• Title/Summary/Keyword: Fault line

Search Result 1,139, Processing Time 0.025 seconds

New leakage detection system for the hydraulic system of EHV underground oil-filled cables (초고압 OF 케이블 급유계통의 조기이상검지시스템)

  • Kim, Y.;Seong, J.K.;Han, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1966-1968
    • /
    • 2000
  • Globally, oil-filled paper-insulated cables and cross-linked polyethylene-insulated cables have been mainly applied for a underground power transmission line. The oil-filled cable has the hydraulic system in which insulating oil, expanded and contracted by temperature changes, is absorbed and supplied. This system enable us to detect oil leakages from the cable. But it has some problems such as difficulty in detecting minor leakages and a relatively long period of fault detecting. And so, this paper introduce a new leakage detection system, improved from the current one.

  • PDF

A Study of the Preventive Diagnostic Algorithm of Gas in Oil for Power Transformer (가스분석을 이용한 변압기의 이상진단 알고리즘 연구)

  • Choi, I.H.;Kweon, D.J.;Jung, G.J.;You, Y.P.;Sun, J.H.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1903-1905
    • /
    • 2000
  • Power transformers have a tendency of ultra-high voltage capacity as power demand increases day after day KEPCO also will have plan to supply transmission power from 345KV to 765KV in the early of 2000. Therefore, the fault by insulation destruction gives rise to large area of power failure in huge capacity transformers. On-line predictive diagnostics is very important in power transformers because of economic loss and its spreading effect. This study presents the algorithm for transformer oil analysis used KEPCO code, IEC code, gas pattern method and Dornenburg & Roger Ratio method. We also describe the MMI display of expert system programmed by Element Expert Tool(Neuron Data Inc.).

  • PDF

Ananalzing fault current and Protective coordination in the underground line (지중배전선로의 고장전류 크기 및 보호협조분석)

  • Cho, Nam-Hun;Ha, Bok-Nam;Lee, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.932-934
    • /
    • 1998
  • Electric power distribution feeders are susceptible to faults caused by a variety of situations such as adverse weather conditions, tree contacts, equipment failure, accidents, etc. Distribution circuit faults result in a number of problems related to the reliability of service and customer power quality. In the past, the permanent interruption of customer service resulting from a blown fuse or a recloser lockout was the only factor which was used to determine service reliability. So we developed KODAS(Korea Distribution Automation System) with successful and had fieid-testing of Distribution Automation System in last three years at Kang-dong Branch Office. In performing the project, KEPRI has gained valuable experience, through dealing with many difficult problem. This paper is depicted about the circuit breaker coordination problems in the Underground for the Distribution Automation Feeder.

  • PDF

Parameter Identification of Nonlinear Systems using Hopfield Network (Hopfield 신경망에 의한 비선형 계통의 파라미터 추정)

  • Lee, Kee-Sang;Park, Tae-Geon;Ham, Jae-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.710-713
    • /
    • 1995
  • Hopfield networks have been applied to the problem of linear system identification. In this paper, Hopfield network based parameter identification scheme of non-linear dynamic systems is proposed. Simulation results demonstrate that Hopfield network can be used effectively for the identification of non-linear systems assuming that the system states and their time derivatives are available. Therefore, the proposed scheme can be applied in fault detection and isolation(FDI) and adaptive control of non-linear systems where the Hopfield networks perform on-line identification of system parameters.

  • PDF

A Current Differential Relaying Algorithm for Transmission Lines Using an Advanced Compensation Algorithm of CTs (보상알고리즘을 적용한 송전선 보호용 전류차동 알고리즘)

  • Kang, Y.C.;Lim, U.J.;Choi, J.W.;Jin, S.Y.;Cho, H.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.323-325
    • /
    • 2003
  • A current differential relay may maloperate for external faults with CT saturation and requires an additional method to cope with the problem. This paper proposes a current differential relaying algorithm for transmission line protection using an advanced compensation algorithm of the secondary current of CTs. The compensation algorithm is unaffected by a remanent flux. The proposed algorithm does not need an additional method for CT saturation and thus can achieve high stability for an external fault.

  • PDF

An Adaptive Relaying Algorithm on Utilities' Electrical Feeders for Improving the Reliable Operation of Wind Farm Interconnected with Utility Grid (계통 연계 풍력발전단지의 운전효율 향상을 위한 배전 계통의 적응형 보호 계전 알고리즘)

  • Jang, Sung-Il;Kim, Ji-Won;Choi, Don-Man;Kim, Kwang-Ho;Kim, Hyung-Rae
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.338-341
    • /
    • 2003
  • This paper proposes the adaptive relaying algorithm of protective devices applied in the neighboring distribution feeders for reliable and efficient operations of a wind farm interconnected with distribution networks by dedicated lines. Generally, it would be highly possible that the wind turbine generators are influenced by abnormal grid conditions such as disturbances occurring in the neighboring distribution feeders as well as the dedicated power line. The delayed operation time of protective devices for satisfying the coordination might overly expose the interconnected wind turbine generators to the fault and cause damage to them. In order to reduce the damages on the interconnected wind farm about the faults happening in distribution networks, this paper describes the proper delayed operation time of protective relay.

  • PDF

High Repair Efficiency BIRA Algorithm with a Line Fault Scheme

  • Han, Tae-Woo;Jeong, Woo-Sik;Park, Young-Kyu;Kang, Sung-Ho
    • ETRI Journal
    • /
    • v.32 no.4
    • /
    • pp.642-644
    • /
    • 2010
  • With the rapid increase occurring in both the capacity and density of memory products, test and repair issues have become highly challenging. Memory repair is an effective and essential methodology for improving memory yield. An SoC utilizes built-in redundancy analysis (BIRA) with built-in self-test for improving memory yield and reliability. This letter proposes a new heuristic algorithm and new hardware architecture for the BIRA scheme. Experimental results indicate that the proposed algorithm shows near-optimal repair efficiency in combination with low area and time overheads.

A Study on the Fault analysis of train control system by CAMS (CAMS에 의한 고속선 열차제어시스템 장애 분석에 관한 연구)

  • Kim, Yong-Kyu;Baek, Jong-Hyun;Ryu, Sang-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1436-1441
    • /
    • 2006
  • In this paper, Computer-aided Maintenance Equipments, which are being used in High Speed Line Train Control System, are applied to analyze failures in train control systems, resulting in long time delays of trains. It can be expected to extend and apply CAMS(Computer Aided Maintenance System) in the hereafter efficient operation and maintenance of high speed railway train control systems, by comparison between the analysis result of fundamental causes, from high speed railway train control system failure occurred during the operational process, and predictive result of failure causes, based on the recording data of CAMS when failures were occurred.

  • PDF

A Study on the Load Flow Program for 765[㎸] Substation Simulator (765[㎸] 변전소 시뮬레이터를 위한 조류계산 프로그램에 관한 연구)

  • 여상민;김철환;이종포
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.4
    • /
    • pp.201-206
    • /
    • 2003
  • Power system is analyzed by three methods of load flow, fault calculation, and voltage stability. Among there, load flow is calculated to flow of power in power in system at steady state. But, load flow is difficult to analyze to flow of power in substation, because power flow frequently alter by various equipments such as circuit bleaker, disconnect switch and shunt reactor. Particular, in 765[㎸] system, because of form of 1.5GB for stable operation, structure of substation has been very complex. In this paper, we describe technique for application of load flow algorithm in simulator for 765[㎸] substation. For this technique, we built each database for various equipments and considered form of 1.5GB Data as form of bus and line, for application of load flow, are acquired from built database, and then calculate load flow in substation. And. results of load flow are outputted in screen of operator console program.

Automatic Measuring Apparatus for Salt and Dust Contamination (염진해 오손도 자동측정장치)

  • 최남호;구경완;이명섭;한상옥;정재기;조성배
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.187-190
    • /
    • 1999
  • To reduce the maintenance expence, and the possibility of electric outage and accident, accurate measurement should be carried. But the classical method has some problems in the aspect of man power, reliability, and expence. In this paper, we propose a new type apparatus, which could detect the degree of contamination on insulators on outdoor insulation system, such as transmission and distribution line insulator and bushing. The new type apparatus consists of Pelltier module, electrode system, and measuring part. At first leakage current detecting method was considered, then with the fault(oxidation of electrode) of that method we should propose a another method. We carried various test to prove the possiblity and reliability of the propoused apparatus. And we get some useful result with laboratory test.

  • PDF