• Title/Summary/Keyword: Failure rate test

Search Result 527, Processing Time 0.027 seconds

Characterization of Partial Interfacial Fracture on Resistance Spot-Welded TRIP Steels for Automotive Applications (자동차 차체용 TRIP강판의 저항 점용접부 Partial Interfacial Fracture 특성에 관한 연구)

  • Choi, Chul Young;Kim, In-Bae;Kim, Yangdo;Park, Yeong-Do
    • Korean Journal of Metals and Materials
    • /
    • v.50 no.2
    • /
    • pp.136-145
    • /
    • 2012
  • Resistance spot welding of TRIP780 steels was investigated to enhance understanding of weld fracture mode after tensile shear testing (TST) and L-shape tensile testing (LTT). The main failure mode for spot welds of TRIP780 steels was partial interfacial fracture (PIF). Although PIF does not satisfy the minimum button diameter (4${\surd}$t) for acceptable welds, it shows enough load carrying capacity of resistance spot welds for advanced high strength steels. In the analysis of displacement controlled L-shape tensile test results, cracks initiated at the notch of the faying surface and propagated through the interface of weldments, and finally, cracks change path into the sheet thickness direction. Use of the ductility ratio and CE analysis suggested that the occurrence of PIF is closely related to high hardness and brittle welds, which are caused by fast cooling rates and high chemical compositions of TRIP steels. Analysis of the hold time and weld time in a welding schedule demonstrated that careful control of the cooling rate and the size of a weld nugget and the HAZ zone can reduce the occurrence of PIF, which leads to sound welds with button fractures (BFs).

A Study on the Design Verification by Using Finite Elements Method and Quality Improvement of Radar by Managing Change Points of 4M (유한요소 기법을 활용한 설계검증 및 4M 변경점 관리를 통한 레이더장비 품질 신뢰성 확보에 관한 연구)

  • Jo, Hee Jin;Pak, Se Jin;Lee, Nam Ho;Jung, Won Yong
    • Journal of Korean Society for Quality Management
    • /
    • v.47 no.3
    • /
    • pp.437-451
    • /
    • 2019
  • Purpose: The purpose of this study is to improve the quality of the PGM system by improving the structure and production process of slip-ring rotary joint for radar. Methods: The improvement measures for each cause are established through failure analysis of broken items. Specifically, changing in the housing to improve the heating system. Changing the transportation method to prevent damage to equipment during transport. Changing work process of the attenuator ring to prevent damage. etc. Results: The results of this study are as follows; improving the heating system reduces heat generated by the attenuator by about 7 degrees and obtain additional temperature margins. Reduction of defect rate because of adding X-band rotary joint run-out measurement test, ESS of slip-ring rotary joint and Transportation improvement(reinforced flight boxes, tube protection, etc). Getting stable VSWR values by improving work process of attenuator overheating due to a bad bonding process. Conclusion: Through this study, improvements were made to slip-ring rotary joint that failed repeatedly for various reasons. As a result of the application of the improvements, the same fault does not occur until now, so we can see that the quality of PGM has improved.

A Study on the Chilling Start-up Characteristics and Performance of a Gas Loaded Heat Pipe (가스내장 히트파이프의 냉시동특성과 성능에 관한 연구)

  • Hong, Sung-Eun;Kang, Hwan-Kook
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.11
    • /
    • pp.915-922
    • /
    • 2006
  • Considering heat pipe design principles in fabrication and operational performances, water is one of the most recommended working fluids to make mid to low tempera lure heat pipes. But the conventional water heat pipes might encounter the failure in a cold start-up operation when socked at a chilling temperature lower than the freezing point. If they are subjected to a heat supply for start-up at a temperature around $-20^{\circ}C$, the rate of the vapor flow and the corresponding heat transfer from the evaporator to the condenser is so small that the vapor keeps to stick on the surface of the chilling condenser wall, forming an ice layer, resulting in a liquid deficiency in the evaporator. This kind of problems was resolved by Kang et al. in 2004 by adopting a gas loading heat pipe technology to the conventional water heat pipes. This study was conducted to examine a chilling start-up procedure of gas loading heat pipes by investigating the behaviors of heat pipe wall temperatures. And the thermal resistance of the gas loaded heat pipe that depends on the operating temperatures and heat loads was measured and examined. Two water heat pipes were designed and fabricated for the comparison of performances, one conventional and the other loaded with $N_2$ gas. They were put on start-up test at a heat supply of 30 W after having been socked at an initial temperature around $-20^{\circ}C$. It was observed that the gas loaded one had succeeded in chilling start-up operation.

Estimation Method of Infiltration Capacity for Assessment of Drainage Capacity I (배수성능 평가를 위한 침투능 산정기법에 관한 연구 I)

  • Jeong, Jisu;Shim, Jeonghoon;Hwang, Youngcheol;Lee, Seungho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.12
    • /
    • pp.49-55
    • /
    • 2019
  • Slope failure analysis entails proper understanding of various factors as well as the characteristics of ground conditions, which are difficult to achieve due to technological limits. Despite a number of past studies to clarify possible factors triggering slope failures, the impact of rainfall characteristics and infiltration rate, which are the key to estimation of slope stability in wet condition, on slope failures still remains unclear. This study has estimated permeability against various unit weights of soil based on constant head permeability tests using Jumunjin standard silica sand. One dimensional infiltration tests were conducted to estimate the infiltration capacity and the amount of infiltration taking into account the permeability and rainfall intensity. The applicability of existing empirical equations for the estimation of infiltration to granular soils was verified on the basis of the test results.

Antibacterial activity of enrofloxacin loaded gelatin-sodium alginate composite nanogels against intracellular Staphylococcus aureus small colony variants

  • Luo, Wanhe;Liu, Jinhuan;Algharib, Samah Attia;Chen, Wei
    • Journal of Veterinary Science
    • /
    • v.23 no.3
    • /
    • pp.48.1-48.12
    • /
    • 2022
  • Background: The poor intracellular concentration of enrofloxacin might lead to treatment failure of cow mastitis caused by Staphylococcus aureus small colony variants (SASCVs). Objectives: In this study, enrofloxacin composite nanogels were developed to increase the intracellular therapeutic drug concentrations and enhance the efficacy of enrofloxacin against cow mastitis caused by intracellular SASCVs. Methods: Enrofloxacin composite nanogels were formulated by an electrostatic interaction between gelatin (positive charge) and sodium alginate (SA; negative charge) with the help of CaCl2 (ionic crosslinkers) and optimized by a single factor test using the particle diameter, zeta potential (ZP), polydispersity index (PDI), loading capacity (LC), and encapsulation efficiency (EE) as indexes. The formation mechanism, structural characteristics, bioadhesion ability, cellular uptake, and the antibacterial activity of the enrofloxacin composite nanogels against intracellular SASCVs strain were studied systematically. Results: The optimized formulation was comprised of 10 mg/mL (gelatin), 5 mg/mL (SA), and 0.25 mg/mL (CaCl2). The size, LC, EE, PDI, and ZP of the optimized enrofloxacin composite nanogels were 323.2 ± 4.3 nm, 15.4% ± 0.2%, 69.6% ± 1.3%, 0.11 ± 0.02, and -34.4 ± 0.8 mV, respectively. Transmission electron microscopy showed that the enrofloxacin composite nanogels were spherical with a smooth surface and good particle size distributions. In addition, the enrofloxacin composite nanogels could enhance the bioadhesion capacity of enrofloxacin for the SASCVs strain by adhesive studies. The minimum inhibitory concentration, minimum bactericidal concentration, minimum biofilm inhibitory concentration, and minimum biofilm eradication concentration were 2, 4, 4, and 8 ㎍/mL, respectively. The killing rate curve had a concentration-dependent bactericidal effect as increasing drug concentrations induced swifter and more radical killing effects. Conclusions: This study provides a good tendency for developing enrofloxacin composite nanogels for treating cow mastitis caused by intracellular SASCVs and other intracellular bacterial infections.

Shear strengthening of reinforced concrete beams with minimum CFRP and GFRP strips using different wrapping technics without anchoring application

  • Aksoylu, Ceyhun
    • Steel and Composite Structures
    • /
    • v.44 no.6
    • /
    • pp.845-865
    • /
    • 2022
  • In this study, the performance of shear deficient reinforced concrete (RC) beams with rectangular cross-sections, which were externally bonded reinforced (EBR) with high strength CFRP and GFRP strips composite along shear spans, has been experimentally and analytically investigated under vertical load. In the study, the minimum CFRP and GFRP strips width over spacing were considered. The shear beam with turned end to a bending beam was investigated by applying different composite strips. Therefore various arising in each of strength, ductility, rigidity, and energy dissipation capacity were obtained. A total of 12 small-scaled experimental programs have been performed. Beam dimensions have been taken as 100×150×1000 mm. Four beams have been tested as unstrengthened samples. This paper focuses on the effect of minimum CFRP and GFRP strip width on behaviours of RC beams shear-strengthened with full-wrapping, U-wrapping, and U-wrapping+longitudinal bonding strips. Strengthened beams showed significant increments for flexural ductility, energy dissipation, and inelastic performance. The full wrapping strips applied against shear failure have increased the load-carrying capacity of samples 53%-63% interval rate. Although full wrapping is the best strengthening choice, the U-wrapping and U-wrapping+longitudinal strips of both CFRP and GFRP bonding increased the shear capacity by 53%~75% compared to the S2 sample. In terms of ductility, the best result has been obtained by the type of strengthening where the S5 beam was completely GFRP wrapped. The experimental results were also compared with the analytically given by ACI440.2R-17, TBEC-2019 and FIB-2001. Especially in U-wrapped beams, the estimation of FIB was determined to be 81%. The estimates of the other codes are far from meeting the experimental results; therefore, essential improvements should be applied to the codes, especially regarding CFRP and GFRP deformation and approaches for longitudinal strip connections. According to the test results, it is suggested that GFRP, which is at least as effective but cheaper than CFRP, may be preferred for strengthening applications.

Flexural Behavior of RC Beam After Completion of Electrochemical Chloride Extraction (전기화학적 염화물 추출 후 철근-콘크리트 보의 휨 거동)

  • Jung Wook Lee;Ki Yong Ann
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.4
    • /
    • pp.484-492
    • /
    • 2023
  • The structural behaviour of concrete beam was examined by the three points bending test after the completion of the electrochemical chloride extraction (ECE), rather than bond strength mostly measured in previous studies. It was found that the flexural rigidity of concrete was lowered by the ECE, but the strength was enhanced in terms of the maximum load.The flexural rigidity, in the linear elastic range, was reduced by the loss of effective cross-section area. In fact, the inertia moment was substantially subjected to 70 % loss of the cross-section by the tensile strain at the condition of the failure. However, a lower rate of the inertia moment reduction was achieved by the ECE, implying the higher resistance to the cracking, but the higher risk of deformation.

Modified Blalock-Taussig Shunt in Neonates (신생아에서 변형 Blalock-Taussig 단락술)

  • 조광조;성시찬
    • Journal of Chest Surgery
    • /
    • v.30 no.4
    • /
    • pp.378-382
    • /
    • 1997
  • To evaulate the effectiveness and risk factors for shunt failure of the Blalock-Taussig shunt in neonates, we analyzed the 21 neonates who were undergone Blalok-Taussig shunt operation at Dong-A University Hospital from December 1991 to Feburary 1996. We evaluated operative mortality, patency of the shunt. and distortion of pulmonary artery. We also determined the risk factors for the shunt failure. Age at operation was from 1 day to 30 days(mean 11.7 days). We ghts were 2.4 to 4.5kg(mean 3.1 kg). The underlying lesions included severe tetralogy of Fallot with pulmonary stenosls or atresia(N=11) and single ventricle varieties with. pulmonary stenosis or atresia(N=10). Prostaglandin El was given in 13 neonates prior to operation. The mean preoperative(prior to prostaglandin El therapy) and postoperative arterial oxygen tension were 30.1 mmHg and 46.3 mmHg respectively(P(0.01). The shunt was performed through a left thoracotomy in 11 patients and through a right thoracotomy In 10. A 5 mm graft was used in 15 patients and a 4 mm graft in 6 patients. The incidence of early shunt occlusion was 9.5%(2 patients). The hospital mortality was 9.5%(2 patients with early shunt occlusion). Univariate analysis revealed that body weight of 2.6 kg or less(p=0.021), pulmonary artery size of 3mm or less(p=0.008), and 4 mm graft (p=0.021) were risk factors predictive of early shunt failure. The patency rate of the shunt in hospital survivors was 100% at mean ollow-up of ll.3 months(There was not death or reoperation related to shunt failure). 10 patients were catheterized during postoperative follow-up. There was no significant distorsion of pulmonary artery. So we concluded that the modified Blalock-Taussig shunt in neonates was excellent in the hospital survivors.

  • PDF

EFFECT OF TEMPORARY CEMENT ON TENSILE BOND STRENGTH OF DENTIN BONDING AGENT (Temporary Cement가 상아질 접착제의 접착성능에 미치는 영향)

  • Chang, Heon-Soo;Cho, Kyeu-Zeung
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.685-698
    • /
    • 1995
  • This study was conducted to the effect of temporary cement on the adhesiveness of dentin bonding agent to dentin surface. One hundred freshly extracted bovine mandibular incisors were grinded to expose flat labial dentin surface. The dentin surfaces were temporarized with either eugenol-containing temporary cement(TemBond and Zinc Oxide Eugenol cement) or non-eugenol temporary cement(Nogenol and TempBond NE) for 7days, and then the temporarization was removed with surgical currette and the exposed dentin surfaces were water-rinsed. Bonding specimens were made by use of All-Bond 2 and Super-Bond C&B dentin bonding agent, and stored in $37^{\circ}C$ distilled water for 24hours. The tensile bond strenth and the cohesive failure rate were measured, and then the pretreated dentin surfaces which the temporary cement had been applied to and removed from and the fractured dentin surfaces after bonding test were examined under scanning electron microscope. The results were as follows : In case of bonding with All-Bond 2, tensile bond strength of each experimental group was lower than that of the control group(p<0.05), but there was no significant difference between the bond strengths of the control group and each experimental group in case of bonding with Super-Bond C&B(p>0.05). No significant difference between tensile bond strength of experimental group, whether temporary cement contains eugenol or not, was seen(p>0.05). In case of bonding with All-Bond 2, the control group showed cohesive-adhesive mixed failure mode and the experimental groups mainly showed adhesive failure mode, but in case of bonding with Super-Bond C&B, almost of the control and the experimental groups mainly showed cohesive failure mode. On SEM examination, all of the dentin specimens pretreated with either 10 % phosphoric acid or 10% citric acid after application of the temporary cements demonstrated remnants of temporary cement attached to dentin surface.

  • PDF

Postoperative Clinical Courses According to the Length of Preoperative Drug Therapy in Pulmonary Tuberculosis (폐결핵 환자의 수술전 항결핵제 투여기간에 따른 수술후 임상경과)

  • Kwon, Eun-Su;Kim, Dae-Yun;Park, Seung-Kyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.6
    • /
    • pp.775-785
    • /
    • 1999
  • Background : Though surgery plays an important role in the management of patients with Mycobacterium tuberculosis infection, there is little information regarding the timing of resection. We tried to find out the ideal timing of operation. Method: A retrospective review was performed in 69 patients underwent pulmonary resection for pulmonary tuberculosis between January 1993 and December 1997. They were categorized into various groups according to the length of preoperative specific drug therapy. The rates of treatment failure, realpse and complication in each group were compared statistically by $x^2$-test. Results: Eighty one point two percent were men and 18.8 % women with a median age of 33 years(range, 16 to 63 years). The mean number of resistant drugs was 3.l(range, 0 to 9). Patients were treated preoperatively with multidrug regimens, which mean number of preoperative specific drugs was 4.6, in an effort to reduce the mycobacterial burden with the mean length of preoperative drug therapy, 5.0 months. Postoperative treatment was conducted for a mean period of 13.0 months with a mean number of postoperative specific drugs, 4.4. Postoperative treatment failures were confirmed in 8 among 69 patients(11.6%). 2 of these 8 patients were showed up in the preoperative 3 to 4 months medication group and each of the rest was occurred in the preoperative 2 to 3, 5 to 6, 6 to 7, 12 to 13, 17 to 18 months, less than one month medication group, respectively. 59 of 69 patients were available for evaluation of the relapse rate with the mean duration of the postoperative follow-up, 19.8 months. In 4 patients bacterial relapse was confirmed(6.8%). Each of these 4 was in the preoperative 1 to 2, 2 to 3, 3 to 4, 5 to 6 months medication group. Categorized into various groups according to the length of preoperative specific therapy, there were no statistical significances of the treatment failure rate, relapse rate and complication rate in the groups. There were seven treatment failures of 28 who were AFB culture positive until the time of operation(25%, p<0.01). Categorized the preoperative AFB culture positive group into various groups according to the length of preoperative drug therapy, there were no statistical significances, either. Conclusion: We believe that operation plays an important ancillary role in the treatment of pulmonary tuberculosis. Our results indicate that the timing of resection according to the length of preoperative drug therapy may not cause trouble.

  • PDF