• Title/Summary/Keyword: Fast Fourier transformation

Search Result 97, Processing Time 0.033 seconds

Age-related Changes of the Finger Photoplethysmogram in Frequency Domain Analysis (연령증가에 따른 지첨용적맥파의 주파수 영역에서의 변화)

  • Nam, Tong-Hyun;Park, Young-Bae;Park, Young-Jae;Shin, Sang-Hoon
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.12 no.1
    • /
    • pp.42-62
    • /
    • 2008
  • Objectives: It is well known that some parameters of the photoplethysmogram (PPG) acquired by time domain contour analysis can be used as markers of vascular aging. But the previous studies that have been performed for frequency domain analysis of the PPG to date have provided only restrictive and fragmentary information. The aim of the present investigation was to determine whether the harmonics extracted from the PPG using a fast Fourier transformation could be used as an index of vascular aging. Methods: The PPG was measured in 600 recruited subjects for 30 second durations, To grasp the gross age-related change of the PPG waveform, we grouped subjects according to gender and age and averaged the PPG signal of one pulse cycle. To calculate the conventional indices of vascular aging, we selected the 5-6 cycles of pulse that the baseline was relatively stable and then acquired the coordinates of the inflection points. For the frequency domain analysis we performed a power spectral analysis on the PPG signals for 30 seconds using a fast Fourier transformation and dissociated the harmonic components from the PPG signals. Results: A final number of 390 subjects (174 males and 216 females) were included in the statistical analysis. The normalized power of the harmonics decreased with age and on a logarithmic scale reduction of the normalized power in the third (r=-0.492, P<0.0001), fourth (r=-0.621, P<0.0001) and fifth harmonic (r=-0.487, P<0.0001) was prominent. From a multiple linear regression analysis, Stiffness index, reflection index and corrected up-stroke time influenced the normalized power of the harmonics on a logarithmic scale. Conclusions: The normalized harmonic power decreased with age in healthy subjects and may be less error prone due to the essential attributes of frequency domain analysis. Therefore, we expect that the normalized harmonic power density can be useful as a vascular aging marker.

  • PDF

A Study of Muscle Fatigue in Lumbar and Abdominal Muscles in Patients with Chronic Low Back Pain by Electromyographic Power Spectral Analysis (근전도 스펙트럼 분석을 이용한 만성 요통 환자의 요부근육과 복부근육의 피로도 분석)

  • Nam, Ki-Seok;Lee, Young-Hee;Yi, Chung-Hwi;Cho, Sang-Hyun
    • Physical Therapy Korea
    • /
    • v.6 no.2
    • /
    • pp.16-31
    • /
    • 1999
  • The purpose of this study was to assess the fatigue in lumbar and abdominal muscles in patients with chronic low back pain compared with normal subjects using spectral analysis with mean power frequency and median power frequency. The experimental group consisted of twenty subjects who had experienced chronic low back pain for over one year after the onset day. A control group consisted of twenty normal subjects with no history of low back pain. All subjects stood in an apparatus to perform sustained contraction in the lumbar and abdominal muscles for 30 seconds with 60% maximal voluntary isometric contraction (MVIC). The resulting electromyographic (EMG) recorded time serial data were transformed into frequency serial data by Fast Fourier Transformation (FFT). The results were as follows: 1) lumbar muscles measured, the frequency change ratio of both median power frequency and mean power frequency was significantly greater for experimental group compared with control group group (p<0.05). In measured two abdominal muscles (inferior rectus abdominis, obliquus externus abdominis) except superior rectus abdominis, the frequency change ratio of both median power frequency and mean power frequency was significantly greater for experimental group compared with control group (p<0.05). 2) In all three (longissimus thoracis, iliocostalis lumborum, multifidus) lumbar muscles measured, the initial frequency value of both median power frequency and mean power frequency was significantly lower for the experimental group compared with the control group (p<0.05). In the two (inferior rectus abdominis, obliquus externus abdominis) abdominal muscles measured (superior rectus abdominis not included), the initial frequency value of both median power frequency and mean power frequency was significantly lower for the experimental group compared with the control group (p<0.05). These results suggest that in patients with chronic low back pain there is a trend for more fatigue to occur in both lumbar and abdominal muscles than in the normal control group. This would seem to suggest that in treatment programs for patients with chronic low back pain, improvement of endurance in all trunk muscles should be considered.

  • PDF

Surface Elevation Recovery Methods from Pressure Gage for Irregular Waves (불규칙파(不規則波에) 대한 압력식(壓力式) 파고계(波高計)의 적용성(適用性)에 관한 연구(研究))

  • Kwon, Jung Gon;Kang, Ju Bok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.4_1
    • /
    • pp.129-136
    • /
    • 1992
  • A precedure for recovering surface displacement from a time series of pressure measured by a pressure gage in a shallow water (that is, FFTM, LCM. IWM) is investigated with respect to a proper cut-off-frequency of a frequency response function for the accurate recovery of wave height and period. The authors examined the applicability of above mentioned three transformation procedures through field observations and laboratory experiments and the following results are obtained. i) The cut-off-frequency of the frequency response function used in FFTM is deeply depend on both the frequency response of the pressure sensor and the water depth at the sensor. In this study, a relatively accurate surface displacement can be recovered when the frequency response function is cut off at the frequency corresponding to kh=3.0 where k is a wave number at the depth of h. The frequency response function in the region higher than the cut-off-frequency is set constant to be the value at the cut-off-frequency. ii) The transformed surface displacements by LCM are affected by the small waves of short periods included in the measured pressure. It is found that pressure variation whose local frequency is higher than kh=1.5 has to be neglected to recover surface displacement sufficiently. iii) In IWM, the linear pressure response function is usually utilized by multiplying a coefficient N which is a function of the frequency (or kh) and takes a value around unity. However, in this study, a constant value of N(=1.0) gives a relatively accurate recovery of surface displacements.

  • PDF

Influence of the Knee Angles on the Electromyographic Activites and Fatigue of the Ankle Muscles in Healthy Subjects (무릎관절 각도가 발목 근육의 근전도 활동에 미치는 영향)

  • Yu, Gyeong-Seok;Kim, Taek-Yean
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.12 no.1
    • /
    • pp.16-26
    • /
    • 2006
  • The purpose of this study was to investigate the influence of the various knee angles and ground state on the muscular activities and fatigue of the ankle muscles by integrated electromyograms (iEMG) and median frequency of tibialis anterior (TA), peroneus longus (PL), flexor digitorum longus (FDL) and gastrocnemius (GC). Ten healthy male subjects were participated into stable and balance ball sessions at four angles of knee joint. The surface electromyograms (sEMG) were recorded from the TA, PL, FDL and GC on stable and balance ball with full weight bearing at four knee angles of $0^{\circ}$, $15^{\circ}$, $30^{\circ}$ and $45^{\circ}$. The time serial data of the surface electromyographic signals were transformed into integrated and frequency serial data by fast fourier transformation. On the stable ground, the iEMG signals of the TA, PL, FDL and GC were significantly higher at $45^{\circ}$ and $30^{\circ}$ of knee angles than $0^{\circ}$ and $15^{\circ}$ of knee flexion (p<0.05). On the balance ball, the iEMG of the TA, PL, FDL and GC were significantly higher at $45^{\circ}$ and $30^{\circ}$ of knee angles than $0^{\circ}$ and $15^{\circ}$ of knee flexion (p<0.05). The median frequency of the TA, PL, FDL and GC were significantly lower at $45^{\circ}$ and $30^{\circ}$ of knee angles than $0^{\circ}$ and $15^{\circ}$ of knee on the stable ground (p<0.05). On the balance ball, also the median frequency of the TA, PL, FDL and GC were significantly lower at $45^{\circ}$ and $30^{\circ}$ of knee angles than $0^{\circ}$ and $15^{\circ}$ of knee flexion (p<0.05). The iEMG of the TA, PL, FDL and GC were significantly higher on the balance ball at $0^{\circ}$, $15^{\circ}$, $30^{\circ}$ and $45^{\circ}$ of knee angles compared with stable ground. The median frequency of the TA, PL, FDL and GC were significantly lower on the balance ball at $0^{\circ}$, $15^{\circ}$, $30^{\circ}$ and $45^{\circ}$ of knee angles compared with stable ground. These results indicate that the ground conditions and angles of the knee joint involved to muscular activities and fatigue of ankles muscles, may performed at first on stable ground and then balance ball in order to $0^{\circ}$, $15^{\circ}$, $30^{\circ}$ and $45^{\circ}$ of knee flexion.

  • PDF

Analysis and Measurement of the Magnetic Fields Cause by Operation of Electromotive Installations (전동력설비의 운전에 의해 발생되는 자계의 측정과 해석)

  • 이복희;길경석
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.2
    • /
    • pp.58-67
    • /
    • 1995
  • The paper describes the variation of magnetic fields caused by the operation of induction motors. The measuring system consists of the self-integrating magnetic field sensor, amplifier, and active integrator. From the calibration experiments, the frequency bandwidth of the magnetic field measuring system ranges from 20[Hz] to 300[kHz] and sensitivity is 0.234(mV/$\mu\textrm{T}$]. The magnetic fields generated under steady state and starting operations of duction motor are recorded by the proposed measuring system, and the fast Fourier transformation(FFT) of the measured data is performed to analyze the harmonic components. A single pulsed magnetic field is strongly caused by direct starting the induction motor, and its peak value is greater than 5 times as compared with the steady state value. The long transient duration and high intensity originates from the large inductance and dynamic characteristic of the induction motor, During the steady state operation of induction motor, subharmonics of magnetic field components, which depend on the pole number of induction motor, are observed. The lower order power-line harmonics can be inferred from the voltage flicker and current ripple which are derived from the torque fluctuation of induction motor. In the case of the induction motor drived by inverter, the harmonics of magnetic field are much more than those caused by direct starting method and are found generally to increase with decreasing the driving frequency.

  • PDF

A Study on the Stability Fatigue according to the Accommodation Change due to the Use of Smartphone (스마트폰의 사용으로 인한 조절 변화에 따른 안정피로도에 대한 연구)

  • Kim, Bong-Hwan;Han, Sun-Hee;Park, Seon-Mi;Bae, Sang-Bin;Woo, Yong-Jun;Song, Gyeong-Jun;Bang, Eun-Min;Seo, Da-Eun
    • Journal of Korean Clinical Health Science
    • /
    • v.8 no.1
    • /
    • pp.1362-1368
    • /
    • 2020
  • Purpose. In this study, The change of the accommodation function due to the use of a smartphone was objectively evaluated using an Auto Refractokeratometer and was to investigate the effect of accommodation response and microfluctuations of accommodation on stable fatigue. Methods. Twenty subjects (20 males, 20 females) who had no abnormalities in ophthalmic disease and strabismus, diplopia, suppression, convergence and ocular movement, and corrected visual acuity and unaided visual acuity of 0.8 or more were performed. The average age of the participants is (21.78 ± 1.78) years old. The refractive power of the eye was measured using an Auto Refractokeratometer (Speedy-i K-model, Righton Mfg Co. Tokyo Japan), and the equivalent spherical power was automatically calculated from the measured refractive power. The accommodation response amount was calculated for the accommodation stimulation amount in 8 steps in 0.5D increments from + 0.50D to -3.00D in the calculated equivalent spherical power. The microfluctuations of accommodation in the high frequency region was calculated according to the change in the amount of the accommodation stimulus. At this time, the spectral power of the microfluctuations of accommodation was analyzed by Fast Fourier Transformation (FFT). Results. After using the smartphone, it was found that the accommodation response to accommodation stimulation decreased and the microfluctuations of accommodation increased. Conclusions. It can be said that the use of a smartphone affects the accommodation response and the microfluctuations of accommodation, thereby causing a accommodative stable fatigue. Therefore, it is thought that the use of a smartphone for a long time may bring about a change in the accommodation function.

A Study on Geoid Model Development Method in Philipphines (필리핀 지오이드모델의 개발방안 연구)

  • Lee, Suk-Bae;Pena, Bonifasio Dela
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.6
    • /
    • pp.699-710
    • /
    • 2009
  • If a country has her geoid model, it could be determine accurate orthometric height because the geoid model could provide continuous equi-gravity potential surface. And it is possible to improve the coordinates accuracy of national control points through geodetic network adjustment considering geoidal heights. This study aims to find the best way to develop geoid model in Philippines which have similar topographic conditions as like Malaysia and Indonesia in Eastsouth asia. So, in this study, it is surveyed the general theories of geoid determination and development cases of geoid model in Asia and it is computed that the geoidal heights and gravity anomalies by spherical harmonic analysis using EGM2008, the latest earth geopotential model. The results show that first, the development of gravimetric geoid model based on airborne gravimetry is needed and second, about 200 GPS surveying data at national benchmark is needed. It is concluded that it is the most reasonable way to develop the hybrid geoid model through fitting geometric geoid by GPS/leveling data to gravimetric geoid. Also, it is proposed that four band spherical Fast fourier transformation(FFT) method for evaluation of Stokes integration and remove and restore technique using EGM2008 and SRTM for calculation of gravimetric geoid model and least square collocation algorithm for calculation of hybrid geoid model.