• 제목/요약/키워드: Fault parameters

검색결과 469건 처리시간 0.033초

고압 수용가용 배전반의 intelligent화 연구 (A Study on the Intelligent High Voltage Switchboard for Custormer)

  • 변영복;조기연;구헌회
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.444-446
    • /
    • 1994
  • This paper describes the design of a digital multifunction controller for the intelligent high voltage customer switchboard and proposes a relaying algorithm for high impedance faults using back-propagation neural network. The hardware design uses the three microprocessors and global memory architecture to achive real time operation and control 4 feeders. The controller uses a 64-point radix-4 DIF FFT algorithm to measure the harmonic and relay parameters. Synthesized fault current waveforms are used to train and test the back - propagation network.

  • PDF

계통조건에 의한 거리계전기의 응동특성에 관한 연구 (A Study on the Operational Characteristic of Distance Relay According to Power System Condition)

  • 정창호;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.290-293
    • /
    • 2001
  • This paper presents the reach accuracy of a distance relay for protection of transmission line according to power system conditions. The apparent impedance of distance relay is considerably affected by source impedance, load current, power factor, fault point and resistance etc. For protective coordination on the variables power system parameters, trip characteristics of distance relay at sending and receiving terminal are discussed.

  • PDF

진동모드를 이용한 링 구조물의 결함 탐지 (Fault detections in ring structures using vibration modes)

  • 김석현;장호식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1925-1932
    • /
    • 2000
  • Damage detection methods using vibration modes are investigated on ring structures and. modal behavior of the slightly asymmetric rings is examined. Mode shapes changes, MSER(modal strain energy ratio) and MCR(modal curvature ratio) are applied to identify the locations of faults or damages. Parameters are calculated and compared by finite element analysis on rings with designed local damages. Damages are modeled as reduced stiffness in the analysis. The results show MSER and MCR can be proper factors to detect local damages in ring structures.

  • PDF

유한 요소법에 의한 속응 여자 초전도 발전기의 과도 특성 해석 (Transient Characteristic Analysis of Quick Response Extraction Type Superconducting Generator by Finite Element Method)

  • 김정철;한성진
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제2권2호
    • /
    • pp.26-31
    • /
    • 2000
  • This paper deals with finite element analysis of 2GVA superconducting generator which has slitted electrothermal shield in d-axis (SES). Three phase fault is considered torque of the S.C.G. Using the result, generator parameters are calculated by F.E.M. The results are compared with superconducting generator having conventional electrothermal shield (CES). The result shows that quick response excitation could be applied to superconducting generator with slitted electrothermal shield.

  • PDF

유한 요소법을 이용한 속응여자방식 초전도 발전기의 정수 산정 (Parameter Estimation of Quick Response Excitation type Superconducting Synchronous Generator by F.E.M)

  • 김정철;한성진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.600-602
    • /
    • 2000
  • This paper deals with finite element analysis of 2GVA superconducting generator which has slitted electrothermal shield in d-axis. Open emf voltage is calculated and three phase fault is considered to Predict the generator parameters by F.E.M. Results show that quick response excitation could be applied to superconducting generator with slitted electrothermal shield.

  • PDF

유도전동기의 운전 특성 예측을 위한 동적 시뮬레이터 구성 (Implementation of the Dynamic Simulator for Predicting Operating Characteristics of Three-Phase Induction Motors)

  • 변한섭;한성진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.906-908
    • /
    • 2000
  • This paper presents dynamic modeling and simulation of induction motors. Equivalent circuit parameters measured by do test, no-load test and locked-rotor test were used as the input data for computer simulation. Operating characteristics of an induction motor were predicted by Matlab/simulink when changing load torque, opening and reclosing of phase a of the stator and three-phase fault at machine terminals.

  • PDF

매계분수 기정에 의한 동기식의 모델링에 관한 연구 (A study on the Synchronous Machine Modeling by Parameter Modification)

  • 김준현;유석구;설용태
    • 대한전기학회논문지
    • /
    • 제32권11호
    • /
    • pp.379-386
    • /
    • 1983
  • In this paper,the more accurate and simple synchronous machine model is derived by parameter modification method. At first, the flux linkage state space model is composed by redefining the parameters of synchronous machine and considering the saturation effect approximately. After that, this modified model is apply to the power system model and the effects of power system stability is analyzed by this model's characteristics in fault condition. As the result, the modified synchronous machine model shows more accurate and simple than the privious one.

  • PDF

지중송전 및 배전계통의 공통접지에 따른 과도상태 영향 분석 (Analysis of Effect on the Transient State According to Common Grounding between Underground Transmission Systems and Distribution Systems)

  • 임광식;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.740-741
    • /
    • 2007
  • This paper analyses the transient state of underground distribution system against single line to ground fault in underground transmission systems, when underground transmission systems and distribution systems are made of common grounding. Underground transmission systems and distribution systems are modeled by EMTP/ATPDraw. Simulation is carried out considering variation of parameters such as value of common grounding, balance load and unbalance load.

  • PDF

전력사용 시설물의 Pattern Search 법을 이용한 최적 접지 설계에 관한 연구 (A Study on the Optimal Grounding Design using Pattern Search Method for Electric Power Facilities)

  • 김경철;최병숙
    • 조명전기설비학회논문지
    • /
    • 제16권1호
    • /
    • pp.58-66
    • /
    • 2002
  • 전력사용 시설물은 사고시 대지에 전류를 흘려 보내고, 시설물의 손상, 화재와 인체의 감전 충격을 방지하기 위해서 반드시 효과적인 접지를 하여야 한다. 본 논문에서는 Pattern Search법을 이용하여 접지시스템의 최적의 각종 파라메터를 구하고자 한다. Pattern Search법을 이용하여 구한 파라메터를 입력으로 하여 시뮬레이션한 결과 최적의 접지 시스템을 확인하였다.

융통전력 여유 향상을 위한 BTB 컨버터 제어 전략 수립 (On Control Strategies for BTB Converters for Enhancement of Interface Flow Margins)

  • 온성민;송화창;장병훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.374-375
    • /
    • 2011
  • This paper presents a method to determine parameters of BTB (back-to-back) converters in terms of the enhancement of interface flow margins. Interface flow margin is by definition a measure of how much active power can be transferred from the external areas to the study area with the fixed load demand, and it is mainly constrained by system voltage stability. BTB converters are controllable equipments with the active power flow through them, and its DC link in fact can divide the AC systems at the location and hence can reduce the fault current level. This paper first cals margin sensitivities at the nose point of F-V curves and formulates an optimization problem to update the BTB parameters to improve the margins. This procedure is repeated performed until the required margin enhancement is achieved.

  • PDF