• Title/Summary/Keyword: Fan Pressurization/Depressurization Method

Search Result 4, Processing Time 0.017 seconds

Study on the Establishment of Large Building Airtightness Measurement Standards (대규모 건물의 기밀성능 측정기준 수립에 관한 연구)

  • Lee, Dong-Seok;Ji, Kyung-Hwan;Jo, Jae-Hun
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.1
    • /
    • pp.117-124
    • /
    • 2014
  • Airtightness standards using fan pressurization method are normally used for measuring small buildings, detached houses, and apartment units. And, it is easy to conduct airtightness measurement through this fan pressurization method. However, it can be difficult to achieve accurate measurement results for the large buildings as the height and volume of the buildings have been increased. In this paper, we studied the principle of airtightness method by fan pressurization. And, we reviewed the measurement process described in ISO 9972, EN 13829, ASTM E779, ATTMA TS 1, CAN/CGSB 149.15, and JIS A 2201. Then, we categorized the methods' items according by air flow rate (Q) and pressure difference(${\Delta}P$). As a result, we made a comparison analysis on the measurement methods appeared in each standards. And, we achieved 5 test conditions about air flow rate and pressure difference to state requirements for large buildings airtightness measurement.

Developing the Construction Guideline for ZEB Based on Air-tightness of Public Buildings in Korea (국내 비주거용 건물의 기밀성능 측정 결과를 통한 기밀 시공 가이드라인 개발)

  • Bae, Minjung;Choi, Gyeongseok
    • Land and Housing Review
    • /
    • v.11 no.3
    • /
    • pp.69-74
    • /
    • 2020
  • Since the design Standard for Energy Conservation in Building was implemented in 2008 for the first time, building elements such as window and door should satisfy the minimum criteria to apply for a building. Though its regulation does not cover the whole building yet, recent demand to reduce energy consumption in building sector grows rapidly year by year and also draws a lot of interest to ensure the whole building level. For example, a Zero energy building, one of low-energy buildings, requires a customized solution to resolve the air leakage issue to meet the standards in achieving the high level of air tightness. In this study, six non-residential buildings were tested by fan pressurization method to observe the air tightness of whole building to suggest the construction guideline for air tightness of low-energy building. Five out of six tested buildings showed 0.27 to 1.16 h-1 of number of air changes except one community center. These buildings were carefully constructed not only for building planning but also for parts where there was a concern of air leakage, thereby securing high levels of air-tightness. The construction skills were developed as a checklist to manage and supervise the construction site. It is our suggestion to use this checklist at construction sites for ZEB with the high level of air-tightness.

A Study on the Calculation Method of Infiltration for Detached Houses (기존 단독주택의 침기량 산정법에 관한 연구)

  • Kim, Giltae;Yoo, Jung-Hyun;Hwang, Ha-Jin;Kim, Kyoung-Sik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.9
    • /
    • pp.493-498
    • /
    • 2013
  • The purpose of this study is to find the infiltration of detached houses, for energy consumption analyses. The pressurization and depressurization method is used to determine infiltration. Blower door tests are expressed in terms of ACH 50, which stands for the hourly air change rate at 50 Pa of fan pressure. The ACH 50 of existing Detached Houses ranges from 5 to 50. Air infiltration is related to construction year and accuracy, maintenance conditions, and so on. When estimating the infiltration of random detached houses, the year used can be the base value of the infiltration rate from 0.25 to 2.0 times/h. The maintenance conditions, construction accuracy and repair affect the air infiltration 0 to 0.5 times/h, 0 to 0.3 times/h, 0 to 1 times/h, respectively.

A Study on the Airtightness Performance of New Han-ok Bedrooms (신한옥 침실 공간의 기밀성능 평가 연구)

  • Lee, Ju-Yeob;Jang, Hyeon-Chung;Lee, Tai-Gang;Song, Min-Jeong;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.79-89
    • /
    • 2013
  • The purpose of this study is to evaluate the airtightness performance of New Han-ok and to supply fundamental data for standards establishment. Air leakage testings were accomplished by means of blower door test in 26 bedrooms of 16 Han-oks located in Jeonnam happy villages. Followings are results. 1) Air change per hour at 50 Pa(ACH50) is located on 8.42~78.38. 2) No correlation between ACH50 and volumes, floor area, above grade surface area. 3) The more wood structural elements are exposed, attached spaces, wooden sliding and casement windows, the less airtightness performance. 4) An Airtightness with ACH50/20(NL, Normalized leakage) is located on 0.42~3.92 and building leakage class following F(4%), G(11%, sufficiently leaky, No need mechanical ventilation), H(4%, Need of cost-effective tightening), I(31%), J(50%) by a single-story house the normalized leakage of ASHRAE.