A Study on the Noise Emission Characteristics of Turbo Axial Flow Fan by Experimental Method (터보형송풍기의 소음 방사특성에 관한 실험적 연구)

  • 김동규;백종진
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.271-277
    • /
    • 2003
  • Recently as the environmental noise getting influential social problem, it is the fact that the demand on noise reduction increases with the advance of the standard of living. Therefore increasing the interest on the noise in common, it is eagerly demanded that the endeavour for reducing the noise of the rotating machinery, especially the machinery related a flowing including the household electric products, which is pointed out the primary noise source in environment. As proceeding study for fan noise, theory of fan noise property is arranged and this control method is shown. Blade passage noise of total noise spectrum. Thus in the aspect of noise reduction, noise source and identification of noise radiation characteristics of axial flow fan are demanded in detail. The sound source is analyzed by using sound pressure and sound intensity. In that time, synchronization of axial flow fan using optical sensor is executed, and to identify the location of exact noise source in the fan profile determination of recording time is proposed. In the rotating of tan, it is explained that the location of noise source exists in and by the directivity, the noise radiation pattern of axial flow fan is determined and the flow of sound is visualized in the figure of contour mapping.

  • PDF

Design of Automotive Engine Cooling Fan and Study on Noise Reduction through Modification of System (자동차용 냉각홴의 설계와 시스템 개선을 통한 저소음화 연구)

  • 김병주;강상규;김규영;이재영;이덕호;신동수
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.11
    • /
    • pp.1107-1114
    • /
    • 2004
  • Axial fans are widely used for automotive engine cooling device due to their ability to produce high flow rate to keep engine cool. At the same time, the noise generated by these fans causes one of the most serious problems. Especially, engine cooling fan noise in idle condition of a car is noticeable. Therefore. the high efficient and low-noise fan is seriously needed. When a new fan system is designed, system resistance and non-uniform inflow are the key factors to get the high performance and low noise fan system. In this study, aerodynamic and acoustic calculations are carried out on the automotive cooling fan and system. Effects of various design parameters are studied through the free wake analysis and experiments. Better performance and noise characteristic are obtained for the new design fan using the methodology. Furthermore through the modification of the fan system geometry parameters, the fan system produce more flow rate and become less noisy.

Source Identification and Reduction of Noise for the Outdoor Unit of Room Air Conditioner (실외기 소음원 규명 및 소음저감)

  • 서상호;이근동;이내영;진심원
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.575-581
    • /
    • 1998
  • The noise sources in the outdoor unit of RAC(Room Air Conditioner) are identified by the sound intensity method. The main noise sources are compressor noise and fluid noise which is caused by the fan, heat exchanger and shroud. First, the fluid noise is reduced through the design ol new fan and shroud with high flow rate and low noise, reduction of the system resistance by rearrangement of heat exchanger, and optimization of the complex parameter between the fan and shroud. Next, in order to reduce the compressor noise, the new shape of compressor mount and sound-proof material was applied. As a result, the overall noise was reduced by 4-5dB(A).

  • PDF

Investigation of the noise sources for the centrifugal fan and aeroacoustic noise prediction (진공청소기 원심 홴의 소음원 분석 및 공력 소음 예측)

  • Jeong, Ye-Eun;Bae, Young-Min;Moon, Young-J.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.645-645
    • /
    • 2009
  • In many practical applications of the centrifugal fan, the impeller-diffuser interaction noise is considered as a main source of fan noise. The housing for an electric motor is also expected to play an important role on noise propagation because of its complicated configuration. This study investigates the impeller-diffuser interaction noise and its sources by computing three-dimensional, incompressible flow field of the centrifugal fan in motor housing. The effect of motor case on fan noise characteristic is then investigated using the Brinkman penalization method, while the noise source associated with impeller-diffuser interaction is mathematically modeled. It is found that the present methodology combined with mathematical description of noise source provides a fairly good agreement with the experimental results, indicating that the motor housing has significant effect on noise characteristics. Finally, aeroacoustic noise prediction for various impeller-diffuser blade count ratios is conducted for noise reduction.

  • PDF

Analysis for the Reduction of Tonal Noise in the Centrifugal Fan for the Ship Considering Structural and Electromagnetic Characteristics of the Fan-Motor System (팬-모터의 구조 및 전자기적 특성을 고려한 선박용 원심 팬의 순음 저감 분석)

  • Han, Hyung-Suk;Jang, Cheon-Ik;Lee, Sang-Gu;Koo, Ja-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.359-367
    • /
    • 2008
  • The maximum sound pressure level in a ship is restricted by the international standard such as MIL-Std. 740-1 in order to protect hearing ability for the crew on a ship. Especially, the noise of a fan system is restricted by the maximum level of the sound power according to the military specification such as MIL-F-1900A. In this paper, the reduction of tonal noise for the fan-motor system on a ship is described related to the electrical as well as structural problems. For the electrical problems, the difference of the magnetic flux caused by the variation of the air-gap is described related to the bad concentricity of the motor housing and the shaft-bearing. And for the structural problem, the resonance of the fan motor system is described.

  • PDF

Study on Noise Reduction by Optimizations of In-line Duct Flow (덕트의 유로 최적화를 통한 소음저감 연구)

  • Han, Jae-Oh;Lee, Soo-Young;Mo, Jin-Yong;Lee, Jai-Kwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.803-808
    • /
    • 2006
  • This paper was a study about noise reduction through flow stabilization in duel using experimental method and numerical analysis at the same time. To determine the fan's type three kinds of fans(axial fan, centrifugal fan, and axial fan with centrifugal type) was examined to investigate the suitability for duct. As a result, under the equal number of rotation 2000 RPM, performance of an axial fan with centrifugal type was the most superior by 55dBA at 4.3CMM among other fans. After this, analyzed the results of the numerical analysis to find out the optimum design of pitch angle such as $0^{\circ},\;10^{\circ},\;15^{\circ}\;and\;20^{\circ}$. The intensity of turbulence was low when pitch angle was $15^{\circ}$ and air volume became peak by 5.08 CMM. It was observed that axis component of velocity increased gradually when pitch angle increased from $0^{\circ}\;to\;20^{\circ}$. Finally, designed the shapes of D/S(Down Stream) in duct that agreed inlet angle($\delta$) of stationary blades with pitch angle($\beta$) of axial fan with centrifugal type and derived flow to duct medial, and changed the shape of motor-mount to reduce occurance of unstable vortex in tip of impeller, and embodied noise reduction and improvement of air flow rate through flow stabilization.

  • PDF

A study on the aeroacoustic characteristics of the sirocco fan of over the range (후드겸용 전자렌지 시로코홴의 소음특성에 관한 연구)

  • Jeon, Wan-Ho;Song, Sung-Bae;Sohn, Sang-Bum;Rew, Ho Seon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.123-128
    • /
    • 2002
  • Over the range(OTR) has been applied for cooking and ventilation functions especially in northern Amarica. Because flow rate and operating rpm of the double sided sirocco fan for ventilation are much higher and than the microwave oven system, the major noise source is the sirocco fm. Recently, the quiet fan development is one of very important issues for amenity. In this study, the noise source identification using multi-microphone array system was carefully carried out and numerical simulations for understanding the aerodynamic and aeroacoustic of the fan were peformed. The sound level of tonal noise is predicted with a good accuracy but that of the broadband shows some discrepancy. In order to reduce the broadband noise, the inlet region of sirocco fan have to be modified that the secondary flow should be suppressed. Based on these results, new low noise fan and OTR is now developing.

  • PDF

An Experimental Study on the Noise Characteristics and Reduction of a Ventilating Fan System (환기팬 시스템의 소음특성과 저감에 관한 실험적 연구)

  • Kim, Deok-Han;Lee, Dong-Hoon;Kwon, Hyuk-Jung;Kim, Dong-Yun;Lee, Jong-Seok
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.500-505
    • /
    • 2005
  • This paper introduces an experimental study for the noise characteristics and reduction of a ventilating fan system. For the purpose of noise reduction of it, an absorptive duct silencer filled with a glass fiber has been conventionally utilized. However, a glass fiber has some disadvantages like hygiene and secondary pollution problems. In order to overcome these problems, in this paper, a perforated duct silencer has been applied to the ventilating fan system. For the designing of a perforated duct silencer, the transmission losses for various perforated panel systems are measured and compared with their sound absorption performances.

  • PDF

Noise Characteristics of Improved Sirocco Fan for Range Hood (렌지 후드 용 개선된 시로코 홴의 소음특성 변화)

  • Kim, Cheol-Ho;Choi, Young-Seok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.209-212
    • /
    • 2005
  • Recently, since structures have become extremely airtight with the development of high-rise apartments, mixed use residential and commercial buildings and offices, large capacity range hoods have become commonly implemented. However, the high noise level caused by this range hood system made of thin plate is the cause of increased complaints among users. In this study, the level of noise emitted from this type of range hood was measured by height at the user's location in the kitchen. It was confirmed that a great deal of noise was emitted in the downward direction of the hood. In order to minimize the noise emitted from this type of range hood, a new type of fan was manufactured. This was done by changing only the material and shape of the fan, since it was determined to be the primary source of noise emission. Then a comparison and evaluation were carried out regarding the noise characteristics between the new type of fan and the existing type of fan. As a result, it was confirmed that the noise from the new fan was reduced by more than 2 dB compared to the existing fan without noise interference at the discharge end.

  • PDF

The Noise Reduction of Industrial Blower by Optimal Positioning of Buff (버프의 최적 위치를 통한 산업용 송풍기의 소음저감)

  • Kim, Chang-Ho;Son, In-Soo;Ahn, Tae-Soo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.8 no.1
    • /
    • pp.71-76
    • /
    • 2009
  • In a running blower, there are various exciting forces which can generate noise. The noise of an running industrial fan or blower depends on the structure of a fan, the machining accuracy of each element, and assembled conditions. Many studies have been carried out to reduce the noise of it. In this study, 3-hole buffs are used in pipe of blower to study the influence the number and position of buffs on the noise reduction at inlet and outlet in pipe. Commercial engineering software ANSYS and SYSNOISE were employed to analyze the characteristics and reduction ratio of pressure. It is concluded that optimal position and number of buffs in pipe of blower to show the least reduction ratio of pressure.

  • PDF