• Title/Summary/Keyword: Facility equipment

Search Result 810, Processing Time 0.028 seconds

Case Study of Design and Implementation for Hadoop-Based Integrated Facility Monitoring System (하둡 기반의 통합설비 모니터링시스템 설계 및 구현 사례 연구)

  • Kim, Sangrak;Jang, Gilsang;Cho, Chiwoon
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.40 no.1
    • /
    • pp.34-42
    • /
    • 2014
  • SCADA and DCS that have performed automatic control and monitoring activities increase the productivity of enterprise in industries. In such systems, although their performance had been improved, there are still many deficiencies in predictive maintenance which can foresee the risk of any kinds of accidents. Because the data acquisition systems of main facilities are being distributed throughout the whole plant and therefore, integration of data obtained from the systems is very difficult. Accordingly, techniques that acquire meaningful information from the gathered data through realtime analysis still need to be improved. This paper introduces a developed facility monitoring system which can predict equipment failure and diagnose facility status through big data analysis to improve equipment efficiency and prevent safety accidents.

The Relationship between scuba diving participant's selective attribute, emotional response, and empirical value

  • Lee, Yoo-Chan;Jung, Sang-Ok
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.13 no.3
    • /
    • pp.84-91
    • /
    • 2021
  • The purpose of this study is to investigate the structural relationship between resort selection attributes, emotional responses, and empirical values of scuba diving participants. The general population who enjoys scuba diving in Korea was selected as the population. Using the convenience sampling method, 553 of the 600 questionnaire samples were extracted as the final valid sample. For data processing, frequency analysis, exploratory factor analysis, and Cronbach's α test were performed using SPSS 23, and confirmatory factor analysis and structural equation model analysis were performed with AMOS 18. The results are as follows: First, among the sub-factors of selection attributes, equipment, facility environment, and diving point showed a positive effect on emotional response, but staff service did not have any significant effect. Second, the emotional response positively affected by the selection attribute showed a positive effect on all factors of service excellence, consumer utility, fun value, and aesthetic value of empirical value. Therefore, scuba diving resort managers must recognize the importance of equipment, facility environment, and diving point among these selection attributes of customers. And to satisfy the customer needs the resort must accurately identify the needs for diving equipment, facility environment and diving point. Various methods for this should be explored through the needs of the identified customers, and efforts should be made to provide safe equipment, comfortable facilities, and various diving points.

Performance Evaluation Method of Tunnel Scanner for Lining Crack Detection (터널 균열 검출에 활용되는 터널스캐너의 성능검증 방법론)

  • Bae, Sung-Jae;Jung, Wook;Chamrith, Sereivatana;Kim, Chan-Jin;Kim, Young-Min;Hong, Sung-Ho;Kim, Jung-Gon;Kim, Jung-Yeol
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.39-52
    • /
    • 2021
  • Purpose: Recently, due to increasing usage of high-tech equipment for facility inspection, the need of verifying high-tech equipment is being emphasized. Therefore, the purpose of this paper is to develop performance evaluation methodology of tunnel scanners that inspect tunnel facilities. Method: This paper describes literature reviews regarding the performance evaluation methodology of high-tech based equipment for facility inspection. Based on these investigations and expert advisory meetings, this paper suggests a performance evaluation methodology of tunnel scanner. Result: First evaluation indicator states minimum performance standards of tunnel scanners. Second evaluation indicator is related to tunnel scanner quality. Conclusion: The performance evaluation methodology can provide reliable equipment performance catalogues, helping users to make a proper selection of equipment. Also, developers of equipment can get authorized verification of performances, preventing poor maintenance of facilities.

Construction and Functional Tests of Fuel Assembly Mechanical Characterization Test Facility (핵연료집합체 기계적특성 시험시설 구축과 기능시험)

  • Lee, Kang-Hee;Kang, Heung-Seok;Yoon, Kyung-Ho;Yang, Jae-Ho
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.11-16
    • /
    • 2016
  • Fuel assembly's mechanical characterization test facility (FAMeCT) in KAERI was constructed with upgraded functional features such as increased loading capacity, underwater vibration testing and severe earthquake simulation for extended fuel design guideline. This facility is designed and developed to provide out-pile fuel data for accident analysis model and fuel licensing. Functional tests of FAMeCT were performed to confirm functionality, structural integrity, and validity of newly-built fuel assembly mechanical test facility. Test program includes signal check of data acquisition system, load delivering capacity using real-sized fuel assemblies and a standard loading cylindrical rigid specimen. Fuel assembly's lateral bending test was carried out up to 30 mm of pull-out displacement. Limit case axial compression loading test up to 33 kN was performed to check structural integrity of UCPS (Upper Core Plate Simulator) support frame. Test results show that all test equipment and measurement system have acceptable range of alignment, signal to noise ratio, load carrying capacity limit without loss of integrity. This paper introduces newly constructed fuel assembly's mechanical test facility and summarizes results of functional test for the mechanical test equipment and data acquisition system.

Automated Maintenance Unmanned Monitoring System Using Intelligent Power Control System (지능형 전원제어장치를 이용한 자동화 유지보수 무인감시시스템)

  • Cha, Min-Uk;Lee, Choong Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.237-239
    • /
    • 2021
  • Failure and malfunction of the unmanned surveillance facility cost can lead to delays occurring until the person in charge arrives at the unmanned surveillance facility, and theft, damage, and information leakage damage caused by intruders. In addition, due to equipment failure and malfunction, additional costs are incurred due to constant inspection by the manager. In this paper, in order to compensate for the malfunction of unmanned facility costs, we propose a system that diagnoses the monitoring facility in real time, displays the contents of the problem, automatically restores the facility power, and informs the person in charge of the situation by text message. The proposed system is a surveillance facility consisting of main facilities such as video equipment (CCTV), sound equipment, floodlights, etc. And SMS server that can send text messages in real time. Through experiments, the effectiveness of the proposed system was verified.

  • PDF

Development of Campus Facility Management System using GIS - Focused on Kyungpook National University - (GIS를 이용한 대학시설물 관리시스템 개발 - 경북대학교를 중심으로 -)

  • Lee, Seung-Yeob;Im, Yong-Ho;Choi, Hyun-Sang
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.1 no.1
    • /
    • pp.18-27
    • /
    • 1998
  • This paper, deals with the developmental result of university facility management system using GIS, is to explain the developmental process of this system and the merits and the faults of GIS facility management system. Facility management, as a discipline, is the practice of coordinating the people and the work of an organization into the physical workplace. According to rising costs for the facility management and effective management for the existing facility, the organization need to optimize the use of existing facilities and equipment to prevent unnecessary investments in facilities and equipment. The purpose of this study is to build GIS based university facility management system using GIS. Based on 1/5,000 from national geography institute and 1/600 map, we construct base map for study and, using genasys genius program, we made facility management system. This system includes geographic management, infrastructure management and building management, and, using each attribute information, it is possible to use not only for effective management for existing facilities but also available to future decision making.

HOT CELL RENOVATION IN THE SPENT FUEL CONDITIONING PROCESS FACILITY AT THE KOREA ATOMIC ENERGY RESEARCH INSTITUTE

  • YU, SEUNG NAM;LEE, JONG KWANG;PARK, BYUNG SUK;CHO, ILJE;KIM, KIHO
    • Nuclear Engineering and Technology
    • /
    • v.47 no.6
    • /
    • pp.776-790
    • /
    • 2015
  • Background: The advanced spent fuel conditioning process facility (ACPF) of the irradiated materials examination facility (IMEF) at the Korea Atomic Energy Research Institute (KAERI) has been renovated to implement a lab scale electrolytic reduction process for pyroprocessing. The interior and exterior structures of the ACPF hot cell have been modified under the current renovation project for the experimentation of the electrolytic reduction process using spent nuclear fuel. The most important aspect of this renovation was the installation of the argon compartment within the hot cell. Method: For the design and system implementation of the argon compartment system, a full-scale mock-up test and a three-dimensional (3D) simulation test were conducted in advance. The remodeling and repairing of the process cell (M8a), the maintenance cell (M8b), the isolation room, and their utilities were also planned through this simulation to accommodate the designed argon compartment system. Results and conclusion: Based on the considered refurbishment workflow, previous equipment in the M8 cell, including vessels and pipes, were removed and disposed of successfully after a zoning smear survey and decontamination, and new equipment with advanced functions and specifications were installed in the hot cell. Finally, the operating area and isolation room were also refurbished to meet the requirements of the improved hot cell facility.

Influence of D.I. Water Pressure and Purified $N_2$ Gas on the Inter Level Dielectric-Chemical Mechanical Polishing Process (탈이온수의 압력과 정제된 $N_2$ 가스가 ILD-CMP 공정에 미치는 영향)

  • Kim, Sang-Yong;Seo, Yong-Jin;Kim, Chang-Il;Chung, Hun-Sang;Lee, Woo-Sun;Chang, Eui-Goo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.04b
    • /
    • pp.31-34
    • /
    • 2000
  • It is very important to understand the correlation of between inter layer dielectric(ILD) CMP process and various facility factors supplied to equipment system. In this paper, the correlation between the various facility factors supplied to CMP equipment system and ILD CMP process were studied. To prevent the partial over-polishing(edge hot-spot) generated in the wafer edge area during polishing, we analyzed various facilities supplied at supply system. With facility shortage of D.I. water(DIW) pressure, we introduced an adding purified $N_2(PN_2)$ gas in polishing head cleaning station for increasing a cleaning effect. DIW pressure and PN2 gas factors were not related with removal rate, but edge hot-spot of patterned wafer had a serious relation. We estimated two factors (DIW pressure and PN2 gas) for the improvement of CMP process. Especially, we obtained a uniform planarity in patterned wafer and prohibited more than 90% wafer edge over-polishing. In this study, we acknowledged that facility factors supplied to equipment system played an important role in ILD-CMP process.

  • PDF

Factors related to willingness of choosing the same hospital (입원환자의 재선택 의향과 결정요인)

  • Seol, Dong-Won;Yu, Seung-Hum;Park, Eun-Cheol;Kim, Eun-Suak
    • Korea Journal of Hospital Management
    • /
    • v.2 no.1
    • /
    • pp.65-79
    • /
    • 1997
  • This study aims to measure in-patients' willingness to choose the same hospital, and to define the related factors. The willingness was measured by the fact whether in-patients would return to the same hospital for their future hospitalization and can be said as the essence of ascertaining patients' satisfaction. Data was collected from 236 patients hospitalized in two hospitals selected according to its superiority, one being superior in medical technique, the other being superior in facility and equipment. To enhance the comparability between the two hospitals, the department and the diagnosis were matched, and structured questionnaires were self-fill-up. The main findings are as follows. Hospitals were analyzed by their superiority : medical services, facility and equipment. In case of hospitals with superior medical services, the willingness was proportional to positive doctor-patient relationship, to satisfaction with the medical level, and to the acknowledgement of utility in cure. In case of hospitals with superior facility and equipment, the willingness was proportional to the satisfactory state of overall facility. Two types of hospitals were combined and analyzed. The willingness for choosing hospitals with superior medical services was stronger than that for choosing the other hospitals. The satisfaction with overall facility, satisfaction with medical level, acknowledgement of utility in cure, positive doctor-patient relationship, and better consultation produced higher willingness to choose the same hospital. The willingness for the option shows to what degree the hospital suffices patients' expectation. Patients' understanding views were obviously influential. The satisfaction level for medical aspect was more influential than the level for non-medical aspect.

  • PDF

Development of a Hospital Foodservice Facility Plan and Model based on General Sanitation Standards and RACCP Guidelines (병원급식에 일반위생관리기준과 HACCP 제도 적용을 위한 시설모델 개발)

  • 이정숙;곽동경;강영재
    • Korean journal of food and cookery science
    • /
    • v.19 no.4
    • /
    • pp.477-492
    • /
    • 2003
  • The purposes of the study were to establish HACCP-based standards and guidelines for conducting a plan review to build, or renovate, hospital food service establishments, and ensure the safety of foodservice and reduce the risk of food borne illness. The scope of the study included suggestion for the planning of hospital foodservice facilities: layout, design, equipment and modeling. The results of this study can be summarized as follows: 1) The development of a foodservice facility plan based on the results of a survey, literature reviews and the results of interviews with foodservice managers from 9 general hospitals. This was composed of operational policies in foodservices, layout characteristics, space allocation, selection, design, specification standards for equipment and the construction principles of foodservice facilities. 2) Two foodservice facility models were developed, one for general hospitals with 900 beds (2,000 patients and 2,500 employee meals per day) and the other for general hospitals with 300 beds (600 patients and 650 employees meals per day). 3) The suggested kitchen space requirements for the foodservice facility models were 341.2 ㎡ (W 17,100mm x L 23,700mm) and 998.8㎡ (W 35,600mm x L 32,800mm) for the 300 and 900 beds hospitals, respectively, with both designs being rectangular. The space requirements for the equipment, in relation to the total operational area, in terms of ratios were 1:3.5 and 1:3.8 for the 300 and 900 beds hospitals, respectively. The recommended space allowances per bed for the developed foodservice facility models were 1.15 ㎡ and 1.11 ㎡ for the 300 and 900 beds hospitals, respectively, which were increased by more than 30% compared to those suggested in the precedent study, and considered appropriate for the implementation of the HACCP system. 4) The hospital foodservice facilities plans and models were developed based on the general sanitation standards, guidelines and the HACCP system, and included foodservice facility layout, product flow, physical separation between contaminated and sanitary areas, foodservice facility specifications with a 1/300 scale for a 300 bed, and a 1/400 scale for a 900 beds blueprint. 5) The main features of the developed foodservice facility plans and models were; physical separation between contaminated and sanitary areas to prevent cross contamination, product flow in one direction from the arrival of the raw material to the finished product, and separation of different work areas and the process of receiving & preparation of products, refrigeration & storage, cooking, assembly, cleaning & disinfection, employee areas and janitorial facilities. The proposed models from this study were presented as examples for those wanting to build, or renovate, their facility for the production of foods.