• Title/Summary/Keyword: Feasibility assessment

검색결과 645건 처리시간 0.029초

The Characteristics of Heavy Metal Distributions in the Tissues of Feral Pigeon (Columba livia) as a Bio-monitoring Indicator (환경오염 지표종인 집비둘기의 생체조직 내 중금속 분포 특성)

  • Lee, Jangho;Lee, Jongchun;Park, Jong-Hyouk;Lee, Eugene;Shim, Kyuyoung;Jang, Heeyeon;Kim, Myungjin
    • Journal of Environmental Impact Assessment
    • /
    • 제25권6호
    • /
    • pp.502-513
    • /
    • 2016
  • In this study, heavy metal distributions in the tissues of feral pigeon (Columba livia) were characterized using samples collected from bio-monitoring sites (Hangang Park and Hampyeong Park) of the NESB (National Environmental Specimen Bank), Korea, in order to evaluate the feasibility of feral pigeons as an indicator for the environmental monitoring. Cadmium (Cd) was analyzed to be accumulated in kidneys at higher concentration than in the other tissues. Such trend can also be found in the reviews on the Cd accumulations of the 34 cases including 17 avian species which showed that 31 cases had the highest Cd concentrations in the kidney among tissues. However, lead (Pb) was found to be richest in the bones in this study. 17 cases out of 30 reviewed cases had the highest Pb concentration in bones, whereas other 10 cases showed the highest concentration in kidneys, and 3 cases in livers. Therefore, kidneys together with bones can be a main target organ to test cadmium exposure to different habitat environments depending on physiological traits of birds. Zinc (Zn) was found to be the highest concentration in the pigeon livers of Hangang Park, but not in the bones. In contrast, the 13 cases of 16 reviewed cases had the highest Zn concentration in bones, and the 3 cases in livers. In addition, the heavy metal distribution patterns in relations to the metal accumulation mechanisms (a competition between Pb and Ca, a function of methallothionein protein, and etc.) were discussed.

Developing and testing the reliability of a measurement tool for an urban area food environment in Korea - Focusing on food stores - (우리나라 도시지역의 식환경 측정을 위한 조사도구 개발 및 신뢰도 검정 - 식품상점을 중심으로 -)

  • Jang, Mi Jin;Shin, Sangah;Kim, Seong-Ah;Chung, Sangwon;Paik, Hee Young;Choe, Jeong-Sook;Hong, Eun Joo;Joung, Hyojee
    • Journal of Nutrition and Health
    • /
    • 제47권5호
    • /
    • pp.351-363
    • /
    • 2014
  • Purpose: The aim of this study was to develop a reliable measurement tool to assess the urban food environment, particularly focusing on food stores in Korea. Methods: The items for the measurement tool were selected through systematic literature reviews and adjusted to the Korean food environment. A total of 25 food stores in an urban area were recruited for the pilot test to evaluate the time required for completion of the survey, ease of response, willingness to participate, difficulties in conducting the survey, and appropriateness, and 34 food stores were recruited for assessment of the reliability of the tool using percent agreement and kappa value. Results: The measurement tool is composed of questions regarding food store characteristics, accessibility, and food availability. On average, 26 minutes was required to survey a single food store, and the subjects and interviewers answered that the process was not difficult for the survey. The percent agreement for the inter-rater and test-retest reliability ranged from 93.9~98.8% and 91.9~97.9, respectively. The kappa values ranged from 0.78 to 0.97, which was very high. Percent agreement and kappa value of food with healthy option were lower than those of the general food in the inter-rater reliability (p = 0.0027, p = 0.0095 respectively) as well as in the test-retest reliability (p = 0.0081, p = 0.0290, respectively), although they were still high enough (86.4~98.0% for percent agreement, 0.64~0.96 for kappa value). Conclusion: The newly developed measurement tool for assessment of food store environment appears to be feasible and reliable; therefore, it can be applied to research on the association between food environment and dietary behaviors as well as health outcomes.

Recovery of Copper, Reuse of $TiO_2$, and Assessment of Acute Toxicity in the Photocatalytic Oxidation of Cu(II)-EDTA (Cu(II)-EDTA 광촉매 산화반응에서의 구리회수, $TiO_2$ 재사용 및 처리수 독성평가)

  • Yang, Jae-Kyu;Choi, Bong-Jong;Lee, Seung-Mok
    • Journal of Korean Society of Environmental Engineers
    • /
    • 제27권8호
    • /
    • pp.844-851
    • /
    • 2005
  • The purpose of this study was to determine feasibility of application of regenerated or recycled $TiO_2$ on the successive treatment of Cu(II)-EDTA. The recovery of copper, the reuse of $TiO_2$ and the assessment of acute toxicity was studied in the total eight successive photocatalytic reactions. Aqueous solution of $10^{-4}\;M$ Cu(II)-EDTA was treated using an illuminated $TiO_2$ at pH 6 in a circulating reactor. Two different procedures were applied in the reuse of $TiO_2$: i) recycle of $TiO_2$ without acid wash ii) regeneration of $TiO_2$ with acid wash to remove adsorbed copper in a previous experiment. The averaged decomplexation rate constant($k'_{obs}$) of Cu(II)-EDTA in recycle of $TiO_2$ without acid wash was approximately 45% less than that in regeneration of $TiO_2$ with acid wash. Removal of Cu(II) was near complete after 180 minutes in the total eight successive photocatalytic reactions using the regenerated $TiO_2$ after acid wash. In contrast, removal of Cu(II) was minimum at total fifth successive photocatalytic oxidation using the recycled $TiO_2$ without arid wash. The recovered $TiO_2$ was approximately 86% in average in each procedure. The recovered Cu(II) was 67.9% in average. The acute relative toxicity of the treated water rapidly declined at an initial reaction time up to 60 minutes but little declination was observed after 60 minutes due to little degradation of DOC. Relative toxicity of treated water using the recycled $TiO_2$ without acid wash we some what well correlated with the concentration of dissolved Cu(II). From this work, it is suggested that Cu(II)-EDTA can be effectively treated using an integrated cyclic photocatalytic oxidation with recovery of $TiO_2$ and Cu(II).

Assessment of Parameters Measured with Volumetric Pulmonary Artery Catheter as Predictors of Fluid Responsiveness in Patients with Coronary Artery Occlusive Disease (관상동맥 질환을 가진 환자에서 폐동맥카테터로 측정한 전부하 지표들은 수액부하 반응을 예상할 수 있는가?)

  • Lee, Ji-Yeon;Lee, Jong-Hwa;Shim, Jae-Kwang;Yoo, Kyung-Jong;Hong, Seung-Bum;Kwak, Young-Lan
    • Journal of Chest Surgery
    • /
    • 제41권1호
    • /
    • pp.41-48
    • /
    • 2008
  • Background: Accurate assessment of the preload and the fluid responsiveness is of great importance for optimizing cardiac output, especially in those patients with coronary artery occlusive disease (CAOD). In this study, we evaluated the relationship between the parameters of preload with the changes in the stroke volume index (SVI) after fluid loading in patients who were undergoing coronary artery bypass grafting (CABG). The purpose of this study was to find the predictors of fluid responsiveness in order to assess the feasibility of using. certain parameters of preload as a guide to fluid therapy. Material and Method: We studied 96 patients who were undergoing CABG. After induction of anesthesia, the hemodynamic parameters were measured before (T1) and 10 min after volume replacement (T2) by an infusion of 6% hydroxyethyl starch 130/0.4 (10 mL/kg) over 20 min. Result: The right ventricular end-diastolic volume index (RVEDVI), as well as the central venous pressure (CVP) and pulmonary capillary wedge pressure (PCWP), failed to demonstrate significant correlation with the changes in the SVI (%). Only the right ventricular ejection fraction (RVEF) measured at T1 showed significant correlation. with the changes of the SVI by linear regression (r=0.272, p=0.017). However, when the area under the curve of receiver operating characteristics (ROC) was evaluated, none of the parameters were over 0.7. The volume-induced increase in the SVI was 10% or greater in 31 patients (responders) and under 10% in 65 patients (non-responders). None of the parameters of preload measured at T1 showed a significant difference between the responders and non-responders, except for the RVEF. Conclusion: The conventional parameters measured with a volumetric pulmonary artery catheter failed to predict the response of SVI following fluid administration in patients suffering with CAOD.

A Feasibility Study on the Deep Soil Mixing Barrier to Control Contaminated Groundwater (오염지하수의 확산방지를 위한 대체 혼합차수재의 적용에 관한 연구)

  • 김윤희;임동희;이재영
    • Journal of Soil and Groundwater Environment
    • /
    • 제6권3호
    • /
    • pp.53-59
    • /
    • 2001
  • There is a lot of method to manage the insanitary landfill but vertical cutoff walls have been widespreadly used and were installed into the subsurface to act as a barrier to horizontal groundwater flow, The stabilized material such as specialized cement or mixed soil with additives has been generally applied for the materials of the deep soil mixing barrier in korea. The amount of the stabilized material is dependent on the field conditions, because the mixing ratio of the material and the field soil should achieve a requirement in the coefficient of permeability, lower than 1.0$\times$$10^{7}$cm/sec. This study determined the quantity and optimized function ratio of the stabilized material in the formation process of the mixed barrier that was added with stabilized material on the field soil classified into SW-SC under USCS (Unified Soil Classification System). After that the fly ash and lime were selected as an additives an that could improve the function of the stabilized material and then the method to improve the functional progress in the usage of putting into the stabilized material as an appropriate ratio was studied and reviewed. The author used the flexible-wall permeameter for measuring the permeability and unconfined compressive strength tester for compressive strength, and in the view of environmental engineering the absorption test of heavy metals and leaching test regulated by Korean Waste Management Act were performed. As the results, the suitable mixing ratio of the stabilized material in the deep soil mixing barrier was determined as 13 percent. To make workability easy, the ratio of stabilized material and water was proven to be 1 : 1.5. With the results, the range of the portion of the additives(fly ash : lime= 70 : 30) was proven to be 20-40% for improving the function of the stabilized material, lowering of permeability. In heavy metal absorption assessment of the mixing barrier system with the additives, the result of heavy metal absorption was proved to be almost same with the case of the original stabilized material; high removal efficiency of heavy metals. In addition, the leaching concentration of heavy metals from the leaching test for the environmental hazard assessment showed lower than the regulated criteria.

  • PDF

A Study on Establishing a Standardized Process for the Development and Management of Food Safety Health Indicators in Korea (우리나라 식품안전보건지표의 개발 및 운용과정 정립에 대한 연구)

  • Byun, Garam;Choi, Giehae;Lee, Jong-Tae
    • Journal of Food Hygiene and Safety
    • /
    • 제30권3호
    • /
    • pp.217-226
    • /
    • 2015
  • This study was conducted to establish a standardized process for developing food safety health indicators. With this aim, we proposed a standardized process, accessed the validity of the suggested process by performing simulations, and provided a method to utilize the indicators. Developing process for domestic environmental health indicators was benchmarked to propose a standardized process for developing food safety health indicators, and DPSEEA framework was applied to the development of indicators. The suggested standardized process consists of an exploitation stage and a management stage. In the exploitation stage, a total of 6 procedures (initial indicators suggestion, candidate indicators selection, data availability assessment, feasibility assessment, pilot study, and final indicator selection) are conducted, and the indicators are routinely calculated and officially announced in the management stage. The exploitation stage is operated by an interaction between a task force team who manages the overall process, and an advisory committee (minimum of 4 in academia, 2 in research, 4 in specialists of Ministry of Food and Drug Safety) who reviews and performs evaluations on the indicators. The standardized process was simulated with 45 initial indicators, and total of 4 indicators (17 detailed indicators) were selected: 'Proportion of domestic fruit/vegetable receiving 'acceptable' in the evaluation of pesticide/herbicide residues', 'Food-borne disease outbreaks', 'Food-borne legal infectious disease incidence', 'Salmonellosis incidence'. Synthetic food safety health index was derived by calculating percent difference with the data from 2010 to 2012. Results showed that when comparing the year 2010 to 2011, and 2011 to 2012, the overall food safety status improved by 10.37% and 9.87%, respectively. In addition, the contribution of indicators to the overall food safety status can be determined by looking into the individual indicators, and the synthetic index may be illustrated to enhance the ease of interpretation to the public and policy makers. In overall, food health safety indicators can be useful in many ways and therefore, attention should be drawn to conduct further studies and establish related legislations.

A Study on Deriving Process of a Design Alternative to the Forest Experience Center for Children through Preschooler Participatory (유아참여를 통한 유아숲체험원 설계안 도출과정에 관한 연구)

  • Kang, Tae-Sun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • 제47권5호
    • /
    • pp.1-13
    • /
    • 2019
  • This study is to derive a design alternative to the FECC (Forest Experience Center for Children) that meets the preschooler's preferences. For this purpose, preschooler participation is included in each phase of the FECC, the site perception phase, the deriving design elements phase, and the deriving design alternative phase. In this study, the process of the deriving design alternative phase was carried out with kindergarteners and preschoolers (6, 7 years olds; all 41 students) at Songsan-mulbit FECC in Gwangsan-gu, Gwangju. In order to derive the design alternatives, three detailed design processes (preschooler participation 2 times, researcher analysis 1 time), tool construction, and a preschooler participation workshop were conducted. The results of this study are as follows. First, as a result of the preschooler's design process, 41 designs were drawn, and an average of 7.66 spaces were drawn by each preschooler. The 6-year-old males designed the least (average 6.80 spaces) and the 7-year-old females designed the most (9.0 spaces). The physical and adventure play spaces were most common (38.9% to 48.7%) regardless of gender or age. To analyze the feasibility of the preschooler's design using a base map, the appearance of the physical environmental characteristics (7 items) in the site were analyzed in each of the 41 designs. As a result, the environmental characteristics were apparent a total 72 times overall. Similar environmental characteristics appearing more than once were apparent in 87.8% (26 designs) of designs. Second, three design alternatives were derived: APS- types (intensive planning of active play facility spaces) was presented in 15 designs, NS-types (planning focused on nature spaces) was presented in 14 designs, and SPS-types (planning focused on static play facility spaces) were presented 12 designs. Third, NS-type, which were finally selected through a preference assessment (5-point scale) and a comparative assessment of the three alternatives, has mainly natural spaces (forest space, forest path, shelter, natural exploration space, and ecological pond) and active play facility spaces, water play space and soil (sand) play spaces was appropriately designed. Therefore, the NS-type was analyzed as the design alternative that can fully accomplish all types of cognitive development through developed through play (functional play, constructive play, dramatic(symbolic) play).

Myocardial Tracer Uptake in SPECT Images after Direct Intracoronary Injection Of TI-201: Comparison with Stress-Reinjection Images (관동맥내 주사 TI-201 SPECT에서 심근 분절의 섭취: 부하-재주사 TI-201 영상과의 비교)

  • Seo, Ji-Hyoung;Kang, Seong-Min;Bae, Jin-Ho;Lee, Yong-Jin;Lee, Sang-Woo;Yoo, Jeong-Soo;Ahn, Byeong-Cheol;Cho, Yong-Geun;Lee, Jae-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제41권4호
    • /
    • pp.291-298
    • /
    • 2007
  • Purpose: To investigate the feasibility of TI-201 SPECT with intra coronary injection (lC-I) in the detection of viable myocardium, we have performed SPECT imaging after direct intracoronary injection of TI-201 and images were compared with those of stress-reinjection (Re-I) SPECT. Methods: Fourteen coronary artery disease patients (male 11, mean age 54 years) who had myocardial infarction or demonstrated left ventricular wall motion abnormality on echocardiography were enrolled. Three mCi of TI-201 was injected into both coronary arteries during angiography and images were acquired between 6- and 24-hour after injection. Reinjection imaging with 1 mCi of TI-201 was performed at 4-hour after adenosine stress imaging with 3 mCi of TI-201. Images were interpreted according to 4-grade visual scoring system (grade 0-3). Segments with mild to moderated uptake (${\leq}$grade 1), and upgraded more than one score with reinjection, and were defined as viable myocardium. Results: Image quality was poor in two cases with IC-I. Numbers of non-viable segments were 60 (23.8%) with IC-I, and 38 (15.1%) with Re-I, respectively. Overall agreement for perfusion grade per myocardial segment in each IC-I and Re-I was 76.5%. Overall agreement for viable segment between IC-I and Re-I was 90.5%. Only one out of 38 segments interpreted as non-viable with Re-I were interpretated as viable with IC-I. And 23 out of 214 segments interpreted as viable with Re-I were interpreted as non-viable with IC-I. Conclusion: Intracoronary TI-201 SPECT seemed to be not advantageous over stress-rest reinjection imaging in the assessment of myocardial viability, mainly due to low count statistics at 6-hour or 24-hour delayed time points. The feasibility of intracoronary TI- 201 SPECT is considered to be limited.

A Study on the Observation of Soil Moisture Conditions and its Applied Possibility in Agriculture Using Land Surface Temperature and NDVI from Landsat-8 OLI/TIRS Satellite Image (Landsat-8 OLI/TIRS 위성영상의 지표온도와 식생지수를 이용한 토양의 수분 상태 관측 및 농업분야에의 응용 가능성 연구)

  • Chae, Sung-Ho;Park, Sung-Hwan;Lee, Moung-Jin
    • Korean Journal of Remote Sensing
    • /
    • 제33권6_1호
    • /
    • pp.931-946
    • /
    • 2017
  • The purpose of this study is to observe and analyze soil moisture conditions with high resolution and to evaluate its application feasibility to agriculture. For this purpose, we used three Landsat-8 OLI (Operational Land Imager)/TIRS (Thermal Infrared Sensor) optical and thermal infrared satellite images taken from May to June 2015, 2016, and 2017, including the rural areas of Jeollabuk-do, where 46% of agricultural areas are located. The soil moisture conditions at each date in the study area can be effectively obtained through the SPI (Standardized Precipitation Index)3 drought index, and each image has near normal, moderately wet, and moderately dry soil moisture conditions. The temperature vegetation dryness index (TVDI) was calculated to observe the soil moisture status from the Landsat-8 OLI/TIRS images with different soil moisture conditions and to compare and analyze the soil moisture conditions obtained from the SPI3 drought index. TVDI is estimated from the relationship between LST (Land Surface Temperature) and NDVI (Normalized Difference Vegetation Index) calculated from Landsat-8 OLI/TIRS satellite images. The maximum/minimum values of LST according to NDVI are extracted from the distribution of pixels in the feature space of LST-NDVI, and the Dry/Wet edges of LST according to NDVI can be determined by linear regression analysis. The TVDI value is obtained by calculating the ratio of the LST value between the two edges. We classified the relative soil moisture conditions from the TVDI values into five stages: very wet, wet, normal, dry, and very dry and compared to the soil moisture conditions obtained from SPI3. Due to the rice-planing season from May to June, 62% of the whole images were classified as wet and very wet due to paddy field areas which are the largest proportions in the image. Also, the pixels classified as normal were analyzed because of the influence of the field area in the image. The TVDI classification results for the whole image roughly corresponded to the SPI3 soil moisture condition, but they did not correspond to the subdivision results which are very dry, wet, and very wet. In addition, after extracting and classifying agricultural areas of paddy field and field, the paddy field area did not correspond to the SPI3 drought index in the very dry, normal and very wet classification results, and the field area did not correspond to the SPI3 drought index in the normal classification. This is considered to be a problem in Dry/Wet edge estimation due to outlier such as extremely dry bare soil and very wet paddy field area, water, cloud and mountain topography effects (shadow). However, in the agricultural area, especially the field area, in May to June, it was possible to effectively observe the soil moisture conditions as a subdivision. It is expected that the application of this method will be possible by observing the temporal and spatial changes of the soil moisture status in the agricultural area using the optical satellite with high spatial resolution and forecasting the agricultural production.

Early Clinical Experience in Aortic Valve Replacement Using On-X$^{circledR}$Prosthetic Heart Valve (On-X$^{circledR}$ 기계판막을 이용한 대동맥판 치환술의 조기 임상 경험)

  • 안병희;전준경;류상완;최용선;김병표;홍성범;박종춘;김상형
    • Journal of Chest Surgery
    • /
    • 제36권9호
    • /
    • pp.651-658
    • /
    • 2003
  • Since the first implanted in September 1997, the use of On-X prosthetic heart valve has been increasing around in the world. This study was designed to assess the feasibility, safety, and the postoperative hemodynamics with this new valve in clinical setting. Material and Method: The current study was carried out on 52 patients undergoing aortic valve replacement with this prosthesis between April 1999 to August 2002 at Chonnam National University Hospital to evaluate the surgical results. 52% of the patients were male and the average age at implant was 50$\pm$13 years. The study followed the guidelines of the AATS/STS. Preoperatively, 32(61.5%) patients were in NYHA functional class III or IV and 2 patients had previous aortic valve surgery. Concomitant cardiac surgery was performed in 71.1%. The implanted valve sizes were 19 mm in 13 patients, 21 mm in 26, 23 mm in 10 and 25 mm in 3, respectively. Mean follow-up was 16.6$\pm$10.5 months (1∼39 months). Echocardiographic assessment was performed pre- and immediate postoperatively, as well as 3, 6, 12 months after surgery, evaluating pressure loss and regression of left ventricular hypertrophy. Result: Mean cardiopulmonary bypass time was 191$\pm$94.7 minutes with an aortic cross-clamp time of 142$\pm$51.7 minutes. There was no early and late mortality, Freedom from adverse events at 1 year in the study were as follows: thromboembolism, 95.6$\pm$6%; bleeding events, 90.2$\pm$4%; paravalvular leakage 92.3$\pm$4%; and overall valve-related morbidity at 1 year was 76.6$\pm$3%. There were no cases of valve thrombosis, prosthetic valve endocarditis and structural or non-structural failure. Left ventricular function at 12 months after surgery (EF=62.7$\pm$9.8%) revealed a statistically significant improvement compared to preoperative investigation (EF=55.8$\pm$15.9%, p=0.006). Left ventricular mass index was 247.3$\pm$122.3 g/$m^2$ on preoperative echocardiographic study, but regressed to 155.5$\pm$58.2 g/$m^2$ at postoperative 1 year (p=0.002). Over the follow-up period a further decrease of peak transvalvular gradients was observed in all patients: 62.5$\pm$38.0 mmHg on preoperative assessment, 18.2$\pm$6.8 mmHg at immediate postoperative period (p < 0.0001), 7.6$\pm$5.09 mmHg (p<0.0001) at 6 month, 18.0$\pm$10.8 mmHg (p<0.0001) at 1 year. Conclusion: The On-X prosthetic heart valve performs satisfactorily in the first 1 year period. Clinical outcome by examining NYHA functional classification revealed especially good results. Effective regression of left ventricular hypertrophy and statistically significant decrease of transvalvular gradient were observed over the first year, but longer-term follow-up of this patient group is needed to establish the expected rates for late valve-related events as well as the long-term clinical efficacy of this valve.