• 제목/요약/키워드: Fan speed

검색결과 316건 처리시간 0.022초

발전소 통풍계통의 가변속 적용 후 진동특성에 관한 연구 (Study on Vibration Characteristics after Applying Variable Speed Control to Constant Speed Fans used in a Power Plant)

  • 조철환;송오섭;양경현;김계연;조성태;문현동
    • 동력기계공학회지
    • /
    • 제13권6호
    • /
    • pp.88-94
    • /
    • 2009
  • In this paper, vibration characteristics after applying variable speed control to fans with a rated speed used in a power plant are studied by performing experiments and analyzing finite element models. Then the campbell diagram is presented to verify the reason of the abnormal vibration measured from fan structure during variable operation of Forced Draft Fan & Induced Draft Fan. According to results, it is found that amplitude of acceleration increases abruptly when a 2X harmonic component meets the natural frequency of fan rotor. Therefore it is very important thing that investigate exactly dynamic characteristics for the rotor at variable speed zone before applying variable speed control to a rotor with a rated speed.

  • PDF

횡류팬 유로최적화를 위한 수치실험 (Numerical Experiments for the Optimization of the Flow Path through a Cross-Flow Fan)

  • 전용두;이종수
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.147-151
    • /
    • 2002
  • Cross flow fan system is widely used for various applications, especially for the air-moving device of heaters, air-conditioners, and air-curtains. Although there are efforts for the optimization of cross-flow fan flow path with different methods of approach, it is still being investigated by many researchers through experimentally and/or theoretically, because the flow pattern of the cross flow fan is not stereotyped. This paper presents some results from numerical experiments for the optimization of the flow path through a cross-flow fan to be applied to indoor wall-mounted room heater. Two dimensional analysis has been applied to a specific fan system including inlet and diffuser outlet. Flow characteristics art presented and discussed for two different flow path at three different operating conditions represented by rotational speed(800, 1,000, 1,200 rpm) of the In. According to the simulated results for the specific fan system under consideration, it could be found that the flow pattern resembles each other at different rotational speed (to say from 800 rpm to 1,200 rpm) for a fixed flow path, while the secondary flows mostly absorbs the speed effects. By changing the flow path significant increase in volume flow rate is estimated upto 2.65 at the same rotational speed. According to the present experience, fan flow path design can be performed more efficiently by incorporating this type of numerical experiments combined with the model tests.

  • PDF

모터의 특성을 고려한 CFD 해석에 의한 축류홴 성능해석 (ANALYSIS ON CHARACTERISTICS OF AN AXIAL FLOW FAN THROUGH CFD ANALYSIS INCORPORATED WITH MOTOR CHARACTERISTICS)

  • 김주한;허남건;김욱
    • 한국전산유체공학회지
    • /
    • 제15권4호
    • /
    • pp.109-114
    • /
    • 2010
  • In a fan design, CFD analysis, which is very useful for mechanical design relating to the heat and fluid dynamics, is one of the most popular tools. However, since the CFD analysis is conventionally carried out with the constant fan speed condition, the speed change, induced by the air flow rate and motor characteristics, is hardly modeled. And, consequently, the remarkable difference exist between analysis and experimental results. In this paper, we has proposed a method of setting the varying fan speed as a boundary condition considering air flow rate and motor torque-speed characteristics. The effectiveness of the proposed method is verified by comparison with experimental results.

Behavior of Rotating Stall Cell in a High Specific-Speed Diagonal Flow Fan

  • Shiomi, Norimasa;Cai, W.X.;Muraoka, A.;Kaneko, K.;Setoguchi, T.
    • Journal of Mechanical Science and Technology
    • /
    • 제15권12호
    • /
    • pp.1860-1868
    • /
    • 2001
  • An experimental investigation was carried out to clarify unsteady flow fields with rotating stall cell, especially behavior of stall cell, in a high specific-speed diagonal flow fan. As its specific-speed is vary high for a diagonal flow fan, its pressure-flow rate curve tends to indicate unstable characteristics caused by rotating stall similar to axial flow fan. Although for an axial flow fan many researchers have investigated such the flow field, for a diagonal flow fan tittle study has been done. In this study, velocity fields at rotor Inlet in a high specific-speed diagonal flow fan were measured by use of a single slant hot-wire probe. These data were processed by using the "Double Phase-Locked Averaging"(DPLA) technique, i. e. phases of both the rotor blade and the stall cell were taken into account. The behaviors of stall cell at rotor inlet were visualized for the meridional, tangential and radial velocity.

  • PDF

ATmega128 마이크로 컨트롤러를 사용한 스마트 선풍기 속도제어 (Speed Control of Smart Electric Fan using ATmega128 Microcontroller)

  • 원재혁;김정운;이성준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 에너지변화시스템부문
    • /
    • pp.281-283
    • /
    • 2009
  • This paper presents the smart fan which is operated by a small conventional motor and an ultrasonic sensor. The smart fan generates cool wind with regulated speed of wing by the distance between the user and the fan. In this research, an 8-bit microcontroller (ATmega128) and an ultrasonic sensor (NT-TS601) are utilized for the system control and sensing information. In order to obtain the speed information from the encoderless DC motor, a stroboscope is used, which provides the voltage variation by the motor speed. The proposed smart fan makes the user feel cool, convenient and safe at a low cost.

  • PDF

레이저 3차원 진동측정기와 마이크로폰을 이용한 진공청소기용 팬모터의 실험적인 공력소음 분석 (The Experimental Analysis of Aerodynamic Sound for Fan Motor in a Vacuum Cleaner Using Laser 3-D Scanning Vibrometer and Microphone)

  • 곽이구;안재신;김재열
    • 한국정밀공학회지
    • /
    • 제22권3호
    • /
    • pp.46-51
    • /
    • 2005
  • The vacuum cleaner motor runs at very high speed for suction power. Specially, motor power is provided by the impeller being rotated at very high speed. The centrifugal fan consists of the impeller, the diffuser, and the circular casing. Due to the high rotating speed of the impeller and small gap distance between the impeller and the diffuser, the level of noise in the centrifugal fan is at BPF(Blade Passage Frequency) and its harmonic frequencies. In order to calculate the sound pressure of centrifugal fan, unsteady flow data are needed. The cause of noise is obtained by dividing the fluid noise by exhaust flow of fan and vibration noise by rotational vibration of vacuum cleaner fan motor. Until now, an accelerometer has been used to measure vibration. However, it can not measure vibration in some parts of brush and commutator because of motor construction and 3-D vibrating mode. This study was conducted to perform accurate analysis of vibration and aerodynamic sound for fan motor in a vacuum cleaner using a laser vibration analyzer. A silent fan motor can be designed using the data measured in this study.

발전소 통풍계통의 가변속 운전을 위한 최적 설계조건에 관한 연구 (Study on Optimum Design Condition for Variable Speed Control of Rated Speed Fans used in a Power Plant)

  • 조철환;양경현;정남근;김봉진
    • 동력기계공학회지
    • /
    • 제14권5호
    • /
    • pp.30-35
    • /
    • 2010
  • Recently, the large capacity draft fans in power plants had been changed to variable speed type to educe the power consumption. But the fan experienced the unexpected vibration at specific speed regions. In this study, the high vibration frequency of the fan was confirmed and the natural frequency of the rotor were measured and analyzed by FEM programs. It was analyzed that the vibration was caused by the resonance at the frequency, 30.7Hz. So, the rotor vibration characteristic was changed by adjusting the distance between the shaft bearings. It was conformed the high vibration was disappeared over the all operation speeds.

진공청소기용 팬 모터의 비정상 유동 해석 및 공력소음 해석 (The Analysis of the Unsteady Flow Field and Aerodynamic Sound of Fan Motor in a Vacuum Cleaner)

  • 김재열;심재기;송경석;오성민;양동조;김우진
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 춘계학술대회 논문집
    • /
    • pp.281-286
    • /
    • 2004
  • The vacuum cleaner motor runs on very high speed for the suction power. Specially, the motive power is provided by the impeller being rotate on very high speed. And centrifugal fan consists of the impeller, the diffuser, and the circular casing. Due to the high rotating speed or the impeller and small gap distance between the impeller and diffuser, the centrifugal fan makes very high noise level at BPF and harmonic frequencies. In order to calculate the sound pressure of centrifugal fan, the unsteady flow data is needed. And Noise cause is dividing to fluid noise by exhaust flow of fan and vibration noise by rotational vibration of vacuum cleaner fan motor. Until now, measuring method has been used to measure vibration by the accelerometer; this method has been not measured for the vibration in some parts of brush and commutator because of motor construction and 3-D vibrating mode. This paper was purposed on the accurate analysis, using laser vibration analyzer,. By using this measured data of noise cause against the difficult part in old times, we would like to use for the design of silent fan motor.

  • PDF

다중 덕트 팬 전진 비행 특성에 대한 수치적 연구 (Numerical Investigation of Forward Flight Characteristics of Multi-Ducted Fan)

  • 노나현;오세종;박동훈
    • 한국항공우주학회지
    • /
    • 제46권2호
    • /
    • pp.95-105
    • /
    • 2018
  • 차세대 회전익기 개발에서 고속화는 중요한 과제이며, 선행 연구들을 통해 덕트 팬을 가지는 비행체는 고속화 실현 가능성이 높은 형상으로 평가된다. 본 연구에서는 다중 덕트 팬 비행체의 전진 비행시의 유동 특성 및 공력 성능 분석을 위한 전산해석을 수행하였다. 전방 팬의 공력 성능은 자유류 유동과 팬 유입류에 의해 결정되는 반면, 후방 팬의 성능은 전방 팬에서 발생한 유동에 지배적인 영향을 받음을 확인하였다. 전진 속도가 증가하며 전방 팬 입구에서의 유동 박리는 후방 팬보다 먼저 발생하며, 덕트 입구 박리는 팬 추력의 증가를 유도한다. 두 덕트 팬 간의 상호 작용으로 인해 후방 팬에는 상대적으로 정렬된 유동이 유입되므로 박리 이전까지 추력이 꾸준히 감소하고, 전/후방 팬의 추력의 급격한 변화는 동시에 발생한다. 전진 속도에 따라 전체 비행체의 수직력은 감소하였다. 이는 팬 후류에 의한 동체 아랫면 압력 저하가 주요 원인으로 분석되었다.

변속실외기펜을 사용한 텐텀형냉방기의 과열도제어에 관한 연구 (A Study on the Superheat Control of a Tandem-type Airconditioner by Using a Variable Speed Outdoor Fan)

  • 김재현;한도영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.474-479
    • /
    • 2005
  • For the safe operation of an air conditioner, the liquid car η 'over to compressors should be minimized and compressors should be operated in the specified region of suction and discharge pressures recommended by compressor manufactures. In this study, a capillary assisted tandem-type airconditioner was considered. A variable speed outdoor fan was used to control operating points of the system. Test results showed the possibilities to move system operating points to the safe region by controlling the speed of an outdoor fan.

  • PDF