• 제목/요약/키워드: Failure rate test

검색결과 527건 처리시간 0.027초

가습기살균제 참사의 진행과 교훈(Q&A) (Questions and Answers about the Humidifier Disinfectant Disaster as of February 2017)

  • 최예용
    • 한국환경보건학회지
    • /
    • 제43권1호
    • /
    • pp.1-22
    • /
    • 2017
  • 'The worstest environment disaster', 'World's first biocide massacre', 'Home-based Sewol ferry disaster' are all phrases attached to the recent humidifier disinfectant disaster. In the spring of 2011, four of 8 pregnant women including 1 adult man passed away at a university hospital in Seoul due to breathing failure. Epidemiologic investigation conducted by the Korean CDC soon revealed the inhalation of humidifier disinfectant, which had been widely used in Korea during the winter, to be responsible for the disease. As well as lung fibrosis hardening of the lungs, other diseases including asthma, rhinitis, skin disease, liver disease, fetal disease or cancers have been researched for their relation with exposure to the products. By February 9, 2017, 5,342 cases had registered for health problems and 1,131 of them were already dead (20.8% mortality rate). Based on studies by government agencies and a telephone survey of the general population by Seoul National University and civic groups, around 20% of the general public of Korea has used these products. Since the market release of the first product by SK Chemical in 1994, over 7.1 million items from around 20 brands were sold up to 2011. Most of the products were manufactured by well-known large conglomerates such as SK, Lotte, Samsung, Shinsegye, LG, and GS, as well as some European companies including UK-based Reckitt Benckiser and TESCO, the German firm Henkel, the Danish firm KeTox, and an Irish company. Even though this disaster was unveiled in 2011 by the Korean government, the issue of the victims was neglected for over five years. In 2016, an unexpected but intensive investigation by prosecutors found that Reckitt Benckiser manipulated and concealed animal tests for its own brand and brought several university experts and company employees to court. The matter was an intense social issue in Korea from May to June with a surge in media coverage. The prosecutor's investigation and a nationwide boycott campaign organized by victims and environmental groups against Reckitt Benckiser, whose product had been used by more than 70% of victims, led to the producer's official apology and a compensation scheme. A legislative investigation organized after the April 2016 national election revealed the producers' faults and the government's responsibility, but failed to meet expectations. A special law for the victims passed the National Assembly in January 2017 and a punitive system together with a massive environmental epidemiology investigation are expected to be the only solutions for this tragedy. Sciences of medicine, toxicology and environmental health have provided decisive evidence so far, but for the remaining problems the perspectives of social sciences such as sociology and jurisprudence are highly necessary, similar to with the Minamata disease and Wonjin Rayon events. It may not be easy to follow this issue using unfamiliar terminology from medical and chemical science and the long, complicated history of the event. For these reasons the author has attempted to write this article in a question and answer format to render it easier to follow. The 17 questions are: Q1 What is humidifier disinfectant? Q2 What kind of health problems are caused by humidifier disinfectant? Q3 How many victims are there? Q4 What is the analysis of the 1,112 cases of death? Q5 What is the problem with the government's diagnostic criteria and the solution? Q6 Who made what brands? Q7 Has there been a recall? What is still on sale? Q8 Was safety not checked by any producers? Q9 What are the government's responsibilities? Q10 Is it true that these products were sold only in Korea? Q11 Why and how was it unveiled only in 2011 after 17 years of sales? Q12 What delayed the resolution of the victim issue? Q13 What is the background of the prosecutor's investigation in early 2016? Q14 Is it possible to report new victim cases without evidence of product purchase? Q15 What is happening with the victim issue? Q16 How does it compare with the cases of Minamata disease and Wonjin Rayon? Q17 Are there prevention measures and lessons?

자궁내막암의 수술 후 방사선치료 결과에 영향을 미치는 예후인자 (Prognostic Factors Influencing the Result of Postoperative Radiotherapy in Endometrial Carcinoma)

  • 기용간;권병현;김원택;남지호;윤만수;이형식;김동원
    • Radiation Oncology Journal
    • /
    • 제24권2호
    • /
    • pp.110-115
    • /
    • 2006
  • 목적: 수술 후 보조적으로 방사선치료를 받은 자궁내막암 환자의 전체생존율, 무병생존율, 재발 부위 등을 분석하여 이와 관련된 예후인자를 알아보고자 하였다. 대상 및 방법: 1992년 4월부터 2003년 5월까지 부산대학교병원에서 수술 후 방사선치료를 받은 자궁내막암 환자 중 조직유형이 선암인 환자 54명을 대상으로 후향적 분석하였다. 전체 환자의 중앙 나이는 55세(35-76세)였고, 병기 분포는 FIGO 병기 I군이 34명(63.0%), 병기 II군이 8명(14.8%), 병기 III군이 12명(22.2%)이었다. 모든 환자는 수술 및 외부 방사선조사($41.4{\sim}54.0Gy$, 중앙값 50.4 Gy)를 받았고, 20명(전체 환자의 37.0%)의 환자에서 추가로 질내 근접치료($15.0{\sim}24.0Gy$, 중앙값 15.0 Gy)를 받았다. 전체추적기간은 $5{\sim}115$개월로 중앙추적기간은 35개월이었다. 분석 결과 유의 인자로 나타난 조직 분화도(histologic grade), 림프-혈관 침범(Iymphovascular space invasion), 그리고 자궁근 침범 정도(myometrial invasion depth)를 점수화(GLM 점수)하여 생존분석을 시행하였다. 생존분석은 Ka-plan-Meter 법을, 단변량 및 다변량 통계분석은 각각 log-rank 검정과 Cox 회귀분석을 사용했다. 결과: 전체 자궁내막암 환자의 5년 생존율은 87.7%였고, 5년 무병생존율은 87.1%였다. 단변량 통계분석에서는 조직분화도, 림프-혈관 침범, 그리고 자궁근 침범 정도가 전체생존율 및 무병생존율과 관련 있는 인자였고, 다변량 통계분석에서는 림프-혈관 침범이 무병생존율과 관련 있는 인자였다(p=0.0158). GLM 점수는 전체생존율 및 무병생존율과 의미 있는 관계를 나타냈고(각각 p=0.0090, p=0.0073), 원격재발에도 유의한 예후인자로 나타났다 (p=0.0132). 전체 환자 중 6명(11%)의 환자에서 재발을 보였고, 재발 부위는 대동맥 림프절 2명, 폐 2명, 쇄골상부 림프절 1명, 질 1명이었다. 결론: 수술 및 수술 후 방사선치료를 받은 자궁내막암 환자의 예후는 수술 후의 병리 소견과 밀접한 관계를 가지고 있다. 더 많은 연구를 통해 자궁내막암 환자의 예후인자를 체계화한다면, 병의 진행양상을 예견하고 대처하는데 도움이 될 것이다.

급성대동맥해리에 대한 혈압강하요법으로서의 Nicardipine.HCI 주사액(Perdipine$^{circledR}$)의 유효성 및 안전성을 검토하기 위한 다기관 공동, 공개 제4상 임상시험 (Nicardipine Hydrochloride Injectable Phase IV Clinical Trial-Study on the antihypertensive effect and safely of nicardipine for acute aortic dissection)

  • 김경환;문인성;박장상;고용복;안혁
    • Journal of Chest Surgery
    • /
    • 제35권4호
    • /
    • pp.267-273
    • /
    • 2002
  • 배경: 저자들은 한국인에 있어서의 급성대동맥박리에 대한 nicardipine의 혈압강하요법에 대한 임상적 유용성을 검토하고자 국내 제4상 임상시험을 실시하였다. 대상 및 방법: 31명의 대동맥 질환 환자에서 시험약의 투여 전후의 수축기 및 이완기 혈압, 심박수 등을 시간변화에 따라 비교 관찰하였다. 시험약식 투여기간은 원칙적으로 3일 이상 14일 이하로 하였으며, 투여 3일째의 평균혈압강하도를 평가하였다. 시험약 사용전 다른 강압제를 사용하고 있었던 경우는 기존 사용약제의 용량을 줄이면서 시험약으로 대체하여 결국 기존 사용약제를 사용하지 않는 것을 원칙으로 하였다. 결과: 연구의 대상이 된 환자는 급성 대동맥 박리가 28명, 대동맥궁류 파열이 2명, 외상성 대동맥 파열이 1명이었다. 연령은 53.9$\pm$14.9(29~89)세였고, 남자가 21명 (67.7%)이었다. 대동맥질환에 기인한 합병증은 대동맥판 폐쇄부전이 7례, 혈성심낭 6례, 급성 신부전 1례, 하지마비 1례, 하지허혈 1례 등이었다. 목표혈압 도달은 15분이내가 16례로 가장 많았고, 15분이상 30분이내가 10명, 30분이상 45분이내가 3명, 45분이상 60분 이내에 도달한 경우가 2명이었다. 관찰기 혈압은 수축기혈압, 이완기혈안, 평균혈압이 각각 147$\pm$23mmHg, 82.3$\pm$18.6mmHg, 104$\pm$18mmHg이었고, 3일째 측정하였을 때 119$\pm$12mrnHg, 69$\pm$grnmHg, 86$\pm$BmmHg로 의미있게 감소하였음을 확인하였다. Nicardipine 투여 종료 시에측정한 수축기 혈압, 이완기혈압, 평균혈압은 각각 119$\pm$ 15mmHg, 70$\pm$ 14mmHg, 86$\pm$ 13mmHg로 3일째 측정한 혈압과 비교하였을 때 의미있는 상승 혹은 하강현상은 관찰되지 않았고 비교적 혈압 하강 상태가 잘 유지되고 있음을 알 수 있었다. 지속적 정맥 투여 중 부작용은 뚜렷하게 관찰할 수 없었다. 결론: 대동맥 박리에 동반된 고혈압에서 nicardipine을 사용하여 만족할만한 혈압하강 효과를 얻었으며, 뚜렷한 부작용이 없이 안전하게 사용할 수 있다는 결론을 내렸다.

비즈니스 모델 혁신 프레임워크 기반의 액셀러레이터 투자결정요인 실증 분석 (Empirical Analysis of Accelerator Investment Determinants Based on Business Model Innovation Framework)

  • 정문수;김은희
    • 벤처창업연구
    • /
    • 제18권1호
    • /
    • pp.253-270
    • /
    • 2023
  • 스타트업에게 전문보육과 투자를 동시에 제공함으로써 스타트업의 생존율을 크게 개선하여 주목을 받고 있는 액셀러레이터의 투자결정요인에 대한 연구는 점점 확대되고 있다. 그러나 선행 연구들은 초기 단계로 투자결정요인 개발 시 이론적 기반을 갖추지 못한 상황으로 유사 투자자인 엔젤투자자나 벤처캐피탈의 투자결정요인을 사용하고 있으며 실증연구를 통해 중요도와 우선순위를 분석하는 단계에 머물고있다. 따라서 본 연구는 선행연구에서 비즈니스 모델 혁신 프레임워크를 기반으로 개발된 액셀러레이터 투자결정요인을 사용하여 투자결정요인의 변별력과 유효성을 국내 최초로 실증 검증하였다. 이를 위해 먼저 액셀러레이터의 스타트업 투자 성공과 실패의 판단 기준을 스케일업 이론을 기반으로 설정한 후 국내 14개 액셀러레이터의 22명의 투자전문가를 대상으로 설문조사를 시행한 결과 액셀러레이터의 스타트업 투자 후 스케일업에 성공한 스타트업 52개사, 스케일업에 실패한 스타트업 45개사 등의 총 97개 스타트업의 유효한 자료를 확보하였으며 이 두 그룹 간의 액셀러레이터 투자결정요인별 평균 차이를 검증하기 위해 독립표본 t-검정을 실시하였다 분석 결과 총 21개의 투자결정요인 중 9개(43%) 요인에서 평균 차이를 확인함으로써 비즈니스 모델 혁신 프레임워크 기반의 액셀러레이터의 투자결정요인이 실무적으로 액셀러레이터가 성공 가능한 스타트업을 발굴하고 투자의사결정을 하는데 상당한 변별력을 보유한 것으로 확인하였다. 또한 스타트업의 업종별 혁신의 특성을 고려하여 연구 대상 스타트업 표본을 제조업 분야 스타트업과 서비스업 분야 스타트업으로 구분하여 분석한 결과 제조업 분야 스타트업에서는 비즈니스 모델, 전략, 동적역량 요인에서 평균 차이가 발생한 반면 서비스업 분야 스타트업은 동적역량 요인에서만 평균 차이가 발생하였다. 본 연구는 비즈니스 모델 혁신 프레임워크를 기반으로 도출한 액셀러레이터 투자결정요인의 실무적 유효성을 실증연구를 통해 국내 최초로 검증하였다는 점에서 학문적 시사점이 크며, 액셀러레이터에게 투자의사결정을 위한 이론적 근거와 세부 투자결정요인에 대한 구체적인 정보를 제공함으로써 효과적인 투자를 할 수 있게 한다는 점에서 실무적 가치가 높다.

  • PDF

폐국균종의 임상적 고찰 (Clinical Characteristics of Pulmonary Aspergilloma)

  • 강태경;김창호;박재용;정태훈;손정호;이준호;한승범;전영준;김기범;정진홍;이관호;이현우;신현수;이상채;권삼
    • Tuberculosis and Respiratory Diseases
    • /
    • 제44권6호
    • /
    • pp.1308-1317
    • /
    • 1997
  • 연구배경 : 폐국균종은 대부분 기존에 존재하는 공동성 폐병소에 이차적인 감염을 일으켜 주위조직의 침윤없이 집락을 형성하고 국소성장으로 균구을 보이는 질환으로 공동성 폐결핵환자의 약 15%에서 합병되는 것으로 알려져 있다. 지금까지의 국내보고는 주로 증례나 소수예에 대한 보고가 대부분이었기에 저자들은 대구 4개 대학병원에서 폐국균종으로 진단된 91예를 대상으로 임상적 특성을 알아보고자 하였다. 방 법 : 1986년 6월부터 1996년 5월까지 10년간 대구지역의 4개 대학병원에서 단순흉부촬영, 전산화단층촬영, 국균에 대한 혈청침강반응검사 및 생검을 통해 폐국균종으로 진단받은 91예를 대상으로 임상적 특성에 대한 후향적조사를 실시하였다. 총 91예중 10예(11.0%)는 임상적으로, 81예(89.0%)는 조직학적인 방법에 의하여 진단하였다. 결 과 : 1) 대상환자의 평균연령은 $45{\pm}12.04$세였고 연령 분포는 22세에서 65세까지였으며 남녀비는 남자 57예, 여자 34예로 1.7 : 1 이었다. 2) 증상은 객혈이 81예(89.0%)로 가장 흔했으며 기침, 호흡곤란, 무기력 체중감소, 발열, 흉통의 순이었다. 3) 기저질환은 폐결핵이 68예(74.7%), 기관지확장증 6예(6.6%), 공동성 종양 2예(2.2%), 폐 격리증 1예(1.1%)의 순이었으며, 14예(15.4%)는 원인 미상이었다. 4) 호발부위는 우상엽이 39예(42.9%), 좌상엽이 31예(34.1%)로 주로 상엽에 위치하였고 그밖에 좌하엽 13예(14.3%), 우하엽 7예(7.7%), 우중엽 1예(1.1%)의 빈도를 보였다. 5) 전체예중 단순흉부사진상에서는 57예(62.6%)에서, 전산화단층촬영을 같이 시행한 59 예중에서는 단순흉부사진에서 36예(61.0%)만이 발견되었으나, 전산화단층사진에서는 52예(88.1%)에서 전형적인 균구가 관찰되었다. 6) 대상환자 91예중 76예는 외과적 절제를 시행하였고, 공동내 항진균제 주입을 받은 4예를 포함한 15예에서는 내과적 치료를 받았다. 7) 수술적 절제방법은 폐엽절제 55예(72.4%), 폐구역절제 16예(21.1%), 전폐절제 4예(5.3%), 설절제 1예(1.3%)의 순이었으며, 수술에 따른 사망은 3예(3.9%)로 패혈증 2예와 객혈 1예였고, 술후합병증은 호흡부전, 출혈, 기관지흉막루, 농흉, 성대마비 각각 1예로 모두 6예(7.9%)였다. 8) 경과관찰이 가능했던 81예는 절제술후의 71예와 내과적 치료군의 10예였으며 각각 2예(2.7% vs 18.1%)씩의 재발성객혈을 보였다. 결 론 : 만성폐질환, 특히 폐결핵의 경과관찰중 단순흉부사진상에서 특징적인 균구의 소견이 관찰되지 않더라도 의심되는 환자에서는 추가적인 전산화단층촬영사진과, 또한 감별 및 임상적 진단을 위하여 혈청침강반응검사의 적극적인 활용이 필요하리라 생각된다. 그리고 외과적 절제술은 생명을 위협하는 대량객혈이나 반복성의 객혈에서 선택적으로 시행되어야 하며 공동내 항진균제 주입 등의 내과적 치료는 대조군과의 비교연구에 의한 재평가가 필요할 것으로 생각한다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF