• 제목/요약/키워드: Failure of fixation

검색결과 161건 처리시간 0.017초

Risk Factors Associated with Fixation Failure in Intertrochanteric Fracture Treated with Cephalomedullary Nail

  • Hyung-Gon Ryu;Dae Won Shin;Beom Su Han;Sang-Min Kim
    • Hip & pelvis
    • /
    • 제35권3호
    • /
    • pp.193-199
    • /
    • 2023
  • Purpose: Cephalomedullary (CM) nailing is widely performed in treatment of elderly patients with femoral intertrochanteric fractures. However, in cases of fixation failure, re-operation is usually necessary, thus determining factors that may contribute to fixation failure is important. In this study, we examined factors affecting the occurrence of fixation failure, such as age or fracture stability, after CM nailing in elderly patients. Materials and Methods: This study was conducted retrospectively using registered data. From April 2011 to December 2018, CM nailing was performed in 378 cases diagnosed with femoral intertrochanteric fractures, and 201 cases were finally registered. Cases involving patients who were bed-ridden before injury, who died from causes unrelated to surgery, and those with a follow-up period less than six months were excluded. Results: Fixation failure occurred in eight cases. Comparison of the surgical success and fixation failure group showed that the mean age was significantly higher in the fixation failure group compared with the control group (81.3±6.4 vs. 86.4±6.8; P=0.034). A significantly high proportion of unstable fractures was also observed (139/54 vs. 3/5; P=0.040), with a significantly high ratio of intramedullary reduction (176/17 vs. 5/3; P=0.034). A significantly higher ratio of unstable fractures compared with that of stable fractures was observed in the intramedullary reduction group (132/49 vs. 10/10; P=0.033). Conclusion: Fixation failure of CM nailing is likely to occur in patients who are elderly or have unstable fracture patterns. Thus, care should be taken in order to avoid intramedullary reduction.

Surgical Management of a Mandible Subcondylar Fracture

  • Kang, Dong Hee
    • Archives of Plastic Surgery
    • /
    • 제39권4호
    • /
    • pp.284-290
    • /
    • 2012
  • Open reduction and anatomic reduction can create better function for the temporomandibular joint, compared with closed treatment in mandible fracture surgery. Therefore, the double miniplate fixation technique via mini-retromandibular incision was used in order to make the most stable fixation when performing subcondylar fracture surgery. Those approaches provide good visualization of the subcondyle from the posterior edge of the ramus, allow the surgeon to work perpendicularly to the fracture, and enable direct fracture management. Understanding the biomechanical load in the fixation of subcondylar fractures is also necessary in order to optimize fixation methods. Therefore, we measured the biomechanical loads of four different plate fixation techniques in the experimental model regarding mandibular subcondylar fractures. It was found that the loads measured in the two-plate fixation group with one dynamic compression plate (DCP) and one adaption plate showed the highest deformation and failure loads among the four fixation groups. The loads measured in the one DCP plate fixation group showed higher deformation and failure loads than the loads measured in the two adaption plate fixation group. Therefore, we conclude that the selection of the high profile plate (DCP) is also important in order to create a stable load in the subcondylar fracture.

전 십자 인대 재건술에서 대퇴골측 고정 방법의 초기 안정성의 비교 (Comparison of Primary Stability of Different Femoral Fixation Techniques in Anterior Cruciate Ligament Reconstruction)

  • 송은규;이근배;이문
    • 대한관절경학회지
    • /
    • 제2권1호
    • /
    • pp.85-92
    • /
    • 1998
  • Various methods for fixation of graft have been widely used for reconstruction of anterior cruciate ligament. However, the biomechanical strength of each fixation techniques are not fully understood. The purpose of this study is to compare the pull out strength of different fixation techniques which is probably the most important factor for the success at the initial stage of healing. Biomechanical test was carried out to measure and compare the pull out tensile strength of five different fixation techniques in 35 pig(Yorkshire) knees. ANOVA and Duncan multiple comparison test was applied for statistical analysis. In the two fixation techniques with bone patellar tendon bone graft, the mean maximum tensile strength was $1333.4{\pm}148.5N$ with titanium interference screw, while it was $1310.1{\pm}168.9N$ with biodegradable interference screw. The failure mode were pulled out of bone plugs from the femoral tunnel in majority cases. In the fixations with hamstring tendon, the mean maximum tensile strength were $1405.9{\pm}135.1N$ with SemiFix screw, $820.3{\pm}104.5N$ with biodegradable interference screw, and $682.1{\pm}54.2N$ with Endobutton. The mode of failure was variable in each technique. The tendon was pulled out from the tunnel in biodegradable interference screw fixation, the screw was bent in the SemiFix system, and the polyester tape were ruptured or the buttons were pulled into tunnel in Endobutton fixation. The mean maximum tensile strength of two interference screws with bone patellar tendon bone was statistically comparable to that of SemiFix with hamstring tendon. However biodegradable interference screw and Endobutton with hamstring tendon showed weaker maximum tensile strength than above three fixation techniques (P<0.05).

  • PDF

하악골 과두하부 골절 실험모델에서 견고정을 위한 플레이트 고정방법 연구 (Study of the Plating Methods in the Experimental Model of Mandibular Subcondyle Fracture)

  • 이원;강동희
    • 대한두개안면성형외과학회지
    • /
    • 제12권1호
    • /
    • pp.12-16
    • /
    • 2011
  • Purpose: This study examined the biomechanical stability of four different plating techniques in the experimental model of mandibular subcondyle fracture. Methods: Twenty standardized bovine tibia bone samples ($7{\times}1.5{\times}1.0cm$) were used for this study. Each of the four sets of tibia bone was cut to mimic a perpendicular subcondyle fracture in the center area. The osteotomized tibia bone was fixed using one of four different fixation groups (A,B,C,D). The fixation systems included single 2.0 mm 4 hole mini adaption plate (A), single 2.0 mm 4 hole dynamic compression miniplate (B), double fixation with 2.0 mm 4 hole mini adaption plate (C), double fixation with a 2.0 mm 4 hole mini adaption plate and 2.0 mm 4 hole dynamic compression miniplate (D). A bending force was applied to the experimental model using a pressure machine (858 table top system, $MTS^{(R)}$) until failure occurred. The load for permanent deformation, maximum load of failure were measured in the load displacement curve with the chart recorder. Results: Double fixation with a 2.0 mm 4 hole mini adaption plate and a 2.0 mm 4 hole dynamic compression miniplate (D) applied to the anterior and posterior regions of the subcondyle experimental model showed the highest load to failure. Conclusion: From this study, double fixation with an adaption plate and dynamic compression miniplate fixation technique produced the greatest biomechanical stability. This technique may be considered a useful means of fixation to reduce the postoperative internal maxillary fixation period and achieve early mobility of the jaw.

Akin 절골술의 내측 횡 봉합사 고정: 술기 보고 (Medial Horizontal Suture Fixation of the Akin Osteotomy: A Technical Report)

  • 윤영필;김상환
    • 대한족부족관절학회지
    • /
    • 제19권4호
    • /
    • pp.197-200
    • /
    • 2015
  • The Akin osteotomy is a complimentary procedure in hallux valgus surgery. Surgical techniques may vary depending on the operators or fixation devices. Suture fixation, for which a removal procedure is not necessary, can often be recommended. However, there is a risk of failure due to the thin cortex of the phalanx. We describe a new technique using Ethibond suture fixation in Akin osteotomy, which can lower the risk of phalangeal cortical failure and articular cartilage irritation. First, the Akin osteotomy was performed on the proximal phalanx 5 to 6 mm distal to the first metatarsophalangeal joint. Then bone holes were drilled from dorsum to plantar parallel to osteotomy with the Kirschner wire. The final procedure involved passing the Ethibond sutures connected to a straight needle through the holes and tying it. This fixation method offers an effective and easy technique for performance of Akin osteotomy.

Long-term Follow-up Results of Short-segment Posterior Screw Fixation for Thoracolumbar Burst Fractures

  • Lee, Yoon-Soo;Sung, Joo-Kyung
    • Journal of Korean Neurosurgical Society
    • /
    • 제37권6호
    • /
    • pp.416-421
    • /
    • 2005
  • Objective: Despite general agreement on the goals of surgical treatment in thoracolumbar burst fractures, considerable controversy exists regarding the choice of operative techniques. This study is to evaluate the efficacy of short-segment fixation for thoracolumbar burst fractures after long-term follow-up and to analyze the causes of treatment failures. Methods: 48 out of 60 patients who underwent short-segment fixation for thoracolumbar burst fractures between January 1999 and October 2002 were enrolled in this study. Their neurological status, radiological images, and hospital records were retrospectively reviewed. Simple radiographs were evaluated to calculate kyphotic angles and percentages of anterior body compression (%ABC). Results: The average kyphotic angles were $20.0^{\circ}$ preoperatively, $9.6^{\circ}$ postoperatively, and $13.1^{\circ}$ at the latest follow-up. The average %ABC were 47.3% preoperatively, 31.2% postoperatively, and 33.3% at the latest follow-up. The treatment failure, defined as correction loss by $10^{\circ}$ or more or implant failure, was detected in 6 patients (12.5%). 5 out of 6 patients had implant failures. 2 out of 5 patients were related with osteoporosis, and the other 2 were related with poor compliance of spinal bracing. 3 patients with poor initial postoperative alignment had implant failure. 4 patients with screws only on the adjacent vertebrae and not on the injured vertebra itself showed poor initial and overall correction. Conclusion: With proper patient selection, adequate intraoperative reduction with screw fixation involving the injured vertebra, and strict postoperative spinal bracing, the short-segment fixation is an efficient and safe method in the treatment of thoracolumbar burst fracture.

요추부 협착에서의 피질골 궤도 나사못 고정의 초기 실패 사례에 대한 고찰 (Early Failure of Cortical-Bone Screw Fixation in the Lumbar Spinal Stenosis)

  • 권지원;김진규;하중원;문성환;이환모;박융
    • 대한정형외과학회지
    • /
    • 제55권5호
    • /
    • pp.405-410
    • /
    • 2020
  • 목적: 퇴행성 요추부 척추 질환에 대한 수술적 치료로 척추 경 나사못(pedicle screw) 삽입술이 전통적으로 사용되어왔다. 이에 대한 대안으로 제시된 피질골 궤도 나사못(cortical-bone trajectory screw)은 덜 침습적인 후방 요추부 고정이 가능한 점과 몇몇의 생체 역학 연구에서 보고한 우수한 기계적 안정성을 장점으로 가지고 있다. 본 연구의 목적은 후방 감압술 후 후방 고정술 및 유합을 시행한 환자에 있어 피질골 궤도 나사못 고정술의 초기 실패에 관한 사례의 임상적 및 방사선적 결과를 알아보고자 함에 있다. 대상 및 방법: 요추의 퇴행성 척추 협착 및 척추 전방 전위에 대한 전통적인 척추 경 나사못 고정을 대안하여 피질골 궤도 나사못을 사용하여 2013년부터 2018년까지 수술적 치료를 시행한 311명의 환자를 대상으로 하였다. 수술 후 조기 고정 실패는 수술 후 6개월째, 외래 추시에서 시행한 컴퓨터 단층촬영(computed tomography) 및 방사선 사진상 나사못의 이완, 이탈 및 파손과 같은 고정 실패가 일어날 시로 정의하였다. 결과: 조기 고정 실패는 311예 중 46예(14.8%), 나사못 이완이 46예(14.8%), 이탈이 12예(3.9%), 파손이 4예(1.3%)에서 발생하였다. 해당 고정 실패가 일어난 부위 분석 시, L1이 7예(15.2%), L2가 3예(6.5%), L3가 4예(8.7%), L4가 4예(8.7%), L5가 4예(8.7%), 그리고 S1이 24예(52.2%)였다. 주로 말단 피질골 궤도 나사못 중에서도 S1 나사못에서 이완, 이탈 및 파손과 같은 고정 실패가 주로 발생하였다. 결론: 피질골 궤도 나사못 고정은 기존의 척추 경 나사못 고정과 비교했을 때 동등한 임상 결과 또는 적은 합병증을 나타낼 수 있는 하나의 대안이 될 수 있으나 골다공증이 있거나 특히 L5-S1 유합부위에서 전방지지구조가 되지 않는 조건일 때, 이완, 이탈, 파손 등의 조기 고정 실패가 나타나는 결과가 있었다.

Use of a Y-Shaped Plate for Intermaxillary Fixation

  • Kim, Tae Hoon;Yang, Il Hyung;Minn, Kyung Won;Jin, Ung Sik
    • 대한두개안면성형외과학회지
    • /
    • 제16권2호
    • /
    • pp.96-98
    • /
    • 2015
  • Maxillomandibular fractures usually require intermaxillary fixation as a means to immobilize and stabilize the fracture and to re-establish proper occlusion. Arch bars or intermaxillary fixation screws cannot be used for edentulous patients or for patients who have poor dental health. Here, we present a case of repeated intermaxillary fixation failure in a patient weak alveolar rigidity secondary to multiple dental implants. Because single-point fixation screws were not strong enough to maintain proper occlusion, we have used Y-shaped plates to provide more rigid anchoring points for the intermaxillary wires. We suggest that this method should be considered for patients in whom conventional fixation methods are inappropriate or have failed.

Xenograft Failure of Pulmonary Valved Conduit Cross-linked with Glutaraldehyde or Not Cross-linked in a Pig to Goat Implantation Model

  • Kim, Dong Jin;Kim, Yong Jin;Kim, Woong-Han;Kim, Soo-Hwan
    • Journal of Chest Surgery
    • /
    • 제45권5호
    • /
    • pp.287-294
    • /
    • 2012
  • Background: Biologic valved grafts are important in cardiac surgery, and although several types of graft are currently available, most commercial xenografts tend to cause early disfiguration due to intimal proliferation and calcification. We studied the graft failure patterns on non-fixed and glutaraldehyde-fixed pulmonary xenograft in vivo animal experiment. Materials and Methods: Pulmonary valved conduits were obtained from the right ventricular outflow tract of eleven miniature pigs. The grafts were subjected to 2 different preservation methods; with or without glutaraldehyde fixation: glutaraldehyde fixation (n=7) and non-glutaraldehyde fixation (n=4). The processed explanted pulmonary valved grafts of miniature pig were then transplanted into eleven goats. Calcium quantization was achieved in all of the explanted xenograft, hemodynamic, histopathologic and radiologic evaluations were performed in the graft which the transplantation period was over 300 days (n=7). Results: Grafts treated with glutaraldehyde fixation had more calcification and conduit obstruction in mid-term period. Calcium deposition also appeared much higher in the glutaraldehyde treated graft compared to the non-glutaraldehyde treated graft (p<0.05). Conclusion: The present study suggests that xenografts prepared using glutaraldehyde fixation alone appeared to have severe calcification compared to the findings of non-glutaraldehyde treated xenografts and to be managed with proper anticalcification treatment and novel preservation methods. This experiment gives the useful basic chemical, histologic data of xenograft failure model with calcification for further animal study.

Cut-Through versus Cut-Out: No Easy Way to Predict How Single Lag Screw Design Cephalomedullary Nails Used for Intertrochanteric Hip Fractures Will Fail?

  • Garrett W. Esper;Nina D. Fisher;Utkarsh Anil;Abhishek Ganta;Sanjit R. Konda;Kenneth A. Egol
    • Hip & pelvis
    • /
    • 제35권3호
    • /
    • pp.175-182
    • /
    • 2023
  • Purpose: This study aims to compare patients in whom fixation failure occurred via cut-out (CO) or cut-through (CT) in order to determine patient factors and radiographic parameters that may be predictive of each mechanism. Materials and Methods: This retrospective cohort study includes 18 patients with intertrochanteric (IT) hip fractures (AO/OTA classification 31A1.3) who underwent treatment using a single lag screw design intramedullary nail in whom fixation failure occurred within one year. All patients were reviewed for demographics and radiographic parameters including tip-to-apex distance (TAD), posteromedial calcar continuity, neck-shaft angle, lateral wall thickness, and others. Patients were grouped into cohorts based on the mechanism of failure, either lag screw CO or CT, and a comparison was performed. Results: No differences in demographics, injury details, fracture classifications, or radiographic parameters were observed between CO/CT cohorts. Of note, a similar rate of post-reduction TAD>25 mm (P=0.936) was observed between groups. A higher rate of DEXA (dual energy X-ray absorptiometry) confirmed osteoporosis (25.0% vs. 60.0%) was observed in the CT group, but without significance. Conclusion: The mechanism of CT failure during intramedullary nail fixation of an IT fracture did not show an association with clinical data including patient demographics, reduction accuracy, or radiographic parameters. As reported in previous biomechanical studies, the main predictive factor for patients in whom early failure might occur via the CT effect mechanism may be related to bone quality; however, conduct of larger studies will be required in order to determine whether there is a difference in bone quality.