Design and Analysis of a State Feedback Controller for a Chain of Integrators System under Measurement Noise (측정에러가 있는 적분기 시스템에서의 상태 궤환 제어기 설계 및 분석)

  • Youn, Jae-Seung;Choi, Ho-Lim
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.10
    • /
    • pp.969-974
    • /
    • 2010
  • In this paper, we propose a fault-tolerant controller for compensating measurement noise of feedback sensor. Because control systems operate via feedback sensor's signal, the measurement noise in sensor's signal results in performance degradation or even system failure. Therefore, control systems often demand on compensating measurement noise. Our controller is equipped with a compensator in order to reject or reduce the effect of measurement noise in feedback information. Our proposed method is verified via simulation and experiment for a Ball and Beam system.

Fault-Tolerant Database System for managing Wind Turbine Control System (무중단의 풍력 발전 시스템 관리를 위한 고가용성 데이터베이스 시스템)

  • Kim, Young-Hwan;Son, Jae-Gi;Ham, Kyung-sun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.04a
    • /
    • pp.56-59
    • /
    • 2012
  • 최근 신재생 에너지 분야 가운데 풍력발전에 대한 관심이 높아지면서 관련 산업 분야의 연구 또한 활발히 수행되고 있다. 풍력발전기의 경우 초기 설치에 고가의 비용이 필요하며, 고장 발생 시 일반적으로 풍력발전기의 동작을 멈추게 한다. 본 논문에서는 풍력발전기의 Nacelle에서 발생하는 다양한 센서데이터를 수집하는 Bottom에서의 제어시스템을 다중화하여 고장 발생 시에도 풍력발전기의 중단 없이 지속적으로 에너지 생산이 가능하게 하는 고가용성 데이터베이스 시스템에 관한 것이다. 본 논문을 통해 개발된 고가용성 시스템을 통해 풍력 발전기의 높은 안정성을 보장하며, 수집된 데이터를 분석함으로서 고장에 대한 예측이 가능하다.

Extension of ReInForM Protocol for (m,k)-firm Real-time Streams in Wireless Sensor Networks

  • Li, Bijun;Kim, Ki-Il
    • Journal of information and communication convergence engineering
    • /
    • v.10 no.3
    • /
    • pp.231-236
    • /
    • 2012
  • For real-time wireless sensor network applications, it is essential to provide different levels of quality of service (QoS) such as reliability, low latency, and fault-tolerant traffic control. To meet these requirements, an (m,k)-firm based real-time routing protocol has been proposed in our prior work, including a novel local transmission status indicator called local DBP (L_DBP). In this paper, a fault recovery scheme for (m,k)-firm real-time streams is proposed to improve the performance of our prior work, by contributing a delay-aware forwarding candidates selection algorithm for providing restricted redundancy of packets on multipath with bounded delay in case of transmission failure. Each node can utilize the evaluated stream DBP (G_DBP) and L_DBP values as well as the deadline information of packets to dynamically define the forwarding candidate set. Simulation results show that for real-time service, it is possible to achieve both reliability and timeliness in the fault recovery process, which consequently avoids dynamic failure and guarantees meeting the end-to-end QoS requirement.

Wireless safety monitoring of a water pipeline construction site using LoRa communication

  • Lee, Sahyeon;Gil, Sang-Kyun;Cho, Soojin;Shin, Sung Woo;Sim, Sung-Han
    • Smart Structures and Systems
    • /
    • v.30 no.5
    • /
    • pp.433-446
    • /
    • 2022
  • Despite efforts to reduce unexpected accidents at confined construction sites, choking accidents continue to occur. Because of the poorly ventilated atmosphere, particularly in long, confined underground spaces, workers are subject to dangerous working conditions despite the use of artificial ventilation. Moreover, the traditional monitoring methods of using portable gas detectors place safety inspectors in direct contact with hazardous conditions. In this study, a long-range (LoRa)-based wireless safety monitoring system that features the network organization, fault-tolerant, power management, and a graphical user interface (GUI) was developed for underground construction sites. The LoRa wireless data communication system was adopted to detect hazardous gases and oxygen deficiency within a confined underground space with adjustable communication range and low power consumption. Fault tolerance based on the mapping information of the entire wireless sensor network was particularly implemented to ensure the reliable operation of the monitoring system. Moreover, a sleep mode was implemented for the efficient power management. The GUI was also developed to control the entire safety-monitoring system and to manage the measured data. The developed safety-monitoring system was validated in an indoor testing and at two full-scale water pipeline construction sites.

Reliability Analysis of a System with Redundancy Management Based on Monte-Carlo Probability Model (다중구조관리자 특성이 반영된 확률모델 기반의 몬테카를로 신뢰도 해석 기법 연구)

  • Kim, Sung-Su;Park, Sang-Hyuk;Kim, Sung-Hwan;Choi, Kee-Young;Park, Choon-Bae;Ha, Cheol-Keun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.11
    • /
    • pp.1132-1137
    • /
    • 2011
  • Critical systems with high reliability feature fault tolerant redundancy. Conventional analytical reliability analysis methods that use the Reliability Block Diagram do not adequately reflect characteristics of the redundancy management system and are not suitable for this applications. This paper uses Monte-Carlo method to calculate the reliability of complicated redundant systems. The method was first validated for cases with analytical solutions. Then, the tool was successfully applied to analyze reliability of the flight control systems with a voter as redundancy management system.

Study for the Information Operations for Long Unattended Periods of Time at the Space System

  • Kim, Han-Woong
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.4 no.2
    • /
    • pp.61-68
    • /
    • 2003
  • The space systems are being operated in a uncertain space environment and are desired to have autonomous capability for long periods of time without frequent telecommunications with the ground station. At the same time, requirements for new set of satellite system set of projects/systems calling for "autonomous" operations for long unattended periods of time are emerging. Since, by the nature of space systems, it is desired to perform its mission flawlessly and also it is of extreme importance to have fault-tolerant sensors and actuators for the purpose of validating science measurement data for the mission success. This studies focused on the identification/demonstration of critical technology innovations that will be applied to the Validation Control System.

Concurrency Control Method to Provide Transactional Processing for Cloud Data Management System

  • Choi, Dojin;Song, Seokil
    • International Journal of Contents
    • /
    • v.12 no.1
    • /
    • pp.60-64
    • /
    • 2016
  • As new applications of cloud data management system (CDMS) such as online games, cooperation edit, social network, and so on, are increasing, transaction processing capabilities for CDMS are required. Several transaction processing methods for cloud data management system (CDMS) have been proposed. However, existing transaction processing methods have some problems. Some of them provide limited transaction processing capabilities. Some of them are hard to be integrated with existing CDMSs. In this paper, we proposed a new concurrency control method to support transaction processing capability for CDMS to solve these problems. The proposed method was designed and implemented based on Spark, an in-memory distributed processing framework. It uses RDD (Resilient Distributed Dataset) model to provide fault tolerant to data in the main memory. In our proposed method, database stored in CDMS is loaded to main memory managed by Spark. The loaded data set is then transformed to RDD. In addition, we proposed a multi-version concurrency control method through immutable characteristics of RDD. Finally, we performed experiments to show the feasibility of the proposed method.

A study on the Reliability evaluation and Design of TMR system accroding to the structure of voter (보터의 구조에 따른 TMR 시스템의 신뢰도 평가 및 설계에 관한 연구)

  • Kim, Hyun-Ki;Lee, Suk-Kuin;Lee, Key-Seo
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.375-377
    • /
    • 1998
  • This paper shows two models of the TMR system- fail passive system - having a fault tolerant system characteristic used in airplane and railway system. We design the single system, single-voter TMR system and triplicated voter TMR system based on MC68000 and calculate the failure rate of components using MIL-SPEC-217F and evaluate the reliability and MTTF(Mean Time To Failure) of the designed systems by Markov model.

  • PDF

$H_{\infty}$ Controller Design for Electromagnetic Suspension System using LMIs (LMI를 이용한 자기부상 시스템의 $H_{\infty}$ 제어기 설계)

  • Jang, S.M.;Sung, S.Y.;Sung, H.K.;Kim, B.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.280-283
    • /
    • 2000
  • In this paper, a fault tolerant control problem is considered for a class of nonlinear system formulated in a gain scheduling form with LMI-based H-inf control technique Key benefits of this proposed scheme are demonstrated in the simulation of an electromagnetic suspension system with actuator and/or sensor failures, and the method is compared with the convensional state-feedback and output-feedback controller. It is clearly observed that the proposed control scheme shows an improved output performance in comparision with convensional methods.

  • PDF

Quick Diagnosis of Short Circuit Faults in Cascaded H-Bridge Multilevel Inverters using FPGA

  • Ouni, Saeed;Zolghadri, Mohammad Reza;Rodriguez, Jose;Shahbazi, Mahmoud;Oraee, Hashem;Lezana, Pablo;Schmeisser, Andres Ulloa
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.56-66
    • /
    • 2017
  • Fast and accurate fault detection is the primary step and one of the most important tasks in fault tolerant converters. In this paper, a fast and simple method is proposed to detect and diagnosis the faulty cell in a cascaded H-bridge multilevel inverter under a short circuit fault. In this method, the reference voltage is calculated using switching control pulses and DC-Link voltages. The comparison result of the output voltage and the reference voltage is used in conjunction with active cell pulses to detect the faulty cell. To achieve this goal, the cell which is active when the Fault signal turns to "0" is detected as the faulty cell. Furthermore, consideration of generating the active cell pulses is completely described. Since the main advantage of this method is its simplicity, it can be easily implemented in a programmable digital device. Experimental results obtained with an 11-level inverter prototype confirm the effectiveness of the proposed fault detection technique. In addition, they show that the diagnosis method is unaffected by variations of the modulation index.