• Title/Summary/Keyword: Fault line

Search Result 1,138, Processing Time 0.028 seconds

Protection System Characteristics Analysis by Compensation Equipment in Power Systems (보상제어 설비의 운용에 따른 보호설비 특성분석)

  • Park, Ji-Hoon;Sul, Tong-Tae
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1006-1008
    • /
    • 1998
  • This paper describes the possible undesier-able side effects that thyristor controlled compensation may have upon in several relays. This process consisted of calculating line conditions for each of the fault, compensation and loading levels. In some cases their effectiveness at coordinating compensated lines is lost, as they no longer can always accurately determine "distances" to faults.

  • PDF

Improvement Method of Supplying Reliability on the Electric Railway Power Distribution System (전기철도 고압배전시스템의 공급신뢰도 향상 방안 연구)

  • Kim Young-Sun;Chang Sang-Hoon;Kim Wang-Gon
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.682-687
    • /
    • 2005
  • High quality power supplying of power distribution system in electric railway system is the important function. Power feeding system is complicated witch is compose with distribution line, circuit break, protection facilities and so on. Among this components, role of substation is most important for elevation of reliability in electric power system. Therefore, the enhanced reliability considering the preventive inspection, repair work, replacement is necessary. In this study, a proposed the enhanced reliability method through a calculation of fault probability in power feeding system.

  • PDF

Area Usage Factor Analyzing Method for Semi-conductor Manufacturing Process

  • Konishi, Katunobu;Ukida, Hiroyuki;Sawada, Koutarou
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1998.10a
    • /
    • pp.480-483
    • /
    • 1998
  • For memory products, it is very important to develop a new production line as soon as possible. All products are inspected to get rid of defected products at the last testing stage. Those inspection data are called FCM. In this paper, based on the FCM data, Area Usage Factor (AUF) analyzing method will be proposed. Process engineers can make up their mind to which direction they should concentrate their analyzing power.

  • PDF

Characteristics of Superconducting Elements in Series-Connected Three-Phase Flux-Lock type SFCL (3상 자속구속형 한류기의 초전도 소자 직렬연결 특성분석)

  • Park, Hyoung-Min;Choi, Hyo-Sang;Cho, Yong-Sun;Hwang, Jong-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.35-36
    • /
    • 2007
  • We investigated the characteristics of three phase flux-lock type SFCL. Three phase flux-lock type consists of three reactor wound on an iron core in each single phase and the secondary coil is connected to the superconducting elements in series. the superconducting elements with serial connection were quenched simultangously in the single line-to-ground fault.

  • PDF

Analysis of Effect on the Transient State According to Common Grounding between Underground Transmission Systems and Distribution Systems (지중송전 및 배전계통의 공통접지에 따른 과도상태 영향 분석)

  • Lim, Kwang-Sik;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.740-741
    • /
    • 2007
  • This paper analyses the transient state of underground distribution system against single line to ground fault in underground transmission systems, when underground transmission systems and distribution systems are made of common grounding. Underground transmission systems and distribution systems are modeled by EMTP/ATPDraw. Simulation is carried out considering variation of parameters such as value of common grounding, balance load and unbalance load.

  • PDF

The Additional Functions and Data Transmission Flow Diagram for Effective Operation of Distribution Automation System (배전자동화시스템의 효율적인 운용을 위한 구가기능 및 정보전송체계)

  • Lee, Jung-Ho;Ha, Bok-Nam;Cho, Nam-Hun
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.211-213
    • /
    • 1998
  • This paper introduces the additional remote monitoring and remote setting functions needed to operate the distribution automation system effectively. we compare the additional functions with the old functions. The remote setting of minimum trip value of fault indicator is an example of additional function. It saves time and line-man's power. Also this paper describes the data transmission flow diagram for operation of distribution automation system using wireless communication method.

  • PDF

Experimental Studies on the Risk Assessment of Electrical Fire and Shock of LED Lighting for Outdoor (옥외용 LED 조명의 전기화재 및 감전 위험성 평가에 대한 실험적 고찰)

  • Kim, Hyang-Kon;Gil, Hyoung-Jun;Kim, Dong-Ook;Kim, Dong-Woo;Lee, Ki-Yoen;Moon, Hyun-Wook;Kim, Hyeog-Soo;Kim, Myung-Soo;Kim, Man-Geon
    • Congress of the korean instutite of fire investigation
    • /
    • 2011.04a
    • /
    • pp.77-97
    • /
    • 2011
  • In this paper, we studied risk assessments of electrical fire and shock of LED lightings for outdoor. We examined national regulations about the LED lighting for outdoor and analyzed the appearances and compositions of LED lightings. And, We experimented about water proof, line to line fault, line to line breakdowm, overvoltage, line to line leakage in overhead line or water of LED lighting. From experimental results, we know that there are risks of electrical fire and shock by abnormal conditions at the LED lighting. Therefore, the uses of protective devices and insulated type of converter are required for the electrical safety. We expect that the results of this study would be helpful for the improvement of regulations and standards for electrical safety and for the investigations of electrical accidents of LED lightings.

  • PDF

The Design of the DC traction Protection system and Device for the test line of Light Rail Transit (경전철 시험선로의 직류 보호시스템 및 보호계전기 설계)

  • Jeon, Y.J.;Kim, J.H.;Baek, B.S.;Kim, N.H.;Lee, B.S.;Ahn, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1229-1231
    • /
    • 2002
  • This paper presents the design of DC protection system of Light Rail Transit system. Especially, the composition and interface for DC Switchgear. Digital protection unit and sort of protection algorithm are focused. DC Switchgear (DCSWGR) for LRT testline consist of 5 different panels with peculiar characteristics are examined. Also Basic actuation principle for DC fault select relay (50F), Line Test Device (LTD), DC Overcurrent(OCR) relay are introduced.

  • PDF

On UFR Settings Considering Wind Power Fluctuation In Jeju Island (제주도 풍력발전기 출력변동성을 고려한 적정 UFR 차단방식 연구)

  • Park, Min-Su;Chun, Yeong-Han;Byun, Sung-Hyun;Yang, Jeong-Jae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.4
    • /
    • pp.445-450
    • /
    • 2014
  • Jeju power system is connected to the mainland power system through HVDC, and receives about half of required electricity through the HVDC lines. Jeju power system already experienced black out when a generator tripped at the moment of the HVDC line faults. But, UFR operated as was expected when HVDC line fault occurred at that time. As the penetration level of wind turbines increases, it is required to set UFR again considering intermittent wind turbin outputs. In this paper, we address a new way of UFR setting through computer simulation.

Development of Inspection Tool for 154kV Live-line Insulator string (154kV 활선 애자련의 불량애자를 검출하는 활선애자 점검기 개발)

  • Lee, Jae-Kyung;Park, Joon-Young;Oh, Ki-Yong;Jo, Byeong-Hak
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.373-374
    • /
    • 2008
  • To prevent an insulator failure, a new inspection system is presented for 154kV insulator strings. The inspection system detects fault insulators by measuring resistance and voltage of each insulators in the 154kV insulator string. The inspection instrument obtains autonomously insulation resistance and assigned voltage along the insulator string. The insulator inspection instrument is manipulated by two operators. In addition, a set of mechanism is applied to prevent the system from being reset under live-line condition. We confirmed its effectiveness through experiments.

  • PDF