• Title/Summary/Keyword: Feature function

Search Result 1,289, Processing Time 0.035 seconds

A STUDY ON STRESS DISTRIBUTION IN IMZ IMPLANT WITH A PLASTIC OR A TITANIUM IME USING FINITE ELEMENT ANALYSIS (유한요소법을 이용한 IMZ임플란트의 플라스틱 및 티타늄 IME의 응력분포에 관한 연구)

  • Ha Chi-Yang;Choi Boo-Byung;Woo Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.4
    • /
    • pp.625-642
    • /
    • 1993
  • Whether stress-absorbing elements are functional in an implant system has been an issue of interest in oral implantology. The unique feature of the IMZ implant system is the planned imitation of the stress-distributing function of the structural unit of the tooth, periodontium, and alveolar bone through the use of an intramobile element(IME). The purpose of this study was to compare the difference in the displacement and the stress distibutions of IMZ implant with a polyoxymethylene(POM) or a titanium IME under static load. Two dimensional finite element analysis(FEA) was applied for this study and two finite element models were created. PATRAN program(DPA Co.,USA), a software for FEA, and SUN-SPARC2GX(SUN Co., USA), a workstation computer, were used. $1Kg/mm^2$ of static load was loaded individually on each three point of crown of implant prosthesis ; central fossa(load 1), mesial cusp tip(load 2), distal cusp tip(load 3), The displacements of X- and Y-axis and total displacement were measured at mesial and distal cusp tips, mesial and distal points between crown and IME, and implant apex. The von Mises stress was measured at mesial and distal points between crown and IME, mesial and distal points between IME and TIE, mesial and distal alveolar crest, the mesial and distal midpoints of implant, and implant apex. The difference in resultant values were compared and evaluated statistically using paired t-test. The results were as follows : 1. Under the load 1, all the displacement of implant with titanium IME at 5 measuring points was larger than that of with POM IME except total and Y-axis displacement at implant apex. And the differences in stress distributions with POM and titanium were varied. 2. Under the load 2, all the displacement of implant with titanium IME at 5 measuring points was larger than that of with POM IME except X-axis displacement at distal cusp tip. And the differences in stress distributions were varied. 3. Under the load 3, all the displacement of implant with titanium IME at 5 measuring points was larger than that of with POM IME except Y-axis displacement at mesial cusp tip. And the differences in stress distributions were varied. 4. For the displacement, there was significant difference statistically only in total displacement (P<0.1), but was no significant difference in X- and Y-axis displacement(P>0.1). For the stress, there was no significant difference among the compared values.

  • PDF

A Study on the Properties comparison of the PVC Net and Expanded Metal Using Rockfall Protection Net Pullout Test Equipment (낙석방지망 인발시험을 이용한 PVC망과 Expanded Metal 특성비교에 관한 연구)

  • Cheon, Seongyeol;Lee, Seungho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.4
    • /
    • pp.49-57
    • /
    • 2009
  • The governmental investment to SOC facilities currently has increasedthe construction of new roads and the consistent extension of already-existing roads or the line-shape revision of those roads. As a result, the road cut slopes have been increasingrapidly. Unfortunately, human-life damages and property damages frequently occur due to the rockfall and the landslide every year. To reduce those damages, many studies have been performed. The present regulation regarding rockfall protection facilities follows the "Guide for Installation and Management of Road Safety Facilities" issued by MLTM (the Ministry of Land, Transport, and Maritime Affairs) that indicates the standard size of facilities and energy absorbing efficiencies. Most domestic road slopes use standardized rockfall protection facilities based on the regulation. However, there have been doubted about the effectiveness of rockfall protection facilities and the damages caused by rockfalls havebeen increasedevery year. Thus, it seems that relevant studies are necessary on the rockfall protection net being capable of supporting rockfall energies. Accordingly, this study reviews previous literature to investigate the function and the feature of rockfall protection nets and analyzetheir limitations by each type. After that, by using the pullout test device for a rockfall protection net, an experiment on the PVC coating net and the expanded metal is performed under the exact same condition. Finally, the features of the Expended metal is explained with the comparison analysises of load-variation and the confirmation of damaged forms. As a result, there have been founded the problemsof net breaking down and not being able to support due to PVC coating net's material property of disintegration. On the other hand, the Expanded Metal might be expected as a substituteof rockfall protection net according to its capability of support and integration.

  • PDF

Development of a Clinical Decision Support System Utilizing Support Vector Machine (Support Vector Machine을 이용한 생체 신호 분류기 개발)

  • Hong, Dong-Kwon;Chai, Yong-Yoong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.3
    • /
    • pp.661-668
    • /
    • 2018
  • Biomedical signals using skin resistance have different characteristics according to stress diseases. Biological diagnostic devices for diagnosing stress diseases have been developed by using these characteristics, and devices have been developed so that the signals measured by the skin storage meter can be easily analyzed. Experts in the field will look directly at the output signal to determine the likelihood of any stress disorder. However, it is very difficult for a person to accurately determine whether a person to be measured has a stress disorder by analyzing a bio-signal measured by each person to be measured, and the result of the judgment is very likely to be wrong. In order to solve these problems, we implemented the function of determining the signal of a stress disorder by using the machine learning technique. SVM was used as a classification method in consideration of low computing ability of measurement equipment. Training data and test data were randomly generated for each disease using error range 5 based on 13 diseases. Simulation results showed more than 90% decision accuracy. In the future, if the measurement equipment is actually applied to the patients, we can retrain the classifier with the newly generated data.

Epigenetic Regulation by Modification of Histone Methylation in Embryonic Stem Cells (히스톤 메틸화 변형을 통한 배아줄기세포의 후성 유전학적 조절)

  • Ha, Yang-Hwa;Kim, Young-Eun;Park, Jeong-A;Park, Sang-Kyu;Lee, Young-Hee
    • Development and Reproduction
    • /
    • v.15 no.4
    • /
    • pp.273-279
    • /
    • 2011
  • Epigenetic regulation is a phenomenon that changes the gene function without changing the underlying DNA sequences. Epigenetic status of chromosome is regulated by mechanisms such as histone modification, DNA modification, and RNAi silencing. In this review, we focused on histone methylation for epigenetic regulation in ES cells. Two antagonizing multiprotein complexes regulate methylation of histones to guide expression of genes in ES cells. The Polycomb repressive complex 2 (PRC2), including EED, EZH2, and SUZ12 as core factors, contributes to gene repression by increasing trimethylation of H3K27 (H3K27me3). In contrast, the Trithorax group (TrxG) complex including MLL is related to gene activation by making H3K4me3. PRC2 and TrxG accompany a variety of accessory proteins. Most prominent feature of epigenetic regulation in ES cells is a bivalent state in which H3K27me3 and H3K4me3 appear simultaneously. Concerted regulation of PRC2, TrxG complex, and H3K4- or H3K27-specific demethylases activate expression of pluripotency-related genes and suppress development-related genes in ES cells. Modified balance of the regulators also enables ES cells to efficiently differentiate to a variety of cells upon differentiating signals. More detailed insights on the epigenetic regulators and their action will lead us to better understanding and use of ES cells for future application.

Study of Catalytic Filter on the Removal of Dust and HVOC (촉매필터를 이용한 먼지 및 HVOC 제거 특성 연구)

  • Jeong, Soon Kwan;Park, Young Ok
    • Applied Chemistry for Engineering
    • /
    • v.19 no.1
    • /
    • pp.80-85
    • /
    • 2008
  • Catalytic filter is capable of performing shallow bed dust filtration plus a catalytic reaction, promoted by a catalyst deposited in its inner structure. Such a feature may allow potential cost and space reduction in several environmental applications. Dust filtration and halogenated volatile organic compound (1,2-dichlorobenzene) destruction were carried out in a lab-scale reactor. $WO_3-V_2O_5/TiO_2$ supplied by MaGreen, which showed high catalytic acitivity at low temperature, was used as a catalyst. P-84 that can be operated under $250^{\circ}C$ was used as a felt. The catalytic activity and filtration efficiency of catalytic filters were investigated under the operating conditions, including temperature, face velocity, and dust concentration. The catalytic activity of catalytic filter increased with increasing temperature and the amount of catalyst loaded. The test results showed that the filtration efficiency was primarily affected by the face velocity. Pressure drop variations as a function of time were investigated for a variety of conditions. In case of virgin filter, a dramatic decrease in the pulse interval and a slightly increase in the base line pressure drop were observed. A relatively slow pressure drop build-up was recorded for the catalytic filter due to smooth and slippery surface characteristics of nanofiber. The catalytic filter indicated that high filtration efficiency over 99.98% and high catalytic activity over 90% at 1 m/min and $210^{\circ}C$.

Computer-Aided Diagnosis for Liver Cirrhosis using Texture features Information Analysis in Computed Tomography (컴퓨터단층영상에서 TIA를 이용한 간경화의 컴퓨터보조진단)

  • Kim, Chang-Soo;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Kim, Dong-Hyun;Choi, Seok-Yoon
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.4
    • /
    • pp.358-366
    • /
    • 2012
  • Cirrhosis is a consequence of chronic liver disease characterized by replacement of liver tissue by fibrosis, scar tissue and regenerative nodules leading to loss of liver function. Liver Cirrhosis is most commonly caused by alcoholism, hepatitis B and C, and fatty liver disease, but has many other possible causes. Some cases are idiopathic disease from unknown cause. Abdomen of liver Computed tomography(CT) is one of the primary imaging procedures for evaluating liver disease such as liver cirrhosis, Alcoholic liver disease(ALD), cancer, and interval changes because it is economical and easy to use. The purpose of this study is to detect technique for computer-aided diagnosis(CAD) to identify liver cirrhosis in abdomen CT. We experimented on the principal components analysis(PCA) algorithm in the other method and suggested texture information analysis(TIA). Forty clinical cases involving a total of 634 CT sectional images were used in this study. Liver cirrhosis was detected by PCA method(detection rate of 35%), and by TIA methods(detection rate of 100%-AGI, TM, MU, EN). Our present results show that our method can be regarded as a technique for CAD systems to detect liver cirrhosis in CT liver images.

Development and Application of SITES (부지환경종합관리시스템 개발과 적용)

  • Park, Joo-Wan;Yoon, Jeong-Hyoun;Kim, Chank-Lak;Cho, Sung-Il
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.3
    • /
    • pp.205-215
    • /
    • 2008
  • SITES(Site Information and Total Environmental Data Management System) has been developed for the purpose of systematically managing site characteristics and environmental data produced during the pre-operational, operational, and post-closure phases of a radioactive waste disposal facility. SITES is an integration system, which consists of 4 modules, to be available for maintenance of site characteristics data, for safety assessment, and for site/environment monitoring; site environmental data management module(SECURE), integrated safety assessment module(SAINT), site/environment monitoring module(SUDAL) and geological information module for geological data management(SITES-GIS). Each module has its database with the functions of browsing, storing, and reporting data and information. Data from SECURE and SUDAL are interconnected to be utilized as inputs to SAINT. SAINT has the functions that multi-user can access simultaneously via client-server system, and the safety assessment results can be managed with its embedded Quality Assurance feature. Comparison between assessment results and environmental monitoring data can be made and visualized in SUDAL and SITES-GIS. Also, SUDAL is designed that the periodic monitoring data and information could be opened to the public via internet homepage. SITES has applied to the Wolsong low- and intermediate-level radioactive waste disposal center in Korea, and is expected to enhance the function of site/environment monitoring in other nuclear-related facilities and also in industrial facilities handling hazardous materials.

  • PDF

Design and Development of Middleware for Clinical Trial System based on Brain MR Image (뇌 MR 영상기반 임상연구 시스템을 위한 미들웨어 설계 및 개발)

  • Jeon, Woong-Gi;Park, Kyoung-Jong;Lee, Young-Seung;Choi, Hyun-Ju;Jeong, Sang-Wook;Kim, Dong-Eog;Choi, Heung-Kook
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.6
    • /
    • pp.805-813
    • /
    • 2012
  • In this paper, we have designed and developed a middleware for an effectively approaching database to the existed brain disease clinical research system. The brain disease clinical research system was consisted of two parts i.e., a register and an analyzer. Since the register collects the registration data the analyzer yields a statistical data which based on the diverse variables. The middleware has designed to database management and a large data query processing of clients. By separating the function of each feature as a module, the module which was weakened connectivity between functionalities has been implemented the re-use module. And image data module used a new compression method from image to text for an effective management and storage in database. We tested the middleware system using 700 actual clinical medical data. As a result, the total data transmission time was improved maximum 115 times faster than the existing one. Through the improved module structures, it is possible to provide a robust and reliable system operation and enhanced security functionality. In the future, these middleware importances should be increased to the large medical database constructions.

A comparative study on literature class in DDC and KDC (DDC와 KDC의 문학분야 비교연구)

  • 심의순
    • Journal of Korean Library and Information Science Society
    • /
    • v.14
    • /
    • pp.39-69
    • /
    • 1987
  • The purpose of this research is to analyze the differences between literature (Belles-letters) class in DDC 19 and literature class in KDC 3. The results of the study can be summarized as follows : 1. The section of philosophy and theory of literature in DDC was subdivided according to the properties as including subsection of theory of criticism but KDC didn't subdivide this section. 2. In DDC, the subsections of 'rhetoric in specific languages' and 'rhetoric of specific kinds of composition' in rhetoric section was established and can subdivide according to each languages and subjects. These considerations can be useful as compared with KDC. 3. In DDC, collections or criticism of several literatures in specific forms can be more subdivide according to specific aspects or features dealing with in the collections or criticism by a n.0, pplying Table 3-A when specified more than the literary form. 4. Reviewing a notational rank to be assigned in literatures of specific languages, Latin literature and Classical Greek literature to be ranked in division in DDC was established as subsection in KDC to treat them as literatures of minor languages. 5. The DDC can sometimes a n.0, pply, in literatures of all languages, the notations of Table 3 to be subdivided again as specific kinds of literary forms, but KDC subdivided literary forms as specific kinds of each forms in only Korean, Chinese, Japanese literature. 6. In DDC, even literatures of minor languages are provided with 'the period table for the specific literature' under each literature of specific languages in schedules and these period tables can be a n.0, pplied a n.0, ppropriately, but period numbers in KDC was established in only Korean, Chinese, Japanese literature. 7. The optional use of letter prefixes or special numbers such as 828.99 to distinguish literatures of countries other than the "mother country" which makes the use of period tables feasible, but the KDC can only use to distinguish without the function of dividing a period such as DDC. 8. According to a n.0, pplying Table 3 and 3-A also in literatures of specific languages(810-890), a literature of specific languages, a specific literary form in literature of specific languages and a literature or literary form of specific period, in case of a n.0, pplying 'form divisions 08-09', can subdivide again by a specific aspect or feature dealing with in the works when specified. 9. For grasping the rate of subdividing, after selecting several sample-titles in literary field, they classified by DDC and KDC and gave a definite score in accordance with analytic small subjects. According to the results, the rate of subdividing in literature class of KDC is proved as less 22.8% than DDC. than DDC.

  • PDF

An Expanded Use of Reactor Power Cutback System to Avoid Reactor Trips in the Event of an Inward Control Element Assembly Deviation (제어봉 인입편차시의 원자로 비상정지 방지를 위한 출력 급감발 계통의 확대 적용)

  • Hwang, Hae-Ryong;Ahn, Dawk-Hwan
    • Nuclear Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.276-284
    • /
    • 1993
  • The ABB-CE System-80 reactor power cutback system(RPCS) is designed to enable continuous operation of the reactor without trip in the events of the loss of one of the two main feedwater pumps and loss of load, and thus improves plant availability in a cost effective manner. In this study expansion of RPCS has been investigated for continuous reactor operation without trip in the event of an inward control element assembly(CEA) deviation including a single rod drop. Under the expanded function of RPCS the control system will provide a rapid core power reduction on demand by releasing CEAs to drop into the core and reduce the turbine power, if necessary, to follow the reactor power variation. This design feature which is included as the new design features to be incorporated in the ABB-CE System-80+ meets the EPRI advanced light water reactor(ALWR) requirements. For this study core analysis models of System-80+ have been developed to simulate the nuclear steam supply system(NSSS) response as well as the RPCS initiation of rapid CEA insertion. The results of this study demonstrate that the reactor trip can be avoided in the event of inward CEA deviation including a single rod drop by the RPCS initiation and thus the plant availability and capacity factor would be increased.

  • PDF