• Title/Summary/Keyword: Fatigue accumulation

Search Result 108, Processing Time 0.032 seconds

Case Report for Severe Hepatitis A Treated in a Korean Hospital

  • Kim, Sul-Ki;Jeon, Cheon-Hoo;Lee, Nam-Heon;Cho, Jung-Hyo;Son, Chang-Gue
    • The Journal of Korean Medicine
    • /
    • v.41 no.4
    • /
    • pp.100-105
    • /
    • 2020
  • A 25-year-old male presented with influenza-like symptoms and took Western anti-inflammatory analgesic drugs for 2 days. The symptoms aggravated, so the patient decided to rely on Korean medicine (KM). Based on the highly elevated hepatic enzymes (AST 4,621 IU/L and ALT 2,763 IU/L) with a positive result of anti-HAV IgM, he was diagnosed with hepatitis A. The patient was hospitalized and given herbal drugs (Chunggan-plus extract, Innae-Tang) and acupuncture, according to symptom differentiation, the accumulation of damp heat (濕熱蘊結)". The subjective symptoms (fatigue, nausea, gastric discomfort) including jaundice and dark urine as well as laboratory abnormalities gradually improved gradually in 10 hospital days, and the patient completely recovered in 25 days as an out-patient. This case presents a classic case of severe hepatitis A in 2019 Korean outbreak, and is informative to physicians for diagnosis and treatment in the traditional Korean medicine field.

A Clinical Study on Syndrome Differentiation of Male with Teeth-Mark Tongue (남자(男子) 치흔설(齒痕舌) 변증에 관한 임상적 고찰)

  • Lee, Soo-Jung;Baek, Sang-In;Lee, Byung-Gwon;Lee, Ah-Ram;Kim, Koang-Lok;Yoon, Hyun-Min;Kim, Won-Il
    • Journal of Pharmacopuncture
    • /
    • v.13 no.4
    • /
    • pp.91-107
    • /
    • 2010
  • Objectives : The purpose of this study was to analyze the propensity and find out the Syndrome Differentiation of teeth-mark tongue by taking survey and body examinations with 178 male patients. 164 patients out of 178 were checked up on Heart Rate Variability (HRV), Accelerated Photoplethysmograpy (APG), Body Composition. This study was also planned to find out the distinctive characteristics of teeth-mark tongue diagnosis and compare differences between Qi-Deficiency and Accumulation of Dampness and Phlegm patients group. Methods : The questionnaire was carried out targeting 178 male with teeth-mark tongue respondents among who had Oriental Health Examination and patients from the 3rd oriental-internal medicine department in Dongeui Hospital from $1^{st}$, March 2005 to $30^{th}$, April 2010. Only 164 patients were checked on HRV, APG and Body composition examinations. Results : It showed that 86 patients had Qi-Deficiency and 78 had Dampness and Phlegm but 14 couldn't be categorized. The major symptoms of Qi-Deficiency compared to Dampness and Phlegm were 'Frequent running nose', 'Soft stool', 'Chronic fatigue', and 'Eyestrain'. On the contrary, Dampness and Phlegm's dominant symptoms were 'Chest discomfort', 'Feeling bloated', 'Back pain', 'Feeling sluggish', and 'Itchy skin'. However, all symptoms were not matched with the Syndrome Differentiation of Qi-Deficiency or Dampness and Phlegm. It also showed that teeth-mark tongue patients' frequent symptoms were 'Stuffy nose', 'Feeling bloated', 'Oliguria', 'Shoulder pain', 'Chronic fatigue' 'Eyestrain' and these symptoms were matched with the Syndrome Differentiation of Qi-Deficiency and Dampness and Phlegm. In the results from this study, there were no significant differences between Qi-Deficiency and Dampness and Phlegm. Conclusions : It is hard to conclude that teeth-mark tongue could be only one to diagnose Qi-Deficiency or Dampness and Phlegm with 3 examinations.

Fabrication of Bendable Gd2O2S:Tb Intensifying Screen and Evaluation of Fatigue Properties (유연한 Gd2O2S:Tb 증감지 제작 및 피로누적에 대한 영향)

  • Park, Ji-Koon;Yang, Sung-Woo;Jeon, Je-Hoon;Kim, Joo-Hee;Heo, Ye-Ji;Kang, Sang-Sik;Kim, Kyo-Tae
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.611-617
    • /
    • 2017
  • In this study, it was expected that long-term stability against external mechanical external force could be secured if the phosphor layer had ductility. In this study, a bendable $Gd_2O_2S:Tb$ sensitized paper was fabricated by screen printing method and the image uniformity was evaluated through RMS analysis and histogram analysis to investigate the effect of fatigue accumulation due to long-term external force and repetitive external force. As a result, the dominant pixel area is maintained constant and the relative standard deviation is less than 10% for the long-term external force. However, for the repetitive external force, the dominant pixel area is divided into three areas and the image uniformity is adversely affected. Based on these results, it is suggested that the curved surface detector can be applied by securing the mechanical stability against the existing radiation sensitized paper. However, further studies are needed to apply it to the flexible detector. As a result, flexible radiation sensitizers can be applied to various curved surfaces, and it is expected to be applicable to various fields such as nuclear medicine, medical treatment, and industrial fields in the future.

The quality improvement study on the crack of heat exchanger lubricating oil port in military aircraft (군용항공기 열교환기 윤활유 유입포트 균열개선 연구)

  • Park, Sung-Jae;Choi, Jae-Ho;Choi, Gil-Gyu;Lee, Dong-Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.164-172
    • /
    • 2020
  • The fuel oil/heat exchanger installed in military aircraft is a device that cools the lubricant oil supplied to other devices, such as an AMAD, and a hydraulic pump using the low temperature of the fuel is cracked at the AMAD lubricant inlet port. If a crack in the heat exchanger occurs, the lubricant oil supplied to other equipment is not cooled. Therefore, the flight can no longer be performed. In this study, non-destructive inspection and microscopic examination of the fracture surface of the oil port were performed to analyze the crack tendency. The oil pipe connected to the oil port is a titanium pipe, which is fastened with over torque and has been identified as the leading cause of heat exchanger oil port cracks. In addition, it was verified as the main reason for cracking by finite element analysis. The material and diameter of the pipe were changed to improve this defect, and the applied torque was adjusted. In addition, the bending value of the pipe was adjusted to minimize the fatigue accumulation due to pulsating pressure. As a result, no cracks occurred on the heat exchanger via the ground test after the installation of an improved pipe under the same conditions.

A STUDY ON SURFACE ALTERATION OF IMPLANT SCREWS AFTER FUNCTION

  • Han, Myung-Ju;Chung, Chae-Heon;Choi, Han-Cheol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.3
    • /
    • pp.275-286
    • /
    • 2002
  • Statement of problem. Surface alteration of the implant screws after function may be associated with mechanical failure. Theses metal fatigue appears to be the most common cause of structural failure. Purpose. The purpose of this study was to evaluate surface alteration of the implant screws after function through the examination of used and unused implant screws in SEM(scanning electron microscope). Materials and methods. In this study, abutment screws(Steri-oss, 3i), gold retaining screw(3i) and titanium retaining screw(3i) were retrieved from patients. New, unused abutment and retaining screws were prepared for control group. Each of the old, used screws was retrieved with a screwdriver. And retrieved implant complex of Steri-oss system was prepared for this study. Then, SEM investigation and EDS analysis of abutment and retaining screws were performed. And SEM investigation of cross-sectioned sample of retrieved implant complex was performed. Results. In the case of new, unused implant screws, as maunfactured circumferential grooves are regularly examined and screw thread are sharply remained. Before ultrasonic cleansing of old, used implant screw, a lot of accumulation and corrosion products were existed. After ultrasonic cleansing of old, used implant screws, circumferential grooves as examined before function were randomly deepened and scratches increased. Also, dull screw thread was examined. More surface alterations after function were examined in titanium screw than gold screw. And more surface alteration was examined when retrieved with driver than retrieved without driver. Conclusions. These surface alteration after function may result in the screw instability. Regularly cleansing and exchange of screws was recommended. We recommend the use of gold screw rather than titanium screw, and careful manipulation of the driver.

Effects of Cordyceps militaris on $CCl_4$ - Induced Liver Damage and Cancer Cell (HepG2 Cell) Growth (동충하초가 사염화탄소로 유발된 간 손상 및 간암세포증식에 미치는 영향)

  • Kim San;Hwang Choong yeon;Kim Nam kwen;Park Min cheul;Kim Jin
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.16 no.4
    • /
    • pp.684-692
    • /
    • 2002
  • Cordyceps militaris has been known as a Chinese traditional medicine for the treatment of tuberculosis, asthma, kidney disease, debility and fatigue etc. This study was attempted to investigate the therapeutic effect of C. militaris extract on the cytotoxic activity of HepG2, human hepatocellular carcinoma cells and the liver damage induced by carbon tetrachloride in SD rats. C. militaris extracts inhibited significantly the proliferation of HepG2 cells in vitro. Carbon tetrachloride(CCl₄) caused a significant an increase in liver weight, serum aspartate aminotransferase(AST) and alanine aminotransferase(ALT) activity, alkaline phosphatase(ALP), serum thiobarbituric acid reactive substances (TBARS), microsomal TBARS, and decrease in microsomal detoxification enzymes (cytochrome P-450, P-450 reductase, cytochrome b5, b5 reductase). TBARS and ALP in serum pretreated with C. militaris extracts (300mg/kg/day, 600mg/kg/day) was significantly reduced compared to control group(CCl₄). Cytochrome b5 and b5 reductase activities were significantly increased in CM300 (300 mg/kg/day) and CM600 group(600 mg/kg/day), and cytochrome P-450 reductase was significantly increased in CM300 group. Pretreatment (100, 300, and 600 mg/kg/day for 7 days) of C. militaris with CCl₄ was significantly inhibited the accumulation microsomal TBARS and the significantly increased in the cytochrome P-450 activity. These results suggested that C. militaris (300mg/kg/day for 7 days) has appreciable therapeutic effect on CCl₄ induced hepatotoxicity.

Design of electromagnetic type transducer to drive round window with high efficiency (고효율 전자기형 정원창 구동 트랜스듀서의 설계)

  • Lee, Jang-Woo;Kim, Dong-Wook;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.449-455
    • /
    • 2010
  • Implantable middle ear hearing devices(IMEHDs) have being actively studied to overcome the problems of conventional hearing aids. Vibration transducer, an output devices of IMEHDs, is attached on the ossicular chain and transmits mechanical vibration to cochlea. This approach allows us to hear more clear sound because mechanical vibration is effective to transfer high frequency acoustics, but occurs some problems such as fatigue accumulation to ossicular chian and reduction of vibration displacement caused by mass loading effect. Recently, many studies for the round window stimulation are announced, because it does not cause such problems. It have been studied by older transducers designed for attaching on ossicular chain. In this paper, we proposed a new electromagnetic transducer which consists of two magnets, three coils and a vibration membrane. The magnet assembly, magnet coupled in opposite direction, were placed in the center of three coils, and the optimum length of each coil generating maximum vibrational force was calculated by finite element analysis(FEA). The transducer was implemented as the calculated length of each coil, and measured vibration displacement. From the results, it is verified the vibration displacement can be improved by optimizing the length of coils.

Long-term administration of red ginseng non-saponin fraction rescues the loss of skeletal muscle mass and strength associated with aging in mice

  • Cho, Da-Eun;Choi, Gwang-Muk;Lee, Yong-Seok;Hong, Joon-Pyo;Yeom, Mijung;Lee, Bombi;Hahm, Dae-Hyun
    • Journal of Ginseng Research
    • /
    • v.46 no.5
    • /
    • pp.657-665
    • /
    • 2022
  • Background: Sarcopenia is a new and emerging risk factor aggravating the quality of life of elderly population. Because Korean Red Ginseng (RG) is known to have a great effect on relieving fatigue and enhancing physical performance, it is invaluable to examine its potential as an anti-sarcopenic drug. Methods: Anti-sarcopenic effect of non-saponin fraction of Korean Red Ginseng (RGNS) was evaluated in C2C12 myoblasts treated with C2-ceramide to induce senescence phenotypes, and 22-month-old mice fed with chow diet containing 2% RGNS (w/w) for 4 further months. Results: The RGNS treatment significantly alleviated cellular senescence indicated by intracellular lipid accumulation, increased amount of lysosomal β-galactosidase, and reduced proliferative capacity in C2C12 myoblasts. This effect was not observed with saponin fraction. In an aged mouse, the 4-month-RGNS diet significantly improved aging-associated loss of muscle mass and strength, assessed by the weights of hindlimb skeletal muscles such as tibialis anterior (TA), extensor digitorum longus (EDL), gastrocnemius (GN) and soleus (SOL), and the cross-sectional area (CSA) of SOL muscle, and the behaviors in grip strength and hanging wire tests, respectively. During the same period, an aging-associated shift of fast-to slow-twitch muscle in SOL muscle was also retarded by the RGNS treatment. Conclusions: These findings suggested that the long-term diet of RGNS significantly prevented aging-associated muscle atrophy and reduced physical performance, and thus RGNS has a strong potential to be developed as a drug that prevents or improves sarcopenia.

Assessment of the Risks of Occupational Diseases of the Passenger Bus Drivers

  • Golinko, Vasyl;Cheberyachko, Serhiy;Deryugin, Oleg;Tretyak, Olena;Dusmatova, Olga
    • Safety and Health at Work
    • /
    • v.11 no.4
    • /
    • pp.543-549
    • /
    • 2020
  • Background: The working conditions of bus drivers are difficult; they lead to occupational diseases and require careful study, particularly in Ukraine. The objective of the article is the description of occupational health risks of passenger bus drivers that lead to deteriorating health. Methods: The risk assessment was performed using a modified Risk Score method, which allowed determining the generalized level of danger to the driver's health. The hygienic hazards level was assessed as based on Stevenson's law, which was generalized later. Results: Based on the modification of the Risk Score method, it was possible to depart from expert assessments method of the risk level and calculate the general indicator based on the degree of dependence of the impact on the human body on its intensity, proposed by V. Minko. This allows objective determining of the impact of hygiene hazards on the health of the driver and to predict the occurrence of occupational diseases associated with the cardiovascular system, musculoskeletal system, and partial or complete disability due to the accumulation of emotional fatigue. The hazard assessment was carried out for three brands of passenger buses common in Ukraine, in which the driver is exposed to the dangers of fever, vibration, noise, harmful impurities in the bus cabin, and emotional load. Conclusion: The health of drivers in the cabins of passenger buses is most affected by hygiene hazards: fever, vibration, and emotional stress. The generalized level of risk is calculated by the modified method of Risk Score is 0.83; -0.99, -0.92 respectively.

Theoretical Heat Flow Analysis and Vibration Characteristics During Transportation of PCS(Power Conversion System) for Reliability (전력변환장치 캐비넷에서의 내부발열 개선을 위한 열유동 분석 및 유통안전성 향상을 위한 진동특성 분석)

  • Joo, Minjung;Suh, Sang Uk;Oh, Jae Young;Jung, Hyun-Mo;Park, Jong-Min
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.28 no.2
    • /
    • pp.143-149
    • /
    • 2022
  • PCS needs to freely switch AC and DC to connect the battery, external AC loads and renewable energy in both directions for energy efficiency. Whenever converting happens, power loss inevitably occurs. Minimization of the power loss to save electricity and convert it for usage is a very critical function in PCS. PCS plays an important role in the ESS(Energy Storage System) but the importance of stabilizing semiconductors on PCB(Printed Circuit Board) should be empathized with a risk of failure such as a fire explosion. In this study, the temperature variation inside PCS was reviewed by cooling fan on top of PCS, and the vibration characteristics of PCS were analyzed during truck transportation for reliability of the product. In most cases, a cooling fan is mounted to control the inner temperature at the upper part of the PCS and components generating the heat placed on the internal aluminum cooling plate to apply the primary cooling and the secondary cooling system with inlet fans for the external air. Results of CFD showed slightly lack of circulating capacity but simulated temperatures were durable for components. The resonance points of PCS were various due to the complexity of components. Although they were less than 40 Hz which mostly occurs breakage, it was analyzed that the vibration displacement in the resonance frequency band was very insufficient. As a result of random-vibration simulation, the lower part was analyzed as the stress-concentrated point but no breakage was shown. The steel sheet could be stable for now, but for long-term domestic transportation, structural coupling may occur due to accumulation of fatigue strength. After the test completed, output voltage of the product had lost so that extra packaging such as bubble wrap should be considered.