• Title/Summary/Keyword: Facility interface

Search Result 168, Processing Time 0.025 seconds

Development of Long-Term Storage Technology for Chinese Cabbage - Physiological Characteristics of Postharvest Freshness in a Cooler with a Monitoring and Control Interface

  • Lim, Ki Taek;Kim, Jangho;Chung, Jong Hoon
    • Journal of Biosystems Engineering
    • /
    • v.39 no.3
    • /
    • pp.194-204
    • /
    • 2014
  • Purpose: The aim of this study was to develop long-term storage technology for Chinese cabbage in order to extend the period of availability of freshly harvested products. The scope of the paper deals with the use of a cooler with a remote monitoring and control interface in conjunction with use of packaging film. Methods: A cooler with a real time monitoring system was designed as a low-temperature storage facility to control temperature and relative humidity (RH). The effects of storage in high-density polyethylene (HDPE) plastic boxes, 3% chitosan dipping solution, polypropylene film (PEF) with perforations, and mesh packaging bags on physiological responses were investigated. The optimal storage temperature and humidity for 120 days were below $0.5^{\circ}C$ and 90%, respectively. Physiological and biochemical features of cabbage quality were also analyzed: weight loss, texture, and sugar salinity, chlorophyll, reducing sugar, and vitamin C contents. Results: The cooler with a remote monitoring and control interface could be operated by an HMI program. A $0.5^{\circ}C$ temperature and 90% humidity could be remotely controlled within the cooler for 120 days. Postharvest freshness of Chinese cabbages could be maintained up to 120 days depending on the packaging method and operation of the remote monitoring system. In particular, wrapping the cabbages in PEF with perforations resulted in a less than a 5% deterioration in quality. This study provides evidence for efficient performance of plastic films in minimizing post-harvest deterioration and maintaining overall quality of cabbages stored under precise low-temperature conditions with remote monitoring and a control interface. Conclusions: Packaging with a modified plastic film and storage in a precisely controlled cooler with a remote monitoring and control interface could slow down the physiological factors that cause adverse quality changes and thereby increase the shelf life of Chinese cabbage.

Designing an expert system for library classification (문헌분류 전문가시스팀의 설계에 대한 연구)

  • 김정현
    • Journal of Korean Library and Information Science Society
    • /
    • v.21
    • /
    • pp.459-483
    • /
    • 1994
  • The purpose of the study is to design and implement a prototype expert system for library classification in the literature field of the DDC 20. The system was largely consisted of a knowledge base, an inference engine, a knowledge acquisition facility, an explanation facility and an user interface facility. The knowledge base was represented by inference rules and frames. The name file for authors and titles was designed separately. The forward chaining technique was chosen for the inference engine and the menu-driven dialog technique was also taken for the user interface. The conclusions of the study can be summarized as follows: 1) The difficulty of document classification work is due to the complex and stringent classification rules. Such problems can be considerably alleviated by using the present system. 2) Even the novice with a knowledge about the DDC 20 can easily access the system. And also librarian other than the professional classifier can easily be accustomed to the classification work. 3) The system can be used as an online classification scheme. 4) By adding any local language other than English or Hangeul on the menu screen, the language problem relating classification can be overcome. 5) The system can be employed as the intensification tool for the education of classification as well as library automation.

  • PDF

A Remote Monitoring and Control System for Waste Treatment Facility via Public Communication Network.

  • Jung, Jae-Hak;Choi, Jin-Yong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.124.2-124
    • /
    • 2001
  • The research for development of remote monitoring and control systems composed three stages of research categories. At the first stage, we decided the suitable instrumentation devices for interface between H/W systems and waste water treatment facility. And at the second stage, we developed the software package for remote monitoring and data transmission system including data receipt system via wired telephone line. At the final stage we developed local control system for auto-process control of waste water treatment facilities. For the first stage of research we developed the a drawing of design the instrumentation and selected optimal sensors or monitoring basic important data. After the first stage research we developed the software package with Graphic User Interface(GUI) ...

  • PDF

Aging Characteristics of Polymer Lighting Arrester by Multi-Stress Accelerated Aging Test (복합가속열화시험에 의한 폴리머 피뢰기의 경년특성)

  • Song, Hyun-Seok;Lee, Jae-Bong;Jang, Sang-Ok;Han, Yong-Huei;Oh, Jae-Hyoung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.86-89
    • /
    • 2004
  • Recently polymer arresters are being used widely but we don't have appropriate long term characteristics test methods. Therefore we need to develop special test facility to evaluate long term reliability of polymer arresters. It's polymeric housing can be degraded by environmental stress and the interface between housing and inner module can be affected by moisture absorption. This moisture absorption can cause leakage current and tracking in the interface. We developed multi stress accelerated ageing test facility to simulate field conditions including UV, temperature, humidity, voltage, salt fog and rain. In addition, we carried out field exposure test at the outdoor test yard and characteristics analysis of field operated specimens to evaluate accelerating factor of this accelerated aging test.

  • PDF

Development of a new test facility for the study of pressure transients in tunnel and micro-pressure waves radiated from the tunnel exit on the railroad (철도터널내 압력변동 및 터널 미기압파 저감 시험장치개발에 관한 연구)

  • Kim, Dong-Hyeon;Oh, Il-Geun
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.611-618
    • /
    • 2000
  • The test facility of the 1/60-scale models for the train-tunnel interactions was recently developed to investigate the effects of entry portal shapes, hood shapes and air-shafts for reducing the micro-pressure waves radiating to the surroundings of the tunnel exits by KRRI in Korea. The launching system of train model was chosen as air-gun type. In present test rig, after train model is launched, the blast wave by the driver did not enter to inside of the tunnel model. The train model is guided on the one-wire system from air-gun driver to the brake parts of test facility end. Some cases of the experiments were compared with numerical simulations to prove the test facility.

  • PDF

A Communication Method Between Distributed Control System and Function Test Facility Using TCP/IP and Shared Memory

  • Kim, Jung-Soo;Jung, Chul-Hwan;Kim, Jung-Taek;Lee, Dong-Young;Ham, Chang-Sik
    • Nuclear Engineering and Technology
    • /
    • v.30 no.4
    • /
    • pp.298-307
    • /
    • 1998
  • In order to design mutual communication between a distributed control system and a function test facility, we used the Inter-Process Communication(IPC) in two systems and Transmission Control Protocol/Internet Protocol(TCP/IP) protocol. The data from the function test facility are put in the shared memory using an IPC, which is then accessed by the distributed control system through an Application Program Interface(API). The server in the function test facility includes two processes(one for sending and one for receiving), which are generated by the fork function from the client signal. The client in the distributed control system includes two separate programs(one for receiving and one for sending).

  • PDF

3D Modeling and Simulation using Virtual Manipulator (가상 조작기를 이용한 3D 모델링 및 시뮬레이션)

  • Park, Hee-Seong;Kim, Ho-Dong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2011.04a
    • /
    • pp.547-550
    • /
    • 2011
  • The purpose of this paper is to verify and validate the maintenance tasks of the construction of a nuclear facility using a digital mock-up and simulation technology instead of a physical mock-up. Prior to the construction of a nuclear facility, a remote simulator that provides the opportunity to produce a complete digital mock-up of the PRIDE (Pyroprocess Integrated Inactive DEmonstration Facility) region and its remote handling equipment, including operations and maintenance procedures has been developed. In this paper, the system architecture and graphic user interface of a remote simulator that coincides with the extraordinary nature of a nuclear fuel cycle facility is introduced. In order to analyze the remote accessibility of a remote manipulator, virtual prototyping that was performed it by using haptic device of external input devices under a 3D full-scale digital mock-up is explained.

The development of fault monitoring system for lift type parking facility (승강기식 타워주차설비 고장 모니터링 시스템 개발)

  • Lee, W.T.;Cha, J.S.;Jeong, Y.K.;Kim, K.H.;Kim, B.U.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.739-741
    • /
    • 1999
  • This paper describes the fault monitoring system for lift type tower parking facilities. This system consists of tower parking facility control panel and monitoring computer, and offers real-time monitoring of parking status and fault detection, and status data acquisition of tower parking system using graphic user interface.

  • PDF

Implementation of HL7 Interface Engine for Medical Information Exchange (의료정보 공유를 위한 HL7 인터페이스 엔진 구현)

  • Hwang, Deuk-Young
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.8
    • /
    • pp.89-98
    • /
    • 2010
  • Recently supply of Internet is bringing a important change in medical environments. The hospitals which had a different system is required the system that can efficiently share and exchange medical information. In order to transmission medical information between systems, the Health Level Seven(HL7) interface engine development that can convert medical data to HL7 messages is necessary. The HL7 is a standard protocol for data exchange in healthcare environments. In this paper, I implemented HL7 interface engine for Alzheimer's disease in elderly care facility. The interface engine is composed of the client system and the server system. The client system inputs user's medical care data for the aged, and builds them into HL7 message stream. HL7 messages in the client system transmitted over TCP/IP protocol to the server system. The server system parses and validates this messages stream to the segments and fields and then transmits acknowledgement to the client system. I implemented it using the Java and JavaCC. The study of interface engine implementation can be used meaningfully in electronic health record, telemedicine system, and medical information sharing among various healthcare institutions.