Coated Conductor를 사용한 무유도 팬케이크형 한류 코일의 통전 손실 특성 (Transport Loss Characteristic of the Bifilar Pancake Type Fault Current Limiting Coil using Coated Conductor)

  • 박동근;방주석;양성은;안민철;심기덕;윤용수;남관우;석복렬;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권3호
    • /
    • pp.21-25
    • /
    • 2007
  • Superconducting fault current limiter (SFCL) is attractive apparatus to reduce fault current in power grid. Since it is applied to the alternating current (AC) power line, the SFCL has losses in the normal operation. Recently, coated conductor (CC) is noticeable material employed for resistive bifilar winding type SFCL in many research groups. Bifilar structure is expected to have low AC loss by magnetic field offset as compared with the single tape structure in the same length. This paper reports about characteristic of bifilar pancake type coil for SFCL application in AC loss aspect. The bifilar coil is wound using CC with facing on HTS sides each other. Transport AC loss measurement and characteristic analysis of the bifilar coil using CC have been performed at 77K. The test results are compared with the Norris equations and the test results of non-inductively wound paralleled solenoid type coil which is suggested and tested in this group at present.

안강부근 양산단층 지역에서의 중력 및 지자기 연구 (Gravimetric and magnetic studies in an Yangsan fault area near Angang)

  • 김기영;이광자
    • 지구물리
    • /
    • 제1권1호
    • /
    • pp.31-40
    • /
    • 1998
  • 양산단층이 통과하는 안강 부근에서 기반암 분포, 지표 근처 단층과 파쇄대 위치 및 규모 등을 밝히기 위하여 중력과 총지자기를 측정하였다. 예상되는 단층의 주향과 거의 직각이 되는 2개 측선을 따라 총 67개 지점에서 15 m 간격으로 중력을 정밀하게 측정하였으며, 총지자기는 동일 측선을 따라 3 m 간격으로 총 296 점에서 측정하였다. 스펙트럼 분석법으로 구한 자기 기반암의 평균 깊이는 형산강을 중심으로 서부와 동부 측선에서 각각 8.5, 10.0 m로 계산되며, 중력 측정값은 형산강 동부가 서부보다 평균 1.71 mGal 이상 크게 나타나서 서부가 동부보다 파쇄 정도가 더욱 심한 것으로 해석된다. 중력 순산모델 연구는 동부 측선의 동쪽 끝에서 210 m 떨어진 지점에 놓인 단층을 경계로 서쪽으로 밀도 2.44 g/cm3, 깊이 70 m의 파쇄대가 발달되어 있으며, 395 m 지점을 중심으로 기반암 상부면이 폭 190 m, 평균 3.5 m 깊이의 소규모 비대칭 지구가 존재할 가능성을 제시한다. 또한 이 지구 위치의 지표 고도는 주위보다 약 44 cm 꺼져 있어서, 이 지구가 그리 오래되지 않은 시기의 단층운동에 의해 형성되었을 가능성이 높은 것으로 해석된다.

  • PDF

Design of Fault Diagnostic and Fault Tolerant System for Induction Motors with Redundant Controller Area Network

  • 홍원표;윤충섭;김동화
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.371-374
    • /
    • 2004
  • Induction motors are a critical component of many industrial processes and are frequently integrated in commercially available equipment. Safety, reliability, efficiency, and performance are some of the major concerns of induction motor applications. Preventive maintenance of induction motors has been a topic great interest to industry because of their wide range application of industry. Since the use of mechanical sensors, such as vibration probes, strain gauges, and accelerometers is often impractical, the motor current signature analysis (MACA) techniques have gained murk popularity as diagnostic tool. Fault tolerant control (FTC) strives to make the system stable and retain acceptable performance under the system faults. All present FTC method can be classified into two groups. The first group is based on fault detection and diagnostics (FDD). The second group is independent of FDD and includes methods such as integrity control, reliable stabilization and simultaneous stabilization. This paper presents the fundamental FDD-based FTC methods, which are capable of on-line detection and diagnose of the induction motors. Therefore, our group has developed the embedded distributed fault tolerant and fault diagnosis system for industrial motor. This paper presents its architecture. These mechanisms are based on two 32-bit DSPs and each TMS320F2407 DSP module is checking stator current, voltage, temperatures, vibration and speed of the motor. The DSPs share information from each sensor or DSP through DPRAM with hardware implemented semaphore. And it communicates the motor status through field bus (CAN, RS485). From the designed system, we get primitive sensors data for the case of normal condition and two abnormal conditions of 3 phase induction motor control system is implemented. This paper is the first step to drive multi-motors with serial communication which can satisfy the real time operation using CAN protocol.

  • PDF

변위벡터방향성을 이용한 터널 전방 단층대 예측에 관한 연구 (Prediction of a Fault Zone ahead of a Tunnel Face based on the Orientation of Displacement Vectors)

  • 김광염;임성빈;김장겸;서용석;김진웅
    • 지질공학
    • /
    • 제20권4호
    • /
    • pp.371-380
    • /
    • 2010
  • 본 연구에서는 3차원 유한요소해석을 통해 터널 굴착 전방에 위치한 단층대를 내공변위 계측결과를 이용하여 예측하기 위한 방안을 고찰하였다. 이를 위하여 터널과 단층대의 기하학적 위치변화에 따른 수치해석 모델을 구성하였다. 단층대의 경사는 각각 $90^{\circ}$, 터널 진행 반대방향 $45^{\circ}$, 터널 진행방향 $45^{\circ}$의 3가지로 구분하였으며, 각 경사별로 주향을 $15^{\circ}$ 간격으로 변화시켜 총 15개의 해석 모델에 대하여 분석하였다. 각 모델별 내공변위의 변화양상은 천단부와 측벽부에서의 벡터 방향성을 이용하여 분석하였다. 최종적으로, 총 9가지 조건의 단층대 분포 특성에 해당하는 굴착면 전방 예측 경향선을 도시화 하였으며, 이를 기반으로 일상 계측 데이터 분석을 통한 전방 단층대 출현 및 배향의 예측 방안을 제시하였다.

$Au/YBa_2Cu3O_7$ 곡선에 인가가능 전압 (Voltage Applicable to $Au/YBa_2Cu3O_7$ Meander Lines)

  • 김혜림;임성우;유승덕;박충렬;양성은;김우석;현옥배
    • Progress in Superconductivity
    • /
    • 제12권1호
    • /
    • pp.62-67
    • /
    • 2010
  • We investigated the voltage applicable to $Au/YBa_2Cu3O_7$ (YBCO) meander lines. The meander line was fabricated by patterning Au/YBCO thin films grown on sapphire substrates by photolithography. It was subjected to simulated AC fault currents, and the resistance was measured and analyzed. The samples were immersed in liquid nitrogen during the experiment for effective cooling. The voltage applicable to the meander lines depended on the fault duration. Dependence was strong at short fault durations, and weak at long durations. When the voltage was plotted as a function of the fault duration on a log-log scale, data fell more or less on straight lines for all meander lines. In other words, the voltage applicable to Au/YBCO meander lines on sapphire substrates was inversely proportional to $t^b$, where t is the fault duration and b ranges from 0.4 to 0.5. The results were analyzed quantitatively with the concept of heat balance. Under adiabatic condition, the voltage is to be inversely proportional to $t^{0.5}$ for all samples. Less value of b for some samples is thought to be due to cooling of the samples by liquid nitrogen.

천단변위의 x-Rs 관리도 분석을 이용한 터널 막장 전방 단층대 예측 (Prediction of fault zone ahead of tunnel face using x-Rs control chart analysis for crown settlement)

  • 윤현석;서용석;김광염
    • 한국터널지하공간학회 논문집
    • /
    • 제16권4호
    • /
    • pp.361-372
    • /
    • 2014
  • 터널 변위 계측은 전방의 단층대의 예측과 안정성 해석에서 매우 중요하다. 본 연구에서는 3차원 유한요소해석을 통해 터널 단층대의 방향과 존재에 따른 터널의 거동 특성을 평가하였다. 터널의 거동을 대표하는 계측치인 천단변위를 막장면에서 5 m 떨어진 지점에서 평가하였으며, 경향선과 L/C비 (종방향변위/천단변위)를 계산하여 통계적 관리기법인 x-Rs를 적용하여 단층대의 예측방안을 제시하였다. 결과적으로, x-Rs 관리도 기법이 전방 단층대의 존재와 방향을 예측하는데 활용될 수 있음을 확인하였다.

굴절파 GRM 해석방법을 응용한 고경사 단층 인지 (Ⅱ) -실제 자료 적용- (Identification of high-dip faults utilizing the GRM technique of seismic refraction method(Ⅱ) -Application to real data-)

  • 김기영;우남철
    • 지구물리
    • /
    • 제2권1호
    • /
    • pp.65-74
    • /
    • 1999
  • 양산단층이 통과하는 언양 부근에서 기록한 굴절파 4개 측선자료를 대상으로 구배변화 지시자를 구하고 단층 분포상태를 해석하였다. XY=3 m인 속도분석 함수를 이용하여 구한 대상 굴절면의 평균속도는 2,250-2,870 m/s 정도이며, 가장 서쪽에 위치한 측선 1은 다른 측선보다 굴절파 속도가 약 600 m/s 정도 작게 나타난다. XY값이 6 m와 0 m인 속도분석 함수의 차이를 이용하여 구한 구배변화 지시자의 진폭이 0.5 ms/m 이상인 곳은 고해상도 반사파 단면상에 해석된 단층위치와 대체로 일치하며, 전반적으로 한 개의 측점간격(3 m) 정도 벗어난 양상을 보인다. 진폭이 큰 구배변화 지시자는 35번 국도를 중심으로 밀집되어 나타나며, 가장 큰 단층은 지질도상의 예상단층선에서 약 930 m 서쪽에 위치하는 것으로 해석된다.

  • PDF

수배전계통의 여러 가지 고장조건에서 피뢰기에 흐르는 누설전류 (Leakage Currents Flowing through Lightning Surge Arresters under Various Fault Conditions in Receiving and Distribution Power Systems)

  • 이복희;길형준;강성만;최휘성
    • 조명전기설비학회논문지
    • /
    • 제18권5호
    • /
    • pp.132-139
    • /
    • 2004
  • 수배전계통의 고장에는 1선 지락, 선간 단락, 2선 지락 등의 고장이 있다. 가공 배전 계통에서 일어나는 대부분의 고장은 1선 지락이며, 피뢰기는 이러한 고장에 의한 빈번한 과전압에 의해 스트레스를 받는다. 본 논문에서는 수배전계통에서 일어날 수 있는 고장을 모의하여 여러 가지 고장에 의해 피뢰기에 흐르는 누설전류의 특성에 대하여 조사하였다. 결과적으로, $\pm$10[%] 범위의 전압변동률에 의해서 피뢰기에 흐르는 누설전류는 거의 변화가 없었다. 성능이 우수한 접지 시스템 하에서는 전압변동률은 피뢰기의 긴 시간동안의 동작에 별 영향을 줄 수가 없었다. 하지만, 1선 지락 고장에서 피뢰기에 흐르는 누설전류의 최대값은 비효과적인 접지 시스템의 운전 전압에서의 누설전류와 비교하였을 때 140배 이상이 되었다. 그러나 선간 단락과 2선 지락 고장의 경우에는 피뢰기의 누설전류에 거의 영향을 미치지 못했다.

Development of On-line Performance Diagnostic Program of a Helicopter Turboshaft Engine

  • Kong, Chang-Duk;Koo, Young-Ju;Kho, Seong-Hee;Ryu, Hye-Ok
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제10권2호
    • /
    • pp.34-42
    • /
    • 2009
  • Gas turbine performance diagnostics is a method for detecting, isolating and quantifying faults in gas turbine gas path components. On-line precise fault diagnosis can promote greatly reliability and availability of gas turbine in real time operation. This work proposes a GUI-type on-line diagnostic program using SIMULINK and Fuzzy-Neuro algorithms for a helicopter turboshaft engine. During development of the diagnostic program, a look-up table type base performance module are used for reducing computer calculating time and a signal generation module for simulating real time performance data. This program is composed of the on-line condition monitoring program to monitor on-line measuring performance condition, the fuzzy inference system to isolate the faults from measuring data and the neural network to quantify the isolated faults. Evaluation of the proposed on-line diagnostic program is performed through application to the helicopter engine health monitoring.

154kV 송전선로 피뢰기 설치용 아킹혼 개발 (Development of Arc-horn to be mounted on 154kV Transmission Line Arrester)

  • 민병욱;김우겸;이북창;최한열;박재웅;금의연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.335-336
    • /
    • 2008
  • Overhead transmission lines are mainly crossing mountainous area. They are easily affected in weathers like typhoon, strong wind, lightning, heavy rain, or heavy snow. Sometimes these weathers cause transmission line faults. A lightning flashover is most often fault. Nowadays lightning density in KOREA is growing high and lightning flashovers occur more often. A lightning flashover on transmission line is mostly cleared by momentary operation of a circuit breaker, so power failure happens rarely. However, when both circuits trip simultaneously due to the lightning flashovers on double circuit transmission line, short time power failure and voltage drop happen. KEPCO has used transmission line arresters to avoid double circuit simultaneous trip out since 2003. And transmission line arresters cannot be installed with KEPCO's present metal fittings, so various fittings have been used for each transmission line arrester manufacturer. This paper introduces development and standardization of arc-horn and metal fittings for transmission line arrester which can be used for both existing lines and new lines in KEPCO.