.0 mm of thickness and the disk was sintered at $1,100^{\circ}C$ for 2 hr. The oxygen permeation flux of $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ membrane increased with the increasing temperature and oxygen partial pressure. The activation energy for oxygen permeation was increased with the increasing oxygen partial pressure. Oxygen permeation flux at $950^{\circ}C$ were measured at various flow rates of feed and sweep gas. It has been demonstrated that oxygen permeability increased at elevated flow rates of both gases, but the sweep gas is more influential.

Preparation and Oxygen Permeability of Nb-doped BCFN Ceramic Membrane (Nb-doped BCFN 세라믹 막의 제조 및 산소투과 특성)

  • Kim, Jong-Pyo;Son, Sou-Hwan;Park, Jung-Hoon;Lee, Yong-Taek
    • Membrane Journal
    • /
    • v.21 no.1
    • /
    • pp.55-61
    • /
    • 2011
  • $BaCo_{0.7}Fe_{0.22}Nb_{0.08}O_{3-{\delta}}$ oxide was synthesized by solid state reaction method. Dense ceramic membrane was prepared using as-prepared powder by pressing and sintering at $1,200^{\circ}C$. XRD result of membrane showed single perovskite structure. Leakage and oxygen permeation test were conducted on the membrane sealed by glass ring as a sealing material. The oxygen permeation flux increased with increasing temperature and pressure difference and maximum oxygen permeation flux was $2.3mL/min{\cdot}cm^2$ at $950^{\circ}C$ with $Po_2$ = 0.63 atm of oxygen partial pressure. The oxygen permeation in the condition of air with $CO_2$ (300 ppm) as feed stream decreased as much as only maximum 2.9% in comparison with air feed stream. It indicated $BaCo_{0.7}Fe_{0.22}Nb_{0.08}O_{3-{\delta}}$ membrane is more stable than another membrane for carbon dioxide.

Analysis of the Vent Path Through the Pressurizer Manway Under the Loss of Residual Heat Removal(RHR) System During Mid-Loop Operation in PWR (가압경수로 부분충수 운전중 잔열제거 (RHR)계통 상실시 가압기 통로를 통한 배출유로 특성 분석)

  • Ha, G.S.;Kim, W.S.;Chang, W.P.;Yoo, K.J.
    • Nuclear Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.859-869
    • /
    • 1995
  • The present study is to understand the physical phenomena anticipated during the accident with RHR loss under mid-loop operation in a PWR and, at the same time, to examine the prediction capability of RELAP5/MOD3.1 on such an accident, by simulating an integral test relevant to this accident for reliable analysis in an actual PWR. The selected experiment, i.g. BETHSY Test 6.9a, represents the configuration with the pressurizer manway open and steam generators unavailable during the accident. Accordingly, the results of this ok are sure to contribute to understanding both the key events as well as the sensitive parameters, anticipated in the accident, for validity of the actual analysis. In the simulation result overall behavior as well as major phenomena observed in the experiment have been predicted reasonably by RELAP5/MOD3.1, however, the problem associated with enormous computing time .due to small time step size has been encountered. Besides, the code prediction of higher swollen level in the pressure vessel has given rise to overestimation of both pressurizer level and RCS pressure. Subsequently, overprediction of the break flow through the manway has led to earlier core uncovery than that in the experiment by about 400 seconds. As a whole, it is demonstrated from both the experiment and the analysis that gravity feed has not been sufficient to recover the core level and thus additional forced feed has been necessary in this configuration.

  • PDF

Effect of Process Variables on System Parameters in Extrusion Cooking of Corn Grit by Twin Screw Extruder (옥분 압출가공시 이축압출성형기의 운전조건에 따른 System Parameters의 변화)

  • Kim, Ji-Yong;Kim, Chong-Tai;Kim, Chul-Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.81-87
    • /
    • 1991
  • To examine the effect of the individual operational variables on extrusion process, test trials of the fractional factorial design of the three process variables at three levels, including feed rate, screw speed and die openings, were carried out by using a laboratory scale twin-screw extruder with three different screw configuration for corn grit with the water addition fixed at 15% of the powder feed rate. As the increase of feed rate, while extrusion temperature(ET), specific mechanical energy input (SME), and residence time(RT) were showed the tendency to decrease, extrusion pressure(EP) was increased and as the increase of screw speed, ET, SME and EP were showed the tendency to increase, but RT was decreased. However, as increase the number of die hole, all system parameters were showed the tendency to decrease. The influence of the change in each process parameters was increased as the increase of the number of reverse element in screw configuration. In case of using the screw configuration with increasing number of reverse element at the condition of same process parameters, ET, SME and RT was increased, but EP was decreased. The functional relationships of the system parameters to the process parameters can be quantified by using multiple regression equations(mostly R-sq>0.90) and maped on suface response diagrams to expedite evaluation.

  • PDF

Pervaporation of Butanol from their Aqueous Solution using a PDMS-Zeolite Composite Membrane (PDMS-Zeolite 복합막을 이용한 부탄올 투과증발)

  • Kong, Chang-In;Cho, Moon-Hee;Lee, Yong-Taek
    • Korean Chemical Engineering Research
    • /
    • v.49 no.6
    • /
    • pp.816-822
    • /
    • 2011
  • Pervaporation is known to be a low energy consumption process since it needs only an electric power to maintain the permeate side in vacuum. Also, the pervaporation is an environmentally clean technology because it does not use the third material such as an entrainer for either an azeotropic distillation or an extractive distillation. In this study, Silicalite-1 particles are hydrothermally synthesized and polydimethylsiloxane(PDMS)-zeolite composite membranes are prepared with a mixture of synthesized Silicalite-1 particles and PDMS-polymer. They are used to separate n-butanol from its aqueous solution. Pervaporation characteristics such as a permeation flux and a separation factor are investigated as a function of the feed concentration and the weight % of Silicalite-1 particles in the membrane. A 1,000 $cm^3$ aqueous solution containing butanol of low mole fraction such as order of 0.001 was used as a feed to the membrane cell while the pressure of the permeation side was kept about 0.2~0.3 torr. When the butanol concentration in the feed solution was 0.015 mole fraction, the flux of n-butanol significantly increased from 14.5 g/ $m^2$/hr to 186.3 g/$m^2$/hr as the Silicalite-1 content increased from 0 wt% to 10 wt%, indicating that the Silicalite-1 molecular sieve improved the membrane permselectivity from 4.8 to 11.8 due to its unique crystalline microporous structure and its strong hydrophobicity. Consequently, the concentration of n-butanol in the permeate substantially increased from 0.07 to 0.15 mole fraction. This composite membrane could be potentially appliable for separation of n-butanol from insitu fermentation broth where n-butanol is produced at a fairly low concentration of 0.015 mole fraction.

Carbon Dioxide Separation by Hollow Fiber Membrane of Polyethersulfone : Comparison of Experimental Results with Numerical Analysis Data (Polyethersulfone 중공사 분리막에 의한 이산화탄소 분리 : 실험과 수치해석 비교)

  • Lee, Yong-Taek;Song, In-Ho;Ahn, Hyo-Seong;Jeon, Hyung-Soo;Joung, Houn-Kyu;Kim, Jeong-Hoon;Lee, Soo-Bok
    • Membrane Journal
    • /
    • v.17 no.2
    • /
    • pp.134-139
    • /
    • 2007
  • Experimental and numerical analysis were performed for separation of carbon dioxide from carbon dioxide and nitrogen gas mixture using a polyethersulfone hollow fiber membrane. The experimental results were compared with those obtained at the same operating condition by the numerical analysis. It was observed that there was a big difference between the experimental results and those by a numerical analysis where the permeance of carbon dioxide and its ideal selectivity over nitrogen were obtained from the pure gas permeation. Therefore, the permeance of carbon dioxide and its selectivity were obtained from the separation experimental results using the numerical analysis as a function of the mole fraction of carbon dioxide, the feed pressure and the permeate pressure in the gas mixture. The results of the numerical analysis using the selectivity obtained from the gas mixture were in good agreement with those of the experimental.

A Study of the Life Test of Hydraulic Pump Driving Gear Box for the Large Excavator (초대형 굴삭기용 유압펌프 구동 기어박스의 수명시험에 관한 연구)

  • Lee, Yong Bum
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.3
    • /
    • pp.211-216
    • /
    • 2015
  • Large hydraulic excavator weighted 90 tons used the several pumps installed in parallel to use the hydraulic pump driving gearbox to improve fuel consumption by improving the energy efficiency of the hydraulic system. Gearbox connected to hydraulic pump supply the mechanical output to the high pressure and low pressure pump to be supplied by torque and rotation, which are the mechanical power, through a input shaft connected to large size engine of the excavator. So, gearbox connected to hydraulic pump is same as main artery in the human body and is required long life because it operates the hydraulic pump continuously during operating the engine. This study had used oil contamination analysis method to check the wear characteristics of the gearbox and frequency response characteristic analysis method to check the failure of the teeth failures of gearbox, while the test equipment adopted by the electrical feedback method to reduce the energy consumption was operating for the life assessment, in which the required power was 600 kW input power.

Evaluation of Seawater Reverse Osmosis Desalination System with UF and Disk Filter as Pre-Treatment (UF와 디스크필터를 전처리시설로 이용한 역삼투압해수담수설비의 평가)

  • Yang, Keun-Mo;Lim, Dong-Hoon;Kim, Joon Ha;Jung, Hyung-Ho
    • Transactions of the KSME C: Technology and Education
    • /
    • v.1 no.1
    • /
    • pp.59-68
    • /
    • 2013
  • In the present study, sea water reverse osmosis desalination system was composed with an ultra-filtration membrane as a pre-treatment. Sea water was induced into the pre-treatment composed with an auto-screen filter and an ultra-filtration membrane. It was proved that the permeate of the pre-treatment was adequate for reverse osmosis desalination system by measuring the $SDI_{15}$ and the turbidity. Feed salinities was changed by mixing the brine and the permeate. Inlet salinities effected the performances of sea water reverse osmosis desalination system in a large amount such as the salt rejection, the recovery ratio, the pressure, the product salinity. Energy consumptions per the ton of the product were almost linearly increased with the inlet salinities.

Wafer-level Vacuum Packaging of a MEMS Resonator using the Three-layer Bonding Technique (3중 접합 공정에 의한 MEMS 공진기의 웨이퍼레벨 진공 패키징)

  • Yang, Chung Mo;Kim, Hee Yeoun;Park, Jong Cheol;Na, Ye Eun;Kim, Tae Hyun;Noh, Kil Son;Sim, Gap Seop;Kim, Ki Hoon
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.354-359
    • /
    • 2020
  • The high vacuum hermetic sealing technique ensures excellent performance of MEMS resonators. For the high vacuum hermetic sealing, the customization of anodic bonding equipment was conducted for the glass/Si/glass triple-stack anodic bonding process. Figure 1 presents the schematic of the MEMS resonator with triple-stack high-vacuum anodic bonding. The anodic bonding process for vacuum sealing was performed with the chamber pressure lower than 5 × 10-6 mbar, the piston pressure of 5 kN, and the applied voltage was 1 kV. The process temperature during anodic bonding was 400 ℃. To maintain the vacuum condition of the glass cavity, a getter material, such as a titanium thin film, was deposited. The getter materials was active at the 400 ℃ during the anodic bonding process. To read out the electrical signals from the Si resonator, a vertical feed-through was applied by using through glass via (TGV) which is formed by sandblasting technique of cap glass wafer. The aluminum electrodes was conformally deposited on the via-hole structure of cap glass. The TGV process provides reliable electrical interconnection between Si resonator and aluminum electrodes on the cap glass without leakage or electrical disconnection through the TGV. The fabricated MEMS resonator with proposed vacuum packaging using three-layer anodic bonding process has resonance frequency and quality factor of about 16 kHz and more than 40,000, respectively.

Acute Toxicity and General Pharmacological Action of QGC EXT

  • Lee, Jong-Mi;Im, Wi-Joon;Nam, Yoon-Jin;Oh, Kyung-Hoon;Lim, Jae-Chun;Whang, Wan-Kyunn;Sohn, Uy-Dong
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.16 no.1
    • /
    • pp.49-57
    • /
    • 2012
  • It has been shown that QGC isolated and purified from Rumecis folium found protective effects of gastritis and esophagitis which EXT is an ethanol extract of it. We examined acute toxicity and the general pharmacological action of QGC EXT to search for any side effects of it in rats, mice, guinea pigs, and cats. In a single dose toxicity study, QGC EXT didn't show toxicological effects in rats and mice, and the $LD_{50}$ was over 5 g/kg in both animals, and there were also no changes in weight, feed and water intake during these toxicological experimental periods. We examined the general pharmacological action on central controlled behavior responses, and peripheral organs including blood pressure, heart rate, respiration and gastrointestinal system, We found that there were no significant changes in body temperature, locomotors activity, stereotyped behaviors, sleeping time, and convulsion. In other studies, writhing reaction, normal body temperature, there did not appear to be any changes. The large intestine movement and electrical field stimulation-induced contraction was not changes by its EXT. In addition, the influences on blood pressure, heart rates, and respiration by QGC EXT were not found. These results indicate that QGC EXT may be very safe as a new drug, since its $LD_{50}$ was very high over 5 g/kg and any side effects were not found.