• Title/Summary/Keyword: Fault line

Search Result 1,139, Processing Time 0.033 seconds

Analysis on Fault-Related Landformsin the Gyeongju Area of the Yangsan Fault Valley (양산 단층곡 경주 지역의 단층 지형 분석)

  • Park, Chung-Sun;Lee, Gwang-Ryul
    • Journal of The Geomorphological Association of Korea
    • /
    • v.25 no.1
    • /
    • pp.19-30
    • /
    • 2018
  • This study tries to infer fault lines and produce a map for the lines based on a classification of fault-related landforms and fluvial landformsin the Gyeongju area of the Yangsan Fault Valley. Fault activities in the study area are thought to be older than the time of river formation or stronger than the erosion by river, while the northern and southern parts of the study area seem to have experienced fault activities after valley formation. It is also possible that weaker fault activities than the erosion by river seem to have been prevailed in the parts. In the study area, the Gyeongju alluvial fan is located within a wide erosional valley at the joint area of the Yangsan and Ulsan Faults. From the distribution of the landforms, it is inferred that several fault lines parallel to the Yangsan Fault are distributed at both sides of the fault valley. In particular, the area from Bae-dong to Nogok-ri, Naenam-myeon shows the most obvious linearity of the landforms within the study area. Several fault lines with a direction of NNE-SSW are also found around the epicenter of the 2016 Gyeongju Earthquake.

Analysis of Progression of Transmission Line Fault by Fault Recorder Oscillograph (Fault Recorder 파형 분석을 통한 송전선로 고장 진전상황 분석)

  • Shim, Eung-Bo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.525-526
    • /
    • 2011
  • 전력계통에서 발생하는 고장 중에는 고장 후의 결과만을 가지고는 어떻게 고장이 초기에 발생하여 진전되었는지를 추정하기가 어려운 고장이 간혹 발생한다. 본 고장 분석사례는 보호계전기의 동작사항과 고장기록장치의 파형을 이용하여 송전선로에서 고저항 지락에 의한 최초의 고장이 발생 할 수 있는 가능성과, 그 고장으로 인한 파급 고장 사례를 예시하였다. 과도현상 분석 프로그램인 EMTP (Electro-Magnetic Transient Program)를 이용하여 고장 사례를 재현하여 Fault Recorder 기록과의 유사성을 확인하였다.

  • PDF

Bi-directional fault analysis of evaporator inspection system

  • Kang, Dae-Ki;Kang, Jeong-Jin
    • International journal of advanced smart convergence
    • /
    • v.1 no.1
    • /
    • pp.57-60
    • /
    • 2012
  • In this paper, we have performed a safety analysis on an automotive evaporator inspection system. We performed the bi-directional analysis on the manufacturing line. Software Fault Tree Analysis (SFTA) as backward analysis and Software Failure Modes, Effects, & Criticality Analysis (SFMECA) as forward analysis are performed alternately to detect potential cause-to-effect relations. The analysis results indicate the possibility of searching and summarizing fault patterns for future reusability.

An Investigation of the nominal rating current for breakers in distribution system due to the increased capacity of power transformer (주변압기 용량증설에 따른 배전계통의 차단기 정격차단전류 검토)

  • Cho, Seong-Soo;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.396-397
    • /
    • 2008
  • In order to evaluate the nominal rating of breakers in distribution system due to the increased capacity of power transformer from 60 to 100 MVA, the fault currents are calculated in the condition of 3-phase fault and single line-to-ground fault. Consequently, under the condition of the parallel operation of transformers the fault currents were exceed the nominal rating current of breakers in some areas.

  • PDF

Fault Location Estimation Algorithm in the Railway High Voltage Distribution Lines Using Flow Technique (반복계산법을 이용한 철도고압배전계통의 고장점표정 알고리즘)

  • Park, Kye-In;Chang, Sang-Hoon;Choi, Chang-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.71-79
    • /
    • 2008
  • High voltage distribution lines in the electric railway system placed according track with communication lines and signal equipments. Case of the over head lines is occurrence the many fault because lightning, rainstorm, damage from the sea wind and so on. According this fault caused protection device to wrong operation. One line ground fault that occurs most frequently in railway high voltage distribution lines and sort of faults is line short, three line ground breaking of a wire, and so on. For this reason we need precise maintenance for prevent of the faults. The most important is early detection and fast restoration in time of fault for a safety transit. In order to develop an advanced fault location device for 22.9[kV] distribution power network in electric railway system this paper deals with new fault locating algorithm using flow technique which enable to determine the location of the fault accurately. To demonstrate its superiorities, the case studies with the algorithm and the fault analysis using PSCAD/EMTDC (Power System Computer Aided Design/Electro Magnetic Transients DC Analysis Program) were carried out with the models of direct-grounded 22.9[kV] distribution network which is supposed to be the grounding method for electric railway system in Korea.

Fault Management in Crossbar ATM Switches (크로스바 ATM 스위치에서의 장애 관리)

  • Oh Minseok
    • The KIPS Transactions:PartC
    • /
    • v.12C no.1 s.97
    • /
    • pp.83-96
    • /
    • 2005
  • The multichannel switch is an architecture widely used for ATM (Asynchronous Transfer Mode). It is known that the fault tolerant characteristic can be incorporated into the multichannel crossbar switching fabric. For example, if a link belonging to a multichannel group fails, the remaining links can assume responsibility for some of the traffic on the failed link. On the other hand, if a fault occurs in a switching element, it can lead to erroneous routing and sequencing in the multichannel switch. We investigate several fault localization algorithm in multichannel crossbar ATM switches with a view to early fault recovery. The optimal algorithm gives the best performance in terms of time to localization but it is computationally complex which makes it difficult to implement. We develop an on-line algorithm which is computationally more efficient than the optimal one. We evaluate its performance through simulation. The simulation results show that the Performance of the on-line algorithm is only slightly sub-optimal for both random and bursty traffic. There are cases where the proposed on-line algorithm cannot pinpoint down to a single fault. We enumerate those cases and investigate the causes. Finally, a fault recovery algorithm is described which utilizes the information provided by the fault localization algorithm The fault recovery algorithm providesadditionalrowsandcolumnstoallowcellstodetourthefaultyelement.

Structural, Paleomagnetic and Petrological Studies of the Chugaryeong Rift Valley (추가령(標哥嶺) 지구대(地構帶)의 지질구조(地質構造), 고지자기(古地磁氣) 및 암석학적(岩石學的) 연구(硏究))

  • Kim, Kyu Han;Kim, Ok Joon;Min, Kyung Duck;Lee, Youn Soo
    • Economic and Environmental Geology
    • /
    • v.17 no.3
    • /
    • pp.215-230
    • /
    • 1984
  • Petrological, paleomagnetic, geomorphological and structural studies on the southern part of, so called, Chugaryeong rift valley, have been carried out in order to clarify the nature of the rift valley. Three stages of volcanic activities characterized by Jijangbong acidic volcanic rocks and tholeiitic and andesitic basalt of Cretaceous age(?), and Jongok Quaternary olivine basalt occurred along the Dongducheon fault line. Jijangbong acidic volcanic rocks distributed in the central part of the studied area consist of rhyodacite, acidic tuff and tuff breccia, which are bounded by Dongsong fault on the east and Daegwangri fault on the west. The Jongok basalt differs from those of Ulrung and Jeju islands in mineralogy, chemical composition and differentiation. Jongok basalt distributed along the Hantan river dilineates the vesicles curved toward downstream direction and increment of numbers and thickness of lava flow toward upstream direction. These facts suggest that lava flowed from upstream side of the river. Rectangular drainage patterns also support the presence of the Dongducheon, Pocheon, Wangsukcheon and Kyonggang faults which were previously known. LANDSAT image, however, does not show any lineaments which could be counted as a graben or rift valley. Displacement of Precambrian quartzite and Jurassic Daedong supergroup along the southwestern extension of the Dongducheon fault shows the right lateral movement. The Paleomagnetic study of the tholeiitic and andesitic basalts from Baegeuri, Jangtanri and Tonghyeonri located at 2. 3km east, 0km east, and 1.5km west of Dongducheon fault respectively shows that their VGP(Virtual Geomagnetic Pole) being to intermediate geomagnetic field of short duration which suggests that they formed in almost same period. Mean VGP of Jongok basalt is located 82.4N and 80.6E. This is in good coincidence with worldwide VGP of Plio-Pleistocene indicating that Jongok basalt was extruded during Plio-Pleistocene epoch, and suggesting that the studied area has been tectonically stable since then. From the present study, the tectonic episode of the region is concluded as following three stages. 1. The 1st period is worked by the Daebo orogeny of Jurassic during which granodiorite was intruded in Precambrian basement. 2. The 2nd period is the time when right lateral strike-slip fault of NNE-SSW direction was formed probably during late Cretaceous to Paleogene and the Jijangbong acidic volcanic rocks and the older basalts were extruded. 3. The 3rd period is the time when the fault was rejuvenated during Pliocene or Pleistocene accompanied by the eruption of Jongok basalt. As a conclusion, geologic structure of the studied area is rather fault line valley than graben or rift valley, which is formed by differential erosion along the Dongducheon fault suggesting a continuation of the Sikhote-Alin fault. The volcanic rocks including the Jijangbong acidic rocks, tholeiitic-andesitic basalt and olivine basalt are associated with this fault line.

  • PDF

A Study on Reclosing Decision on 154kV Combined Transmission Lines (154kV 혼합송전선로 재폐로 결정에 관한 연구)

  • Jung, Chae-Kyun;Park, Hung-Sok;Kang, Ji-Won;Lee, Jong-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1761-1769
    • /
    • 2010
  • This paper describes switching surge analysis on reclosing decision in 154kV combined transmission line with power cables. Reclosing should be operated in combined transmission line based on the technical evaluation because of insulation problem of power cable section. If the surge strikes on power cable, the breakdown can occur at week point of cable insulation. Therefore the detailed analysis is required by considering several conditions such as length ratio of power cable, arrester, fault resistance, charging rate and grounding resistance, etc.. In addition, sheath voltage on IJ(Insulated Joint) is analyzed to confirm the protective level. Simulation is performed by EMTP/ATP. Analysis results show that reclosing can be operated without any special problem by the single line-to-ground fault with fault resistance of $1\Omega$ to $50\Omega$ occurred at the overhead transmission section in 154kV combined transmission lines and trap charge of 100% and 110%.

Development and application of on-line lightning information service (온라인(On-line) 낙뢰정보 활용 서비스의 개발과 활용)

  • Kwak, J.S.;Woo, J.W.;Kang, Y.W.;Koo, G.S.;Choi, H.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.696-698
    • /
    • 2007
  • As overhead transmission lines are exposed to the outdoor weather, lightning induced fault accounts for about 66% of faults in transmission lines. The lightning may cause the damage of power system apparatus or the shut down of electricity. Not only in order to decrease the damage of the power system itself but also to ensure the reliable power supply, an appropriate insulation design based on the long-term lightning statistics is required. Meanwhile, real time information of lightning might be more useful to quickly locate the point of lightning induced fault in the line, leading to minimization of the adverse effects derived from the fault. Korea Electric Power Corporation has been providing an on-line lightning information service, named as KLDNet, since 2006 in order to meet the need inside our company. This paper describes the development and application of the information system.

  • PDF

A Study on Possibility of Detection of Insulators' Faults by Analyses of Radiation Noises from Insulators (애자의 소음 분석을 통한 애자 고장 탐지 가능성 연구)

  • Park, Kyu-Chil;Yoon, Jong-Rak;Lee, Jae-Hun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.8
    • /
    • pp.822-831
    • /
    • 2009
  • The porcelain insulators are important devices, that are used to isolate electrically and hold mechanically in the high-voltage power transmission systems. The faults of the insulators induce very serious problems to the power transmission line. In this paper, we introduce techniques for fault detections of insulators by acoustic radiation noises from them. We measured radiation noises from normal state insulators and fault state insulators. The used insulators were two different type porcelain insulators, a cut out switch, two different type line posters, and a lightning arrester. Each results was compared each other in time domain, frequency domain and filter banks' outputs. We found the possibility of detection of insulators' faults and also suggested techniques for fault detections.