• 제목/요약/키워드: Facility communication

검색결과 574건 처리시간 0.029초

대학 시설물 유지관리 서비스 사용자 요청 패턴 분석 (Patterns in User Requests for Facility Management Services in Higher Education Facilities)

  • 엄미영;이강
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.95-96
    • /
    • 2015
  • This paper aims to identify patterns in users' requests for facility management (FM) services in higher education facilities. We analyzed data collected from 309 service request forms, made available via a department office and an enterprise resource planning system, at a private university in Seoul between May 2009 and February 2015. We found that the number of user requests were the highest in September and October. Requests for electronic and communication (E/C) services outnumbered those for architectural services and mechanical and plumbing (M/P) services. Repair requests for doors and windows were the most common under architectural services; repairs for air-conditioners and radiators were the most commonly under M/P services; and installation of electrical outlets, telephone wires, and internet services were the most sought-after E/C services. Maintenance requests were received every three months, while repair requests were received every six or seven months.

  • PDF

UMTS 이동통신망의 액세스망 설계 문제의 해법에 관한 연구 (Heuristics for the Access Network Design Problem in UMTS Mobile Communication Networks)

  • 김후곤;정용주;백천현
    • 경영과학
    • /
    • 제27권3호
    • /
    • pp.1-14
    • /
    • 2010
  • In this paper we study the access network design problem in Universal Mobile Telecommunication Systems (UMTS) networks. Given the location of radio base stations (node-Bs), their traffic demands, and the candidate facility centers for locating radio network controllers (RNCs), the problem is to determine the configuration of access network, including the number and location of facility centers, the number of RNCs in each facility center, and the links between RNCs and node-Bs, with the objective being to design such a network at the minimum cost. We provide a mathematical formulation of the problem with constraints on RNC and node-B capacities, along with a lower bounding method. We develop a heuristic algorithm with two different initial solution methods designed to strengthen the solution quality. The computational efficacy of their procedures is then demonstrated on a number of test problems.

전국단위(全國單位) 교육행정정보체계(敎育行政情報體系) 구축사업(構築事業) 적용(適用)을 위한 실험적(實驗的) 교육시설현황관리(敎育施設現況管理)시스템 개발(開發)에 관한 연구(硏究) (A Study on the Development of the Experimental Educational Facility Management Information System based on the Nationwide Development Plan of the Educational Administration Information System)

  • 옥종호;안병환
    • 교육시설
    • /
    • 제9권2호
    • /
    • pp.5-13
    • /
    • 2002
  • The main objective of this research is to develop an experimental educational facility management information system that will be used for maintaining existing educational facilities in the elementary, junior high, and high schools. The development is based on the nationwide development plan of the education administration information system. The system developed is accomplished by use of Map-application Information System(MAPIS), an applied commercial software that combines Geographic Information System(GIS) with existing Information and Communication Technologies(ICT) such as Database system, Multimedia methodology, and Internet system. In order to figure out the features to be improved in the system developed, the research interviewed the educational facilities management in the Ministry of Education and P Local Education Authority. The authors suggest the functional improvement of the system based on the interview results.

발전소 관리실의 작업환경 소음에 관한 연구 (A Study on the Workplace Noise Environment of Office Areas in Power Plant)

  • 김병삼
    • 한국생산제조학회지
    • /
    • 제7권4호
    • /
    • pp.35-41
    • /
    • 1998
  • The workplace noise environment is composed of three basic elements : manufacturing (in a generic sense) facilities, office areas, and the community around the facility. Work must be done by all employees , and this involves communication within a variety of locations within the facility ; areas may be extremely noisy, moderately noisy, or quiet, such as an office. At the same time, the facility should not be annoying to the community. In this paper, the workplace environmental noise of office areas in power plant are studied. Turbine generator in power plant generates the noise of 90∼95 dB(A) in the frequency range of 1 kHz, which may cause occupational hearing loss. By abatement method which are made of isolation material and distance damping effect, about 29.5 dB(A) reduction has been obtained in office areas of the Power Plant . But, the workplace environmental noise of office areas in the power plant is not suited to office's purpose.

Web기반 조명시설 제어 관리 시스템의 개발 (Development of Web-based Light Facility Control Management System)

  • 장병건;전창대
    • 조명전기설비학회논문지
    • /
    • 제19권1호
    • /
    • pp.182-189
    • /
    • 2005
  • 본 논문은 조명시설을 효과적으로 제어 관리를 위하여 휴대용 개인 단말기를 통하여 On-Line으로 작업이 가능한 Web서버의 개발에 관하여 연구하였다. 현재 조명시설의 제어는 단순한 기능에 의존하고 있는 실정이다. 본 연구를 통하여 개발된 결과물을 통하여 대중화된 휴대용 개인 단말기를 이용하여 실시간으로 조명시설을 효율적으로 제어 및 관리함으로써 경제적, 인력적인 면에서 효과를 얻을 수 있을 것이다.

A Study on the Tapered Balun for the UWB UHF Coupler

  • Park, Jae-Gu;Yi, Sang-Hwa;Kim, Kwang-Hwa;Rhee, Young-Chul
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권6호
    • /
    • pp.236-240
    • /
    • 2003
  • The UWB UHF coupler for GIS PD detection requires a balun (balance to unbalance transformer) to show its inherent UWB characteristics. In order to reduce the size of the balun and to make it practical in the conventional GIS, a novel tapered coaxial balun with a dielectric was proposed for the UWB UHF coupler. The performance of the proposed balun was verified through a series of simulations, measurements and experiments. As a result, both the conventional balun and the proposed balun, which has a length equal to one third of that of the conventional balun, demonstrated good S11 characteristics, whereas the efficiency of the proposed balun increased as much as about 30% in comparison to the conventional one.

구내 정보통신설비를 위한 정책제안과 통합구축모델 설계 (The politic suggestion and the design of integrate-construction model for installation of the residential IT facility.)

  • 강영창;임상출;김선형
    • 한국정보통신학회논문지
    • /
    • 제13권5호
    • /
    • pp.845-853
    • /
    • 2009
  • 본 논문은 정부에서 추진중인 유비쿼터스도시의 성공적 건설을 위하여 공동주택에 설치되는 홈 네트워크설비를 포함한 전기통신설비 및 방송공동수신설비의 기술기준과 초고속 정보통신건물인증제도의 문제점을 알아보고 해결방안으로 주택법령의 주택성능 등급표시 제도보완과 유지관리를 제도화 하기위한 주택법계열의 전면적인 검토 보완 및 개정안을 제시하였다. 또한 기술기준만을 적용한 건축물과 초고속 정보통신건물 인증 2등급 이하 취득 건축물 그리고 상기 해결방안이 법제도화가 되었을 때의 건축물에 대한구내 정보통신선로 통합구축 모델을 각각 설계하여 제시하였다.

수질복원시설물 내 센서 네트워크 이기종간 인터페이스용 프로토콜에 관한 연구 (A Study for Protocol for Heterogeneous Interface in Sensor Networks within Water Restore Facilities)

  • 김찬;신재권;차재상
    • 한국인터넷방송통신학회논문지
    • /
    • 제12권5호
    • /
    • pp.255-260
    • /
    • 2012
  • 현재 운영되는 주요 하 폐수 처리시설 관리에 있어 환경 보호를 위한 엄격한 규제로 수질오염 측정 시스템에 관한 시스템이 부각되고 있다. 하지만 기존 하 폐수 처리 시스템은 하 폐수에 특화된 수질감시 기술이 미흡하며, 그중 센서와 네트워크를 통한 1:n 데이터 전송이 아닌 1:1을 지향하며, 이기종간 통신방식에 대한 호환성이 미비하다. 또한, 주로 수동방식의 검출방식을 준수하고 있다. 이에 본 논문에서는 수질복원시설물 내에 자동화된 센서 네트워크 통합 인터페이스를 위한 센서와 수질감지통합인터페이스간의 효율적인 데이터 전송에 관한 프로토콜 기술에 관해 연구하였다. 센서 네트워크 통합 인터페이스용 모니터링 구현을 통해 이기종간 통신방식으로 원활한 데이터 전송이 가능함을 입증하였다.

지하 매설물 원격 관리를 위한 2.4 GHz 대역의 인쇄형 야기 안테나 (A Printed Yagi Antenna Available at 2.4 GHz for Remote Management of Underground Facility)

  • 박동국;조익현;서홍은;윤나라;김진영
    • 한국전자파학회논문지
    • /
    • 제19권12호
    • /
    • pp.1360-1366
    • /
    • 2008
  • 본 논문에서 지하 매설물의 원격 관리에 적용이 가능한 2.45 GHz의 지표면 매입형 인쇄형 야기 안테나를 제안하였다. 안테나의 방수 및 견고성을 위해 백크라이트로 안테나를 감싸는 구조로 제작하였다. 제작된 안테나는 $2.15{\sim}2.52\;GHz$ 대역에서 이득 10 dBi로 동작하며, 시뮬레이션 결과와 유사한 결과를 나타내었다. 개발된 안테나는 지하 매설물 원격 관리를 위해 활용이 될 것으로 기대된다.

전국의 대피시설 실태조사를 통한 민방위 대피시설 표준 정립 모델 구축 연구 (A Study on Civil Defense Evacuation Facilities)

  • 박남희;여욱현;김태환
    • 한국재난정보학회 논문집
    • /
    • 제8권1호
    • /
    • pp.56-70
    • /
    • 2012
  • 현재 우리나라에 설치되어 있는 민방위 대피시설을 조사하여 그동안 시설 지정에 치우쳐왔던 민방위 대피시설 운영 실태를 파악할 필요가 있다. 본 연구의 목적은 현 민방위 대피시설에 대한 시설설비, 관리 등의 조사 및 문제점 분석을 통해 민방위대피시설의 실태를 분석하고 이를 바탕으로 민방위대피시설의 표준 정립모델을 구축하는 것이다. 본 연구의 결론은 다음과 같다. 첫째, 민방위 대피시설은 지역별로는 서울에 가장 많이 분포하고 있고, 시설별로는 아파트주차장의 빈도가 가장 높다. 둘째, 민방위 대피시설이 주기적으로 점검을 하고 있는 것으로 나타났으나 시설별 점검회수가 일정하지 않고 체계적인 점검이 이루어지고 있는 것으로 보기 어렵다. 셋째, 유선전화, CCTV, 이동통신설비, 방송설비 등 통신시설이 없는 대피시설이 많은 것으로 나타나 비상 상황시 외부와의 연락에 어려움이 예상된다. 넷째, 종합적으로 보면 현재 수도권 및 대도시 중심으로 2000년 이전에 건축되어 비교적 노후한 대피시설이 많은 것으로 보인다. 정립모델안은 위치, 규모, 수용인원, 인접시설과의 거리, 독립공간 유무, 개구부, 계단, 진입방식, 시설관리, 안내시설, 전기시설, 통신시설, 소방시설, 냉난방시설, 급배수시설, 위생시설 측면에서 필수 사항을 정리하였다.