• Title/Summary/Keyword: Fan Blade

Search Result 358, Processing Time 0.027 seconds

Conceptual Study of a Low-Speed Wind Tunnel for Performance Test of Wind Turbine (풍력터빈 성능시험을 위한 저속풍동 개념연구)

  • Kang, Seung-Hee
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.19 no.4
    • /
    • pp.24-29
    • /
    • 2011
  • Conceptual study of an open-circuit type low-speed wind tunnel for performance test of wind turbine blade and airfoil is conducted. The tunnel is constituted of a settling chamber, a contraction, closed test section, a diffuser, two corners, a cross leg and a fan and motor. For the performance test, the closed test section width of 1.8 m, height of 1.8 m and length of 5.25 m is selected. The contraction ratio is 9 to 1 and maximum speed in the test section is 67 m/sec. Input power in the tunnel is about 238 kW and its energy ratio is 3.6. The wind tunnel designed in present study will be an effective tool in research and development of wind turbine and airfoil.

Transient Flow Characteristics of the Room Air Conditioner (룸에어컨 내부 유동의 과도현상에 대한 수치적 연구)

  • Seo, Hyeon-Seok;Kim, Jin-Baek;Kim, Youn-Jea
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.526-529
    • /
    • 2008
  • Air Conditioner has become a popular comfort providing device since two decades, whether in an office or home especially for warm and wet climate countries. The RAC (Room Air Conditioner) is widely used in various working spaces and residences. It composed of heat exchager, cross-flow fan, stabilizer, rearguider and blade of diffuser region, etc. In this study, numerical analyses based on the prediction of transient phenomena were carried out to investigate the flow characteristics in the RAC, including the impeller, the rearguider, the stabilizer and the blade of the diffuser region. Using a commercial code, FLUENT, the velocity, pressure and streamlines were obtained with unsteady, turbulent flow and no-slip condition. The angular velocities of impeller are located in the 900 rpm. Turbulent closure was achieved using a standard k-${\varepsilon}$ model. A moving reference frame (MRF) approach was adopted to simulate the flow field generated by impeller in the RAC. Results were graphically depicted with various geometrical configurations and operating conditions.

  • PDF

Numerical Simulation on the Performance of Axial Vane Type Gas-Liquid Separator with Different Guide Vane Structure

  • Yang, Fan;Liu, Ailan;Guo, Xueyan
    • International Journal of Fluid Machinery and Systems
    • /
    • v.10 no.1
    • /
    • pp.86-98
    • /
    • 2017
  • In order to obtain high efficiency and low resistance droplet separation apparatus, axial vane type gas-liquid separators with different guide vanes were designed, and the RNG $k-{\varepsilon}$ model as well as discrete phase model (DPM) were used to investigate the flow pattern inside the separators. It was shown that the tangential velocity distribution under different guide vanes have Rankine vortex characteristics, pressure distribution exhibits a high similarity which value becomes big as the increase of the blade outlet angle and the decrease of the guide vane numbers. The increase of the guide vane numbers and the decrease of the blade outlet angle could make separation improve significantly. The separation efficiency is almost 100% when the droplet diameter is bigger than $40{\mu}m$.

Selection of the Protective Coating Material for Blades of a Booster Fan in Desulfurization Plant (탈황설비용 부스터팬 블레이드의 코팅재질 선정에 관한 연구)

  • Jeong, Byeong-Yong;Yoo, Hoseon;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.6 no.3
    • /
    • pp.46-52
    • /
    • 2010
  • This study investigated the coating failure of the blades of booster fans for the 200 MW flue gas desulfurization plant. Although the arc sprayed SM8222 have been tried as blade coating materials aimed to apply as alternatives of Metcoloy(R)2 due to better corrosion-erosion resistance but it is failed. Bond strength tests and practical field experiences have demonstrated high velocity oxy-fuel(HVOF) coating method with Diamalloy 3004 as an alternative to Metcoloy(R) 2 arc spray.

  • PDF

A Study on the Flow Characteristics of an Axial Flow Fan by Unsteady Pressure Measurement (비정상 압력측정을 통한 축류휀 유동특성에 관한 연구)

  • Kang, Chang-Sik;Shin, You-Hwan;Kim, Kwang-Ho;Lee, Du-Yeol
    • The KSFM Journal of Fluid Machinery
    • /
    • v.5 no.3 s.16
    • /
    • pp.15-24
    • /
    • 2002
  • This paper presents an experimental study on the unsteady flow phenomena such as leakage flow and rotating stall which have influences on the performance and stability of an axial flow fan. For this study, unsteady pressure were measured using high frequency pressure transducers mounted on the easing wall of rotor passage and analyzed by Double Phase-Locked Averaging Technique. As the flow rate was reduced to near stall point, the pressure difference between the pressure and the suction side of the blade was increased especially new the leading edge and the lowest pressure zone of suction side was gradually developed. From the result of unsteady pressure field on the casing wall, one period of rotating stall was divided into three zones and the flow characteristics on each zone were described in detail.

A Study on the Identification of Aeroacoustic Noise and Noise Reduction for a Vacuum Cleaner (청소기의 공력소음 특성 파악 및 저소음화에 관한 연구)

  • 전완호;백승조;김창준;허남건
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.633-638
    • /
    • 2002
  • The vacuum cleaner that has no dust bag generates very high level annoying noise. The dominant noise source is the 2$\^$nd/ BPF tone of the rotating impeller. In order to reduce the noise, we identify the acoustic characteristics and reduce the noise of the vacuum cleaner and centrifugal fan. The resonance phenomenon is observed in blade passages and we found out that the resonance frequency is very close to the 2$\^$nd/ BPF. In order to reduce this high-level peak noise, new impeller is designed in this paper. The trailing edge of new impeller is inclined and this makes the flow interactions between the rotating impeller and the stationary diffuser vane occurs with some phase shift. The performance of new impeller is similar to the old one but the overall SPL is reduced about 3.6dBA. The SPL of BPF is reduced about 6dBA and 2$\^$nd/ BPF is reduced about 20dBA. The vacuum cleaner, which uses newly developed centrifugal fan, generate more comfortable noise than the old model and the strong tonal sound was dramatically reduced.

  • PDF

Comparative Study on the Film Cooling Effectiveness of 15° Angled Anti-Vortex Hole and 30-7-7 Fan-Shaped Hole Using PSP Technique (PSP를 이용한 15° 반와류 홀과 30-7-7 팬형상 홀의 막냉각 효율 비교 연구)

  • Kim, Ye Jee;Park, Soon Sang;Rhee, Dong Ho;Kwak, Jae Su
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.4
    • /
    • pp.13-18
    • /
    • 2016
  • The various film cooling hole shapes have been proposed for effective external cooling of gas turbine blade. In this study, the film cooling effectiveness by three different hole shapes (cylindrical hole, $15^{\circ}$ angle anti-vortex hole, 30-7-7 fan-shaped hole) were examined experimentally. Pressure Sensitive Paint (PSP) technique was used to measure the film cooling effectiveness. The coolant to mainstream density ratio was 1.0 and three blowing ratios of 0.5, 1.0, and 2.0 were considered. Results clearly showed that the effect of hole shape on the distribution of film cooling effectiveness. For the cylindrical hole case, the film cooling effectiveness decreased remarkably as the blowing ratio increased due to the jet lift off. Because of large hole exit area and low coolant momentum, the 30-7-7 fan-shaped hole case showed the highest film cooling effectiveness at all blowing ratio, followed by the anti-vortex hole case.

Study on Flow Structure inside Room Air Conditioner Using Visualization Technique (가시화기법을 이용한 룸 에어컨 내부의 유동 구조에 관한 연구)

  • Lee, Soo-Hong;Na, Seon-Uk;Kang, Geun;Ko, Han-Seo
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2713-2717
    • /
    • 2008
  • Whole flow fields of a room air conditioner (RAC) have been visualized by a Particle Image Velocimetry (PIV) technique to analyze the flow structure with various inlet and outlet angles, and to control an eccentric vortex which affects an efficiency and noise of the RAC. A test model with 5 stages of a cross flow fan has been manufactured and a transparent acryl has been installed at the side of the test model for the PIV experiment. The inlet and outlet flows and the flow inside the cross flow fan have been analyzed by varying the inlet grill angles and outlet blade angles. The movement of the eccentric vortex has been investigated experimentally by developing the measurement technique for the inner flow field of the cross flow fan. From the visualization of the inner flows, the origins of the noise inside the RAC and the condensation points around the outlet parts of the cold air have been observed and the solution of the problems can be proposed in this study.

  • PDF

Measurements of Minute Unsteady Pressure on Three-Dimensional Fan with Arbitrary Axis Direction

  • Hirata, Katsuya;Fuchi, Takuya;Onishi, Yusuke;Takushima, Akira;Sato, Seiji;Funaki, Jiro
    • International Journal of Fluid Machinery and Systems
    • /
    • v.3 no.1
    • /
    • pp.1-10
    • /
    • 2010
  • The present study is a fundamental approach to develop the measuring technology for minute fluctuating pressures on the three-dimensional blade surfaces of the fan which rotates with an arbitrary rotation-axis direction. In this situation, we are required to correct the centrifugal-force effect, the gravitational-force effect and the other leading-error effects for accurate measurements of the minute pressures. The working fluid is air. A pressure transducer rotating with an arbitrary attitude is closely sealed by a twofold shroud system. The rotational motion with an arbitrary attitude is produced by fixing the pressure transducer to the cantilever which is connected to a motor-driven disc of 500mm in diameter and 5mm in thickness. As a result, we have quantitatively determined main governing effects upon the non-effective component of the pressure-transducer signal.

A Study on the Structure of Instantaneous Flow Fields of a Small-Size Axial Fan by Large Eddy Simulation (대규모 와 모사에 의한 소형축류홴의 순간유동장 구조에 대한 연구)

  • Kim, Jang-Kweon;Oh, Seok-Hyung
    • Journal of Power System Engineering
    • /
    • v.22 no.6
    • /
    • pp.28-35
    • /
    • 2018
  • The large-eddy simulation (LES) was carried out to evaluate the instantaneous vector and vorticity profiles of a small-size axial fan (SSAF) at the operating point of full-flowrate. The downstream flow of the SSAF exhibits a shorter axial flow when not fully developed, especially the stronger vortex appears at the edge near the flow end. On the other hand, the downstream flow of the SSAF exhibits a longer axial flow, and the weaker vortex appears at the edge near the flow end when the flow is sufficiently developed. Moreover, in the downstream of the SSAF, a periodic and intermittent flow pattern appears at the edge showing the axial flow, and the instantaneous vorticity contour lines showing the form of a circle group are distributed at specific intervals from the downstream region of the blade tip, which is considered to be the result of the intermittency phenomenon influenced by the number of blades and the number of revolutions.