• Title/Summary/Keyword: Fault line

Search Result 1,138, Processing Time 0.025 seconds

Run-to-Run Fault Detection of Reactive Ion Etching Using Support Vector Machine (Support Vector Machine을 이용한 Reactive ion Etching의 Run-to-Run 오류검출 및 분석)

  • Park Young-Kook;Hong Sang-Jeen;Han Seung-Soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.5
    • /
    • pp.962-969
    • /
    • 2006
  • To address the importance of the process fault detection for productivity, support vector machines (SVMs) is employed to assist the decision to determine process faults in real-time. The reactive ion etching (RIE) tool data acquired from a production line consist of 59 variables, and each of them consists of 10 data points per second. Principal component analysis (PCA) is first performed to accommodate for real-time data processing by reducing the dimensionality or the data. SVMs for eleven steps or etching m are established with data acquired from baseline runs, and they are further verified with the data from controlled (acceptable) and perturbed (unacceptable) runs. Then, each SVM is further utilized for the fault detection purpose utilizing control limits which is well understood in statistical process control chart. Utilizing SVMs, fault detection of reactive ion etching process is demonstrated with zero false alarm rate of the controlled runs on a run to run basis.

Isolation Control High Speed Transfer Switch for Upgrade Reliability of Uninterruptible Power Supply (USP의 신뢰성 향상을 위한 독립제어 고속절환장치)

  • Jung, Hyun-Chul;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.278-286
    • /
    • 2008
  • This paper investigates the fault generation type and the cause of output interruptionsin bulky with $30^{\sim}500[KVA]$ double conversion UPS, and proposes the fault detection method to improve the reliability of power supply used in the critical load in industry. Identifies its existing way of detecting a quality of inverter output it to bypass when exceeds its expectation. Under a UPS managing system, when an inner (Power device, Controller, CPU) fault occurs it disrupts the power supply and these occurrences has been verified by the results of experiments and application results. To overcome these problems, the proposed method constructs independently a fault-detection, a bypass-control device and a triple power supply apart from the conventional UPS operation. Also the detection point is changed to the preceding of a circuit breaker, a reference of fault detection is modified to avoid any clash and the breaking equipment is attached to intercept a spread of accident. As a result of applications of these developed systems to 242 UPS which was installed purposefully to the communication power supply, the service errors has not occurred in the UPS for two years since 2006.

On the Current Limiting Characteristics and Parameters of Superconducting Fault Current Limiter Introduced to 345kV Electric Power System due to Resistive-Type, Reactive-Type and Their Performance Comparison (유도형과 저항형 초전도한류기의 파라메타를 고려한 전력계통도입효과의 분석 및 성능평가에 관한 연구)

  • 홍원표;김용학
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.3
    • /
    • pp.74-83
    • /
    • 2002
  • The maximun short circuit current of modern power system is becoming so large that circuit breaker is not expected to be able to shut down the current in the future In order cut over-currents, a system composed of a superconducting fault current limiter(SFCL) and traditional breaker seems to provide a promising solution for furture power operation. In present paper, three line-to-ground fault is assumed to happen at the center of 345kV transmission lines in a large capacity electric power system. The superconducting fault current limiter was represented using a commutation type, which consists of a non-inductive superconducting coil and current limiting element (resistor or reactor). from the viewpoint of current limiting performance, the prevention of the voltage drop at the load bus and comparision characteristics for two type SFCL. Desired design specification and operation parameters of SECL were also given qualitatively by the performance.

DSP based Real-Time Fault Determination Methodology using Artificial Neural Network in Smart Grid Distribution System (스마트 그리드 배전계통에서 인공신경회로망을 이용한 DSP 기반 실시간 고장 판단 방법론 기초 연구)

  • Jin-Eun Kim;Yu-Rim Lee;Jung-Woo Choi;Byung-Hoon Roh;Yun-Seok Ko
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.5
    • /
    • pp.817-826
    • /
    • 2023
  • In this paper, a fault determination methodology based on an artificial neural network was proposed to protect the system from faults on the lines in the smart grid distribution system. In the proposed methodology, first, it was designed to determine whether there is a low impedance line fault (LIF) based on the magnitude of the current RMS value, and if it is determined to be a normal current, it was designed to determine whether a high impedance ground fault (HIF) is present using Normal/HIF classifier based on artificial neural network. Among repetitive DSP module-based algorithm verification tests, the normal/HIF classifier recognized the current waveform as normal and did not show reclosing operation for the cases of normal state current waveform simulation test where the RMS value was smaller than the minimum operating current value. On the other hand, for the cases of LIF where RMS value is greater than the minimum operating current value, the validity of the proposed methodology could be confirmed by immediately recognizing it as a fault state and showing reclosing operation according to the prescribed procedure.

On-line token control of fieldbus for effective data service (효과적 데이터처리를 위한 필드버스의 온라인 토큰제어)

  • 이석원;남부희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.680-683
    • /
    • 1997
  • Fieldbus system should be designed by considering the number of sensors/actors(actuators+ controllers) and their sampling times. But the number of sensors/actors and which are connected to the network bus can be varied by addition and/or fault of the field devices. That variation decreases the efficiency of system which is off-line designed optimally. This paper proposes an algorithm that ensures transmission of cyclic data even though there is the number change in the field devices. We assign the different weight values to cyclic data and acyclic data. By simulation and experiment, the cyclic and acyclic data are processed via the proposed network, and the results are compared with those of the Profibus system. It is shown that the proposed algorithm is more robust with the uncertainties of the field devices of the control system.

  • PDF

A Study on the HVDC Submarine Cable Fault Location Searching Case (HVDC 해저케이블 고장점 탐지 사례 연구)

  • Moon, Shin-Yong;Kim, Jeong-Dae;Jang, Seok-Han
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.138-140
    • /
    • 2006
  • 한국전력공사(이하 한전)에서는 제주지역 전력공급의 안정을 위해 '98년부터 국내 최초로 육지전력 계통과 연계하여 장거리 해저케이블 송전선로를 건설하여 운영하고 있다. 해저케이블은 해저에 포설되고 외부적 환경에 견디기 위해 육상케이블과 다른 많은 보호층을 포함하고 있어 설비의 유지보수에 많은 제약사항을 안고 있다. 특히 해남${\sim}$제주 연계선로는 기술적 장점 때문에 AC송전 대신 HVDC 송전을 하고 있어 한단계 Upgrade된 설비운영 기술이 필요하다. 본 고에서는 HVDC 해저 케이블의 설비운영에 있어 선로의 고장시 케이블의 고장점 위치를 탐지하는데 중점을 두어 실제 고장점 탐지 사례를 중심으로 HVDC 해저 케이블 고장점 탐지 방법 및 시험 결과를 검토하고 향후 유사 고장 발생에 효과적으로 대응하기 위한 절차를 제시하였다.

  • PDF

Observer-Based On-Line Overload Monitoring System of PMSM (상태관측기를 이용한 PMSM의 On-Line 과부하 모니터링 시스템)

  • Jang, Ki-Chan;Suh, Suhk-Hoon;Woo, Kwang-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.268-271
    • /
    • 2001
  • This paper presents observer-based on-line overload monitoring scheme for a PMSM(Permanent Magnet Synchronous Motor) drive system. Proposed scheme is to monitor overload status of motor drive system at remote place. The drive system is previously installed on main system and has no communication function. Proposed scheme consists of intelligent sensing head and monitoring part. Intelligent sensing head acquire motor 3-Phase currents and transmit data to monitoring part over serial communication interface. Monitoring part estimates motor speed using state observer. By comparing estimated speed with reference speed, we can detect motor fault. In this scheme observed information must coded and transmitted over a digital communication channel with finite capacity. We consider communication constraint as time delay and we design discrete-time observer. The proposed scheme is tested on the actual drive system.

  • PDF

A Protective Scheme for Wind Farm Interconnected to Distribution System (풍력발전단지가 연계된 배전계통에서의 보호방안)

  • Kim, Kyoung-Ho;Lee, Jong-Beom;Seo, Je-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.478-480
    • /
    • 2002
  • Wind energy can be conversed into electrical power using wind generator. Wind farm is made up of many wind generators, and it is often interconnected into distribution system to supply power for utilities. There are many protection problems on distribution system connected with Wind farm. It can effect on power quality severely when faults are occurred on distribution line or Wind farms. Therefore the correct protective scheme must be set for distribution system which has a Wind farm. In this paper, A wind farm connected into distribution line is simulated with several fault types which can be occurred on distribution line and Wind farm using PSCAD/EMTDC. And this paper proposes necessary relays to protect both sides of distribution system and wind farm.

  • PDF

A Study on a Distance Relaying Algorithm for Transmission Line Compensated with SSSC (SSSC로 보상된 송전 선로의 거리계전 알고리즘에 관한 연구)

  • Yang, J.W.;Nam, S.R.;Sohn, J.M.;Park, J.K.;Kang, Y.C.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1401-1403
    • /
    • 1999
  • This paper presents a distance relaying algorithm for transmission line compensated with Static Synchronous Series Compensator (SSSC). The compensation voltage driven by SSSC is calculated from the line current measured at a relaying point Then the compensation voltage is subtracted from the voltage measured by the relay. We can apply conventional distance relaying algorithm with this subtracted voltage to locate a fault. The results of case studies using EMTP (Electro-Magnetic Transient Program) show the proposed algorithm has higher precision.

  • PDF

Presentation of a Fault Detecting Method for Power Transmission Line using M-sequence

  • Nishiyama, E.;Kuwanmi, K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.86.2-86
    • /
    • 2001
  • The method of pinpointing the place of the abnormalities of a power transmission system analyzes the voltage and the current information from the both ends of a power [1-2]. Now, there are only current and a voltage measuring instrument every about 20km, and the present condition is specifying the breaking down point by viewing of a worker in it. In this research, a power line circuit is assumed to be a line type system, and M-sequence is impressed to the end, it receives at other ends, the crosscorrelation function of input and output is taken, an impulse response is calculated, and the method in comparison with the time of normal is proposed. By this technique ...

  • PDF