• Title/Summary/Keyword: Facility safety response

Search Result 81, Processing Time 0.023 seconds

Indicator of Facility Performance Evaluation (FPE) for Educational Facilities of BTL Projects

  • Lee, Kwan-Jong;Lee, Chun-Kyong;Park, Tae-Keun
    • Architectural research
    • /
    • v.14 no.1
    • /
    • pp.35-44
    • /
    • 2012
  • Build-Transfer-Lease (BTL) was introduced to the domestic construction market in 2005. Now, seven years later, the BTL model is most active for educational facilities. In 2011, 93 educational facility projects entered the maintenance stage. Considering the characteristics of today's BTL projects for educational facilities, the main issues are the initial performance and maintenance of educational facilities and the service-providing status for the 20-year operational management period, in relation to providing safety and convenience to students, the facility users. Seeking a solution, local education offices and departments in charge of BTL under the Ministry of Education, Science, and Technology have been exploring various methods of evaluating operational maintenance performance from various perspectives. For educational facility BTL projects, however, the appropriateness of initial operation performance evaluation, rather than considering the 20-year operational management period, is controversial in regards to sustainability. On this account, performance evaluation items in four areas-operational maintenance evaluation, facility performance status evaluation, maintenance subject evaluation, and sustainable change response evaluation-should be extracted. An indicator of facility performance evaluation is presented in this study through an AHP survey targeting experts, as part of establishing an operation performance evaluation system for educational facility BTL projects.

Research on Railway Safety Common Data Model and DDS Topic for Real-time Railway Safety Data Transmission

  • Park, Yunjung;Kim, Sang Ahm
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.5
    • /
    • pp.57-64
    • /
    • 2016
  • In this paper, we propose the design of railway safety common data model to provide common transformation method for collecting data from railway facility fields to Real-time railway safety monitoring and control system. This common data model is divided into five abstract sub-models according to the characteristics of data such as 'StateInfoMessage', 'ControlMessage', 'RequestMessage', 'ResponseMessage' and 'ExtendedXXXMessage'. This kind of model structure allows diverse heterogeneous data acquisitions and its common conversion method to DDS (Data Distribution Service) format to share data to the sub-systems of Real-time railway safety monitoring and control system. This paper contains the design of common data model and its DDS Topic expression for DDS communication, and presents two kinds of data transformation case studied for verification of the model design.

Development of a Supporting Program for the Emergency Preparedness Plan (사고대비물질 취급자의 비상대응계획 작성 프로그램 연구)

  • Kim, Sung-Bum;Noh, Hye-Ran;Seok, Gwang-Seol;Park, Jae-Deuk
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.5
    • /
    • pp.54-58
    • /
    • 2011
  • Emergency preparedness plan(EPP) is the systematic management of activities that involve a material degree of risk of loss or other damage to the surroundings(people, property and environment), and the boundary of accident recovery plan(ARP). The main purpose of the program is to provide a safety management system to each facility in order to enable to prevent accident and to control accident immediately. The EPP includes not only typical safety-related documentations such as material safety data sheet(MSDS), standard operation procedure(SOP), emergency response plan(ERP). EPP is established basis of the preliminary safety analysis involving risk identification, assessment and prevention plans. The program is also helpful for government or related agencies to control a number of accidents in small-scale companies in the whole country.

Study on the Facility Planning for Relief Logistics Relieving Damage from Natural Disaster (자연 재해로 인한 피해 경감을 위한 구호 물류 거점 계획에 대한 연구)

  • Han, Sumin;Jeong, Hanil;Park, Jinwoo
    • The Journal of Society for e-Business Studies
    • /
    • v.23 no.3
    • /
    • pp.51-64
    • /
    • 2018
  • Recently, the magnitude and frequency of the natural disaster have been increased, the damage has become severer. The importance of disaster response system to relieve the damage has arised continuously. This study has tried to develop the algorithm to solve the facility location and size problem in emergency logistics. A facility in the emergency logistics has various roles in victim care, casualty treatment, relief resource management and relief vehicle assistance. Moreover, the location of facility in emergency logistics has to consider the safety and reliability. To gather these information, information management system with IoT sensors are suggested. The location problem in this study also covers various features to response various demands in disaster. To solve this problem, this study suggested MIP based algorithm. Scenario based simulation experiments are conducted to verify the performance suggested algorithm.

Multi-Objective Optimization Study of Blast Wall Installation for Mitigation of Damage to Hydrogen Handling Facility (수소 취급시설 피해 저감을 위한 방호벽 설치 다목적 최적화 연구)

  • Se Hyeon Oh;Seung Hyo An;Eun Hee Kim;Byung Chol Ma
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.6
    • /
    • pp.9-15
    • /
    • 2023
  • Hydrogen is gaining attention as a sustainable and renewable energy source, potentially replacing fossil fuels. Its high diffusivity, wide flammable range, and low ignition energy make it prone to ignition even with minimal friction, potentially leading to fire and explosion risks. Workplaces manage ignition risks by classifying areas with explosive atmospheres. However, the effective installation of a blast wall can significantly limit the spread of hydrogen, thereby enhancing workplace safety. To optimize the wall installation of this barrier, we employed the response surface methodology (RSM), considering variables such as wall distance, height, and width. We performed 17 simulations using the Box-Behnken design, conducted using FLACS software. This process yielded two objective functions: explosion likelihood near the barrier and explosion overpressure affecting the blast wall. We successfully achieved the optimal solution using multi-objective optimization for these two functions. We validated the optimal solution through verification simulations to ensure reliability, maintaining a margin of error of 5%. We anticipated that this method would efficiently determine the most effective installation of a blast wall while enhancing workplace safety.

A Study on the Improvement of Methodologies for Establishing a Vulnerability Classification of Chemical Terrorism in Public Facilities (다중이용시설 화학테러 취약등급설정 방법론 개선에 대한 연구)

  • Joo, Sun Ho;Kim, Si-Kuk;Hong, Sungchul
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.89-102
    • /
    • 2020
  • Chemical terrorism using toxic and flammable gases, which could be fatal to the health of the human body, poses a serious threat to the security of most advanced countries, as well as those that are suffering from local disputes, due to the asymmetric information that exists between terrorist actors and victims. The countermeasures against chemical terrorism can be roughly divided into three stages: prevention, response, and probation. The critical factors for each professional response agency, and the personnel that determine the degree and range of chemical terrorism damage, are performing missions successfully in the process of the prevention and the response stage against chemical terrorism. To do this, conducting objective and systematical assessments on facilities that could potentially be the subject of chemical terrorism is more important than anything. In this study, we compared the existing domestic and foreign vulnerable classification systems for chemical terrorism, reviewed the current direction of improvement in domestic classification systems, and suggested more scientific and systematic methodologies through the vulnerability assessment on an actual public facility sample.

A Study on the Effectiveness of Virtual and Real Experience Type Safety Education at Construction Sites (건설현장에 접목한 가상체험·실물체험 안전교육의 효과성 연구)

  • Cho Choonhwan
    • Journal of the Korea Institute of Construction Safety
    • /
    • v.6 no.1
    • /
    • pp.1-6
    • /
    • 2024
  • Existing safety education delivered to construction workers has limitations in concentration and immersion, so delivery power and interest are low. In order to improve the unstable behavior of construction workers and prevent safety accidents through education, a paradigm shift to hands-on education is necessary. Experiential safety education aims to contribute to the prevention of safety accidents and induce safe behavior by construction workers to recognize risks faster, select safe working methods suitable for the working environment, and improve emergency response and proactive response. Experiential education facilities have a follow-up learning effect in case of danger. The experience facility, which consists of the same working environment as the actual construction site, is designed to experience falls, equipment contraction, fire, and electric shock. In order to achieve the results of safety education that has invested a lot of time, construction workers must have motivation to participate, and "experiential safety education" through playful, deviant, and aesthetic experiences reduces serious accidents.

Analysis for Internal Audit and External Audit of the Sanitation/Safety Management Performance for the School Foodservice in Gyeongbuk Area (경북지역 학교 급식소의 위생관리에 대한 자체평가와 외부평가의 분석)

  • Lee Hye-Sang
    • Korean Journal of Community Nutrition
    • /
    • v.11 no.3
    • /
    • pp.374-382
    • /
    • 2006
  • The purpose of the study was to investigate the effects of the characteristics of dietitians, the characteristics of school food services, equipment ratio of HACCP facility/equipment and perception of barriers to HACCP implementation on external and internal audit of food safety/sanitation management performance in school food service. An e-mail survey was conducted with 144 dietitians in Gyeongbuk Province. A response rate was 57.6% (N = 83) and data was analyzed using SPSS windows (ver. 12.0). Dietitian perceived facilities/equipment-related and stakeholder-related as the big barriers in implementing a HACCP system. Total scores of sanitation/safety management performance for external and internal audit were similar at 92 and 91 out of 100, respectively. 'Facilities/equipment' and 'HACCP system' categories in both external and internal audit were rated the lowest. As dietitian perceived facilities/equipment-related (p < 0.001) and stakeholder-related (p < 0.05) barriers to HACCP implementation were greater, the scores of the external and internal audits were significantly lower. As dietitian perceived barriers for all categories were greater, the scores of internal audits were significantly lower (p <0.05). As a result of multiple regression analyses, the scores of the external audit was positively associated with career as a school food service dietitian, but was negatively associated with barriers related to facility/equipment, while the scores of the internal audit was negatively associated with barriers related to facility/equipment and employees. This study suggests that supporting programs on securing the facilities/equipment and employee training are needed for successful HACCP implementation in school food service.

Proposal of Checklist for the Management of Defects in Barracks Facilities (병영시설 하자관리를 위한 체크리스트 제안)

  • Kim, Jeong-Seop;Bang, Hong-Soon;Kim, Ok-Kyue
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.41-42
    • /
    • 2022
  • The management of defects in barracks facilities is carried out in such a way that defects found by the facility's manager are listed and requested to be repaired by the contractor. However, the standards and methods for the inspection of defects in the management of these defects are not specified in detail, so it is difficult to check the defects in detail. In response, the study first analyzed the current status of the number of defects that occurred in 2021 at official residences and barracks of certain units. As a result of the analysis, the number of defects that were not taken care of and that were not taken until the previous month was more than 10 cases on average per month. In order to reduce the number of such defects, major improvements in the field, timing, and safety inspection were found after the inspection of the military's facilities and safety, and the analysis of the manual of maintenance management. In addition, items for improvement of the checklist were derived through an analysis of the repair of defects caused by the unit's official residence and a total of 10 barracks facilities. Based on this, a checklist was proposed to manage defects in barracks facilities through interviews with military facility managers.

  • PDF

Development of U-Building Fire Safety Management System (U-건물 화재안전관리 시스템 개발)

  • Kim, Jong-Hoon
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.74-80
    • /
    • 2016
  • Ubiquitous computer technology (U technology) is continually, and the trend is moving towards the miniaturization of devices, cost reduction, performance enhancement, and intelligence. It is important to improve fire safety system by the application of advanced IT technologies. In this study, a vulnerable point in fire safety was selected for improvement by U technology. The structure of the whole system and a unit system was were designed. This system is divided into 5 parts: the U-fire protection facility management system, the U-fire safety information system, the U-fire safety education system, the U-fire response system, and the U-wide area fire safety management system. The prototype system was constructed in a real building to confirm the applicability of the system.