A Study on the necessity of smoke control system in the tunnel fire using fire simulation (화재시뮬레이션을 이용한 터널 내 화재시 제연설비 필요성 검토)

  • Ha, Ye-Jin;Jeon, Joon-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.241-242
    • /
    • 2022
  • In this study, fire simualtion was performed to examine the necessity of smoke control system in the tunnel fire. The heat release rate was set to 5 MW and 20MW, and the visibility was measured at 1.8 m, which is the breathing limit, when there is no jet fan. Through this, it was confirmed that 5 MW did not affect the visibility even without the jet fan, and in the case of 20 MW, a jet fan was required to secure the visibility. The visibility was measured at the same location by installing the jet fan, and the simulation was performed by reducing the design volume flow rate of 8.5 m3/s by 80% and 50%, respectively. As a result, it was confirmed that sufficient visibility was secured when the design flow rate and 80% were reduced.

  • PDF

헬리콥터용 반토오크 시스템 1차 시제 성능시험

  • Song, Keun-Woong;Kang, Hee-Jung;Sim, Joung-Wook;Lee, Je-Dong;Kim, Seung-Bum
    • Aerospace Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.50-59
    • /
    • 2005
  • This paper described performance test of 1st prototype "Tail-Fan" system. KARI(Korea Aerospace Research Institute) developed "Tail-Fan" system as a kind of helicopter anti-torque system(ATS) and designed ATS performance test-rig for Tail-Fan system performance test. For Tail-Fan system performance tests, firstly, test-rig operation tests were carried out for verification of design specifications. And natural frequencies of fan blade and test-rig were measured respectively. To find the operation rotating speed for performance tests, vibration tests using accelerometers on tail gear box(TGB) were carried out. Through the fanplot and vibration test results, rotational speed for Tail-Fan performance test to avoid a resonance were found and performance tests were carried out in flight conditions. We analyzed test data by non-dimensionalization. Through this results, 1st prototype "Tail-Fan" system was satisfied with design requirements.

  • PDF

Analysis of the Viscous Flow Around a Front End Cooling Fan (자동차 프런트 엔드 쿨링팬 주위의 점성유동 해석)

  • Bae, Chun-Keun;Oh, Keon-Je;Cho, Won-Bong;Ju, Phil-Ho;Kim, Jong-Cheol
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1371-1376
    • /
    • 2004
  • Flow analysis of automobile front-end cooling fan are numerically investigated. The Navier-Stokes equations and the continuity equation are solved in the flow domain. The Reynolds stresses are modelled using the $k-{\varepsilon}$ turbulence model. Flow and pressure characteristics around the fan are investigated. The pressure sharply increases through the fan. Pressure variations on the pressure and suction sides of the fan are well represented in the calculations. The flow streamlines in the blade passage are nearly parallel to the blade.

  • PDF

Development of Electrical and Oil Heater for Energy Saving (에너지 절감형 전기 유류 겸용 온풍기 개발)

  • Chung, Sung-Won;Kim, Dong-Keon;Gong, Sang-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.5
    • /
    • pp.38-43
    • /
    • 2011
  • This study was carried out to evaluate the structural stability of hybrid type fan heater. The evaluation of structural safety of hybrid fan heater was conducted by using Ansys Workbench and CFX-11 under the design condition. The hybrid fan heater was operated by heat transfer for heat source supplied from electric heater and combustion gas. According to result of structural analysis, the maximum equivalent stress of hybrid fan heater was 150MPa when the temperature of heat transfer fluids was $150^{\circ}C$. It was found that the hybrid fan was structurally safe because the value of maximum equivalent stress was smaller than that of yield stress of the material.

Experimental Study on the Mean Flow Characteristics of Forward-Curved Centrifugal Fans

  • Kwon, Eui-Yong;Cho, Nam-Hyo
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.12
    • /
    • pp.1728-1738
    • /
    • 2001
  • Measurements have been made in an automotive HVAC b1ower for two different centrifugal fans. This work is directed at improving the performance of a conventional forward-curved centrifugal fan for a given small blower casing. Mean velocities and pressure have been measured using a miniature five-hole probe and a pressure scanning unit connected to an online data acquisition system. First, we obtained the fan performance versus flow rates showing a significant attenuation of unstable nature achieved with the new fan rotor in the surging operation range. Second, aerodynamic characterizations were carried out by investigating the velocity and pressure fields in the casing flow passage for different fan operating conditions. The measurements stowed that performance coefficients are strongly influenced by flow characteristics at the throat region. The main flow features ware common in both fans, but improved performance is achieved with tole new fan rotor, particularly in lower flow rate legions. Based on the measured results, design improvements were carried out in an acceptable operation range, which gave considerable insight into what features of flow behavior ware most important.

  • PDF

Experimental Study on the Aerodynamic Performance of Double Inlet Sirocco Fan for a Package Air Conditioner (PAC용 양흡입 시로코홴의 공력성능에 관한 실험적 연구)

  • Kim, Jang-Kweon;Oh, Seok-Hyung
    • Journal of Power System Engineering
    • /
    • v.17 no.1
    • /
    • pp.58-63
    • /
    • 2013
  • The aerodynamic performance of double inlet sirocco fan is strongly dependent upon the design factors of impeller and scroll. In this paper, the change of scroll size was adopted to investigate the aerodynamic performances of double inlet sirocco fan and indoor PAC. Especially, a scroll expansion angle and a cut-off clearance ratio were considered to change the scroll size. In addition, the installation depth between double inlet sirocco fan and indoor PAC was considered. As a result, the total pressure efficiency of double inlet sirocco fan shows about 62%~73% according to the change of scroll expansion angles. Moreover, the flowrate performance of indoor PAC is the best at the condition of a scroll expansion angle of 8°, an installation depth of 15 mm and a cut-off clearance ratio of 8%.

Performance Improvement of Fan and Duct System for Kimchi Refrigerator (김치 냉장고용 홴 및 덕트 시스템 성능 개선)

  • Kim, Joon-Hyung;Choi, Young-Seok;Yoon, Joon-Yong;Park, Sung-Kwan;Hyun, Seok-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.4
    • /
    • pp.45-51
    • /
    • 2011
  • The kimchi refrigerator is the electronic home appliance which is used for the maturing and a custody of the kimchi. In this paper, performance improvement of fan and duct system for kimchi refrigerator has been studied by using a commercial CFD code. In order to achieve a improved fan performance, three-dimensional computational fluid dynamics and the Design of Experiments method have been applied. Additionally, to know the optimized duct inlet shape with the optimized fan, the overall performances were calculated with various duct inlet shapes. The final fan and duct system for kimchi refrigerator showed improved performance in efficiency and total head compared with the existing model.

Exploring Sweepstakes Marketing Strategies in Facebook Brand Fan Pages (페이스북 브랜드 팬 페이지의 경품 이벤트 마케팅 전략에 관한 탐색적 연구)

  • Choi, Yoon-Jin;Jeon, Byeong-Jin;Kim, Hee-Woong
    • The Journal of Information Systems
    • /
    • v.26 no.2
    • /
    • pp.1-23
    • /
    • 2017
  • Purpose Facebook is a social network service that has the highest number of Monthly Active Users around the world. Hence, marketers have selected Facebook as the most important platform to get customer engagement. With respect to the customer engagement enhancement, the most popular and engaging post type in the Facebook brand fan pages related to what was usually classified as 'sweepstakes'. Sweepstakes refer to a form of gambling where the entire prize may be awarded to the winner. Which makes customers more engaged with the brand. This study aims to explore sweepstakes-oriented social media marketing approaches based on the application of big data analytics. Design/methodology/approach we collect sweepstakes data from each company based on the data crawling from the Facebook brand fan pages. The output of this study explains how companies in each category of FCB grid can design and apply sweepstakes for their social media marketing. Findings The results show that they have one thing in common across the four quadrants of FCB grid. Regardless of the quadrants, most frequently observed type is 'Simple/Quiz or Comments/Quatrains [event type of sweepstakes] + Gifticon [type of reward prize] + Image [type of message display] + No URL [Link toother website] +Single-Gift-Offer [type of reward prize payment]'. So, if the position of the brand is hard to be defined by the FCB grid model, then this general rule can be applied to all types of brands. Also some differences between the quadrants of the FCB grid were observed. This study offers several research implications by analyzing Sweepstakes-oriented social media marketing approaches in Facebook brand fan pages. By using the FCB grid model, this study provides guidance on how companies can design their sweepstakes-oriented social media marketing approaches in the context of Facebook brand fan pages by considering their context.

Design of Miniaturized Wideband Tapered Slot Antenna Using Slots Combining Fan-shaped Structures (부채꼴 구조를 조합한 슬롯을 이용한 소형 광대역 테이퍼드 슬롯 안테나 설계)

  • Junho Yeo;Jong-Ig Lee
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.5
    • /
    • pp.629-634
    • /
    • 2023
  • In this paper, the design of a miniaturized wideband tapered slot antenna using slots combining various types of fan-shaped structures was studied. To miniaturize the tapered slot antenna and make it operate at low frequencies, slots combining fan-shaped structures were added to the ground plane of the tapered slot antenna. The miniaturization design process of the final proposed antenna was systematically explained by comparing the input reflection coefficient and gain variations when each fan-shaped structure was appended, compared to when there was no slot. The proposed miniaturized wideband tapered slot antenna using slots combining the fan-shaped structures was fabricated on an RF-35 substrate and its measured characteristics were compared with the simulation results. Experiment results show that the frequency band with a voltage standing wave ratio (VSWR) less than 2 was 2.59-11.39 GHz, and gain within the band was measured to be 3.3-7.0 dBi. The proposed miniaturized wideband tapered slot antenna can be reduced in size by 36.9%, compared to when there are no slots in the ground plane.

The Analysis of the Unsteady Flow Field and Aerodynamic Sound of Fan Motor in a Vacuum Cleaner (진공청소기용 팬 모터의 비정상 유동 해석 및 공력소음 해석)

  • 김재열;심재기;송경석;오성민;양동조;김우진
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.281-286
    • /
    • 2004
  • The vacuum cleaner motor runs on very high speed for the suction power. Specially, the motive power is provided by the impeller being rotate on very high speed. And centrifugal fan consists of the impeller, the diffuser, and the circular casing. Due to the high rotating speed or the impeller and small gap distance between the impeller and diffuser, the centrifugal fan makes very high noise level at BPF and harmonic frequencies. In order to calculate the sound pressure of centrifugal fan, the unsteady flow data is needed. And Noise cause is dividing to fluid noise by exhaust flow of fan and vibration noise by rotational vibration of vacuum cleaner fan motor. Until now, measuring method has been used to measure vibration by the accelerometer; this method has been not measured for the vibration in some parts of brush and commutator because of motor construction and 3-D vibrating mode. This paper was purposed on the accurate analysis, using laser vibration analyzer,. By using this measured data of noise cause against the difficult part in old times, we would like to use for the design of silent fan motor.

  • PDF