SPACE STRUCTURE ANALYSIS OF COMPLEX CULTURE SHOPPING FACILITY.

  • Jae-Hong Hwang;Byung-ju Ank;Whoi-yul Kim;Jae-Joon Kim
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.1128-1133
    • /
    • 2009
  • Recently super complex culture shopping facility development seeks consumer' convenience present and are coming restaurant neighborhood, cinema, shopping, hotel etc, according to intensive plan. Such as complex culture shopping facility was developed to most subway station area center and have concept that is space for a main facilities or space for environment protection, citizens' a rest in city. Howeve,r space of recently domestic large size complex culture shopping facility that do not plan systematically was lacking and caused result that do not use efficiently space. Limited extent of research that define complex culture shopping equipment and analyze form of space and present space planning with analysis of research connected with complex usage development.

  • PDF

3D Modeling and Simulation using Virtual Manipulator (가상 조작기를 이용한 3D 모델링 및 시뮬레이션)

  • Park, Hee-Seong;Kim, Ho-Dong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2011.04a
    • /
    • pp.547-550
    • /
    • 2011
  • The purpose of this paper is to verify and validate the maintenance tasks of the construction of a nuclear facility using a digital mock-up and simulation technology instead of a physical mock-up. Prior to the construction of a nuclear facility, a remote simulator that provides the opportunity to produce a complete digital mock-up of the PRIDE (Pyroprocess Integrated Inactive DEmonstration Facility) region and its remote handling equipment, including operations and maintenance procedures has been developed. In this paper, the system architecture and graphic user interface of a remote simulator that coincides with the extraordinary nature of a nuclear fuel cycle facility is introduced. In order to analyze the remote accessibility of a remote manipulator, virtual prototyping that was performed it by using haptic device of external input devices under a 3D full-scale digital mock-up is explained.

On-Line Condition Monitoring of Electrical Equipment Using Temperature Sensor (온도센서를 이용한 전력설비의 온라인 상태 감시)

  • Choi, Yong-Sung;Kim, Sun- Jae;Kim, Yeong-Min;Song, Hwao-Kee;Lee, Kyung-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.202-208
    • /
    • 2008
  • Condition monitoring technologies allow achieving this goal by minimizing downtime through the integrated planning and scheduling of repairs indicated by condition monitoring techniques. Thermal runaways induced by conduction problems deteriorate insulating material and cause disruptive dielectric discharges resulting in arcing faults. Therefore, having the ability to directly measure the temperature of the contacts while in service will provide more information to determine the true condition of the equipment. It allows connective measures to be taken to prevent upcoming failure. Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on -line condition monitoring of energized equipment is applicable both as stand alone system and with an interface for power quality monitoring system. The paper presents the results of wireless temperature monitoring: of electrical equipment at a power plant.

An Establishment of Functional Test Facility for ICT-Convergence Equipment of Vessel : Focused on Maritime Digital Interfaces and Main Navigation Communication Systems (선박 ICT융합 장비 기능시험 시설 구축 연구 : 선박 디지털 인터페이스 및 주요 항해통신장비를 중심으로)

  • Hwang, Hun-Gyu;Kim, Bae-Sung;Woo, Snag-Min;Woo, Yun-Tae;Shin, Il-Sik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.5
    • /
    • pp.754-763
    • /
    • 2018
  • The maritime ICT-convergence equipment are essentially required to a type approval (TA) certification that needs environmental and functional tests, to install in vessel. The environmental test is to experiment the possession for required durabilities of the target device in maritime environment, and the functional test is to check the required functions of target equipment based on international standard. In Korea, the environmental testing facilities amount to 227 sites, but there is no functional testing facility. Because of this, we establish a function test facility for the maritime ICT-equipment. In this paper, we analyze and design the functional testing requirement and required interlocking simulators for digital interfaces and navigation communication equipment. We propose the 2-steps of functional testing procedures, which are single test and integration test, to improve the reliability of testing result. The single test is to examine own functions of the target device, and the integration test is to check harmonized operation with other navigation and communication devices.

A study on Surface Treatment of Dredged fill Ground (준설토의 표층처리에 관한 연구)

  • 정규향;이문수;이광찬;윤석군;오재화
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.569-574
    • /
    • 1999
  • In Soft ground of south-western coast of our country necessity of marine indutrial complex and container facility has been remarkable. Site construction for habor facility is one of the most urgent problems. Consolidation of dredged fill has become important task. In addition, volume change of dredged fill should be examined carefully. This study dealt with consolidation of dredged fill by PCDDF and in order to secure trafficability of heavy equipment for surface treatment should be studied.

  • PDF

A Study on a Neutralization Treatment Facility Design of an Acid Mine Drainage for Colliery (석탄광 산성항내배수의 중화 처리시설 설계에 관한 연구)

  • 이춘택
    • Journal of the Korean Professional Engineers Association
    • /
    • v.18 no.1
    • /
    • pp.1-17
    • /
    • 1985
  • This report is prepared to assist designers acid mine drainage treatment plants. Example of a treatment facility design is included, delineating general equipment specification and cost breakdowns. The purpose of this outline is to give the designer insight into tile evaluation of possible alternative and justification for choosing a certain method or process and also this report will allow designers to derive and estimated budget number for capital expenditures.

  • PDF

A Study of Efficient Floor Planning and Facility Improvement for Physical Therapy Room of Domestic Long-term Hospitals (국내 요양병원의 물리치료실의 효율적 평면계획 및 시설개선에 관한 연구)

  • Chung, Kwang-Ho
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.11 no.4
    • /
    • pp.5-11
    • /
    • 2011
  • The present study investigated the actual conditions of physical therapy rooms at long-term hospitals in Korea and conducted a comparative analysis to develop an efficient floor plan and facility improvement measures. 1. At hospitals surveyed, physical therapy services were used at a high frequency but they did not have enough space for rehab treatment and long paths of patient flow were found to make patient management inconvenient. Therefore, physical therapy units should be conveniently located both in terms of distance and direction so as to be accessible from patient rooms or wards. The space should be organized in a concentrated layout for efficiency of physical therapy, and floor planning for therapy units should ensure the best possible viewing angle to therapists. 2. With regard to the disease characteristics of patients, many physical therapy rooms were in difficult circumstances because of poor facilities, so they need to secure skilled personnel, supplement apparatuses and equipment and have rooms for functional recovery, hydrotherapy and operation treatment. In addition, each of the curtained or partitioned areas for treatment should be set up with consideration for the amount of space taken up by medical equipment. The area under each bed should be designed for patient convenience so that it can be used as storage space for patient's belongings and shoes. 3. Patients complained about the lack of physical therapy space, resting places or exercise areas and demanded the expansion of rehab programs and facilities. Physical therapy facilities need to be improved for patient privacy and effective natural ventilation. 4. At most of the long-term hospitals surveyed, physical therapy units were found to have small areas and treatment equipment and devices were insufficient compared to the number of patients. Therefore, it is required to secure more space (at least 138.24 sq. meters per 100 beds) and improve facilities for better physical therapy services.

A Study on the Priority of Drone Industry Infrastructure Investment (드론산업 인프라 투자 우선순위에 관한 연구)

  • Sim, Myung Sik;Lee, Sang-Joon;Song, Dong-Yeob
    • Smart Media Journal
    • /
    • v.9 no.3
    • /
    • pp.130-141
    • /
    • 2020
  • The drone market in Korea is growing with a focus on the use of prevention, defense, exploration and surveying, search and rescue, video shooting, and facility management. However, the foreign dependence on drone's core technologies and components is high. Drone-powered countries such as the US and China are expanding the weaponization of drones, which can intensify trade wars between countries, such as strengthening import and export regulations and monopoly. Therefore, Korea should put R & D and localization of core technology, parts, and accessories of next generation drone first. For this, policy research and investment in infrastructure, equipment, and research personnel should be preceded. This study studied the evaluation of investment priorities by infrastructure sector (facility equipment, utilization field, and demand manpower) to foster small drone companies through literature studies. To this end, we expanded and reclassified e isting research, developed investment prioritization indicators through expert group interviews and reviews, derived future uncertainties, and selected investment priorities by infrastructure sector using AHP techniques. Finally, it proposed an infrastructure construction strategy to foster small drone companies in terms of drone development support, utilization support.

A Study on the User Needs for Renovation of Race Track Type of Nursing Units in K University Hospital (K대학병원 병동부 이중복도형의 개선을 위한 사용자 요구 조사연구)

  • Kim, Youngaee;Yim, Ohyon;Kim, Jungshin;Yi, Jongse;Ahn, Uijong
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.19 no.3
    • /
    • pp.21-28
    • /
    • 2013
  • Purpose: General hospital in korea is getting large-scaled, specialized and upgraded. So, nursing unit of race track type has been advanced along with a spatial organization, building equipment and environmental approach. This study is to search the guidelines for renovation of nursing unit with race track type in the case of K university hospital in Daejeon. Methods: 9 cases of recently opened general hospital has been analyzed for spatial and environmental design solution. Questionnaires and interviews about user needs of nursing staff, patient and visitors, have been conducted for a nursing care system and facility of nursing units in K university hospital. Results: The user needs are represented as followings. Center core public zone in each floor plan and center core nursing station and supporting areas in nursing unit are good for an adjacency and separation of spatial organization. Toilet of group patient room is necessary to equip for easy, safe and infective aspects, and so toilet install will decrease the patient number and increase the nursing care service. Hall type of station front is good for visibility and observation. It is appropriate to renovate into south facing group patient room for privacy, enough space for nursing care facility and supporting area, enough width of door to move portable medical equipment, room for medical doctor and practical student, noise absorbing of day room. Implications: Upgrading the nursing care service and facility equipment is necessary to reflect the user needs and cooperate with hospital management.

A Study on the Facility and Equipment of Laboratory Medicine in General Hospital - Focused on less than three hundred bed hospitals (종합병원 진단검사의학과 검사실의 시설 현황 조사 - 300 병상 미만 병원을 중심으로)

  • Kim, Youngaee
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.3
    • /
    • pp.15-23
    • /
    • 2019
  • Purpose: As the medical laboratories in general hospitals have made an efforts on quality management and employee health, they recognized the need of design guideline for clinical laboratory. As laboratories are prohibited to patients, their environments are becoming more congested and deteriorated as time goes by. So, this study investigates the current status of facility and equipment of laboratory medicine focusing on less than three hundred patient bed hospitals, and searches the improving matters. Methods: Questionnaires to technologist captains and field surveys to medical laboratories in korean hospitals have been conducted for the data collection. 18 answers have been analysed statistically by MS Excel program. Results: The result of this study can be summarized into followings. Clinical laboratory functions are all hematology, clinical chemistry, immunology, transfusion and urine microscopy, and except for three including microbiology for infection and bio safety level. Average man power of lab are 12.3 man including lab director and captain. Patient bed number, space area and total specimen numbers are not correlated with each other, but specimen numbers and employee number are correlated with. Work space distances are usually good, but exit distances are not adequate for escape owing to obstacles. Specimen delivery system by courier, test method by automatic analyzer, access floor for exposed plumbing and electricities are more practical. Open lab layed out in the center and lab support layed peripheral in space diagram. Lab space configuration by SD method showed that lab support area and employee support area are dissatisfied. Implications: Specialized hospital and yearly total specimen numbers are related to the space area and organization for laboratory planning and design.