• Title/Summary/Keyword: Fan speed

Search Result 316, Processing Time 0.024 seconds

The Analysis of Vibration characteristics for Vacuum Cleaner Fan Motor Using 3-D Laser Vibrator (3차원 레이저 진동 측정기를 이용한 초고속 진공청소기 모터의 진동특성분석)

  • 김재열;김우진;심재기;김영석
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.399-405
    • /
    • 2004
  • Recently technology resulted in highly efficient and multiple-functional electric appliances considering environmental problems. One of the environmental problems is noise of a product in respect to its function. A vacuum cleaner is an essential electric appliance in our daily lives. However, severe noise resulted from high motor speed for improving the function of the appliance is a nuisance for the user. This noise is caused by vibration from various parts of the appliance and fluid noise during a series of intake and exhaust processes while rotating the impeller connected to the axle at a high speed of the fan motor inside the vacuum cleaner rotating around 30,000-35,000 rpm. Despite the fact that many researchers conducted studies on reducing the noise level of the fan motor in a vacuum cleaner, only few studies have been conducted considering both the theoretical and experimental aspects using fluid analysis by measuring vibration and noise. Moreover, there has not been a study that accurately compared major noise data obtained considering both of the aspects. In this study, both aspects were considered by considering the following experimental and theoretical methods to verify the major causes of noise from the fan motor in a vacuum cleaner.

  • PDF

A Study on the Development of the Engine Room Fan Control System and ERFCS Algorithm for Ships Energy Saving (선박 에너지 절감을 위한 기관실 팬 제어 시스템 구축 및 알고리즘에 관한 연구)

  • Kang, Young-Min;Oh, Jin-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.6
    • /
    • pp.642-648
    • /
    • 2015
  • Recently, there have been many studies pertaining to reducing energy consumption on ships. As part of those studies, the energy consumption of ships can be reduced by understanding and controlling the varying loads, excluding fixed loads. In existing ships, engine room fans are usually operated based on the actual experience of the crew without any special guidelines. To realize energy reduction, we investigate the characteristics of engine-room fans, and we propose an energy-management system called the engine room fan control system (ERFCS) and the ERFCS algorithm. The ERFCS controls the fan speed depending on the temperature and pressure, where one to four fans are operated depending on changes in the load. In addition, the minimum rotation speed of the engine-room fan was limited to 50% to prevent the surging phenomenon, which is due to fan damage or low pressure resulting from mechanical friction or heating at low fan speeds. We develop a fan control system simulation model using LabVIEW that is based on the proposed algorithm and ISO 8861. Finally, we perform simulations to confirm that operation of the proposed fan control system is possible using only 46.4% of the power required by the existing method.

헬리콥터용 반토오크 시스템 1차 시제 성능시험

  • Song, Keun-Woong;Kang, Hee-Jung;Sim, Joung-Wook;Lee, Je-Dong;Kim, Seung-Bum
    • Aerospace Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.50-59
    • /
    • 2005
  • This paper described performance test of 1st prototype "Tail-Fan" system. KARI(Korea Aerospace Research Institute) developed "Tail-Fan" system as a kind of helicopter anti-torque system(ATS) and designed ATS performance test-rig for Tail-Fan system performance test. For Tail-Fan system performance tests, firstly, test-rig operation tests were carried out for verification of design specifications. And natural frequencies of fan blade and test-rig were measured respectively. To find the operation rotating speed for performance tests, vibration tests using accelerometers on tail gear box(TGB) were carried out. Through the fanplot and vibration test results, rotational speed for Tail-Fan performance test to avoid a resonance were found and performance tests were carried out in flight conditions. We analyzed test data by non-dimensionalization. Through this results, 1st prototype "Tail-Fan" system was satisfied with design requirements.

  • PDF

Size Distribution of Droplets Sprayed by an Orchard Sprayer (과수방제기 살포입자의 직경 분포특성)

  • 구영모;신범수;김상헌
    • Journal of Biosystems Engineering
    • /
    • v.26 no.5
    • /
    • pp.431-440
    • /
    • 2001
  • Generated agri-chemical droplets by orchard sprayers are evaporated regenerated and transported along wind streams. The droplets are deposited to targets after changing their sizes, affecting the retention of droplets. An orchard sprayer, designed for spraying grapevines was studied on the spatial distribution of droplet size. The experimental variables were spray direction (0, 22.5, 45, 67.5 and 90˚), distance(2.5, 3.0 and 3.5 m) and fan speed (2,075 and 3,031 rpm). Droplet sizes were converted and analyzed from spray stains, sampled using water sensitive papers. The number median diameter (NMD) increased with an increase of the distance due to disappeared fine droplets (<50 ㎛): however, the volume median diameter (VMD) decreased due to shrunken large droplets (>100 ㎛). Fast fan speed delivered large droplets to 3.5 m, but the spatial distributions of NMD and VMD were not uniform. Slower fan speed decreased the possibility of evaporation and drift; therefore, plenty of droplets were maintained up to 3.0 m. The upward blasting distance was limited within 3 m, but the limit to the ground level was extended to 3.5 m. Concentrated wind and droplets to the ground level should be redistributed to upper canopy direction, leading more uniform deposits. High speed wind and system pressure should be avoided because of generating fine droplets, which would be disappeared and drifted away.

  • PDF

Development of High-performance/low-noise Centrifugal Fan Circulating Cold Air Inside a Household Refrigerator by Reduction of Vortex Flow (와류 저감을 통한 냉장고 냉기순환용 고성능/저소음 원심홴의 개발)

  • Shin, Donghui;Ryu, Seo-Yoon;Cheong, Cheolung;Kim, Tae-Hoon;Jung, Jiwon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.4
    • /
    • pp.428-435
    • /
    • 2016
  • In this paper, high-performance and low-noise centrifugal fan used to circulate cold air inside a household refrigerator is developed by reducing the vortex flow observed near the tip of fan hub. First, the performance of the existing centrifugal fan is investigated through the experiment using a fan tester and the characteristics of detailed flow field obtained from the CFD simulation are closely examined. The strong vortex flow is observed in the vicinity of the tip of fan hub. Based on this result, new design is devised to reduce this vortex flow. As a result, it is numerically and experimentaly found that the volume flow rate of the new fan increases and the radiated noise decreases in comparison with the existing fan at the same rotation speed.

Analysis of fan clutch characteristics for electronic engine cooling control system (전자식 엔진냉각제어 시스템을 위한 팬 클러치 특성 분석)

  • Ryu, Hye-Yeon;Kim, Hyun-Hee;Jeong, Sung-Min;Koh, Young-Ho;Lee, Kyung-Chang
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.5
    • /
    • pp.241-246
    • /
    • 2018
  • The engine cooling system is a device that keeps the temperature of the engine room at a proper level by driving the cooling fan when the engine room temperature that occurs during driving is above a certain temperature. Recently, the vehicle cooling system has been changed to electronic system. Therefore, in this paper, we will analyze the clutch operation characteristics for designing a superior electronic fan clutch. For this purpose, an electronic fan clutch was designed and a test bed for performance evaluation was constructed and analyzed.

Pigment Distribution Analysis of High Speed Fan for Dusting Large Pasture at Livestock Farms (축산농가를 위한 대규모 목초지 방제용 고속 팬의 실험을 통한 색소 분포에 따른 분석)

  • Kim, C.S.;Min, B.R.;Seo, K.W.;Lee, D.W.
    • Journal of Animal Environmental Science
    • /
    • v.15 no.2
    • /
    • pp.99-106
    • /
    • 2009
  • We conducted a comparison experiment of our wide-area spraying high speed fan with a fan which was developed by Japan MARUYAMA Inc. have been much recognized for it's history and skills in a field of spraying machine. In result, MARUYAMA Inc. fan sprayed up to 120 m and, on the other hand, wide-area spraying high speed fan of our own making was able to spray up to more than 160 m. Wide-area spraying machine have been supplied to domestic demands by importing from Japan, but it is determined to be possible that home products will occupy market for it's ability, price and A/S environment in future. The main research results are below. Some plastic cups which are in the open market are used for our experiment. After distributing 90 cups in a range of 10m vertically with localizing 5 cups horizontally and 18 cups vertically, spraying machine was moved and finally we make distribution charts by estimating the sprayed amounts on each cup. Vertical distance was set up to 5m and we calculated average values by using sprayed amount and data of 4 observers. In result our fan showed much sprayed amounts than MARUYAMA Inc. all over the field except situations of vehicle departing and stopping.

  • PDF

Analysis of Performance of Cross-Flow Fan with Various Rear Guiders (리어가이더 형상변화에 따른 횡류홴 성능해석)

  • Kim, Dong-Won;Lee, Jun-Hwan;Park, Seong-Gwan;Kim, Yun-Je
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2076-2082
    • /
    • 2003
  • A cross-flow fan is widely used on many industrial fields: mining industry, automobile and home appliances, etc. The design point of the cross-flow fan is generally based on the region within low static pressure and high flow rate. It relatively makes high dynamic pressure at low speed because a working fluid passes through an impeller blade twice. However, it has low static pressure efficiency between 30% and 40% because of relative high impact loss. Recently, in the air-conditioning systems, the operating behaviors at the off-design points are highly regarded to broaden the application area for various air-cooling loads. Especially, at the lower flow rate, there exists a rapid pressure head reduction, a noise increase and an irregular flow field against a rearguider as a scroll of centrifugal fan. Numerical analyses are carried out for investigating the flow characteristics in a cross-flow fan including the impeller, the rearguider and the stabilizer. Especially, various types of rearguiders are estimated by numerical and experimental methods to insure the stable operation in the region of lower flow rate. Numerical domains are discretized by hexahedral cells. Three-dimensional, unsteady governing equations are solved using FVM, PISO algorithm, sliding grid system and standard ${\kappa}-{\varepsilon}$ turbulence model. ASHRAE standard fan tester is also used to estimate the performance of the modeled crossflow fan.

  • PDF

The Operation and Vibration Characteristics of Tail-fan Performance Test System (테일홴 성능시험장치의 운용과 진동특성)

  • Song, Keun-Woong;Kim, Jun-Ho;Kang, Hee-Jung;Rhee, Wook;Sim, Joung-Wook
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.4 s.97
    • /
    • pp.421-428
    • /
    • 2005
  • This paper described operation and vibration characteristics of a 'tail-fan' anti-torque performance test system. KARI (Korea Aerospace Research Institute) developed a 'tail-fan' anti-torque system of a helicopter and a performance test-rig to test the performance of the tail-fan. The performance test-rig consists of driving, supporting and rotating parts. In the process of the performance test, firstly, operation test of the test-rig were carried out to verify design specifications. Secondly, natural frequencies of fan blade and test-rig were measured respectively. Lastly, to find the operation rotating speed for the performance test, vibration test were carried out using accelerometers on tail gear box. The performance test conditions of the tail-fan to avoid a resonance were found from the fan-plot and vibration test results. The tail-fan performance tests were well done safely.

A Study on influence factors of User's Continuous Use Intension in Firm Promotion Social Network Service: by Mediating the Moderator of the Operation Objective Types in Facebook Fan Page (기업 SNS 이용자(고객)의 지속적 사용의도에 관한 연구:Facebook 팬페이지 운영 목적을 조절변수로)

  • Shim, Eunsun;Lee, JungHoon;Jeong, BeobGeun
    • Journal of Information Technology Services
    • /
    • v.12 no.4
    • /
    • pp.41-57
    • /
    • 2013
  • As the usage of SNS has grown dramatically over the last years, it has been used in various sectors not just a tool for communication. In particular, corporate companies actively use Facebook as a tool for corporate marketing. Corporate companies communicate with their customers by providing service or events information. In this study, empirical analysis was carried out on corporate companies that are using Facebook as a marketing tool, thus finding out the influencing factors in continued usage of Facebook Fan Page users. In addition, analysis of the factors will be investigated according to continued usage of the users, where the user's intention will differ depending on how corporate companies operate and deal with the Facebook Fan Page. Factors affecting the user's satisfaction, perceived usefulness, and perceived playfulness were deducted through the analysis of the existing literature study on corporate company's continued intention on the usage of Facebook Fan Page. Accordingly, factor affecting this such as relationship, speed, content diversity, which are the media characteristics of the Facebook were deducted and finally hypothesized. In addition, the type of corporate company's Facebook Fan Page was divided into event type, communication type, information service type. And hence investigated the factors that differed from the continued usage depending on the type. Results analysis shows that perceived usefulness affected only relationship, speed, content diversity. Furthermore, analysis shows that corporate company's Fan Page of communication and event types are the factors that affect the usage intention which meant it only affected the perceived enjoyment. On the basis of this study, we are able to present an implication of value where corporate company use it as a marketing tool, through factors from continued usage of coroporate company's Facebook Fan Page users.