대규모 건물의 기밀성능 측정기준 수립에 관한 연구 (Study on the Establishment of Large Building Airtightness Measurement Standards)

  • 이동석;지경환;조재훈
    • 한국태양에너지학회 논문집
    • /
    • 제34권1호
    • /
    • pp.117-124
    • /
    • 2014
  • Airtightness standards using fan pressurization method are normally used for measuring small buildings, detached houses, and apartment units. And, it is easy to conduct airtightness measurement through this fan pressurization method. However, it can be difficult to achieve accurate measurement results for the large buildings as the height and volume of the buildings have been increased. In this paper, we studied the principle of airtightness method by fan pressurization. And, we reviewed the measurement process described in ISO 9972, EN 13829, ASTM E779, ATTMA TS 1, CAN/CGSB 149.15, and JIS A 2201. Then, we categorized the methods' items according by air flow rate (Q) and pressure difference(${\Delta}P$). As a result, we made a comparison analysis on the measurement methods appeared in each standards. And, we achieved 5 test conditions about air flow rate and pressure difference to state requirements for large buildings airtightness measurement.

다가구 및 다세대 원룸주택의 기밀성능 실측연구 (The Measurement of Airtightness Performance of Multi-Family Housing)

  • 백남춘;한승현;이왕제;윤종호;신우철
    • KIEAE Journal
    • /
    • 제14권5호
    • /
    • pp.117-121
    • /
    • 2014
  • Even though a study of airtightness performance of apartment and detached house have been done constantly, there are few of studies of multi-family housing which increasing every year. Therefore, this study analyzed airtightness performance of 20 households of one room in Daejeon to investigate airtightness performance standard. All experiments were performed under the same conditions except sealing windows to investigate airtightness performance without sealing windows (natural condition) and airtightness performance with sealing windows of studio apartment. As results, (1) average ACH50 without sealing windows was 19.2/h for pressurization, and 12.8/h for depressurization and (2) average ACH50 with sealing windows was 16.0/h for pressurization, and 10.7/h for depressurization and ACH50 in both condition, ACH50 under pressurization was about 50% higher than that under depressurization. Throughout this experiment, we can figure out that about 16% of air infiltration rate is occurred in windows, and the other 84% is occurred in rest of places such as Junction structure, socket and ventilating opening.

국내 비주거용 건물의 기밀성능 측정 결과를 통한 기밀 시공 가이드라인 개발 (Developing the Construction Guideline for ZEB Based on Air-tightness of Public Buildings in Korea)

  • 배민정;최경석
    • 토지주택연구
    • /
    • 제11권3호
    • /
    • pp.69-74
    • /
    • 2020
  • Since the design Standard for Energy Conservation in Building was implemented in 2008 for the first time, building elements such as window and door should satisfy the minimum criteria to apply for a building. Though its regulation does not cover the whole building yet, recent demand to reduce energy consumption in building sector grows rapidly year by year and also draws a lot of interest to ensure the whole building level. For example, a Zero energy building, one of low-energy buildings, requires a customized solution to resolve the air leakage issue to meet the standards in achieving the high level of air tightness. In this study, six non-residential buildings were tested by fan pressurization method to observe the air tightness of whole building to suggest the construction guideline for air tightness of low-energy building. Five out of six tested buildings showed 0.27 to 1.16 h-1 of number of air changes except one community center. These buildings were carefully constructed not only for building planning but also for parts where there was a concern of air leakage, thereby securing high levels of air-tightness. The construction skills were developed as a checklist to manage and supervise the construction site. It is our suggestion to use this checklist at construction sites for ZEB with the high level of air-tightness.

고층건축물 수직 샤프트 연돌효과 해소방법에 대한 연구 (The Study on the Solution of Stack effect in the Vertical shaft of High-rise Buildings)

  • 김진수;장희철
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2007년도 정기총회 및 학술발표대회
    • /
    • pp.242-245
    • /
    • 2007
  • 초고층건물의 주된 피난경로인 계단실에 발생하는 연돌효과는 계단실 차압분포에 큰 영향을 주고 피난에 장애가 될 수도 있으므로 적정 범위 내에서 억제되어야한다. 고층건물의 연돌효과를 해소하는 방법을 찾기 위해 몇 가지 경우에 대해 시뮬레이션을 하고 계단실 상하부의 fan으로 가압과 감압을 적절히 병용한 결과 연돌효과에 의한 차압불균형을 해소할 수 있었다.

  • PDF

신한옥 침실 공간의 기밀성능 평가 연구 (A Study on the Airtightness Performance of New Han-ok Bedrooms)

  • 이주엽;장현충;이태강;송민정;김선우
    • KIEAE Journal
    • /
    • 제13권3호
    • /
    • pp.79-89
    • /
    • 2013
  • The purpose of this study is to evaluate the airtightness performance of New Han-ok and to supply fundamental data for standards establishment. Air leakage testings were accomplished by means of blower door test in 26 bedrooms of 16 Han-oks located in Jeonnam happy villages. Followings are results. 1) Air change per hour at 50 Pa(ACH50) is located on 8.42~78.38. 2) No correlation between ACH50 and volumes, floor area, above grade surface area. 3) The more wood structural elements are exposed, attached spaces, wooden sliding and casement windows, the less airtightness performance. 4) An Airtightness with ACH50/20(NL, Normalized leakage) is located on 0.42~3.92 and building leakage class following F(4%), G(11%, sufficiently leaky, No need mechanical ventilation), H(4%, Need of cost-effective tightening), I(31%), J(50%) by a single-story house the normalized leakage of ASHRAE.

기존 단독주택의 침기량 산정법에 관한 연구 (A Study on the Calculation Method of Infiltration for Detached Houses)

  • 김길태;유정현;황하진;김경식
    • 설비공학논문집
    • /
    • 제25권9호
    • /
    • pp.493-498
    • /
    • 2013
  • The purpose of this study is to find the infiltration of detached houses, for energy consumption analyses. The pressurization and depressurization method is used to determine infiltration. Blower door tests are expressed in terms of ACH 50, which stands for the hourly air change rate at 50 Pa of fan pressure. The ACH 50 of existing Detached Houses ranges from 5 to 50. Air infiltration is related to construction year and accuracy, maintenance conditions, and so on. When estimating the infiltration of random detached houses, the year used can be the base value of the infiltration rate from 0.25 to 2.0 times/h. The maintenance conditions, construction accuracy and repair affect the air infiltration 0 to 0.5 times/h, 0 to 0.3 times/h, 0 to 1 times/h, respectively.