• 제목/요약/키워드: Fault parameters

검색결과 471건 처리시간 0.026초

송전계통 보호계전기 보호협조 평가 시스템 (A Software System for Evaluation Setting and Coordination of Protective Relays in Power Transmission System)

  • 최면송;이승재;민병운;조필성
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권10호
    • /
    • pp.518-524
    • /
    • 2002
  • A software system that has functions of setting and coordination checking of protective relays in power transmission system has been developed. The developed system utilizes database system to store the setting values of protective relays, power system parameters, checks the relay operation and evaluates coordination of relays in real Power system or test system. The fault data to simulates a fault to evaluate the coordination of relays is generated by PSS/E and EMTP. A universal logic generator module is added to adopt the variation of each relay's trip logic. The proposed system has been verified through many tests in the case study, and proved to be very powerful in inspecting the setting values and coordination of relays.

송전선로 고장과 LPATS 낙뢰자료 DB와의 비교분석에 관한 연구 (A study on the comparison/analysis between the fault of transmission line and the LPATS lightning data)

  • 우정욱;심응보;김정부;이건웅;민병욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2073-2075
    • /
    • 1999
  • To study the basic research of the lightning parameter for power system operation. LPATS(Lightning Position and Tracking System) has been introduced since 1995 in KEPCO. We have developed the lightning parameter analysis program. We obtained the various statistical distribution of lightning current parameters from 1995 by this program. In this paper, we describe the results on the comparison/analysis between the fault of transmission line and the LPATS lightning data.

  • PDF

직류전동기 구동 원심펌프-파이프 계통의 고장검출진단시스템: 등가관계 접근법 (Fault Detection and Isolation System for DC motor driven Centrifugal Pump-Pipe Systems: Parity Relation Approach)

  • 박태건;류지수;이기상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 B
    • /
    • pp.819-821
    • /
    • 1998
  • This paper deals with a method or a residual generation for fault isolation in a centrifugal pump with a water circulation system, driven by a speed controlled dc motor. It is based on parity relations derived from the moving-average model of the system and is used to identify sensor faults and two possible brush and impeller faults, where the former is dealt with additive faults, while the latter characterized as discrepancies between the nominal and actual plant parameters of the system is modelled by multiplicative faults. We will represent the propagation of this uncertainty to the model matrices by the approximate handling of partial derivatives of polynomials. With multiplicative faults, the transformation matrix implemented in the residual generator are calculated on-line. The simulation studies demonstrate that small changes of the system can be detected and diagnosed by using the method.

  • PDF

국내 지진기록의 통계적 분석에 기반한 스펙트럴 가속도 응답 예측기법 (Prediction of Spectral Acceleration Response Based on the Statistical Analyses of Earthquake Records in Korea)

  • 신동현;홍석재;김형준
    • 한국지진공학회논문집
    • /
    • 제20권1호
    • /
    • pp.45-54
    • /
    • 2016
  • This study suggests a prediction model of ground motion spectral shape considering characteristics of earthquake records in Korea. Based on the Graizer and Kalkan's prediction procedure, a spectral shape model is defined as a continuous function of period in order to improve the complex problems of the conventional models. The approximate spectral shape function is then developed with parameters such as moment magnitude, fault distance, and average shear velocity of independent variables. This paper finally determines estimator coefficients of subfunctions which explain the corelation among the independent variables using the nonlinear optimization. As a result of generating the prediction model of ground motion spectral shape, the ground motion spectral shape well estimates the response spectrum of earthquake recordings in Korea.

결함허용 분산시스템의 재분배 알고리즘의 시뮬레이션과 평가 (Simulation and Evaluation of Redistribution Algorithms In Fault-Tolerant Distributed System)

  • 최병갑;이천희
    • 전자공학회논문지B
    • /
    • 제31B권8호
    • /
    • pp.1-10
    • /
    • 1994
  • In this paper load redistribution algorithm to allow fault-tolerance by redistributing the workload of n failure nodes to the remaining good nodes in distributed systems are investigated. To evaluate the efficiency of the algorithms a simulation model of algorithms is developed using SLAM II simulation language. The job arrival rate service rate failure and repair rate of nodes and communication delay time due to load migraion are used as parameters. The result of the simulation shows that the job arrival rate failure and repair rate of nodes do not affected on the relative efficiency of algorithms. If the communication delay time is greater than average job processing time algorithm B is better. Otherwise algorithm C is superior to the others.

  • PDF

연계점에서의 복소전력을 이용한 단독운전 판단기법 (Islanding Detection Based on Complex Power at the Intertie)

  • 강용철;차선희;장성일;강해권;김용균;박군철
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2167-2172
    • /
    • 2008
  • A large scale embedded generator or a micro-grid is usually interconnected to the grid through the dedicated line. Immediately after the removal of the grid supply, it must be disconnected and remain disconnected until the normal grid supplies are restored. This paper proposes an islanding detection algorithm based on complex power at the intertie. Complex power at the intertie delivered to the grid has a value depending on power flow during normal operation. When loss of mains occurs, complex power at the intertie moves to a value depending on the parameters of the dedicated line. The performance of the proposed algorithm was investigated under various operating and fault conditions. The proposed algorithm can detect an islanding operation even if no power is exchanged prior to loss of mains and discriminate the fault condition from islanding.

배전선로 고장징후 예지 시스템 개발에 관한 연구(I) (A Study for the Prediction Method of Fault Symptoms on Distribution Feeders(I))

  • 신정훈;김태원;박성택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1213-1216
    • /
    • 1998
  • This paper presents the result of a feasibility study for the prediction method of fault symptoms on 22.9kV distribution line. In this paper, real distribution data was collected and analyzed to isolate failure signatures or parameters which were distinct behaviors before and after failure incident. A new strategy of analysis-based (event-date concept) prediction algorithm for the distribution insulators and a developed model system were also discussed.

  • PDF

뉴로-퍼지기법을 이용한 송전선로의 고장검출 (Fault Detection of Transmission Line using Neuro-fuzzy Scheme)

  • 전병준;박철원;신명철;이복구;권명현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1046-1049
    • /
    • 1998
  • This paper deals with the new fault detection technique for transmission line using Neuro-fuzzy Scheme. Neuro-fuzzy Scheme is ANFIS(Adaptive-network Fuzzy Inference System) based on fusion of fuzzy logic and neural networks. The proposed scheme has five layers. Each layer is the component of fuzzy Inference system and performs different action. Using learning method of neural network, fuzzy premise and consequent parameters is tuned properly.

  • PDF

RC 교각의 내진거동 평가를 위한 진동대 실험 (Shake Table Tests for the Evaluation of Seismic Behavior of RC piers)

  • 정영수;심창수;박창규;박창영
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.85-88
    • /
    • 2006
  • This paper deals with shaking table tests on RC piers to evaluate the seismic performance under near fault motion. Small scale models were fabricated and axial force was applied by introducing prestress at the centroid of the column section. Mass effect of the superstructures was simulated by mass frame which was linked with a pier model by steel bars because of the limited payload of shaking table. Friction of the mass frame when it moves was minimized by special details and it was proved before tests. Scale factor of the RC piers was 4.25. Main parameters of the test were details of reinforcements. After verifying the results of shaking table tests, seismic performance was evaluated by increasing the acceleration of the near fault motion.

  • PDF

비선형계통 고장진단을 위한 온-라인 퍼지동적모델 식별 (Identification of Fuzzy Dynamic Model for Fault Diagnosis of Nonlinear System)

  • 이종렬;배상욱;이기상;박귀태
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 1998년도 추계학술대회 학술발표 논문집
    • /
    • pp.204-210
    • /
    • 1998
  • This paper discusses an on-line fuzzy dynamic model(FDM) identification of nonlinear processes for the design of fuzzy model based fault detection and isolation(FDI). The dynamic behavior of a nonlinear process is represented by a fuzzy aggregation of a set of local linear models. The identification is divided into two procedures. The first is the off-line identification of membership function. The second is the on-line identification of the local linear models. Then, we propose a residual generation scheme based on the parameters of local linear models and show that the scheme can be used for the design of FDI

  • PDF