• Title/Summary/Keyword: Fault Screening

Search Result 10, Processing Time 0.02 seconds

Development of Digital Fault Detection Systems for Screening Open and Short of Wire Harness (와이어 하네스 단선 단락 선별을 위한 디지털 고장 검출 시스템 개발)

  • A Ran Kim;Jae Wan Park;Ha Seon Kim;Jae Hoon Jeong;Sun Young Kim
    • Journal of Drive and Control
    • /
    • v.20 no.4
    • /
    • pp.140-149
    • /
    • 2023
  • Wire harness is a component for efficient control when electronic parts are required such as construction machinery and electric vehicles. With emerging issues such as autonomous driving and automation in construction, a wire harness composed of multiple cables has become an essential part because more electronic parts are required. However, when a wire harness failure occurs, systems can be stopped, accidents can occur, and economic damage can be significant. Therefore, in this paper, we developed a digital fault screening system that could easily and quickly diagnose faults in the wire harness. The principle of the developed system was to sequentially send pulse signals to the wire harness and use returned signals to perform fault detection. As a result of diagnosing faults using the developed failure detection system, a detection accuracy of 99.9 % was confirmed through the experiments.

A Fast Contingency Screening Algorithm for On-line Transient Security Assessment Based on Stability Index

  • Nam, Hae-Kon;Kim, Yong-Hak;Song, Sung-Geun;Kim, Yong-Gu
    • KIEE International Transactions on Power Engineering
    • /
    • v.2A no.4
    • /
    • pp.131-135
    • /
    • 2002
  • This paper describes a new ultra-fast contingency screening algorithm for on-line TSA without time simulation. All machines are represented in a classical model and the stability index is defined as the ratio between acceleration power during a fault and deceleration power after clearing the fault. Critical clustering of machines is done based on the stability index, and the power-angle curve of the critical machines is drawn assuming that the angles of the critical machines increase uniformly, while those of the non-critical ones remain constant. Finally, the critical clearing time (CCT) is computed using the power-angle curve. The proposed algorithm is tested on the KEPCO system comprised of 900-bus and 230-machines. The CCT values computed with the screening algorithm are in good agreement with those computed using the detailed model and the SIME method. The computation time for screening about 270 contingencies is 17 seconds with 1.2 GHz PC.

Transferred OverVoltages on LV sides in Multigrounded Neutral during Line to Ground Fault on Distribution Systems (배전계통의 고저압 혼촉고장시 중성선 전위상승에 따른 저압기기 스트레스 전압)

  • Choi, Sun-Kyu;Choi, Jong-Kee;Kim, Kyoung-Hun;Choi, Myeong-Ho;Lee, Byung-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.6
    • /
    • pp.910-915
    • /
    • 2012
  • In this paper we propose multi-grounded neutral design method which was considered of transferred transient overvoltage when line to neutral fault occurs. Specially, In order to confirm the actual transient overvoltage magnitude which occurs on neutral line, we considered some screening(shielding) effects. The screening coefficient was deducted from field test results and calculation in a distribution line which is identical with an actual power line. The purpose of this paper is to attempt to suggest the guidance for grounding skystem design considering limitation of overvoltage for LV side in IEC 61936. The result is based on EMTP simulation and real field faults situation in distribution lines.

Development of On-line Dynamic Security Assessment System (온라인 동적 안전도평가 시스템의 개발)

  • Nam, H.K.;Song, S.G.;Shim, K.S.;Moon, C.J.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.73-76
    • /
    • 2001
  • This paper presents a new systematic contingency selection, screening and ranking method for on-line transient security assessment. Transient stability of a particular generator is influenced most by fault near it. Fault at the transmission lines adjacent to the generators are selected as contingency. Two screening methods are developed using the sensitivity of modal synchronizing torque coefficient and computing an approximate critical clearing time(CCT) without time simulation. The first method, which considers only synchronizing power, may mislead in some cases since it does not consider the acceleration power. The approximate CCT method, which consider both the acceleration and deceleration power, worked well. Finally the Single Machine Equivalent(SIME) method is implemented using IPLAN of PSS/E for detailed stability analysis.

  • PDF

A Two-Step Screening Algorithm to Solve Linear Error Equations for Blind Identification of Block Codes Based on Binary Galois Field

  • Liu, Qian;Zhang, Hao;Yu, Peidong;Wang, Gang;Qiu, Zhaoyang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.9
    • /
    • pp.3458-3481
    • /
    • 2021
  • Existing methods for blind identification of linear block codes without a candidate set are mainly built on the Gauss elimination process. However, the fault tolerance will fall short when the intercepted bit error rate (BER) is too high. To address this issue, we apply the reverse algebra approach and propose a novel "two-step-screening" algorithm by solving the linear error equations on the binary Galois field, or GF(2). In the first step, a recursive matrix partition is implemented to solve the system linear error equations where the coefficient matrix is constructed by the full codewords which come from the intercepted noisy bitstream. This process is repeated to derive all those possible parity-checks. In the second step, a check matrix constructed by the intercepted codewords is applied to find the correct parity-checks out of all possible parity-checks solutions. This novel "two-step-screening" algorithm can be used in different codes like Hamming codes, BCH codes, LDPC codes, and quasi-cyclic LDPC codes. The simulation results have shown that it can highly improve the fault tolerance ability compared to the existing Gauss elimination process-based algorithms.

Research on diagnosis method of centrifugal pump rotor faults based on IPSO-VMD and RVM

  • Liang Dong ;Zeyu Chen;Runan Hua;Siyuan Hu ;Chuanhan Fan ;xingxin Xiao
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.827-838
    • /
    • 2023
  • Centrifugal pump is a key part of nuclear power plant systems, and its health status is critical to the safety and reliability of nuclear power plants. Therefore, fault diagnosis is required for centrifugal pump. Traditional fault diagnosis methods have difficulty extracting fault features from nonlinear and non-stationary signals, resulting in low diagnostic accuracy. In this paper, a new fault diagnosis method is proposed based on the improved particle swarm optimization (IPSO) algorithm-based variational modal decomposition (VMD) and relevance vector machine (RVM). Firstly, a simulation test bench for rotor faults is built, in which vibration displacement signals of the rotor are also collected by eddy current sensors. Then, the improved particle swarm algorithm is used to optimize the VMD to achieve adaptive decomposition of vibration displacement signals. Meanwhile, a screening criterion based on the minimum Kullback-Leibler (K-L) divergence value is established to extract the primary intrinsic modal function (IMF) component. Eventually, the factors are obtained from the primary IMF component to form a fault feature vector, and fault patterns are recognized using the RVM model. The results show that the extraction of the fault information and fault diagnosis classification have been improved, and the average accuracy could reach 97.87%.

A semi-supervised interpretable machine learning framework for sensor fault detection

  • Martakis, Panagiotis;Movsessian, Artur;Reuland, Yves;Pai, Sai G.S.;Quqa, Said;Cava, David Garcia;Tcherniak, Dmitri;Chatzi, Eleni
    • Smart Structures and Systems
    • /
    • v.29 no.1
    • /
    • pp.251-266
    • /
    • 2022
  • Structural Health Monitoring (SHM) of critical infrastructure comprises a major pillar of maintenance management, shielding public safety and economic sustainability. Although SHM is usually associated with data-driven metrics and thresholds, expert judgement is essential, especially in cases where erroneous predictions can bear casualties or substantial economic loss. Considering that visual inspections are time consuming and potentially subjective, artificial-intelligence tools may be leveraged in order to minimize the inspection effort and provide objective outcomes. In this context, timely detection of sensor malfunctioning is crucial in preventing inaccurate assessment and false alarms. The present work introduces a sensor-fault detection and interpretation framework, based on the well-established support-vector machine scheme for anomaly detection, combined with a coalitional game-theory approach. The proposed framework is implemented in two datasets, provided along the 1st International Project Competition for Structural Health Monitoring (IPC-SHM 2020), comprising acceleration and cable-load measurements from two real cable-stayed bridges. The results demonstrate good predictive performance and highlight the potential for seamless adaption of the algorithm to intrinsically different data domains. For the first time, the term "decision trajectories", originating from the field of cognitive sciences, is introduced and applied in the context of SHM. This provides an intuitive and comprehensive illustration of the impact of individual features, along with an elaboration on feature dependencies that drive individual model predictions. Overall, the proposed framework provides an easy-to-train, application-agnostic and interpretable anomaly detector, which can be integrated into the preprocessing part of various SHM and condition-monitoring applications, offering a first screening of the sensor health prior to further analysis.

An Integrative Method of FTA and FMEA for Software Security Analysis of a Smart Phone (스마트 폰의 소프트웨어 보안성 분석을 위한 FTA와 FMEA의 통합적 방법)

  • Kim, Myong-Hee;Toyib, Wildan;Park, Man-Gon
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.2 no.12
    • /
    • pp.541-552
    • /
    • 2013
  • Recently software security of the smart phone is an important issue in the field of information science and technology due to fast propagation of smart technology in our life. The smart phone as the security critical systems which are utilizing in terminal systems of the banking, ubiquitous home management, airline passengers screening, and so on are related to the risk of costs, risk of loss, risk of availability, and risk by usage. For the security issues, software hazard analysis of smart phone is the key approaching method by use of observed failures. In this paper, we propose an efficient integrative framework for software security analysis of the smart phone using Fault Tree Analysis (FTA) and Failure Mode Effect Analysis (FMEA) to gain a convergence security and reliability analysis technique on hand handle devices. And we discuss about that if a failure mode effect analysis performs simpler, not only for improving security but also reducing failure effects on this smart device, the proposed integrative framework is a key solution.

Analysis of court rulings on involuntary manslaughter or at-fault injury due to professional negligence by pediatric nurses: a systematic content analysis study

  • Song, Sung Sook;Kim, Eun Joo
    • Child Health Nursing Research
    • /
    • v.28 no.2
    • /
    • pp.91-102
    • /
    • 2022
  • Purpose: This study systematically analyzed cases in South Korea wherein nurses were prosecuted for involuntary manslaughter or injury due to professional negligence in pediatric care. Methods: We analyzed the precedents using the methodology of Hall and Wright (2008) and Austin (2010). Of the 618 cases retrieved from the Supreme Court Decisions Retrieval System in South Korea, we selected the 12 cases in which children were the victims and nurses were the defendants, using a case screening methodology. Results: The most frequent penalty was a fine, and newborns were the most frequent victims. The distribution of cases according to Austin's violation categories was: improper administration of medications (n=5), failure to monitor for and report deterioration (n=4), ineffective communication (n=4), failure to delegate responsibly (n=4), failure to know and follow facility policies and procedures (n=1), and improper use of equipment (n=1). Conclusion: To ensure the safety of children, nurses are required to teach and practice a high standard of care. Nursing education programs must improve nurses' awareness of their legal obligations. Nursing organizations and leaders should also work towards enacting effective nursing laws and ensuring that nurses are aware of their legal rights and responsibilities.

Seismic risk estimation of the Kirikkale province through street survey based rapid assessment method (SSRA)

  • Sonmezer, Yetis Bulent;Bas, Selcuk;Akbas, Sami Oguzhan
    • Earthquakes and Structures
    • /
    • v.14 no.6
    • /
    • pp.615-626
    • /
    • 2018
  • The seismic vulnerability of Turkey is relatively high due to its active fault systems with potential to create destructive earthquakes. Thus, reducing the loss of life and property, the number of the earthquake-prone buildings and their retrofit requirements are considerably significant key issues under the scenario earthquakes. The street survey based rapid assessment (SSRA) method can be considered as a powerful tool to determine the seismic vulnerability of building stock of an earthquake-prone city/state. In this study, the seismic vulnerability of the building stock of the Kirikkale province in Turkey is aimed to be estimated adopting the street survey based rapid assessment method (SSRA). For this purpose, central 2074 existing reinforced concrete (R/C) buildings were structurally surveyed with rapid visual site screening and disadvantages such as, the existence of short-column, soft-story, heavy overhangs, pounding effect and local soil conditions were determined for obtaining the structural performance score of each. The results obtained from the study demonstrate that 11-25% of the surveyed buildings in the study region needs to be investigated through more advanced assessment methods. Besides, higher correlation between increasing story number and unsafe/safe building ratio is obtained for the buildings with soft-story parameter than that for those with heavy overhangs and short-column parameters. The conformity of the results of the current study with the previous documented cases of rapid assessment efforts in the recent earthquakes in Turkey shows that the SSRA method for the Kirikkale province performed well, and thus this methodology can be reliably used for similar settlement areas.