• Title/Summary/Keyword: Fecal Microbes

Search Result 35, Processing Time 0.056 seconds

Characterizations of Water Quality, and Potential Relationships of Nitrogen Components and Microbes in the Mulgol Pond on Dokdo, Korea (독도 물골의 수질 특성 및 질소화합물과 미생물간의 잠재적 관계)

  • WOO, SANG YOON;LEE, HYEON BEEN;JEONG, DONG HYUK;AN, JE BAK;YOUN, JIN SUK;PAK, JAE-HONG;PARK, JONG SOO
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.26 no.2
    • /
    • pp.124-134
    • /
    • 2021
  • Water in the Mulgol pond on Dokdo (island), Korea, was historically used for drinking water, but now it has been no longer used for this purpose due to regionally low water quality. Since 2007, this pond has been covered with a metal lid to protect from pollutants of seabirds, indicating limited light penetration into the Mulgol pond. Here, we investigated water quality in the pond and potential relationships of nitrogen components and microbes in May, June, August, and November 2020. The source salinity ranged from 1.39 to 1.57 psu. Suspended solids (0.8~5.1 mg L-1) and chlorophyll-a (<0.01~0.49 ㎍ L-1) remained low. The concentration of dissolved inorganic nitrogen (DIN) was between 35.9 and 47.2 mg L-1. Thus, water in the Mulgol pond proves to be brackish water with low chlorophyll-a and high nutrients. This unique environment may be established by limited light intensity, sea fog (or seawater), and fecal pellets from many seabirds. Although the light source (800~8000 lux) was exposed to the four subsamples, chlorophyll-a concentrations were below <0.5 ㎍ L-1 during the incubation periods. This result suggests that the biomass of phytoplankton does not increase along with an increase in light intensity. Furthermore, the content of nitrate constituted more than 90% of DIN, and a significant negative correlation between nitrate concentration and bacterial abundance was shown in May and June 2020 during the light exposure experiments (R=-0.762, p<0.05). Thus, it is possible that bacteria may be a significant agent to reduce nitrate concentration in the Mulgol pond, the relationship between nitrate concentration and bacterial abundance may vary seasonally.

Evaluation of Water Quality Characteristics of Floor Fountains in Gwangju (광주지역 바닥분수의 수질특성 평가)

  • Kim, Jong-Min;Kim, Ha-Ram;Jang, Seo-Eun;Choi, Yeong-Seop;Kang, Yu-Mi;Jung, Sook-Kyoung;Cho, Young-Gwan;Kim, Eun-Sun
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.2
    • /
    • pp.143-156
    • /
    • 2017
  • The purpose of this study was to investigate water quality through a field survey at six floor fountain sites. The floor fountain facilities were designed and operated in such a way that tap water was stored in a water tank and recycled repeatedly. The water tank was cleaned once or twice per week in the summer. The number of facility users was low during the day due to sweltering heat, but up to 40 people, mainly children, were using them around 8 pm. Since the operation time was as short as 30 minutes, it is considered necessary to extend it for at least one hour for the number of users. As a result of the water quality test of the reservoir tank prior to operation after cleaning, it was measured to be within drinking water quality standards at the six facilities. As a result of the water quality test after use, ammonia nitrogen was measured to be 1.45 mg/L at Site IV. This exceeded the drinking water quality standard of 0.5 mg/L. In the case of turbidity, two cases exceed at 7.38 and 4.52 NTU when applying 4 NTU as the water quality standard for waterscape facilities. Twenty-eight cases exceed the standard of drinking water quality. The result of microbiological tests, at five sites excepting Site I, where disinfectant was injected, was that the maximum total colony count was 180,000 CFU/mL, total coliforms was 2,100,000 CFU/100 mL, fecal coliforms was 4,600 CFU/100 mL, Escherichia coli was 170 MPN/100 mL and Enterococcus was 100 CFU/100 mL. This exceeded the water quality standards of drinking water. Children are very likely to inhale because the water spews from below and falls from above, so it is necessary to apply water quality standards for ammonia nitrogen, turbidity and microbes. Current floor fountain facilities are highly susceptible to disease caused by microbial contamination because of water cycling and reuse, so it is necessary to change the water every day, clean the water tank, and perform chlorination. Therefore, it is necessary to inject calcium hypochlorite according to the free chlorine water quality standard of swimming pools with a different water tank capacity. In addition, facilities should be improved to prevent the reuse of water by installing the water tank at a separate location.

Supplementation of Microalgae (Tetradesmus sp.) to Pre-Starter Diet for Broiler Chickens (초기 육계 사료 내 미세조류(Tetradesmus sp.) 첨가에 따른 장관환경 변화)

  • Rim, Chae Yun;Jung, Hui-su;An, Su Hyun;Joo, Sang Seok;Kim, Z-Hun;Kong, Changsu;Kim, Myunghoo
    • Korean Journal of Poultry Science
    • /
    • v.49 no.2
    • /
    • pp.125-137
    • /
    • 2022
  • This study aimed to determine the effects of dietary microalgae (Tetradesmus sp. (TO)) on intestinal immunity and microbiota of pre-starter broilers. One hundred and twenty 1-day-old birds (Ross 308) were allocated to two dietary treatment groups with six blocks in a randomized complete block design. The two experimental diets consisted of a corn-soybean meal-based basal diet and a diet with 0.5% TO powder instead of cornstarch in the basal diet. After feeding the experimental diets for ten days, all birds' body weight and feed intake were measured, and representative eight birds were selected from each treatment group. Small intestinal lamina propria cells were isolated using flow cytometry to examine the frequency of immune cells. Cecal feces were harvested for 16s rRNA gut microbiota analysis and fecal IgA levels. Here, we found that 0.5% TO supplementation increased CD3+CD4+ T cells in the small intestine, but decreased CD3+CD8+ T cells in the small intestine. Gut microbial analysis showed that TO supplementation significantly increased the alpha diversity of the gut microbiome. Taxonomic analysis showed that TO treatment increased the abundance of Firmicutes and decreased that of Bacteroidetes at the phylum level. The distribution of Enterobacteriaceae containing many harmful bacteria at the family level, was lower in the TO group. In the LEfSe analysis, the TO group had a significantly enriched abundance of Agathobaculum at the genus level. Overall, results show that Tetradesmus sp. supplementation influences intestinal T-cell immunity and induces the expansion of beneficial gut microbes in pre-starter broiler chickens.

A Quality Assurance Study for the Application of Cook/Chill System in School Foodservice Operation (II) - Pork Bulgogi (Broiled Sliced Pork with Sauces) - (학교급식에 Cook/Chill System 적용을 위한 품질보증연구(II) - 돼지불고기 -)

  • Kwak, Tong-Kyung;Moon, Hye-Kyung;Park, Hye-Won;Hong, Wan-Soo;Ryu, Kyung;Chang, Hye-Ja;Kim, Sung-Hee;Choi, Eun-Jung
    • Journal of Food Hygiene and Safety
    • /
    • v.13 no.4
    • /
    • pp.319-331
    • /
    • 1998
  • The purposes of this study were to develop Hazard Analysis Critical Control Point plan applicable to cook/chilled Pork Bulkogi (broiled sliced pork with sauces) in school foodservice operations and to establish reasonable shelf-life limits by assessing food quality during chilled storage period of 5 days. During the product flow, time-temperature profile was recorded and microbiological analyses including mesophilic and psychrotrophic total plate counts, coliform, and fecal coliform and qualitative analyses of Salmonella and Listeria monocytogenes were done. Chemical analyses (pH, acid value, total volatile basic nitrogen), sensory evaluation, and quantitative analysis of thiamin were conducted for 5 days of chilled storage. The number of mesophiles in raw pork ($4.26{\pm}0.11\;Log\;CFU/g$), seasoning mixture ($5.97{\pm}O.04\;Log\;CFU/g$) and marinated pork ($5.56{\pm}0.21\;Log\;CFU/g$) were below the microbial standards for "requires further cooking" food items. Listeria monocytogenes was detected in seasoning mixture. After heating, the number of mesophiles ($5.17{\pm}0.04\;Log\;CFU/g$) were slightly reduced but it did not meet the microbial guidelines of $5\;Log\;CFU/g$ for "ready-to-eat" foods. No other microbes including pathogens were detected. By reheating the menu item after chilled storage, the number of mesophiles were reduced in every phase of 1st day ($4.62{\pm}0.22\;Log\;CFU/g$), 3rd day ($4.55{\pm}0.20\;Log\;CFU/g$) and 5th day ($4.25{\pm}0.16\;Log\;CFU/g$) of chilled storage, and the number of microbes was below the standard limits for "ready-to-eat" foods. At the fifth day of chilled storage, pH (p<0.05), acid value (p<0.01) and TVBN (p<0.05) showed significant increases. Sensory evaluation results did not show any significant change for 5 days of chilled storage. Thiamin content showed a decrease for 5 days of chilled storage. Consequently, the ideal shelflife recommended for Pork Bulkogi was within 3 days of chilled storage. CCPs for Pork Bulkogi were purchasing and receiving of raw meat and some seasoning ingredients, heating, chilling, chilled storage, reheating, and distribution.

  • PDF

A Quality Assurance Study for the Application of Cook/chill System in School Foodservice Operation (I) - Broiled Spanish Mackerel - (학교급식에 Cook/chill system 적용을 위한 품질보증연구(I) - 삼치구이 -)

  • Kwak, Tong-Kyung;Moon, Hye-Kyung;Park, Hye-Won;Hong, Wan-Soo;Ryu, Kyung;Chang, Hye-Ja;Kim, Sung-Hee;Choi, Eun-Jung
    • Journal of Food Hygiene and Safety
    • /
    • v.13 no.3
    • /
    • pp.278-293
    • /
    • 1998
  • The purposes of this study were to develop Hazard Analysis Critical Control Point-based standardized recipe applicable to cook/chilled Broiled Spanish Mackerel in school foodservice operations and to establish reasonable shelf-life limits by assessing food quality during chilled storage period of 5 days. HACCP for the production of menu items was identified in simulation study. At each critical control point, time-temperature profile was recorded and microbiological analysis was done. Also chemical analyses and sensory evaluation were conducted for 5 days of chilled storage. The results of time-temperature measurement of Broiled Spanish Mackerel by each production phase showed satisfactory condition that met the standards. Broiled Spanish Mackerel showed excellent microbiological quality from raw ingredient phase ($TPC:2.58{\pm}0.12\;Log\;CFU/g$) to holding phase ($TPC:2.70{\pm}0.42\;Log\;CFU/g$). Coliform (0.84 Log MPN/g) and fecal coliform (0.84 Log MPN/g) were detected from marinating phase ($TPC:3.82{\pm}0.52\;Log\;CFU/g$). After heating, only few mesophiles were detected ($TPC:1.83{\pm}0.49\;Log\;CFU/g$). No psychrophiles, coliforms and fecal coliforms were detected. In the phases after rapid chilling, during chilled storage and after reheating and distribution, almost none of the above microbes were detected. Salmonella and Listeria monocytogenes were not detected in all production phases. The pH immediately after cooking was 6.65 and then increased significantly to 6.81 on the third day of chilled storage (p<0.001). Acid value did not show significant changes while total volatile based nitrogen (TVBN) dramatitically increased during storage periods (p<0.01). In the result of sensory evaluation, general acceptability points had been rated high in the first day of storage, and then, the points were decreased significantly on the third day (p<0.05). General acceptability points ranged from 8.86 to 10.68. Accordingly, Broiled Spanish Mackerel is highly recommendable cook/chill system. Considering the DHSS standards for storage, the ideal shelf-life recommended for Broiled Spanish Mackerel is within 4 days excluding cooking day. For Broiled Spanish Mackerel, critical control points were purchasing and receiving of frozen Spanish Mackerel, heating, chilling, chilled storage, reheating and distribution.

  • PDF