• Title/Summary/Keyword: Fail Safety

Search Result 197, Processing Time 0.028 seconds

An Analysis on Incident Cases of Dynamic Positioning Vessels (Dynamic Positioning 선박들의 사고사례 분석)

  • Chae, Chong-Ju;Jung, Yun-Chul
    • Journal of Navigation and Port Research
    • /
    • v.39 no.3
    • /
    • pp.149-156
    • /
    • 2015
  • The Dynamic Positioning System consists of 7 elements which are namely Power system, Human machine interface, DP Computer, Position Reference System(PRS), Sensors, Thruster system and DP Operator. Incidents like loss of position(LOP) on DP vessel usually occur due to errors in these 7 elements. The purpose of this study is to find out safety operation method of DP vessel through qualitative and quantitative analyze of DP LOP incidents which are submitted to IMCA every year. The 612 DP LOP incidents submitted from 2001 to 2010 were analyzed to find out the main cause of the incidents and its rate among other causes. Consequently, the highest rate of incidents involving DP elements are PRS errors. DP computer, Power system, Human error and thruster system came next. The PRS has been analyzed and a flowchart was drawn through expert brainstorming. Also, the conditional probability has been analyzed through Bayesian Networks based on this flowchart. Consequentially, the main causes of drive off incidents were DGPS, microwave radar and HPR. Also, this study identified the main causes of DGPS errors through Bayesian Networks. These causes are signal blocked, electric components failure, relative mode error, signal weak or fail.

Comparison of Effects of Mask Style and Donning Training on Fit Factors of Particulate Filtering Facepiece Respirators (안면부 여과식 방진 마스크의 형태 및 착용 방법 교육이 밀착계수에 미치는 영향 비교)

  • Eoh, Won Souk;Choi, Youngbo;Shin, Changsub
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.35-41
    • /
    • 2016
  • Particulate filtering facepiece respirators (PFFR) is one of the most widely used items of personal protective equipments, and a tight fit of the respirators on the wearers is critical for the protection effectiveness. In order to effectively protect the workers through the respirators, it is important to find and evaluate the ways that can be readily applicable at the workplace to improve the fit of the respirators. This study was designed to evaluate effects of mask style (cup or foldable type) and donning training on fit factors (FF) of the respirators, since these are available at various workplace, especially at small business workplace. A total of 40 study subjects, comprised of 30~50s aged male and female workers in metalworking industries, were enrolled in this study. The FF were quantitatively measured before and after training related to the proper donning and use of cup or foldable-type respirators. The pass/fail criterion of FF was set at 100. After the donning training for the cup-type mask, subjects who passed the fit test were increased from 10 to 33. Moreover, the geometric mean (GM) of FF was increased by 340% in subjects who failed the test. In addition, the training effects for the cup-type mask were significant in female and 50s aged subjects. On the other hand, although the GM of FF for the foldable-type mask was also increased after the donning training, the GM of FF for the foldable-type mask and it's increase rate were smaller as compared to the cup-type mask. Furthermore, the differences of the increase rates of the GM of FF in sex and aged of the subjects were not significantly for the foldable-type mask. The multi-distribution of leak points for the foldable-type mask may be one of causes for the less effect of training on the fit of the foldable-type mask. These results imply that the raining on the donning and use of PFFR can enhance the protection effectiveness of cup or foldable-type mask, and that the training effects for the foldable-type mask is less significant than that for the cup-type mask. Therefore, It is recommended that the donning training and fit tests should be conducted before the use of the PFFR, and that efficient tranining programs for the foldable-type mask are required.

Comparison of Recognition and Fit Factors according to Education Actual Condition and Employment Type of Small and Medium Enterprises (중소규모 사업장의 교육 환경과 고용형태에 따른 호흡보호구 인식도 및 밀착계수 비교)

  • Eoh, Won Souk;Choi, Youngbo;Shin, Chang Sub
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.6
    • /
    • pp.28-36
    • /
    • 2018
  • There was a difference in recognition of respirators according to the educational performance environment. they were showed higher recognition of respirators of group by internal and external mix trainer, less than 6 months, over 1hour, more than 5 times, variety of education. To identify the relationship between types of job classification(typical and atypical)and the levels of recognition of respirators, a total of 153 workers in a business workplace. mainly, typical workers showed higher recognition of respirators than atypical workers. Training of correct wearing showed high demands both typical and atypical workers. Descriptive statistics(SAS ver 9.2)was performed. the results of recognition of respirators were analyzed the mean and standard deviation by t-test, and anova, fit factor is used geometric means(geometric standard deviation), paired t-test, Wilcoxon analysis(P=0.05). Particulate filtering facepiece respirators (PFFR) is one of the most widely used items of personal protective equipments, and a tight fit of the respirators on the wearers is critical for the protection effectiveness. In order to effectively protect the workers through the respirators, it is important to find and evaluate the ways that can be readily applicable at the workplace to improve the fit of the respirators. This study was designed to evaluate effects of mask style (cup or foldable type) and donning training on fit factors (FF) of the respirators, since these are available at various workplace, especially at small business workplace. A total of 40 study subjects, comprised of employment type workers in metalworking industries, were enrolled in this study. The FF were quantitatively measured before and after training related to the proper donning and use of cup or foldable-type respirators. The pass/fail criterion of FF was set at 100. After the donning training for the cup-type mask, fit test were increased by 769%. but foldable-type mask was also increased after the donning training, the GM of FF for the foldable-type mask and it's increase rate were smaller as compared to the cup-type mask. Furthermore, the differences of the increase rates of the GM of FF in employment type of the subjects were not significantly for the foldable-type mask. These results imply that the raining on the donning and use of PFFR can enhance the protection effectiveness of cup or foldable-type mask, and that the training effects for the foldable-type mask is less significant than that for the cup-type mask. Therefore, it is recommended that the donning training and fit tests should be conducted before the use of the PFFR, and listening to workers opinion regularly.

Usability test of pulling cable exercise machine in the spinal cord injury disabled: Focusing on deriving improvement (척수 손상 장애인 대상 장애인용 풀링 케이블 운동기구의 사용성 평가: 개선점 도출을 중심으로)

  • Sung Shin Kim;Myo Jung Choi;Hyosun Kweon;Kwang Ok An;Young-Hyeon Bae
    • Journal of Korean Physical Therapy Science
    • /
    • v.31 no.1
    • /
    • pp.16-32
    • /
    • 2024
  • Background: Exercise equipments and assistive devices for the disabled are being developed, but improvements for usability are still needed. The purpose of this study was to improve and utilize the developed exercise equipment and assistance devices by conducting usability test for people with spinal cord injury. Design: Cross-sectional Study. Methods: Scenarios and usability indicators were derived by conducting a preliminary usability test, 5 non-disabled men and women aged 19 or older. In the scenario, a total of 9 tasks were sequentially performed, including 2 tasks of entry and exit, 5 tasks of assistance devices and weight stack adjustment, and 2 tasks of pre exercise and exercise. The usability indicators were task success (success or fail), execution time (sec), safety, and convenience. For safety, 7 questions (Likert scale, 1~5 point) related to safety, stability and hazard were derived, and for convenience, the system usability scale (SUS score) was used (range: 0~100, 50 percentile rank is 68 point). Results: As a result of the usability test of people with spinal cord injury, there was a large variation among subjects in the task of adjusting the position of the pulley and support in the execution time (11.64~25.44 seconds), and one person failed to adjust the pulley. The safety level showed a lower score (score = 3 points) than other items in the item of entrapment or skin pressure, and in the case of SUS, the average score was 64.5 points, which was close to the acceptable level. Conclusion: Through the usability test, it was confirmed that exercise equipment for the disabled needs improvement in operability, pinching, and pressure, and that it is necessary to develop an assistive device that provides unrestrained posture information (biofeedback) to maintain correct posture during exercise.

Comparison of Fit Factor for Healthcare Workers Before and After Training with the N95 Mask (의료용 N95 마스크 착용방법에 대한 교육 전·후 밀착계수 비교)

  • Kim, Hyunwook;Baek, Jung Eun;Seo, Hye Kyung;Lee, Jong-Eun;Myong, Jun-Pyo;Lee, Seung-Joo;Lee, Jin-Ho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.4
    • /
    • pp.528-535
    • /
    • 2014
  • Objectives: This study compares the differences of fit factors before and after training on the N95 mask. The results will be utilized to suggest the need of providing effective training on respirator use. Methods: A total of 49 study subjects were tested, comprised of nurses from a general hospital and undergraduate nursing students from a medical school. Anthropometric measurements of face length and face width were compared with the NIOSH(National Institute for Occupational Safety and Health) panel. Fit factors(FF) were measured with TSI Portacount Pro+8038 before and after on-site training regarding the proper use of respirators. The FF pass/fail criterion was set at 100. Results: Two subjects(4.1 %) passed the fit test before training on use of the N95. However, 36(73.5%) of the 49 passed the test after training. Overall the FF(GM(GSD)) was 13.4(3.2) before training, but improved to 106.6(2.1) after training, which was statistically significant. These findings suggest the efficacy of educational intervention, and the performance of the direct on-site training proved to be better than that of the traditional educational methods. Conclusions: This study showed the effect of on-site training of the N95 respirator among health care workers(HCW). Therefore, providing effective training on the use of N95 for HCWs before their work assignments will greatly reduce exposure to harmful agents. It is recommended that fit testing be mandated to check for adequate protection being provided by the given respirators.

The Effects of Interrelationship after Wearing between Respirators and Glasses Simultaneously (안면부 여과식 방진 마스크와 안경 동시 착용 시 상호 영향)

  • Eoh, Won Souk;Shin, Chang Sub
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.47-53
    • /
    • 2018
  • This study compares the interrelation of fit factor(FF) and visual acuity test by the order of wearing preference between Particulate filtering face piece respirators(PFFR) and glasses for 54 participants. Glasses fitting factors is Optical Center Height(OH), Vertex Distance(VD) and Pantoscopic Angle(PA) or Visual acuity. We measured those factors and expressed by the ratio of standard point and change point. Quantitative fit factor was measured by Portacount Pro+ 8038 and compared the result of preference of wearing order between respirators and glasses. Also, we selected to 6 exercises among 8 exercises OSHA QNFT (Quantitative Fit testing) protocol to measure the fit factors. The pass/ fail criterion of FF was set at 100. Visual acuity test chart is developed by Chunsuk Han was used, Descriptive statistics was performed. Descriptive statistics(SAS ver 9.2), it is used geometric means, Wilcoxon analysis, peason correlation(P=0.05) Fit factor was increased when the respirator was worn before wearing the glasses(p=0.000) and decreased for visual acuity(p=0.000) The negative correlation was showed between OH and Overall fit factor(r=-0.409, p=0.002). Among 54 participants, 11 participants(20.3%) were worn respirator before wearing glasses and 1 participant(1.9%) was worn glasses before wearing respirator. The overall fit test showed the higher level was investigated for the group of participants wearing respirator before wearing glasses in 6 exercises. Also, overall fit factor were increased when participants wore glasses prior to respirator(16.6) to respirator prior to glasses(36.6). Visual acuity were increased when participants wore respirator prior to glasses(93.8) to glasses prior to respirator(106.0). Finally, comparison result of overall fit factor and visual acuity were glasses first choice from mask first choice. The results showed that higher overall fit factor was investigate when the participants wore the respirator prior to glassess at all. The results implied that it is important to maintain the overall fit factor and visual acuity according to the consideration of OH for glasses fitting when worker wore respirator and glasses at the same time.

A Study on the Feasibility of Installing Solar Auxiliary Power for Small Fishing Boats (태양광 보조전원을 설치한 소형선박의 타당성 연구)

  • Yoon, Kyoungkuk;Jeon, Hyeonmin;Hwang, Junyoung;Kim, Jongsu
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.6
    • /
    • pp.883-889
    • /
    • 2021
  • The South Korean fishing industry is experiencing a rapid growth owing to an increase in its leisure-fishing population. Consequently, fishing boats weighing 9-10 [ton] have also been increasing. Current fishing boats operate their essential equipment by switching their engines with batteries to reduce the cost of gas and engine noise. However, stranding incidents have been increasingly recorded annually, in which boats fail to start owing to discharged batteries, and these incidents can lead to serious casualties. This study proposes the installation of a solar auxiliary power system to safeguard fishing boats, particularly those weighing between 9-10 [ton]. The feasibility of securing space for the solar auxiliary power of boats under consideration was verified. To examine the application of solar power, this study calculates the load necessary to operate it for fishing and models such a system using an electricity analysis program The modeled system, which applies the monthly horizontal solar insolation, validated the adoption of a solar auxiliary power in fishing boats.

A Study on the Parameters Influencing the Failed Soil-Slope in Okcheon Metamorphic Zone (옥천변성대 절개지 사면의 토층붕괴 영향인자에 관한 연구)

  • Lee, Kyoung-Mi;Kim, Byung-Chan;Seo, Yong-Seok
    • The Journal of Engineering Geology
    • /
    • v.19 no.4
    • /
    • pp.501-508
    • /
    • 2009
  • This study aims to clarify the characteristics of the physical and mechanical properties of soil-slope failure of Okcheon metamorphic zone. Soil samples were collected from 35 collapsed and uncollapsed artificial slopes along national roads. A series of laboratory experiments was carried out to examine physical and mechanical properties of soils and rocks. The results show that failure slopes have weakness of failure at 0.75 of AMI or higher, 32% of liquid limit or higher, and 31% of saturated moisture content or higher. The plastic index of failure slopes is correlated to wet density and saturated density. It turned out that failure could easily happen according to a high plastic index even if the void ratio was low. The greater the contents of bigger-sized soil, i.e. contents of sands and gravels rather than of clays, is the greater the chance to fail at the slope.

Development and Validation of Exposure Models for Construction Industry: Tier 2 Model (건설업 유해화학물질 노출 모델의 개발 및 검증: Tier-2 노출 모델)

  • Kim, Seung Won;Jang, Jiyoung;Kim, Gab Bae
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.2
    • /
    • pp.219-228
    • /
    • 2014
  • Objectives: The major objective of this study was to develop a tier 2 exposure model combining tier 1 exposure model estimates and worker monitoring data and suggesting narrower exposure ranges than tier 1 results. Methods: Bayesian statistics were used to develop a tier 2 exposure model as was done for the European Union (EU) tier 2 exposure models, for example Advanced REACH Tools (ART) and Stoffenmanager. Bayesian statistics required a prior and data to calculate the posterior results. In this model, tier 1 estimated serving as a prior and worker exposure monitoring data at the worksite of interest were entered as data. The calculation of Bayesian statistics requires integration over a range, which were performed using a Riemann sum algorithm. From the calculated exposure estimates, 95% range was extracted. These algorithm have been realized on Excel spreadsheet for convenience and easy access. Some fail-proof features such as locking the spreadsheet were added in order to prevent errors or miscalculations derived from careless usage of the file. Results: The tier 2 exposure model was successfully built on a separate Excel spreadsheet in the same file containing tier 1 exposure model. To utilize the model, exposure range needs to be estimated from tier 1 model and worker monitoring data, at least one input are required. Conclusions: The developed tier 2 exposure model can help industrial hygienists obtain a narrow range of worker exposure level to a chemical by reflecting a certain set of job characteristics.

Study on Design of Rail Level Crossing System for Preventing from Non-Alarming Status Caused by Track Shunting Sensibility Errors (레일 단락감도 불량으로 발생하는 무경보 예방을 위한 건널목보안장치 설계)

  • Jang, Dong-Wan;Jeon, Tae-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.160-166
    • /
    • 2010
  • Railroad level crossing systems are used to prevent train from collisions by informing pedestrians and vehicles of approaching trains on the level crossing. The current detection systems mostly use track-based electrical circuits to detect approaching trains. The making and breaking of the circuit when the train wheel passes along the track sends a signal to barriers that restrict access to the track. Unfortunately, this track-based signal system is vulnerable to malfunctions in certain situations. If the rail becomes rusted due to moisture, weather conditions, or infrequent use, the electrical circuit detection system could fail. Such a failure could lead to a train-vehicle or train-pedestrian collision. This paper suggests a replacement of the electrical circuit-based system with an infrared detection system. The research shows that an infrared detection system improves safety by reducing the frequency of detection failure of the alarming circuit to system.