• Title/Summary/Keyword: Fan-in-body

Search Result 89, Processing Time 0.028 seconds

Nanostructural Study of Apatite Film Biomimetically Grown in SBF (Simulated Body Fluid) (생체유사환경에서 성장된 아파타이트 층의 나노구조 연구)

  • Kim, Joung;Lee, Kap-Ho;Hong, Sun-Ig
    • Korean Journal of Materials Research
    • /
    • v.15 no.11
    • /
    • pp.690-696
    • /
    • 2005
  • The ultrastructure ore of a nanostructured apatite film nucleated from solution was studied to gain insights into that of bone minerals which is the most important constituent to sustain the strength of bones. Needle-shaped apatite crystal plates with a bimodal size distribution $(\~100\;to\;\~1000 nm)$ were randomly distributed and they were found to grow parallel to the c-axis ([002]), driven by the reduction of surface energy. Between these randomly distributed needle-shaped apatite crystals which are parallel to the film, apatite crystals (20-40nm) with the normal of the grains quasi-perpendicular to the c-axis were observed. These observations suggest that the apatite film is the interwoven structure of apatite crystals with the c-axis parallel and quasi-perpendicular to the fan. In some regions, amorphous calcium phosphate, which is a precursor of apatite, was also observed. In the amorphous phase, small crystalline particle with the size of 2-3 nm were observed. These particles were quite similar, in size and shape, to those observed in the femoral trabecular bone, suggesting the nucleation of apatites by a biomimetic process in vitro is similar to that in vivo.

Low Speed Wind Tunnel Testing to Measure Drag with Velocity Variation on a Cube Body

  • Rahmanto, R. Hengki;Choe, Gwang-Hwan;Go, Dong-Gyun
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.96-102
    • /
    • 2008
  • For centuries now, wind tunnels have been a key element in scientific research in a number of fields. Experimenting with racecars, airplanes, weather patterns, birds, and various other areas has been made much easier because of its development. In the racing field, for example, the information gathered from this testing can mean the difference between winning and losing a race. Weather simulations can also provide valuable information regarding building stability and safety. This has become very important when designing buildings today. Valuable information concerning bird flight has also been collected based on wind tunnel testing. Wind tunnels have a variety of important uses in the world today. Wind tunnel that used here is an open loop low speed wind tunnel. The fundamental principles of this tunnel is moving the air using exhaust fan In the rear side, and placing the cube in the external balance system which used to measure the working force. This experiment is using 50mm cube of finished wood. From this experiment we can get Drag Force (FD), The Reynolds Number (Re) and The Coefficient of Brae (CD).

  • PDF

The application of Large Eddy Simulation in designing the impellers of double-flow-conduits-sewage pump

  • Xue-y QI;Zai-lun Liu;chonl QI;Fan-zhon MENG
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.200-202
    • /
    • 2003
  • In this paper, Gauss filter function is used to filter the N-S equation and the subgrid-scale Reynold stresses model is introduced to deduce the practical form of LES equation for 2-D case for flow calculation of hydraulic machine. Then the LES equation and its discrete form in computational field are obtained in the body-fitted coordinate system and the numerical calculation program is built. The incompressible turbulent flow in double-flow-conduits-sewage pump impeller is computed by using the abovementioned program, and then the distribution rules of velocity and pressure in flow field are obtained. Based on this, the designs of double-flow-conduits-sewage pump impeller are optimized.

  • PDF

Comparison of Form Factors of Liver in ZangFu Diagrams (臟腑圖) before Northern Song Ages and Ones Originated from MingTangZangFuTu (明堂臟腑圖) (북송(北宋) 이전 장부도(臟腑圖)와 명당장부도(明堂臟腑圖)에서 기원한 장부도(臟腑圖)에 나타난 간장(肝臟)의 형태요소의 비교)

  • Jo, Hak-Jun
    • The Journal of Korean Medical History
    • /
    • v.29 no.2
    • /
    • pp.17-33
    • /
    • 2016
  • Objectives : The goal of this paper is to verify the hypothesis that the diagrams of liver from MingTangZangFuTu (明堂臟腑圖) were derived from ZangFu diagrams (臟腑圖) before northern Song Ages. Methods : The difference of form of liver was analyzed by means of 4 factors, e.g. shape, number, veins and a petiole of leafs, in diagrams from YanLuoZiNeiJingTu [煙蘿子內境圖], OuXiFanWuZangTu [歐希範五臟圖], CunZhenTu [存眞圖], MingTangZangFuTu and ones of liver from Taoism and MingTangZangFuTu. Results : Diagrams of whole body and liver from MingTangZangFuTu were first found in ZhenJiuJuYing (鍼灸聚英). Among them, lobed shape was first found in YanLuoZiNeiJingTu (in Wudai [五代]), a petiole in OuXiFanWuZangTu (northern Song Ages) and 7 leafs in WuZangLiuFuTu (五臟六腑圖. from Tang (唐) Ages to early northern Song Ages. unknown author.), one of references of UiBangNyuChwi (醫方類聚) (1455). However, veins of leafs were drawn in no diagrams. Conclusions : In diagrams of liver from MingTangZangFuTu, shape and a petiole of leafs were based on diagrams of ZangFu before northern Song Ages, but 7 leafs came from WuZangLiuFuTu. However, veins of leafs were not derived from any diagrams in same period.

The Study of New Reconstruction Method for Brain SPECT on Dual Detector System (Dual detector system에서 Brain SPECT의 new reconstruction method의 연구)

  • Lee, Hyung-Jin;Kim, Su-Mi;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.57-62
    • /
    • 2009
  • Purpose: Brain SPECT study is more sensitive to motion than other studies. Especially, when applying 1-day subtraction method for Diamox SPECT, it needs shorter study time in order to prevent reexamination. We were required to have new study condition and analysing method on dual detector system because triple head camera in Seoul National University Hospital is to be disposed. So we have tried to increase image quality and make the dual and triple head to have equivalent study time by using a new analysing program. Materials and Methods: Using IEC phantom, we estimated contrast, SNR and FWHM. In Hoffman 3D brain phantom which is similar with real brain, we were on the supposition that 5% of injected doses were distributed in brain tissue. To compare with existing FBP method, we used fan-beam collimator. And we applied 15 sec, 25 sec/frame for each SEPCT studies using LEHR and LEUHR. We used OSEM2D and Onco-flash3D reconstruction method and compared reconstruction methods between applied Gaussian post-filtering 5mm and not applied as well. Attenuation correction was applied by manual method. And we did Brain SPECT to patient injected 15 mCi of $^{99m}Tc$-HMPAO according to results of Phantom study. Lastly, technologist, MD, PhD estimated the results. Results: The study shows that reconstruction method by Flash3D is better than exiting FBP and OSEM2D when studied using IEC phantom. Flowing by estimation, when using Flash3D, both of 15 sec and 25 sec are needed postfiltering 5 mm. And 8 times are proper for subset 8 iteration in Flash3D. OSEM2D needs post-filtering. And it is proper that subset 4, iteration 8 times for 15sec and subset 8, iteration 12 times for 25sec. The study regarding to injected doses for a patient and study time, combination of input parameter-15 sec/frame, LEHR collimator, analysing program-Flash3D, subset 8, iteration 8times and Gaussian post-filtering 5mm is the most appropriate. On the other hands, it was not appropriate to apply LEUHR collimator to 1-day subtraction method of Diamox study because of lower sensitivity. Conclusions: We could prove that there was also an advantage of short study time effectiveness in Dual camera same as Triple gamma camera and get great result of alternation from existing fan-beam collimator to parallel collimator. In addition, resolution and contrast of new method was better than FBP method. And it could improve sensitivity and accuracy of image because lesser subjectivity was input than Metz filter of FBP. We expect better image quality and shorter study time of Brain SPECT on Dual detector system.

  • PDF

Performance Assessment of Turbulence Models for the Prediction of Tip Leakage Flow in an Axial-flow Turbomachinery (축류형 유체 기계에서 팁 누설 유동 해석을 위한 난류 모델 성능 비교)

  • Lee, Gong-Hee;Baek, Je-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2162-2167
    • /
    • 2003
  • It is well-known that high anisotropic characteristic of turbulent flow field is dominant inside tip leakage vortex. This anisotropic nature of turbulence invalidates the use of the conventional isotropic eddy viscosity turbulence model based on the Boussinesq assumption. In this study, to check whether an anisotropic turbulence model is superior to the isotropic ones or not, the results obtained from steady-state Reynolds averaged Navier-Stokes simulations based on the RNG ${\kappa}-{\varepsilon}$ and the Reynolds stress model in two test cases, such as a linear compressor cascade and a forward-swept axial-flow fan, are compared with experimental data. Through the comparative study of turbulence models, it is clearly shown that the Reynolds stress model, which can express the production term and body-force term induced by system rotation without any modeling, should be used to predict the complex tip leakage flow, including the locus of tip leakage vortex center, quantitatively.

  • PDF

Application of medium-voltage drive to motor equipment of 800MW gas power plant. (800MW 가스발전소의 모터 설비에 고압 드라이브를 적용한 사례)

  • Kim, Kyoungsue;Oh, Hyunseok;Park, Jongje;Jeon, Jaehyun;Park, Cheolhyun
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.424-425
    • /
    • 2018
  • In the introduction, this paper introduces LS Industrial Systems' medium-voltage drive installed at Hyundai Green Power, an 800MW gas power plant. In the body, it explains the synchronous transfer technology and new speed search technology applied to Forced Draft(FD) Fan and Boiler Feed-water(BF) Pump, which are power generation facilities. Lastly, it shows the annual energy saving amount and operation status which are applied to each facility and proves that it is a successful application case.

  • PDF

Effect of Genotype on Whole-body and Intestinal Metabolic Response to Monensin in Mice

  • Fan, Y.K.;Croom, W.J.;Daniel, Linda;McBride, B.W.;Koci, M.;Havenstein, G.B.;Eisen, E.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.19 no.4
    • /
    • pp.554-562
    • /
    • 2006
  • Two lines of mice, M16 selected for rapid growth and a randomly selected control ICR as well as their reciprocal crosses were used to study the effects of genotype on whole-body energetics and intestinal responses to monensin. Six mice, eight weeks of age, from each line or reciprocal cross were assigned to one of two treatments, 1) drinking water containing 20 mmol/L monensin dissolved in 0.5% V/V ethanol, and 2) drinking water containing 0.5% V/V ethanol (control) for two weeks. After 11 days (age of 9 weeks and 4 days), whole-body $O_2$ consumption was measured. At the end of two weeks, jejunal $O_2$ consumption, intestinal tissue composition and histomorphometrics as well as the rate and efficiency of glucose absorption were estimated. In comparison with the control, monensin administration in drinking water resulted in less daily water intake (13.4 vs. 15.5 ml/mouse, p<0.01), less protein to DNA ratio of jejunal mucosa (5.41 vs. 6.01 mg/mg, p<0.05), lower villus width (88 vs. $100{\mu}m$, p<0.05), and less jejunal tissue $O_2$ consumption enhancement by alcohol (7.2 vs. 10.5%, p<0.01) in mice. Other than those changes, monensin had little (p>0.05) effect on variables measured in either line of mice or their reciprocal cross. In contrast, the M16 line, selected for rapid growth, as compared to the ICR controls or the reciprocal crosses, had less initial (pre-monensin treatment) whole-body $O_2$ consumption per gram of body weight (1.68 vs. $2.11-2.34{\mu}mol/min{\cdot}g$ BW, p<0.01) as compared to the ICR and reciprocal crosses. In addition, the M16 mice exhibited greater growth (412 vs. 137-210 mg/d, p<0.05), better feed efficiency (41.7 vs. 19.9-29.3 mg gain/g feed, p<0.05), shorter small intestines adjusted for fasted body weight (1.00 vs. 1.22-1.44 cm/g FBW, p<0.05), wider villi (109 vs. $87-93{\mu}m$, p<0.05), more mature height of enterocytes (28.8 vs. $24.4-25.1{\mu}m$, p<0.05) and a lower rate (91 vs. $133-145{\eta}mol\;glucose/min{\cdot}g$ jejunum, p<0.05) and less energetic efficiency (95 vs. $59-72{\eta}mol$ ATP expended/${\eta}mol$ glucose uptake, p<0.05) of glucose absorption compared to the ICR line and the reciprocal cross. Monensin had little (p>0.05) effect on whole-body $O_2$ consumption and jejunal function, whilst selection for rapid growth resulted in an apparent down-regulation of intestinal function. These data suggest that genetic selection for increased growth does not result in concomitant changes in intestinal function. This asynchrony in the selection for production traits and intestinal function may hinder full phenotypic expression of genotypic growth potential.

Liquid Crystal Droplet Patterns to Monitor Catalase Activity at Femtomolar Levels

  • Yoon, Stephanie;Jang, Chang-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.9
    • /
    • pp.2704-2710
    • /
    • 2014
  • Catalase (CAT) decomposes hydrogen peroxide that is toxic to the body. In this study, simple and sensitive detector has been developed for observing catalase activity using liquid crystal droplet system. Microscale LC droplet patterns are formed by spreading aldehyde-doped nematic liquid crystal on pre-treated glass slides. When hydrogen peroxide is added, aldehyde is oxidized and amphiphiles are formed. Dodecanoates cause the pattern to transit from bright to dark as they self-assemble to form a carboxyalte monolayer at the interface. When a drop of pre-incubated CAT and hydrogen peroxide mixture is placed onto the pattern, bright fan-shape is observed. This planar optical appearance indicates that catalase has decomposed hydrogen peroxide. Compared to the detectors that have been previously developed, this system is more sensitive with detection limit of 1fM. This research suggests further studies to be on LC droplet patterning to develop highly sensitive and methodologically simple sensors for various chemicals.

Low Noise Vacuum Cleaner Design (저소음 청소기 개발)

  • Joo, Jae-Man;Lee, Jun-Hwa;Hong, Seun-Gee;Oh, Jang-Keun;Song, Hwa-Gyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.939-942
    • /
    • 2007
  • Vacuum cleaner is a close life product that can remove various dusts from our surroundings. However well vacuum cleaner clean our environments, many people are looking away from it, due to its loud noise. Its noise causes a big trouble in the usual life, for example, catch calls, TV watching and discussing etc. To reduce these inconveniences, noise reduction methods and systematic design of low noise vacuum cleaner are studied in this paper. At first, sound quality investigation is performed to get the noise level and quality that make people TV watching and catch calls available. Based on the European and domestic customer SQ survey result, sound power, peak noise level and target sound spectrum guideline are studied and introduced. As a second, precise product sound spectrums are designed into each part based on the sound quality result. Fan-motor, brush, mainbody, cyclone spectrums are decided to get the final target sound based on the contribution level. Fan-motor is the major noise source of vacuum cleaner. Specially, its peak sound, RPM peak and BPF Peak, cause the people nervous. To reduce these peak sounds, high rotating impeller and diffuser are focused due to its interaction. A lot of experimental and numerical tests, operation points are investigated and optimization of flow path area between diffusers is performed. As a bagless device, cyclones are one of the major noise sources of vacuum cleaner. To reduce its noise, previous research is used and adopted well. Brush is the most difficult part to reduce noise. Its noise sources are all comes from aero-acoustic phenomena. Numerical analysis helps the understanding of flow structure and pattern, and a lot of experimental test are performed to reduce the noise. Gaps between the carpet and brush are optimized and flow paths are re-designed to lower the noise. Reduction is performed with keeping the cleaning efficiency and handling power together and much reduction of noise is acquired. With all above parts, main-body design is studied. To do a systematic design, configuration design developments technique is introduced from airplane design and evolved with each component design. As a first configuration, fan-motor installation position is investigated and 10 configuration ideas are developed and tested. As a second step, reduced size and compressed configuration candidates are tested and evaluated by a lot of major factor. Noise, power, mass production availability, size, flow path are evaluated together. If noise reduction configuration results in other performance degrade, the noise reduction configuration is ineffective. As a third configuration, cyclones are introduced and the size is reduced one more time and fourth, fifth, sixth, seventh configuration are evolved with size and design image with noise and other performance indexes. Finally we can get a overall much noise level reduction configuration. All above investigations are adopted into vacuum cleaner design and final customer satisfaction tests in Europe are performed. 1st grade sound quality and lowest noise level of bagless vacuum cleaner are achieved.

  • PDF