• Title/Summary/Keyword: Fatigue Threshold

Search Result 141, Processing Time 0.026 seconds

Effect of Experimental Muscle Fatigue on Muscle Pain and Occlusal Pattern (실험적으로 유발되는 근피로가 근통증 및 교합양상에 미치는 영향)

  • Kim, Jae-Chang;Lim, Hyun-Dae;Kang, Jin-Kyu;Lee, You-Mee
    • Journal of Oral Medicine and Pain
    • /
    • v.33 no.3
    • /
    • pp.279-294
    • /
    • 2008
  • This study aimed to make an analysis of the occlusion in the state of muscle fatigue produced by excessive mouth opening and clenching during the dental treatment to control the dental pain and to evaluate the sensory nerve in the muscle pain state. Most of the reasons why patients visit the dental office result in pain-either conceivably the dental origin pain or the non-dental origin pain. The dental offices have many therapeutic actions to produce the masticatory muscle fatigue for the treatment. Dental treatment with long minutes of mouth opening can cause some headaches, masticatory muscle pain and mouth opening difficulties. Patients with mastication problems who visits a dental office to alleviate pain run against another unexpected pain with other aspects. This study uses T-scan II system(Tekscan Co., USA) for the evaluation on the occlusal pattern in the experimental muscle fatigue after clenching, opening the mouth excessively and chewing gum. The occlusal contact pattern is analyzed by the contact timing, namely first, intercuspal, maximum and end point of contact. This inspection was performed at frequencies of 2000Hz, 250 Hz and 5 Hz before and after each experimental muscle pain was produced to 24 subjects who had normal occlusion without the orthodontic treatment or a wide range of the prosthesis by using $neurometer^{\circledR}$ CPT/C(Neurotron, Inc. Baltimore, Maryland, USA). The measuring sites were mandibular nerve experimental muscle fatigue respectively. This study could obtain the following results after the assessment of occlusion and sensory nerve of the experimental muscle fatigue. 1. There were the fastest expression after the excessive mouth opening in muscle fatigue and after tooth clenching in muscle pain. In the visual analog scale that records the subjective level, there was the highest scale after the clenching in the muscle fatigue in jumping off the point of pain. 2. Tooth contact time, contact force, relative contact force on the point of the first contact had no difference, and there were decreases in the contact force after the excessive mouth opening on intercuspal position point, after the excessive mouth opening and the gum chewing on the point of the maximum, and in the contact time after all the experimental muscle fatigue state on the point of the end contact. 3. There was no statistic significance in the current perception threshold before and after the experimental muscle fatigue. 4. There was no significant difference in the contact number, the maximal contact number on the point of the first contact, and the contact number after the mouth opening and gum chewing on the point of the intercuspal position and the contact number after the experimental muscle fatigue on the maximum point, and showed significant decreases. In conclusion, it was found that the occlusal pattern can cause the changes on the case of the clinical muscle weakness by intra-external oral events. It was important that the sedulous attention to details is required during dental treatment in case of excessive mouth opening, mastication and clenching.

FATIGUE DESIGN OF BUTT-WELDED TUBULAR JOINTS

  • Kim, D. S.;S. Nho;F. Kopp
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.127-132
    • /
    • 2002
  • Recent deepwater offshore structures in Gulf of Mexico utilize butt welded tubular joints. Application of welded tubular joint includes tendons, production risers, and steel catenary risers. Fatigue life assessment of these joints becomes more critical because the structures to which they are attached are allowed to undergo cyclic and sometimes large displacements around an anchored position. Estimating the fatigue behavior of these tubular members in the design stage is generally conducted by using S-N curves specified in the codes and standards. Applying the stress concentration factor of the welded structure to S-N approach often results in very conservative assessment because the stress field acting on the tubular has a non-uniform distribution through the thickness. Fracture mechanics and fitness for service (FFS) technology have been applied in the design of the catenary risers. This technology enables the engineer to establish proper requirements on weld quality and inspection acceptance criteria to assure satisfactory structural integrity during its design life. It also provides guidance on proper design curves to be used and a methodology for accounting for the effects of non-uniform stress distribution through the wall thickness. An attempt was made to develop set of S-N curves based on fracture mechanics approach by considering non-uniform stress distribution and a threshold stress intensity factor. Series of S-N curves generated from this approach were compared to the existing S-N curves. For flat plate butt joint, the S-N curve generated from fracture mechanics matches with the IIW class 100 curve when initial crack depth was 0.5 mm (0.02"). Similar comparison with API X′ was made for tubular joint.. These initial crack depths are larger than the limits of inspection by current Non-destructive examination (NDE) means, such as Automatic Ultrasonic Inspection (AUT). Thus a safe approach can be taken by specifying acceptance criteria that are close to limits of sizing capability of the selected NDE method. The comparison illustrates conservatism built into the S-N design curve.

  • PDF

Characteristics of surface fatigue crack in carbon steel, used for machinery structure, under threshold conditions (기계구조용 탄소강의 표면피로균열의 하한계 특성)

  • Lee, Jong-Hyung;Song, Deuk-Jung;Lee, Sang-Young;An, Se-Won
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.7 no.4
    • /
    • pp.407-410
    • /
    • 2004
  • There have been numberous structure-related accidents including structural destruction from past to the present. This experiment used a beachmark technique that does not exceed the maximum stress and reduce the range of amplitude(or alternating stress).Difference in stress on the actual section affects the progress of crack.

  • PDF

Literature Review on One.Handed Manual Material Handling (한손 수동물자취급에 관한 문헌 조사)

  • Mo, Seung-Min;Kwag, Jong-Seon;Jung, Myung-Chul
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.5
    • /
    • pp.819-829
    • /
    • 2010
  • By referring thirty-seven previous studies on manual material handling (MMH), this paper analyzed guidelines and main factors of one-handed tasks. The previous studies concerned main factors of distance, weight, frequency, posture, gender, age, training, direction of force, height of the force exerted, and object shape and size. Based on these factors, the criteria used to understand one-handed tasks were objective measures of maximum strength, reaction force, etc., psychophysical measures of maximum acceptable frequency and weight, etc., and physiological measures of oxygen uptake, heart rate, electromyography, etc. An allowance threshold model regarding quantitative and objective fatigue and workload would be suggested for future research. This study would be expected that it serve to establish and Korean recommendations of one-handed tasks.

Moving Window Based Overload Detection Algorithm for Excavator (Moving Window 기반 굴삭기용 과부하 검출 알고리즘)

  • Yu, Chang-Ho;Choi, Jae-Weon;Seo, Young-Bong
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.909-914
    • /
    • 2007
  • In this paper, an overload detecting algorithm for an excavator is presented. The proposed overload detecting algorithm is based on the time series analysis especially moving window. The main purpose of this paper is to prevent a damage or crack from the fatigue in advance. 16 channel sensors data are considered and maximum stress is computed by a sensor fusion method every moving window. After the maximum stress every window is compared with a given threshold, this overload detecting algorithm decides overload or not.

  • PDF

A study on the ergonomic aspects of the proper luminance level of displays

  • Lee, Eunjung;Kim, Sangho;Park, HyeRyoung;Bae, Jaewoo;Lee, Seungbae;Kim, Haksun
    • Journal of Information Display
    • /
    • v.13 no.4
    • /
    • pp.159-166
    • /
    • 2012
  • In this paper, a display's emotional image quality can be primarily determined by designing the proper luminance level. Though displays with high luminance are preferred, too much light emission from a display may cause glare or visual fatigue to viewers. To find out the proper luminance level based on various video contents, this study was conducted with an OLED display with a real-black level and a wide color gamut, and with an LCD display with a high luminance level, to set the glare threshold under various conditions. The optimum luminance levels according to the display's loading ratio were found, and the maximum luminance that did not cause a glare in the test is proposed.

Small Fiber Neuropathy and Postural Orthostatic Tachycardia Syndrome after Human Papillomavirus Vaccination (사람유두종바이러스 백신접종 후 발생한 소섬유신경병과 기립빈맥증후군)

  • Lee, Chaewon;Lim, Young-Min;Ko, Myung-A;Kim, Hyunjin;Kim, Kwang-Kuk
    • Journal of the Korean neurological association
    • /
    • v.36 no.4
    • /
    • pp.318-321
    • /
    • 2018
  • We describe a 44-year-old woman with paresthesia, fatigue, and palpitation, 10 days after human papillomavirus (HPV) vaccination. The quantitative sensory test showed abnormal detection threshold in her foot. Tilt test result indicated postural orthostatic tachycardia syndrome. Symptoms were improved after immunomodulating therapy, pain control drug, and oral beta blocker medication. This is first case report for small fiber neuropathy and autonomic dysfunction after HPV vaccination in Korea.

Damage Characteristics of Rocks by Uniaxial Compression and Cyclic Loading-Unloading Test (일축압축시험과 반복재하시험을 이용한 암석의 손상특성 분석)

  • Jeong, Gyn-Young;Jang, Hyun-Sic;Jang, Bo-An
    • The Journal of Engineering Geology
    • /
    • v.31 no.2
    • /
    • pp.149-163
    • /
    • 2021
  • Damage characteristics of granite, marble and sandstone whose properties were different were investigated by uniaxial compression test and cyclic loading-unloading test. Strength, elastic constants and damage threshold stresses were measured by uniaxial compression test and were compared with those measured by cyclic loading-unloading test. Average rock strengths measured by cyclic loading-unloading test were either lower than or similar with those measured by uniaxial compression test. Rocks with high strength and low porosity were more sensitive to fatigue than that with low strength and high porosity. Although permanent strains caused by cyclic loading-unloading were different according to rock types, they could be good indicators representing damage characteristics of rock. Damage threshold stress of granite and marble might be measured from stress-permanent strain curves. Acoustic emissions were measured during both tests and felicity ratios which represented damage characteristics of rocks were calculated. Felicity ratio of sandstone which was weak in strength and highly porous could not be calculated because of very few measurements of acoustic emissions. On the other hand, damage threshold could be predicted from felicity ratios of granite and marble which were brittle and low in porosity. The deformation behaviors and damage characteristics of rock mass could be investigated if additional tests for various rock types were performed.

Development of automatic inspection system of defects on inner surface of pneumatic cylinder-tubes by electronic endoscope (전자내시경을 활용한 공압실린더 튜브 내면의 결함 자동검사시스템 개발)

  • Lho, Tae-Jung;Koo, Bon-Joo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3376-3382
    • /
    • 2014
  • The system developed inspects automatically defects existing on an inner surface of anodically treated aluminum cylinder-tubes. This system consists of automatic inspection software, and electronic endoscope and a conveyor moving device. By applying the optimal brightness conditions to searching for various defects on the inner surface of cylinder tube, the recognition rate of major defects, such as scratch, oxide and weld line reached 99%. If the present visual inspection process is replaced with the automatic defects inspection system, the physical fatigue of the operator could be reduced and the productivity could be increased. The automatic inspection system developed could also improve the quality of the products.

Realization of Torsional Response based on Multi-mass Modeling of Turbine-Generator Shaft System (터빈 발전기 축 시스템의 다중 질량체 모델링을 통한 비틀림 응답 구현)

  • Park, Ji-Kyung;Cho, Gyu-Jung;Sohn, Seung-Hyun;Chung, Se-Jin;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.201-207
    • /
    • 2015
  • Turbine-generator torsional response is caused by interaction between electrical transient air-gap torque and mechanical characteristics of turbine-generator shafts. If torsional shaft torque exceeds a certain threshold, the loss of fatigue life may occur and, in the end, it is possible to happen permanent shaft failure. Therefore, it is required to understand the torsional response for reliable operation and protection of turbine-generator shaft system. In this paper, we introduced multi-mass modeling method of turbine-generator shaft system using mechanical-electrical analogy and state-space equation to verify the transient torsional response based on ElectroMagnetic Transient Program (EMTP). These simple realization methods for turbine-generator shaft torsional response could be helpful to understand torsional interaction phenomena and develop the transient torque reduction countermeasures for turbine-generator shaft system.