• 제목/요약/키워드: Fault detection and isolation

검색결과 178건 처리시간 0.024초

프로세스고장검출을 위한 새로운 잔차발생기구 (A New Dynamic Residual Generator for Process Fault Detection)

  • 이기상;이상문
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제52권10호
    • /
    • pp.575-582
    • /
    • 2003
  • A new FDOs (fault diagnostic observers) and the residual generation schemes using the FDOs are suggested for the process fault detection and isolation of linear (control) systems. The design method of the FDO is described, first, for the full measurement systems. Then it is extended for the systems with unmeasurable state variables. An unknown input observer is proposed and applied for the extension. The size of the observer bank may be the smallest, specially in full measurement systems, because the order of the proposed FDO is very low. In spite of the simplicity, the scheme provides the same information for the detection and isolation of the anticipated faults as the conventional multiple observer based schemes. The residuals may be structured so that fault isolation can be performed by pre-selected logic. An FDIS using the proposed scheme is constructed for the model of the four-tank system. Simulation results show the practical feasibility of the proposed scheme.

비선형 시스템의 액츄에이터 고장과 센서 고장을 위한 감지 및 분리 기법 (A Detection and Isolation Scheme for Nonlinear Systems with a Actuator and Sensor Faults)

  • 한병조;황영호;김홍필;양해원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1724-1725
    • /
    • 2007
  • This paper presents a fault detection and isolation(FDI) scheme for a nonlinear systems with a actuator and sensor faults. A residual generator based on the observer model generate the information for a fault detection. The proposed fault estimators are activated for a fault isolation and applied to estimate the time-varying lumped faults(model uncertainty + fault). but a fault estimator error dose not converge to zero since the derivative of lumped fault is not zero. Then the fuzzy neural network(FNN) is used to estimate the fault estimator error. Simulation results are presented to illustrate the effectiveness and the applicability of the approaches proposed.

  • PDF

레버암 효과와 고장 감지 및 배제 성능을 고려한 여분의 3축 MEMS IMU의 평면 배치 기법 (Optimal In-Plane Configuration of 3-axis MEMS IMUs Considering Fault Detection and Isolation Performance and Lever Arm Effect)

  • 김응주;김용훈;최민준;송진우
    • 전기학회논문지
    • /
    • 제67권12호
    • /
    • pp.1648-1656
    • /
    • 2018
  • The configuration of redundant inertial sensors are very important when considering navigation performance and fault detection and isolation (FDI) performance. By constructing a redundant sensor system using multiple inertial sensors, it is possible to improve the navigation performance and fault detection and isolation performance, which are highly related to the sensor configuration and allocation. In order to deploy multiple MEMS inertial measurement units effectively, a configuration and allocation methods considering navigation performance, fault detection and isolation performance, and lever arm effect in one plane are presented, and the performance is analyzed through simulation in this research. From the results, it is confirmed that the proposed configuration and allocation method can improve navigation, FDI, and lever arm effect rejection performances more effectively by more than 70%.

진동데이터 적용 모델기반 이상진단 (Model-based Fault Diagnosis Applied to Vibration Data)

  • 양지혁;권오규
    • 제어로봇시스템학회논문지
    • /
    • 제18권12호
    • /
    • pp.1090-1095
    • /
    • 2012
  • In this paper, we propose a model-based fault diagnosis method applied to vibration data. The fault detection is performed by comparing estimated parameters with normal parameters and deciding if the observed changes can be explained satisfactorily in terms of noise or undermodelling. The key feature of this method is that it accounts for the effects of noise and model mismatch. And we aslo design a classifier for the fault isolation by applying the multiclass SVM (Support Vector Machine) to the estimated parameters. The proposed fault detection and isolation methods are applied to an engine vibration data to show a good performance. The proposed fault detection method is compared with a signal-based fault detection method through a performance analysis.

패리티 공간기법을 이용한 위치 서보계의 최적 잔차 발생 (Optimal residual generation using parity space approach for a position servo system)

  • 최경영;박태건;이기상
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.1440-1443
    • /
    • 1997
  • The optimal residual generator based on parity relation approach for the fault detection and isolation of a arge diesel engine actuator position servo system is presented. The closed-loop residual generator is designed to have robustness against modeling errors and noise. Main purpose of the fault detection and isolation system in the process is to detect and isolate two important faults, i.e., actuatro fault and fault of speed sensor, that, if not detected and compensated, degrade the overall control system performance. Simulation results are give to show the practical applicability of the fault detecrtion and isloation scherme.

  • PDF

Double Faults Isolation Based on the Reduced-Order Parity Vectors in Redundant Sensor Configuration

  • Yang, Cheol-Kwan;Shim, Duk-Sun
    • International Journal of Control, Automation, and Systems
    • /
    • 제5권2호
    • /
    • pp.155-160
    • /
    • 2007
  • A fault detection and isolation (FDI) problem is considered for inertial sensors, such as gyroscopes and accelerometers and a new FDI method for double faults is proposed using reduced-order parity vector. The reduced-order parity vector (RPV) algorithm enables us to isolate double faults with 7 sensors. Averaged parity vector is used to reduce false alarm and wrong isolation, and to improve correct isolation. The RPV algorithm is analyzed by Monte-Carlo simulation and the performance is given through fault detection probability, correct isolation probability, and wrong isolation probability.

Fault diagnosis using multiple PI observers

  • Kim, Hwan-Seong;Ki, Sang-Bong;Kawaji, Shigeyasu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 Proceedings of the Korea Automatic Control Conference, 11th (KACC); Pohang, Korea; 24-26 Oct. 1996
    • /
    • pp.287-290
    • /
    • 1996
  • Fault diagnosis problem is currently the subject of extensive research and numerous survey paper can be found. Although several works are studied on the fault detection and isolation observers and the residual generators, those are concerned with only the detection of actuator failures or sensor failures. So, the perfect detection and isolation is strongly required for practical applications. In this paper, a, strategy of fault diagnosis using multiple proportional integral (PI) observers including the magnitude of actuator failures is provided. It is shown that actuator failures are detected and isolated perfectly by monitoring the integrated error between actual output and estimated output by a PI observer. Also in presence of complex actuator and sensor failures, these failures are detected and isolated by multiple PI observers.

  • PDF

유한시간 수렴 고장검출관측자를 이용한 고장검출식별 및 보상기법 (A Fault Detection Isolation and Compensation Scheme using Finite-time Fault Detection Observers)

  • 이기상
    • 전기학회논문지
    • /
    • 제58권9호
    • /
    • pp.1802-1808
    • /
    • 2009
  • A fault detection observer with finite time convergence characteristics(FT_FDO) is proposed and applied to a fault detection isolation system for a dynamic control system. The FT_FDO is a kind of dual state-observer scheme that provides with the state estimates insensitive to a specified fault and the corresponding fault estimate. The state estimates are processed to get the residual that will be logically compared with other residuals to detect and isolate the fault of interest, and the fault estimate may be used for fault compensation. The FDIS employing the FT_FDOs can be considered to be a multiple observer schemes(MOS) in which FT_FDOs are parallelly driven to generate a set of residuals to be compared each other. Due to the finite time convergence characteristics of the FT_FDO, the predetermined detection delay can be considered in the design stage of FDIS so that any fault of interest can be detected and identified in that time. It evidently resolves a well known difficulty of threshold selection owing to the transient responses of the fault detection observers(FDO) employed in FDIS. An FDIS is constructed for instruments(2-sensor, 1-actuator) in an inverted pendulum control system, and simulations are performed to show the performance of the FDIS and fault tolerant control system.

역진자 제어계의 고장검출식별 기법 (Fault Detection and Isolation Scheme for Inverted Pendulum Control System)

  • 이상문;류지수;이기상;박태건
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 D
    • /
    • pp.2227-2229
    • /
    • 2004
  • Fault Detection and Isolation(FDI) schemes using unknown input functional observers with very low order are presented. These schemes resolve the major practical difficulties with all FDI systems employing multiple observers for residual generation and can be implemented by the use of microprocessors that are normally used in commercial processes mainly due to the simplicity of the residual generation block. Various design objectives including detection, isolation, estimation and compensation of instrument fault/or process fault are achievable with these schemes. The proposed FDI scheme is applied to an inverted pendulum control system for instrument fault detection.

  • PDF

Multiple Faults Detection and Isolation via Decentralized Sliding Mode Observer for Reconfigurable Manipulator

  • Zhao, Bo;Li, Chenghao;Ma, Tianhao;Li, Yuanchun
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권6호
    • /
    • pp.2393-2405
    • /
    • 2015
  • This paper considers a decentralized multiple faults detection and isolation (FDI) scheme for reconfigurable manipulators. Inspired by their modularization property, a global sliding mode (GSM) based stable adaptive fuzzy decentralized controller is investigated for the system in fault free, while for the system suffering from multiple faults (actuator fault and sensor fault), the decentralized sliding mode observer (DSMO) is employed to detect their occurrence. Hereafter, the time and location of faults can be determined by a fault isolation scheme via a bank of DSMOs. Finally, the effectiveness of the proposed schemes in controlling, detecting and isolating faults is illustrated by the simulations of two 3-DOF reconfigurable manipulators with different configurations successfully.