• Title/Summary/Keyword: Fecal Sludge

Search Result 9, Processing Time 0.026 seconds

Change of Microbial Community on Ozonation of Sewage Sludge to Reduce Excess Sludge Production (폐슬러지 감량화 및 재활용을 위한 오존 처리시 하수슬러지내의 미생물 군집구조의 변화)

  • Hong, Jun-Seok;Lim, Byung-Ran;Ahn, Kyu-Hong;Maeng, Sung-Kyu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.1
    • /
    • pp.59-65
    • /
    • 2004
  • The change of the microbial community structure in excess sludge of different sewage treatment plants by ozone treatment was investigated by quinone profiles. The resulting ozone dosage ranged from 0.1 to $0.4gO_3/gTS$. In terms of overall sludge reduction, more than 50% reduction of the total sludge mass could be achieved by ozone treatment at $0.4gO_3/gTS$. Quinone concentration and type in sludge of different treatment plants were remarkably decreases with increasing ozone dose. Ubiquinones(UQs)-8, -10 and MK-8 were still remained in the ozonized sludge at $0.4gO_3/gTS$. The results of this study showed that the remaining microorganisms belong to UQs-8, -10 and MK-8 were difficult to destruct cell membrane or wall by ozonation. Fecal Streptococci and Salmonella were not detected at ozone dose of $0.2gO_3/gTS$, but Fecal Coliform was not detected at ozone dose of $0.4gO_3/gTS$.

Integrated Eco-Engineering Design for Sustainable Management of Fecal Sludge and Domestic Wastewater

  • Koottatep, Thammarat;Polprasert, Chongrak;Laugesen, Carsten H.
    • Journal of Wetlands Research
    • /
    • v.9 no.1
    • /
    • pp.69-78
    • /
    • 2007
  • Constructed wetlands and other aquatic systems have been successfully used for waste and wastewater treatment in either temperate or tropical regions. To treat waste or wastewater in a sustainable manner, the integrated eco-engineering designs are explained in this paper with 2 case studies: (i) a combination of vertical-flow constructed wetland (CW) with plant irrigation systemfor fecal sludge management and (ii) integrated CW units with landscaping at full-scale application for domestic wastewater treatment. The pilot-scale study of fecal sludge management employed 3 vertical-flow CW units, each with a dimension of $5{\times}5{\times}0.65m$ (width ${\times}$ length ${\times}$ media depth) and planted with cattails (Typha augustifolia). At the solid loading rate of 250 kg total solids (TS)/$m^2.yr$ and a 6-day percolate impoundment, the CW system could achieve chemical oxygen demand (COD), TS and total Kjeldahl nitrogen (TKN) removal efficiencies in the range of 80 - 96%. The accumulated sludge layers of about 80 - 90 cm was found at the CW bed surface after operating the CW units for 7 years, but no clogging problem has been observed. The CW percolate was applied to 16 irrigation Sunflower plant (Helianthus annuus) plots, each with a dimension of $4.5{\times}4.5m$ ($width{\times}length$). In the study, the CW percolate were fed to the treatment plots at the application rate of 7.5 mm/day but the percolate was mixed with tap water at different ratio of 20%, 80% and 100%. Based on a 1-year data of 3-crop plantation were experimented, the contents of Zn, Mn and Cu in soil of the experimental plots were found to increase with increasing in CW percolate ratios. The highest plant biomass yield and oil content of 1,000 kg/ha and 35%, respectively, were obtained from the plots fed with 20% or 50% of the CW percolate, whereas no accumulation of heavy metals in the plant tissues (i.e. leaves, stems and flowers) of the sunflower is found. In addition to the pilot-scale and field experiments, a case study of the integrated CW systems for wastewater treatment at Phi Phi Island (a Tsunami-hit area), Krabi province, Thailand is illustrated. The $5,200-m^2$ CW systems on Phi Phi Island are not only for treatment of $400m^3/day$ wastewater from hotels, households or other domestic activities, but also incorporating public consultation in the design processes, resulting in introducing the aesthetic landscaping as well as reusing of the treated effluent for irrigating green areas on the Island.

  • PDF

Bacterial Removal Efficiencies by Unit Processes in a Sewage Treatment Plant using Activated Sludge Process (활성슬러지공정 하수종말처리장의 단위공정별 세균 제거효율)

  • Lee, Dong-Geun;Jung, Mira;Sung, Gi Moon;Park, Seong Joo
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.5
    • /
    • pp.871-879
    • /
    • 2010
  • To figure out the removal efficiency of indicator and pathogenic bacteria by unit processes of a sewage treatment plant using activated sludge process, analyses were done for incoming sewage, influent and effluent of primary clarifier, aeration tank, secondary clarifier and final discharge conduit of the plant. A matrix of bacterial items (average of bacterial reduction [log/ml], p value of paired t-test, number of decreased cases of twenty analyses, removal percentage only for decreased cases) between incoming sewage and final effluent of the plant were heterotrophic plate counts (1.54, 0.000, 20, 95.01), total coliforms (1.38, 0.000, 19, 83.94), fecal coliforms (0.90, 0.000, 20, 94.84), fecal streptococci (0.90, 0.000, 20, 98.08), presumptive Salmonella (0.23, 0.561, 7, 99.09), and presumptive Shigella (1.02, 0.002, 15, 92.98). Total coliforms, fecal coliforms, heterotrophic plate counts, and fecal streptococci showed highest decrease through secondary clarifier about 1-log (p<0.001) between 88% and 96%, and primary clarifier represented the significant (p<0.05) decrease. However, final effluent through discharge conduit showed higher total coliforms and fecal streptococci than effluent of secondary clarifier (p<0.05). In addition, final effluent once violated the water quality standard while effluent of secondary clarifier satisfied the standard. Hence some control measures including elimination of deposits in discharge conduit or disinfection of final effluent are necessary.

The Effect of Enzyme/Microbial Additive on Anaerobic Digestion of Primary Sludge

  • Kim, Hyung-Jin;Song, Chang-Soo;Kim, Dong-Wook;Pagilla, Kishna-R.
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.10 no.S_1
    • /
    • pp.35-40
    • /
    • 2001
  • Effect of the addition of an enzyme/microbial additive(EMA) to enhance anaerobic digestion of the primary sludge was investigated. Two laboratory scale anaerobic digester were operated with primary sludge taken from a municipal wastewater treatment plant. The digester receiving EMA with the sludge feed performed better than the control digester, when both were operated at 10-days and 15-days Solid Retention Time(SRT). Addition of EMA to the experimental digester provided 7%(10-days SRT) and 16%(15-days SRT) higher gas production compared to the control digester when both were fed with the same amount of volatile solids. The reduction in volatile solids was 24% better in the experimental digester compared to the control ar 10-days SRT, and the improvement 10% at 15-day SRT. Improvement in COD reduction, and fecal coliform density reduction were also seen in the experimental digester due to EMA addition compared to the control both ar 10-days SRT and 15-day SRT operation. Preliminary cost benefit analysis for a wastewater treatment plant showed that approximately $115/day in gas production improvements can be realized upon addition of EMA to primary sludge anaerobic digesters operating at 10-day SRT. The value of increased gas production was $172/day if the same digesters are operated with EMA addition at 15-day SRT.

  • PDF

Enumeration and Comparison of Fecal Indicator Bacteria in a Sewage Treatment Plant Using Activated Sludge Process (활성슬러지공정 하수종말처리장의 분원성 지표세균의 농도 및 비교)

  • Lee, Dong-Geun;Sung, Gi-Moon;Jung, Mi-Ra;Park, Seong-Joo
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.2
    • /
    • pp.141-147
    • /
    • 2010
  • Indicator bacteria of fecal pollution were enumerated and compared by various detection methods for influent and final effluent of a sewage treatment plant. Total coliforms were enumerated by four methods including most probable numbers, chromogenic enzyme substrate test, membrane filtration, and plate counts and were about $10^4$ for influent and $10^2{\sim}10^3\;CFU/ml$ for final effluent. Fecal coliforms ranged between $10^3$ and $10^4$ for influent and $10^2\;CFU/ml$ for effluent by chromogenic enzyme substrate test and membrane filtration. Fecal streptococci counts were 1-log less than fecal coliforms counts, $10^2{\sim}10^3$ for influent and $10^1\;CFU/ml$ for effluent. Total coliforms numbers by plate count both in influent and in effluent showed 1-log higher than by the other three methods. Statistical analysis revealed that numbers of total coliforms by plate count in final effluent had the highest average of correlation (r=0.778, p<0.01) compared with those by the other three methods. In addition, total coliforms numbers by plate count showed most significant correlation (r=0.835, p<0.01) with those by chromogenic test which is well-known as its highest recovery efficiency. These results suggest that the plate count would be the optimum detection method for total coliforms in wastewater treatment plants which are the only microbiological standard of final effluent from wastewater treatment plants in the Republic of Korea, considering economic aspects and difficulties in laboratories.

Survey of fecal coliform contamination in sands of educational facilities and parks in Seoul (서울지역 교육시설 및 공원 내 토양 중 분원성대장균군 오염실태)

  • Kim, Hye-Ra;Kim, Neung-Hee;Park, Hyong-Suk;Kim, Doo-Hwan;Lee, Ju-Hyung
    • Korean Journal of Veterinary Service
    • /
    • v.37 no.4
    • /
    • pp.307-312
    • /
    • 2014
  • Fecal coliform bacteria are indicators of fecal contamination and of the potential presence of pathogens associated with animal excreta, wastewater, sludge. This study examined the distribution of fecal coliform in sand of the playground at educational facilities and parks in Seoul. Fecal coliform were detected from 61 (22.1%) places out of 276 playgrounds. Escherichia (E) coli (75.4%) was found most frequently, followed by Cronobacter (Cro) sakazakii (8.7%), Klebsiella (K) pneumoniae (7.2%) and Actinobacter baumannii (4.3%). We also tested the bacteria for their susceptibility to 16 antibiotics using disk diffusion method. All the isolates were highly susceptible to cefepime, gentamicin, tetracycline, ciprofloxacin, enrofloxacin, nalidixic acid and sulfamethoxazole/ trimethoprim, but resistant to apramycin and cephalothin. E. coli and Cro. sakazakii were highly resistant to apramycin (100% and 83.3%), followed by cephalothin (51.9% and 50%) and ampicillin (19.2% and 16.7%). K. pneumoniae was highly resistant to ampicillin and apramycin (100%, respectively) but the remaining antibiotics were susceptible.

Assessment of Aerobic Stabilized Waste Sludge as Liquid Fertilizer and Its Safety (슬러지 액비의 비효효과 및 안전성 평가)

  • Lee, Young-Ok;Hwang, Jin-Gyu;Hwang, Eung-Ju
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.3
    • /
    • pp.314-322
    • /
    • 2008
  • This study was carried out to assess aerobic stabilized waste sludge as liquid fertilizer for the growth of cucumber, cabbage and chrysanthemum. Sludge was pretreated with NaOH(40 meq/L) at 40$^{\circ}C$ for 330 min. The number of fecal coliforms in batch test sludge fertilizer was more efficiently reduced than those in continuous one, maybe due to longer SRT. All produced fertilizer belonged to class B according to US EPA requirement at least. Among 6 heavy metals regulated in Korea, As, Cd and Hg were not detectable in plant amended with fertilizer whereas the concentration of Cr, Cu and Pb in plant was less than 10 mg/kg dw. However, Zn and Ni, which were restricted in other country, but not in Korea, were detected in most amount of 118 mg/kg and 15.7 mg/kg, respectively. Furthermore, based on dry weight of plant, digested sludge(5.4 mg, dw) functioned as better fertilizer rather than activated sludge (4.3 mg, dw), much more fertile when those sludge was pretreated(1.24 mg, dw) compared to untreated one(1.12 mg, dw). But its fertility was 60$\sim$80% of commercial fertilizer and accumulation of Zn, Ti and Cr in plant was founded. Therefore, it could be concluded that sludge-fertilizer can be used for flower unlimitedly, but for edible plant limitedly as additive fertilizer.

Vermicomposting Condition and Safety/Fertility of Earthworm Casts (지렁이를 이용한 퇴비화 조건과 분변토의 비료성·안전성에 관한 연구)

  • Song, Jun-Sang;Lee, Kil-Chul;Chun, Sung-Hwan;Choi, Hun-Keun;Cho, Kyung-Hee;Kim, Sun-il
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.1 no.1
    • /
    • pp.85-102
    • /
    • 1993
  • This study was conducted to achieve develop organic sludge recycling technology as sludge make a prey of earthworm. Therefore sludge treatment and recycling technology is an important field by which this research project to solve landfill site and reduction treatment expense using vermicomposting treatment process on the waste sludge from the biological wastewater treatment plant. In experimental results on the optimum conditions of vermicomposting of nightsoil treatment sludge, survival rates were observed 98.3% in temperature of $10-15^{\circ}C$, 75% in pH 5.8-7.5 and 100% in density of $1/79.8cm^3$, respectively. Liveweight changes of earthworm were increased 266% in temperature of $10-15^{\circ}C$, 227% in pH 5.8-7.5 and 325 % in density $1\;cap./79.8cm^3$, respectively. Casting production rate were generated 0.06 g/cap./day in temperature $20-25^{\circ}C$, 0.065 g/cap./day in pH 5.8-7.5 and 0.1 g/cap./day in density $1\;cap./79.8cm^3$, respectively. Cocoon production numbers were observed 3.8 ea. /cap.in $10-15^{\circ}C$, 2.95 ea./cap.in pH 5.8-7.5 and 3.16 ea./cap. in $1\;cap./79.8cm^3$ during 6 weeks, respectively. pH was droped by 6.2 to 5.7, volatile solids was decreased by 2.9%, $NH_3-N$ were also reduced by $6.984{\mu}g/g$ to $0.991{\mu}g/g$. $NO_3-N$, however, were increased by $3.213{\mu}g/g$ to $7.706{\mu}g/g$. Fecal coliforms and pathogenic bacteria are analyzed by microbiological method to assess public health safety of casting. Number of fecal coliform groups were reduced 88.6-99.1% (Avg. 95.7%) approximately. And pathogenic bacteria such as Salmonella, Shiegella and Vibrio, were not isolated from the earthworm cast.

  • PDF

Optimal Condition of Operation Parameter for Livestock Wastewater Treatment using Photo-Fenton Process (PHOTO-FENTON 공정을 이용한 축산폐수처리시 운전인자의 최적조건)

  • Park, Jae-Hong;Chang, Soon-Woong;Cho, Il-Hyoung
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.3
    • /
    • pp.284-288
    • /
    • 2005
  • In this study, photochemical advanced oxidation processes (AOPs) utilizing the Photo Fenton reaction ($Fe^{2+}+H_2O_2+UV$) were investigated in lab-scale experiments for the treatment of livestock wastewater. For the experimets, the livestock wastewater was pretreated by coagulation with $3,000mg/L\;FeCl_3$. The optimal conditions for Photo-Fenton processes were determined: pH was 5, the concentration of ferrous ion (Fe II) was 0.01 M. The concentration of hydrogen peroxide was 0.1 M, and molar ratio ($Fe^{2+}/H_2O_2$) was 0.1. The optimal reaction time was 80 min. Under the optimal condition of Photo-Fenton process, chemical oxygen demand (COD), color and fecal coliform removal efficiencies were about 79, 70, and 99.4%, respectively and sludge production was 7.5 mL from 100 mL of solution.