Analysis of Fault Current Limiting Characteristics According to Variation of Inductances in Separated Three-phase Flux-lock Type SFCL (분리된 삼상자속구속형 전류제한기의 인덕턴스 변화에 따른 전류제한 특성 분석)

  • Doo, Seung-Gyu;Du, Ho-Ik;Kim, Min-Ju;Park, Chung-Ryul;Kim, Yong-Jin;Lee, Dong-Hyeok;Han, Byoung-Sung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.6
    • /
    • pp.522-525
    • /
    • 2009
  • We investigated the fault current characteristics of the separates three-phase flux-lock type superconducting fault current limiter(SFCL) according to the variation of inductances. The single-phase flux-lock type SFCL consists of two coils. The primary coil is wound in parallel to the secondary coil on an iron core. And superconductor is series connected on secondary coil. Superconductor is using the YBCO coated conductor. The separated three-phase flux-lock type SFCL consists of single-phase flux-phase type SFCL in each phase. To analyze the current limiting characteristics of a three-phase flux-lock type SFCL, the short circuit experiments were carried out fault such as the triple line-to-ground fault. The experimental result shows that fault current limiting characteristics of additive polarity winding was better than subtractive polarity winding and when the inductances of coil 2 was lower, resistances of YBCO CC was more generated.

Improvement of Digital Distance Relaying Algorithm Using Wavelet Transform in Combined Transmission Line (웨이브렛을 이용한 혼합송전선로에서의 거리계전 알고리즘 개선)

  • 정채균;김경호;하체웅;이종범;윤양웅
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.10
    • /
    • pp.593-601
    • /
    • 2003
  • Distance realy is tripped by the line impedance calculated at the relay point. Accordingly the accurate operation depends on the precise calculation of line impedance. Impedance can be accurately calculated in case of overhead line. However, in case of power cables or combined transmission lines, impedance can not be accurately calculated because cable systems have the sheath, grounding resistance, and sheath voltage limiters(SVLs). There are also several grounding systems in cable systems. Therefore, if there is a fault in cable systems, these terms will severely be caused much error to calculation of impedance. Accordingly the proper compensation should be developed for the correct operation of the distance relay. This paper presents the distance calculating algorithm in combined transmission line with power cable using wavelet transform. In order to achieve such purpose, judgement method to discriminate the fault section in both sections was proposed using D1 coefficient summation in db4. And also, error compensation value was proposed for correct calculation of impedance in power cables section.

Reactivated Timings of Yangsan Fault in the Northern Pohang Area, Korea (포항 북부지역 양산단층의 재활동 연대)

  • Sim, Ho;Song, Yungoo;Son, Moon;Park, Changyun;Choi, Woohyun;Khulganakhuu, Chuluunbaatar
    • Economic and Environmental Geology
    • /
    • v.50 no.2
    • /
    • pp.97-104
    • /
    • 2017
  • Here we present the timings of reactivated events from a fault in the northern Pohang area, which should be located at the northern-end of Yangsan fault line, the major fault in the southeastern Korean Peninsula. Recently developed illite-age-analysis (IAA) approach was employed for determining the fault-activated timing, combined with illite-polytype quantification using the optimized full-pattern-fitting (FPF) method, and K-Ar age-dating for each size fraction($<0.1{\mu}m$, $0.1-0.4{\mu}m$, and $0.4-1.0{\mu}m$) of 4 fault clay samples. Two chronological records of brittle fault-activation events were recognized at $19.6{\pm}1.86Ma$ and $26.1{\pm}2.55-27.9{\pm}3.46Ma$. The ages are much younger than those of fault clays from Sangcheon-ri area (41.5~43.5 and 50.7 Ma), the southern part of Yangsan fault line, and are close to the timing of East Sea-opening event. Further chronological analysis for additional sites of the Yangsan fault should be needed to reveal the time-scheme of the tectonic events and their spatial distributions along the fault line.

Analysis of Current Limiting Characteristics According to Fault Angles in Integrated Three-Phase Flux-Lock Type Superconducting Fault Current Limiting (일체화된 삼상 자속구속형 고온초전도 전류제한기의 사고각에 따른 전류제한 특성 분석)

  • Park, Chung-Ryul;Du, Ho-Ik;Yim, Seong-Woo;Hyun, Ok-Bae;Lim, Sung-Hun;Park, Hyoung-Min;Cho, Yong-Sun;Nam, Gueng-Hyun;Lee, Na-Young;Choi, Hyo-Sang;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.255-256
    • /
    • 2006
  • In this paper, we investigated the. characteristics of fault current limiting according to fault angle in the integrated three-phase flux-lock type SFCL in fault types such as the single-line-to-ground fault, the double-line-to-ground fault and the three-line-to-ground fault. When the SFCL is operating under normal condition, the magnetic flux generated between primary and secondary coils of each single phase is canceled out perfectly, so that the impedance of the SFCL is also not generated and the power system can be operated normally without any loss, However, if a fault occurs even in any phase out of three phases, quench happened in SFCL elements and the current flowing secondary coil is restricted abruptly. Finally, the balance of magnetic flux in whole SFCL system is destroyed, and the fault currents in every phase could be limited at the same time irrespective of the fault types. As a result, the developed SFCL in this study were operated normally as expected and the purpose of the integration of 3 phase current limiting was also achieved successfully. However, the fault current limiting characteristics of the SFCL was dependant on the quench characteristics of HTSC elements in each phase, and it was expected that the improvement of the SFCL could be possible through the introduction of HTSC elements which have better critical characteristics.

  • PDF

Fault Location Estimation for High Impedance Fault using Wavelet Transform (Wavelet 변환을 이용한 고저항 지락사고 고장점 추정)

  • Kim, Hyun;Kim, Chul-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.8
    • /
    • pp.369-373
    • /
    • 2000
  • High impedance fault(HIF) is defined as a fault that the general overcurrent relay can not detect or interrupt. Especially when HIF occurs in residential areas, energized high voltage conductor results in fire hazard, equipment damage or personal threat. This paper proposes a fault location estimation algorithm for high impedance fault using wavelet transform. The algorithm is based on the wavelet analysis of the fault voltage and current signals. The performance of the proposed algorithm is tested on a typical 154kV korean transmission line system under various fault conditions. From the tests presented in this paper it can be concluded that a fault location estimation algorithm using wavelet transform can precisely calculate the fault point for HIF.

  • PDF

A Process Decomposition Strategy for Qualitative Fault Diagnosis of Large-scale Processes (대형공정의 정성적 이상진단을 위한 공정분할전략)

  • Lee Gibaek
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.4 s.12
    • /
    • pp.42-49
    • /
    • 2000
  • Due to their size and complexity, it is very difficult to make diagnostic system for the whole chemical processes. Therefore, a systematic approach is required to decompose larpge-scale process into sub-processes and then diagnose them. This paper suggests a method for the minimization of knowledge base and flexible diagnosis to be used in qualitative fault diagnosis based on Fault-Effect Tree model. The system can be decomposed for flexible diagnosis, size reduction of knowledge base, and consistent construction of complex knowledge base. The new node, gate-variable, is introduced to connect the cause-effect relationships of each sub-process. For on-line diagnosis, off-line analysis is performed to construct Fault-Effect Trees of gate-variables as well as activation conditions of gate-variables. On-line diagnosis strategy is modified to get the same diagnosis result without system decomposition. The proposed method is illustrated with a fault diagnosis system for a large-scale boiler plant.

  • PDF

Control of Grid Connected Type PCS to Minimize Voltage Disturbance at Line Fault (계통 사고 발생시 전압 변동을 최소화 하기위한 계통연계형 PCS의 제어 기법)

  • Jung, Jae-Hun;Kwon, Chang-Keun;Nho, Eui-Cheol;Kim, In-Dong;Kim, Heung-Geun;Chun, Tae-Won
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.257-258
    • /
    • 2011
  • This paper describes a new method for the seamless operation mode transfer of a PCS with minimized voltage disturbance. The proposed method provides reduced STS turn off time after line fault and smooth mode change between current and voltage control of the PCS. The usefulness of the method is verified through simulations with the consideration of the time delay in detecting a line fault and SCR turn-off time.

  • PDF

Electromagnetic Behavior of High-Tc Superconducting Fault Current Limiters under the Quench State (켄치 상태에서 고온 초전도 한류기의 전자기적 거동)

  • Hyo-Sang Choi
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.1
    • /
    • pp.38-42
    • /
    • 2004
  • In this paper we analyzed the electromagnetic behavior of a superconducting fault current limiter (SFCL) under the quench state using FEM. The analysis model used in this work is 5.5 KVA meander-line type SFCLs which are currently developed by Superconductor Power System Lab in Korea Electric Power Research Institute. Meshes of 3,650 triangular elements were used in the analysis of this SFCL. Analysis results showed that the distribution of current density was concentrated to inner curved line in meander-line type SFCL and the maximum current density was 14.61 A/$m^2$ and also the maximum Joule heat was 2,030 W/$m^2$ in this region. We think that the new and the modified structure must be considered for an uniform distribution of the electromagnetic field.

Modeling and Transient Analysis of Cable in Combined Transmission Line with HIF and Analysis of Transient Characterstic in CCPU of Uderground Cable (혼합송전선로에서 고저항 지락사고시 케이블 과도현상 해석 및 전력케이블 시스 접지저항에 따른 CCPU 과도특성 모의)

  • Jung, Che-Kyun;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.446-448
    • /
    • 2000
  • This paper discribes the modeling and transient analysis of cable in combined transmission line under high impedance fault(HIF). And also, transient characterstic analyzed on cable covering protection unit(CCPU) is presented. Modeling of the combined transmission line is established in PSCAD/EMTDC V3. The required data to analyze the transient phenomena is given from the actual system. The results show the HIF modeling in cable, fault current according to the value of fault resistance. And also when the value and method of grounding resistance is changed in CCPU, simulation results are presented.

  • PDF

A Study on the Bypassing Device for Short-fault Current produced in Low Voltage Distributed Line (저압배전계통에서 발생한 단락전류의 Bypassing 장치에 관한 연구)

  • Youn, Y.J.;Kim, O.K.;Lee, S.H.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.976-978
    • /
    • 1998
  • In this paper, we designed basic concept and structure of bypassing device which promoted the activity of low voltage line-fuse, when it perceived the too small short-fault current to activate line-fuse which located at the between secondary of pole transformer and home immediately. And we study displacement of bypass contact and electromagnetic force caused by the short-fault current by the basic experiment to understand the basic characteristic of bypassing movements.

  • PDF