• 제목/요약/키워드: Fault line

검색결과 1,139건 처리시간 0.032초

Analysis on How to Locate the Maximum Line Voltage to Hull in Steady State on the Vector Diagram Onboard Vessels

  • Choi, Soon-Man
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권7호
    • /
    • pp.966-973
    • /
    • 2011
  • Power distribution onboard vessel is typically configured as ungrounded system due to the ability to continuously supply electric power even when an earth fault occurs. The impedance connections between 3 phase power lines and hull cause the line-to-hull voltages to become unstable and increased in case the impedances are unbalanced, bringing the situation susceptible to electric shock and deterioration of insulation material. Also the line-to-hull voltage can reach to a certain maximum value in the steady state depending on the distributed capacitances and grounding resistances between lines and hull. This study suggests how to find and calculate the maximum line-to-hull voltage in view of magnitude and phase angle based on the vector diagram.

경계스캔 구조를 사용한 시스템의 온라인 버스 모니터링 (On-line Bus Monitoring of a System Using Bondary-Scan)

  • 송동섭;배상민;강성호;박영호
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제49권12호
    • /
    • pp.675-682
    • /
    • 2000
  • When a system is composed of multi-boards, an efficient bus arbitration method for the data transfer bus must be provided for guaranteeing proper operations. In this paper, a new test methodology is developed which is used for testing on-line bus arbitration. In the new test methodology, events that are occurred during bus arbitration are defined, and expected signals during fault-free bus arbitration are compared with the signals captured during on-line bus arbitration using boundary-scan cells. For this, a new test architecture is proposed which is efficient for the maintenance and the repair of multi-board systems. In addition, the new methodology can be used with off-line interconnect test using boundary-scan.

  • PDF

배전계통 선로상태 파악을 위한 전문가 시스템 (Expert System for Line State Recognition of Distribution System)

  • 김윤동;최병윤;문영현;송경빈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.111-114
    • /
    • 1988
  • With the increase of size and complicacy of power systems, distribution system need to operate effectively for high reliability. In order to achieve this purpose, the study which apply expert system to operating plan, restoration on fault and distribution system operating, has developing actively. The essential element of the study is system line state which make a system observe. The development of expert system on power system operation make a system be able to judge state of loading and looping system line, related current direction, substation, and distribution line, atomatically by breaker operation. Finally, this paper developed expert system which decides itself atomatically by rules for deciding system line state.

  • PDF

카메라 백 카버 생산 조립 라인의 자동화 시스템 개발 (Development of Automation System of Assembly Line On the Back Cover of a Camera)

  • 이만형
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2000년도 춘계학술대회논문집 - 한국공작기계학회
    • /
    • pp.153-158
    • /
    • 2000
  • This paper addresses an intelligent robot control system using an off-line programming to teach a precise assembly task of electronic components in a flexible way. The investigated task consists of three job: heat caulking test, soldering on a circuit board, and checking of soldering defects on the back cover of a camera. This study investigates the remodelling of the most complicated cell in terms of the accuracy and fault rate among the twelve cells in a camera back-cover assembly line. We have attempted to enhance back-cover assembly line. We have attempted to enhance soldering quality, to add task flexibility, to reduce failure rate, and to increase product reliability. This study modifies the cell structure, and improves the soldering condition. The developed all system implements the real-time control of assembly with vision data, and realized an easier task teaching on off-line programming.

  • PDF

TDX-1A 가입자 선로 시험 (Aspects of Subscriber Line Test in TDX-1A Digital Switching System)

  • 윤찬호;이윤복;이재섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(II)
    • /
    • pp.986-989
    • /
    • 1987
  • This paper describes the basic design concepts and architecture of the subscriber line test feature for the TDX-1A digital switching system. Also, implemented software structure for maintaining the multiprocessor control system employed in TDX-1A, which includes terminal server, MML, test, fault recognition and test result handling.

  • PDF

22.9KVY 배전방식에 관한 연구 (A Study on the 22.9KVY Multiground Distribution System)

  • 변승봉
    • 전기의세계
    • /
    • 제22권6호
    • /
    • pp.8-18
    • /
    • 1973
  • This paper is a part from the series study on the 22.9KVY multiground destribution system and its is divided into three parts as follow. A.C. Network Analyzer study on the load current flow when one phase line of the feeder is out of seroice because of cutting. A.C. Network Analyzer study on the increasing zero sequence current in the good feeders when one feeder is under fault of single phase short. Field test report of the common use of open telephone line on same poles of 22.9KVY distribution system.

  • PDF

배전계통에서의 최적 부하절체를 위한 전문가 시스템 (An Expert System for Optimal Load Transfer in Distribution Systems)

  • 문영현;최병윤;김세호
    • 대한전기학회논문지
    • /
    • 제39권9호
    • /
    • pp.903-911
    • /
    • 1990
  • When load areas on a feeder are deenergized due to faults and scheduled outage, operators need to identify neighboring feeders, try to restore customers and minimize out-of-service areas. These cases include knowledge of system states and various constraints such as voltage drop. This paper concerns the load transfer in fault restoration and scheduled outage. Also, the operating constraints such as line current capacity, relay trip current, transformer capacity, voltage drop and line loss are considered. This expert system can propose the optimal load transfer method by analyzing the system state and considering the constraints.

  • PDF

EMS 운용을 위한 상정사고 선정 (Contingency Selection For EMS Operation)

  • 김정년;백영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.175-178
    • /
    • 1996
  • Power system is becomming more and more complex and large. So system is stressed increasingly. This paper presents a method to select contingency ranking in power systems for EMS operation. Firstly, the proposed method is applied line outage using Thevenin equivalent circuit. Secondly, Contingency harmful to system is selected by loss variation between base case and fault. Thirdly, this paper prescribed simulated line sequence. Therefore this algorithm shows higher computation speed and effective memory use.

  • PDF

Fault Detection in the Two-for-One Twister

  • Park, Ho-Cheol;Koo, Doe-Gyoon;Lee, Jie-Tae;Cho, Hyun-Ju;Han, Young-A;Sohn, Sung-Ok;Ji, Byung-Chul
    • International Journal of Control, Automation, and Systems
    • /
    • 제4권6호
    • /
    • pp.763-768
    • /
    • 2006
  • The two-for-one(TFO) twister is precision machinery that twists fibers rapidly under constant tension. Since the quality of the twisted yarn is directly deteriorated by faults of the twister, such as the distortion of the spinning axis, bearing abrasion, and tension irregularity, it is important to detect faults of the TFO twister at an early stage. In this research, a new algorithm is proposed to detect faults of the TFO twister and their causes, by measuring the vibrations of the TFO twister and obtaining frequency components with a FFT algorithm. The TFO twister with faults showed increased vibrations and each fault generated vibrations at different frequencies. By analyzing changes of characteristics of vibrations, we can determine faulty twisters. The proposed fault detection algorithm can be implemented cheaply with a signal processor chip. It can be used to find when to repair a faulty TFO twister without much loss of yam on-line.

유도형과 저항형 초전도한류기의 파라메타를 고려한 전력계통도입효과의 분석 및 고찰 (On the Current Limiting Characteristics and Parameters of Superconducting Fault Current Limiter Introduced to 345kV Electric Power System due to Resistive-Type, Reactive-Type)

  • 홍원표;김용학;전영환;이승학
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.285-290
    • /
    • 2002
  • Power systems are becoming larger and larger for meeting electric power demand. Therefore, the over-currents resulting from contingencies such short circuits are increasing higher. The Maximum short circuit current of modern power system is becoming so large that circuit breaker are not expected th be able to shut down the current in the future. In order to cut over-currents, a system composed of a superconducting fault current limiter(SFCL) and traditional breaker seems to provide a promising solution for future power operation. In present paper, three line-to-ground fault is assumed to happen at the center of 345kV transmission lines in a large capacity electric power system The superconducting fault current limiter was represented using a commutation type, which consists of a non-inductive superconducting coil and current limiting element(resistor or reactor). The introduction merits of the SFCL were investigated quantitatively by RTDS/EMTDC from the viewpoint of current limiting performance, the prevention of the voltage drop at the load bus and comparison characteristics for two type SFCL. Desired design specification and operation parameters of SFCL were also given qualitatively by the performance evaluation of the two type SFCL in the power system.

  • PDF