• Title/Summary/Keyword: Fan identification

Search Result 68, Processing Time 0.031 seconds

Results and implications of the damage index method applied to a multi-span continuous segmental prestressed concrete bridge

  • Wang, Ming L.;Xu, Fan L.;Lloyd, George M.
    • Structural Engineering and Mechanics
    • /
    • v.10 no.1
    • /
    • pp.37-51
    • /
    • 2000
  • Identification of damage location based on modal measurement is an important problem in structural health monitoring. The damage index method that attempts to evaluate the changes in modal strain energy distribution has been found to be effective under certain circumstances. In this paper two damage index methods using bending strain energy and shear strain energy have been evaluated for numerous cases at different locations and degrees of damage. The objective is to evaluate the feasibility of the damage index method to localize the damage on large span concrete bridge. Finite element models were used as the test structures. Finally this method was used to predict the damage location in an actual structure, using the results of a modal survey from a large concrete bridge.

Source localization of impact noise on an indoor unit of air-conditioner (에어컨 실내기에서 발생하는 충격 소음원의 위치 추정)

  • 최영철;김양한;이종구;김구영
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.324-329
    • /
    • 2003
  • An air-conditioner has various noise sources such as cooling fan noise, pumping noise, flow noise and impact noise. Among these, impact noise is the most unpleasant source. This is because the noise is produced in indoor unit of air-conditioner. To control the noise source effectively, first we must identify the noise sources. When we identify impact noise source, the measurement have to be carried out simultaneously. So we use beamforming method that requires less measurement points than intensity method and acoustic holography. The objective of this paper is to estimate the location of impact source. This objective can be achieved by using minimum variance cepstrum that is able to detect impulse embedded in noise. In this study, modified beamforming method based on cepstrum domain is proposed. Then this method applied to air-conditioner noise sources which produce impact noise.

  • PDF

Evaluation and countermeasure for Environmental Noise during Plant Commissioning Process in Thermal Power Plant (화력발전소 시운전시 인근에 미치는 소음영향 및 대책)

  • Kim, Yeon-Whan;Koo, Jae-Raeyang;Kim, Hee-Soo;Bae, Yong-Chae;Lee, Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.897-902
    • /
    • 2001
  • This paper describes the evaluation of noise influence for residental and boundary areas in 75MW thermal power plant. It includes the measurements of noise level around the boundary area of the plant, identification of noise propagating path, and discussion on the measures. Noise assessments are carried out based on the ISO 3744, ISO 9613-1 and ISO 9613-2 to predict the noise distribution of specific locations from the noise sources such as power transformers, flash vent-pipe, I.D.fan, and stack. It is identified the vent-pipe of flash tank in thermal power plant as the root cause of the environmental noise during the plant commissioning process.

  • PDF

Experimental studies of suppressing effectiveness on sloshing with two perforated floating plates

  • Yu, Yue-Min;Ma, Ning;Fan, She-Ming;Gu, Xie-Chong
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.11 no.1
    • /
    • pp.285-293
    • /
    • 2019
  • In the present paper, model tests of suppressing sloshing fitted with two perforated floating plates are carried out. The study involves identification of system performance such as the suppression and the solidity ratio. Three different solidity ratios of perforated plates have been tried out as potential positive slosh damping devices. A series of painstaking experiments have been conducted in a rigid rectangular tank on six degrees of freedom motion platform under roll harmonic excitation. Comparison of the clean tank shows that the three types of perforated plates are all effective on damping the run-up and impact pressure along the bulkhead. The parametric study indicates that the perforated plate with the median solidity ratio is the most optimal one in suppressing sloshing among three configurations.

Identification of Printer Noise Source and Its Sound Quality Evaluation System Development (프린터 부품 소음원에 따른 감성소음 평가시스템의 개발)

  • Park, Sang-Won;Yang, Hong-Jun;Na, Eun-Woo;Lee, Sang-Kwon;Park, Yeong-Jae;Kim, Jong-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.11
    • /
    • pp.1018-1024
    • /
    • 2010
  • The printer noise consists of the noise of the various components and parts such as motor, fan and solenoid. And the human's printing sound recognition shows various aspects when the printer starts to print papers because the components operate at the same time. Especially, printers are usually installed in the quiet office room. Therefore the printing noise is related to its competitiveness in the market. The importance of the printer sound qualities is increasing and it is necessary to develop the sound quality evaluation system, so it is a key point to identify the noise source of the printer and develop the sound quality index to each component. By using this evaluation system, it is possible to evaluate the sound quality of a prototype printer compared to the already existing one. In this paper, the printer sound quality evaluation system was developed by the following steps. Firstly, the signal processing method was applied to the recorded printing sound to identity and split the noise of components. Secondly, the MLR(multiple linear regression) method and the psychoacoustics were used to develop the sound quality index. Finally, the improvement of the printer sound quality is possible by using the result of the MLR and the path analysis. The output of this research will be applied to the development of a new printer.

Qualitative Research on Consumption of Professional Baseball Club's Licensed Fashion Product (프로야구구단의 라이선싱 패션제품 소비에 대한 질적 연구)

  • Son, Seong-Yi;Lee, Yoon-Jung
    • Journal of the Korean Society of Costume
    • /
    • v.66 no.4
    • /
    • pp.18-31
    • /
    • 2016
  • This study examined the consumption of licensed sports fashion products by sports fans in order to provide useful information to apparel companies that are interested in sports sponsorship marketing. Grounded theory approach was adopted to explore consumers' attitude toward the sponsoring companies, and motives of buying licensed fashion products. In-depth interviews were conducted with female fans of professional baseball clubs. The main phenomena of interest was consumer purchase of licensed fashion product, with the emphasis on cultural consumption as a causal condition. Providing support for victory, vicarious consumption, social identification, and needs to differentiate were identified as strategies related to licensed product purchase. Economic situations and limitations to purchase are identified as the mediating conditions. The study identified the effects of the consumption on the fan as well as the sponsoring companies as consequences of the phenomena. Sports marketing strategies were suggested for apparel companies based on the analysis of the consumption rituals for licensed fashion goods.

Indoor Temperature Control of an Air-Conditioning System Using Model Predictive Control (모델예측제어를 이용한 에어컨 시스템의 실내온도 제어)

  • Jo, Hang-Cheol;Byeon, Gyeong-Seok;Song, Jae-Bok;Jang, Hyo-Hwan;Choe, Yeong-Don
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.4
    • /
    • pp.467-474
    • /
    • 2001
  • The mathematical model of a air-conditioning system is generally very complex and difficult to apply to controller design. In this paper, simple models applicable to the controller design are obtained by modeling the air-conditioning system by single-input single-output between compressor speed and indoor temperature, and by multi-input single-output between compressor speed, indoor fan speed and indoor temperature. Using these empirical models, model predictive control(MPC) technique was implemented for indoor temperature control of the air-conditioning system. It has been shown from various experiments that the indoor temperature control based on the MPC scheme yields reasonably good tracking performance with smooth changes in plant inputs. this multi-input multi-output MPC approach can be extended to multi air- conditioning systems where the conventional PID control scheme is very difficult to apply.

Icefex: Protocol Format Extraction from IL-based Concolic Execution

  • Pan, Fan;Wu, Li-Fa;Hong, Zheng;Li, Hua-Bo;Lai, Hai-Guang;Zheng, Chen-Hui
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.3
    • /
    • pp.576-599
    • /
    • 2013
  • Protocol reverse engineering is useful for many security applications, including intelligent fuzzing, intrusion detection and fingerprint generation. Since manual reverse engineering is a time-consuming and tedious process, a number of automatic techniques have been proposed. However, the accuracy of these techniques is limited due to the complexity of binary instructions, and the derived formats have missed constraints that are critical for security applications. In this paper, we propose a new approach for protocol format extraction. Our approach reasons about only the evaluation behavior of a program on the input message from concolic execution, and enables field identification and constraint inference with high accuracy. Moreover, it performs binary analysis with low complexity by reducing modern instruction sets to BIL, a small, well-specified and architecture-independent language. We have implemented our approach into a system called Icefex and evaluated it over real-world implementations of DNS, eDonkey, FTP, HTTP and McAfee ePO protocols. Experimental results show that our approach is more accurate and effective at extracting protocol formats than other approaches.

Phase identification of $C_3N_4$ in CN films prepared by rf plasma chemical vapor deposition and dc magnetron sputtering

  • Fu, Dejun;Wu, Dawei;Zhang, Zhihong;Meng, Xianquan;He, Mengbing;Guo, Huaixi;Peng, Yougui;Fan, Xiangjun
    • Journal of the Korean Vacuum Society
    • /
    • v.7 no.s1
    • /
    • pp.140-148
    • /
    • 1998
  • We prepared $C_3N_4$ films by rf plasma enhanced chemical vapor deposition(PCVD) and alternating $C_3N_4$/TiN composite films by dc magnetron sputtering. X-ray diffraction (XRD) and transmission electron diffraction (TED) revealed that the structure of the films is amorphous or polycrystalline, depending on deposition conditions and heat treatment. X-ray photoelectron spectroscopy (XPS) and Fourier transform infrared (FTIR) spectroscopy confirmed the presence of $sp_3\; and sp _2$ hybridized C atoms bonded with N atoms in the tetrahedral and hexagonal configurations, respectively. Graphite-free $C_3N_4$ films were obtained by PCVD under optimal conditions. To prepare well crystallized $C_3N_4$ films by magnetron sputtering, we introduced negatively biased gratings in the sputtering system. CN films deposited at grating voltages (Vg) lower than 400V are amorphous. Crystallites of cubic and $\beta$-$C_3N_4$ were formed at increased voltages.

  • PDF

Noise, vibration Characteristic Identification and Noise Control of Indoor Air-Conditioner's Cabinet using Operational Deflection Shape (운행 중 변형형상을 이용한 에어컨 실내기 캐비닛의 소음/진동 특성 파악 및 제어)

  • Lee, Seong-Jin;Oh, Jae-Eung;Lee, Jung-Youn;Kang, Tae-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.830-833
    • /
    • 2004
  • An indoor package air-conditioner (PAC) has complex noise sources such as motor noise and fluid noise caused by the fan motor, heat transfer and shroud. Sound intensity techniques and ODS(Operational deflection shape) techniques are applied to identify the noise characteristics of an indoor air-conditioner's cabinet. The sound intensity is used to visualize the noise source locations. and the ODS to visualize the vibration pattern and to obtain the dynamic characteristics of the noise source. Acoustic intensity and operational deflection distribution are obtained in space domains as well as frequency domains. Using the visual information of source locations and its dynamic characteristics, the damping patch is applied to reduce structure borne noise in the cabinet. As a result, the noise emitted by the cabinet is reduced by 5dB.

  • PDF