• Title/Summary/Keyword: Failure Type

Search Result 2,299, Processing Time 0.034 seconds

Deviations of Implant Position between Pre- and Post-operation in Computer-guided Template-based Implant Placement (Computer-guided template를 이용한 임플란트 식립에서 술 전과 술 후 사이의 임플란트 위치에 따른 변위량 검사)

  • Kim, Won;Kim, Seung-Mi;Kim, Hyo-Jung;Song, Eun-Young;Lee, Si-Ho;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.175-184
    • /
    • 2011
  • With a development of implant restoration technique, there are increasing use of computer-guided system for edentulous patients. It was carried out simulated operation based on CT information about patient's bone quantity, quality and anatomical landmark. However, there are some difference between the programmed implant and post-operative implant about it's position. If the deviation was severe, it could happen a failure of 'passive fit' and not suited for path of implant restoration. The aim of this presentation is to evaluate about a degree of deviations between programmed implant and post-operative implant. Five patients treated by 'NobelGuide' system (Nobel Biocare AB, G$\ddot{o}$teborg, Sweden) in Department of Prosthodontics, Inha University were included in this study. The patients were performed CT radiograph taking and intra-oral impression taking at pre-operation. Based on CT images and study model, surgical stent was produced by NobelBiocareTM. To fabricated a pre-operative study model, after connected lab analog to surgical template, accomplished a pre-operative model using type 4 dental stone. At final impression, a post-operative study model was fabricated in the conventional procedures. Each study model was performed CT radiograph taking. Based on CT images, each implant was simulated in three dimensional position using $Procera^{(R)}$ software (Procera Software Clinical Design Premium, version 1.5; Nobel Biocare AB). In 3D simulated model, length and angulation between each implant of both pre- and post-operative implants were measured and recorded about linear and angular deviation between pre-and post-operative implants. A total of 24 implants were included in this study and 58 inter-implant sites between each implant were measured about linear and angular deviations. In the linear deviation a mean deviation of 0.41 mm (range 0~1.7 mm) was reported. In the angular deviation, a mean deviation was $1.99^{\circ}$ (range $0^{\circ}{\sim}6.7^{\circ}$). It appears that the both linear and angular mean deviation value were well acceptable to application of computer-guided implant system.

Investigational Studies on Reproductive Failures of Slaughtered Cows (도살빈우의 번식장애사례 조사연구)

  • 이용빈;임경순
    • Korean Journal of Animal Reproduction
    • /
    • v.6 no.1
    • /
    • pp.19-30
    • /
    • 1982
  • 1. The cows slaughtered at age of 3, 4, 6, 7, 8, and 9 years old were 1.5, 1.5, 15.0, 62.5 and 4.4% respectively. 2. The cows slaughtered at 351-450kg and more than 500kg were 60 and 28% respectively. 3. Best, very good, good and bad cows in nutritional condition were 1.6, 25.8, 62.9, and 9.7% respectively. Among the six cows which were bad nutrition, the two were with severe endometritis, the three were normal in genital function and one was on 70 days of pregnancy. 4. Holstein cows(55.2%) showed higher reproductive failure than the Korean cows(33.3%). 5. The slaughted ratio of the Korean cattle and Holstein cows was 36 and 64% respectively. 6. Pregnant cows were about 16% among the slaughtered one. 7. Reproductive failures were composed of 46% in uterus, 32% in ovaries, 8% in udder, 6% in oviduct, 4% in cervix of uterine, 2% in vagina and 2% inmummified fetus. 8. Forty six percentages of uterine diseases were as follows; horn, 13%, body of uterus, 32% and ovary diseases were 32%, that is, 12% of ovary atrophy, 8% of ovarycyst and 6% of lutealcyst. 9. The cows of reproductive failures were commonly infected with 1.6 kinds of diseases. 10. According to classification, six type of ovaries were as follows; normal, 58%, ovary-cyst, 11%, luteum cyst, 4%, coexistence of follicles and corpus luteum, 16%, weak function of ovaries, 10% and ovarian atrophy, 1%. 11. Major axis, minor axis and thickness of right ovary were larger than those of left one both in Korean cattle and Holstein cows. Holstein cow had generally larger size of ovary than these of the Korean cattle.. 12. The left and right oviducts showed no difference in length, but Holstein had longer oviduct than Korean cow. 13. There was no difference in the length of uterine horn between right and left in the Korean cows, but the right was longer than the left in Holstein cows. 14. Holstein had longer horn and body of uterine than the Korean cows. 15. The weight of right ovary was heavier than that of left in both breeds, but there was no differences in weight of left ovary between two breeds and right ovary of Holstein breed was heavier than that of the Korean cow. 16. The weight of right oviduct and uterine born was heavier than that of the left, and Holstein had heavier oviducts and uterine horns than the Korean cows. 17. Holstein had heavier uterine body and cervix of uterine than the Korean cows. 18. The length of reproductive systems of Korean cow is as follows; Major and minor diameter and thickness ofovary are 3.6${\pm}$0.7, 2.3${\pm}$0.4 and 1.6${\pm}$1.4 cm in left and 3.7${\pm}$0.6, 2.5${\pm}$0.5 and 1.8${\pm}$0.5 cm in right. Oviduct is 28.4${\pm}$3.1 cm in left and 27.8${\pm}$3.3 cm in right. Uterine horn is 27.4${\pm}$4.5 cm in left and 27.7${\pm}$4.9 cm in right. Uterine body and cervix are 3.4${\pm}$1.1 and 6.5${\pm}$1.7 cm. 19. The length of female reproductive systems ofHolstein cow is as follows; Major and minor diameter and thickness of ovary are 3.9${\pm}$1.3, 2.3${\pm}$0.5, and 1.5${\pm}$0.6 cm in left and 4.0${\pm}$0.8, 2.8${\pm}$0.6 and 1.8${\pm}$0.6 cm in right. Oviduct is 29.4${\pm}$4.2 cm in left and 29.3${\pm}$4.1 cm in right. Uterine horn is 30.2${\pm}$7.4 cm in left and 32.6${\pm}$8.4 cm in right. Uterine body and cervix are 4.5${\pm}$2.5 and 7.8${\pm}$2.9 cm. 20. The weight of reproductive systems of Korean cow is as follows; Ovary is 8.4${\pm}$4.1 g in left and 9.3${\pm}$3.6g in right. Oviduct is 1.5${\pm}$0.5 g in left and 1.6${\pm}$0.5 g in right. Uterine horn is 109${\pm}$27 g left and 118${\pm}$32 g in right. Uterine body and cervix are 30.4${\pm}$14.1 and 76.7${\pm}$38.4g. 21. The weight of reproductive systems of Holstein cow is as follows; Ovary is 8.2${\pm}$3.1 g in left and 12.5${\pm}$5.6 g in right. Oviduct is 1.7${\pm}$0.6 g in left and 1.9${\pm}$0.9 g in right. Uterine horn is 199${\pm}$14.2 g in left and 221${\pm}$111.2g in right. Uterine body and cervix are 58.2${\pm}$46.5 and 126.7${\pm}$103.3 g.

  • PDF

The Evolution of Cyber Singer Viewed from the Coevolution of Man and Machine (인간과 기계의 공진화적 관점에서 바라본 사이버가수의 진화과정)

  • Kim, Dae-Woo
    • Cartoon and Animation Studies
    • /
    • s.39
    • /
    • pp.261-295
    • /
    • 2015
  • Cyber singer appeared in the late 1990s has disappeared briefly appeared. although a few attempts in the 2000s, it did not show significant successes. cyber singer was born thanks to the technical development of the IT industry and the emergence of an idol training system in the music industry. It was developed by Vocaloid 'Seeyou' starting from 'Adam'. cyber singer that differenatiated typical digital characters in a cartoon or game may be subject to idolize to the music as a medium. They also feature forming a plurality of fandom. therefore, such attempts and repeated failures, this could be considered a fashion, but it flew content creation and ongoing attempts to take advantage of the new media, such as Vocaloid can see that there are expectations for a true Cyber-born singer. Early-Cyber singer is made only resemble human appearance, but 'Sciart' and 'Seeyou' has been evolving to becoming more like the human capabilities. in this paper, stylized cyber singer had disappeared in the past in the process of developing the technology to evolve into own artificial life does not end in failure cases, gradually led to a change in public perceptions of the image look looking machine was an attempt in that sense. With the direction of the evolution of the mechanical function to obtain a human, fun and human exchanges and mutual feelings. And it is equipped with an artificial life form that evolved with it only in appearance and function. in order to support this logic, I refer to the study of the coevolution of man and machine at every Bruce Mazlish. And, I have analyzed the evolution of cyber singer Bruce research from the perspective of the development process since the late 1990s, the planning of the eight singers who have appeared and design of the cyber character and important voices to be evaluated as a singer (vocal). The machine has been evolving coevolution with humans. cyber singer ambivalent development targets are recognized, but strive to become the new artificial creatures of horror idea of human desire and death continues. therefore, the new Cyber-organisms are likely to be the same style as 'Seeyou'. because, cartoon forms and whirring voice may not be in the form of a signifier is the real human desires, but this is because the contemporary public's desire to be desired and the technical development of this type can be created at the point where the cross-signifier.

Occlusive Complications after Lower Limb Arterial Bypass Surgery (하지동맥 재건술 후 폐쇄성 합병증에 대한 임상적 고찰)

  • Kim Jong Won;Chung Sung Woon
    • Journal of Chest Surgery
    • /
    • v.38 no.2 s.247
    • /
    • pp.152-156
    • /
    • 2005
  • Background: Occlusive complications after arterial revascularization are difficult to treat and have high recurrence rate. This study was performed to establish an effective treatment modality and to evaluate the factors affecting the occlusive complications by analysis of clinical data. Material and Method: During the period of 5 years. 33 patients (55 reoperations) were studied at the Department of Thoracic and Cardiovascular Surgery, Pusan National University Hospital following 173 arterial revascularization surgeries. The clinical characteristics, operating methods, the time intervals of reoperation, used graft, and the results of treatment were evaluated retrospectively. Result: All the patients were men except one and the mean age was 63.5 years old. The mean time internal from first operation to reoperation was 11.9 months. The cause of arterial occlusive diseases were 28 atherosclerosis and 5 Burger's diseases, Associated diseases were Hypertension $(57.6\%)$, Diabetes mellitus $(33.3\%)$, heart failure $(18.2\%)$, and so on. The mean rate of reoperation was 1.67 times and the most common type of first operation was femoro-popliteal bypass grafting $(57.6\%)$. The graft that used revascularization surgery were 25 cases of PTFE and 6 case were Dacron. There was no statistical difference between two groups. The kinds of reoperations were thrombectomy in 20 cases, angioplasty 18 cases, re-bypass surgery in 13 cases, and lumbar sympathectomy in 4 cases. The results of reoperation were 15 cases of functional recovery, 7 cases of limb salvage, 5 cases of above-knee amputation. 3 cases of below-knee amputation and 3 deaths. Conclusion: The main cause of occlusive complications are occlusion of inflow or outflow artery. Treatments were different according to the first operation methods and graft used. The most frequent time of reoperation was within one year after the first operation. We believe that graft surveillance especially during the first year is very important factor in observing the patient. We can look forward to improving limb salvage rate to perform additional treatment such as radiological interventions and lumbar sympathectomy.

Analysis of Building Characteristics and Temporal Changes of Fire Alarms (건물 특성과 시간적 변화가 소방시설관리시스템의 화재알람에 미치는 영향 분석 연구)

  • Lim, Gwanmuk;Ko, Seoltae;Kim, Yoosin;Park, Keon Chul
    • Journal of Internet Computing and Services
    • /
    • v.22 no.4
    • /
    • pp.83-98
    • /
    • 2021
  • The purpose of this study to find the factors influencing the fire alarms using IoT firefighting facility management system data of Seoul Fire & Disaster Headquarters, and to present academic implications for establishing an effective prevention system of fire situation. As the number of high and complex buildings increases and former bulidings are advanced, the fire detection facilities that can quickly respond to emergency situations are also increasing. However, if the accuracy of the fire situation is incorrectly detected and the accuracy is lowered, the inconvenience of the residents increases and the reliability decreases. Therefore, it is necessary to improve accuracy of the system through efficient inspection and the internal environment investigation of buildings. The purpose of this study is to find out that false detection may occur due to building characteristics such as usage or time, and to aim of emphasizing the need for efficient system inspection and controlling the internal environment. As a result, it is found that the size(total area) of the building had the greatest effect on the fire alarms, and the fire alarms increased as private buildings, R-type receivers, and a large number of failure or shutoff days. In addition, factors that influencing fire alarms were different depending on the main usage of the building. In terms of time, it was found to follow people's daily patterns during weekdays(9 am to 6 pm), and each peaked around 10 am and 2 pm. This study was claimed that it is necessary to investigate the building environment that caused the fire alarms, along with the system internal inspection. Also, it propose additional recording of building environment data in real-time for follow-up research and system enhancement.

A Study on the Effect of Applying Water Seepage Lowering Method Using Swelling Waterstop for Expansion Joint in the Concrete Dam (콘크리트 댐에서 수축이음부의 수팽창성 차수재를 이용한 침투저감 공법 적용효과 연구)

  • Han, Kiseung;Lee, Seungho;Kim, Sanghoon;Kim, Sejin;Pai, Sungjin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.10
    • /
    • pp.21-29
    • /
    • 2021
  • Most concrete gravity-type dams in and out of the country were constructed by column method to control cracks caused by concrete hydration heat generated during construction, resulting in a certain level of leakage after impoundment through various causes, such as contraction joints and construction joints. However, due to the characteristics of concrete structures that shrink and expand according to temperature, concrete dams have vertical joints and drains to allow penetration. PVC waterproof shows excellent effects in completion of the dam, which however increases the possibility of interfacial failure due to different thermal expansion. Other causes of penetration may include problems with quality control during installation, generation of cracks due to heat of hydration of concrete, waterproofing methods, etc. In the case of Bohyunsan Dam in Yeongcheon, North Gyeongsang Province, the amount of drainage in the gallery was checked and underwater, and it was confirmed that there are many penetrations from drainage holes connected to vertical joints, and that some of the PVC waterproofs are not fully operated. As a new method to prevent penetration through vertical joints, D.S.I.M. (Dam Sealing Innovation Method) developed by World E&C was applied to Bohyunsan Dam and checked the amount of drainage in the gallery. As a result of first testing three most leaking vertical joints, the drain in the gallery was reduced by 87% on the average and then applied to the remaining 13 locations, which showed a 83% reduction effect based on the total drain in the gallery. Summing up these results, it was found that D.S.I.M. preventing water leakage from the upstream face is a valid construction method to reduce the water see-through and penetration quantity seen in downstream faces of concrete dams. If D.S.I.M. is applied to other concrete dams at domestic and abroad, it is expected that it will be very effective to prevent water leakage through vertical joints that are visible from downstream faces.

Experiments on Flow Characteristics of Asphalt Seal Composite Waterproofing Method for Underground Concrete Structure Exterior Wall Waterproofing (지하 콘크리트 구조물 외벽 방수용 아스팔트 씰재 복합방수 공법의 흘러내림 특성에 관한 실험)

  • Ko, Sang-Ung;Kim, Kyoung-Hoon;Kim, Young-Sam;Shin, Hong-Chul;Kim, Jin-Man
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.4
    • /
    • pp.297-303
    • /
    • 2018
  • With the changing trend of the building construction to high rising and large scaling, the underground structure has been increased, and its usage also increased and variety. Hence, to protect the underground structure against underground water, various water proofing methods has been developed. Among the many water proofing methods, the combined water proofing method using both asphalt seal and sheet has been widely used to secure the sufficient performance and decrease the construction failure. However, during the summer period of extremely high temperature conditions, the asphalt sealing materials were separated and leaked into the structure. Therefore, the aim of the research is to provide the quality standard of asphalt sealing material based on the various temperature changes depending on seasons. According to the experimental results, the temperature of the sealing materials applied on the slab was increased up to $54^{\circ}C$ which was $3^{\circ}C$ higher than the structure temperature of $51^{\circ}C$. Based on the melting test for asphalt sealing materials applied on the outside wall of the structure, in the case of water-dispersing typed materials showed significant melting down due to its slow evaporation and low viscosity. Furthermore, from the accelerated test conducted indoor conditions, a solvent-type and water-dispersing typed materials showed significant melting down due to their low viscosity and melting point in ambient conditions. Based on these results, viscosity and melting point are found as the important factors on asphalt sealing materials' quality, and it is necessary to designate the quantitative level of the viscosity and melting point for quality control.

A Study on Setup for Preliminary Decision Criterion of Continuum Rock Mass Slope with Fair to Good Rating (양호한 연속체 암반사면의 예비 판정기준 설정 연구)

  • Kim, Hyung-Min;Lee, Su-gon;Lee, Byok-Kyu;Woo, Jae-Gyung
    • The Journal of Engineering Geology
    • /
    • v.29 no.2
    • /
    • pp.85-97
    • /
    • 2019
  • It can be observed that steep slopes ($65^{\circ}$ to $80^{\circ}$) consist of rock masses were kept stable for a long time. In rock-mass slopes with similar ground condition, steeper slopes than 1 : 0.5 ($63^{\circ}$) may be applied if the discontinuities of rock-mass slope are distributed in a direction favorable to the stability of the slope. In making a decision the angle of the slope, if the preliminary rock mass conditions applicable to steep slope are quantitatively setup, they may be used as guidance in design practice. In this study, the above rock mass was defined as a good continuum rock mass and the quantitative setup criterion range was proposed using RMR, SMR and GSI classifications for the purpose of providing engineering standard for good continuum rock mass conditions. The methods of study are as follows. The stable slope at steep slopes ($65^{\circ}$ to $80^{\circ}$) for each rock type was selected as the study area, and RMR, SMR and GSI were classified to reflect the face mapping results. The results were reviewed by applying the calculated shear strength to the stable analysis of the current state of rock mass slope using the Hoek-Brown failure criterion. It is intended to verify the validity of the preliminary criterion as a rock mass condition that remains stable on a steep slope. Based on the analysis and review by the above research method, it was analyzed that a good continuum rock mass slope can be set to Basic RMR ${\geq}50$ (45 in sedimentary rock), GSI and SMR ${\geq}45$. The safety factor of the LEM is between Fs = 14.08 and 67.50 (average 32.9), and the displacement of the FEM is 0.13 to 0.64 mm (average 0.27 mm). This can be seen as a result of quantitative representation and verification of the stability of a good continuum rock mass slope that has been maintained stable for a long period of time with steep slopes ($65^{\circ}$ to $80^{\circ}$). The setup guideline for a good continuum rock mass slope will be able to establish a more detailed setup standard when the data are accumulated, and it is also a further study project. If stable even on steep slopes of 1 : 0.1 to 0.3, the upper limit of steep slopes is 1 : 0.3 with reference to the overseas design standards and report, thus giving the benefit of ensuring economic and eco-friendlyness. Also, the development of excavation technology and plantation technology and various eco-friendly slope design techniques will help overcome psychological anxiety and rapid weathering and relaxation due to steep slope construction.

Study on Improvement of Mechanical Property, Oxidation and Erosion Resistance of SiC Matrix Ceramic Composites Reinforced by Hybrid Fabric Composed of SiC and Carbon Fiber (탄화규소섬유와 탄소섬유 하이브리드 직물을 강화재로 한 SiC 매트릭스 세라믹복합재의 기계적물성, 산화 및 삭마 저항성 개선 연구)

  • Yoon, Byungil;Kim, Myeongju;Kim, Jaesung;Kwon, Hyangjoo;Youn, Sungtae;Kim, Jungil
    • Composites Research
    • /
    • v.32 no.3
    • /
    • pp.148-157
    • /
    • 2019
  • In this study, $C_f/SiC$, $SiC_f/SiC$ and $C_f-SiC_f/SiC$ ceramic composites reinforcing carbon fiber, SiC fiber and hybrid fiber were fabricated by hybrid TGCVI and PIP process. After the thermal shock cycle, 3-point bending and Oxy-Acetylene torch test, their mechanical behavior, oxidation and erosion resistance were evaluated. The $C_f/SiC$ composite showed a decrease in mechanical property along with increasing temperature, a pseudo-ductile fracture mode and a large quantity of erosion. The $SiC_f/SiC$ composite exhibited stronger mechanical property and lower erosion rate compared to the $C_f/SiC$, but brittle fracture mode. On the other hand, hybrid type of $C_f-SiC_f/SiC$ composite gave the best mechanical property, more ductile failure mode than the $SiC_f/SiC$, and lower erosion rate than the $C_f/SiC$. During the Oxy-Acetylene torch test, the $SiO_2$ formed by reaction of the SiC matrix with oxygen prevented further oxidation or erosion of the fibers for $C_f-SiC_f/SiC$ and $SiC_f/SiC$ composites particularly. In conclusion, if a hybrid composite with low porosity is prepared, this material is expected to have high applicability as a high temperature thermo-structural composite under high temperature oxidation atmosphere by improving low mechanical property due to the oxidation of $C_f/SiC$ and brittle fracture mode of $SiC_f/SiC$ composite.

A Study on the Development of Assessment Index for Catastrophic Incident Warning Sign at Refinery and Pertrochemical Plants (정유 및 석유화학플랜트 중대사고 전조신호 평가지표 개발에 관한 연구)

  • Yun, Yong Jin;Park, Dal Jae
    • Korean Chemical Engineering Research
    • /
    • v.57 no.5
    • /
    • pp.637-651
    • /
    • 2019
  • In the event of a major accident such as an explosion in a refinery or a petrochemical plant, it has caused a serious loss of life and property and has had a great impact on the insurance market. In the case of catastrophic incidents occurring in process industries such as refinery and petrochemical plants, only the proximate causes of loss have been drawn and studied from inspectors or claims adjustors responsible for claims of property insurers, incident cause investigators, and national forensic service workers. However, it has not been done well for conducting root cause analysis (RCA) and identifying the factors that contributed to the failure and establishing preventive measures before leading to chemical plant's catastrophic incidents. In this study, the criteria of warning signs on CCPS catastrophic incident waning sign self-assessment tool which was derived through the RCA method and the contribution factor analysis method using the swiss cheese model principle has been reviewed first. Secondly, in order to determine the major incident warning signs in an actual chemical plant, 614 recommendations which have been issued during last the 17 years by loss control engineers of global reinsurers were analyzed. Finally, in order to facilitate the assessment index for catastrophic incident warning signs, the criteria for the catastrophic incident warning sign index at chemical plants were grouped by type and classified into upper category and lower category. Then, a catastrophic incident warning sign index for a chemical plant was developed using the weighted values of each category derived by applying the analytic hierarchy process (pairwise comparison method) through a questionnaire answered by relevant experts of the chemical plant. It is expected that the final 'assessment index for catastrophic incident warning signs' can be utilized by the refinery and petrochemical plant's internal as well as external auditors to assess vulnerability levels related to incident warning signs, and identify the elements of incident warning signs that need to be tracked and managed to prevent the occurrence of serious incidents in the future.